Displaying all 4 publications

Abstract:
Sort:
  1. Asif S, Choon DS
    J Orthop Surg (Hong Kong), 2005 Dec;13(3):280-4.
    PMID: 16365492
    To evaluate the midterm results of 50 patients who underwent total knee replacement using Press Fit Condylar (PFC) Sigma system.
    Matched MeSH terms: Arthroplasty, Replacement, Knee/instrumentation*
  2. Nisar A, Choon DS, Varaprasad M, Abbas AA
    Med J Malaysia, 2006 Feb;61 Suppl A:100-2.
    PMID: 17042242
    A variety of reconstructive options exist for revision of both femoral and acetabular components in total hip replacement surgery. The use of impaction bone grafting with morsellised allograft has shown promising results in revision total hip arthroplasty. It works as a biologic reconstitution of bone stock defects and provides a solid construct with stable fixation. We present a case of bilateral revision total hip arthroplasty with poor bone stock where reconstructive surgery was done by using impaction bone grafting, mesh and C-stem implants.
    Matched MeSH terms: Arthroplasty, Replacement, Knee/instrumentation
  3. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Arthroplasty, Replacement, Knee/instrumentation*
  4. Fong TS, Kim SC, Kim JE, Lee ES, Kim TW, Lee YS
    J Arthroplasty, 2019 09;34(9):1929-1937.
    PMID: 31138501 DOI: 10.1016/j.arth.2019.04.061
    BACKGROUND: This study aimed at assessing the morphometry of resected femurs in Korean patients during total knee arthroplasty (TKA) and comparing these measurements with current Western-designed femoral component dimensions.

    METHODS: This single-blind, prospective, randomized, controlled trial involved intraoperative measurements for 271 femoral component implantations from 3 contemporary TKA systems, with 2 systems offering narrow sizing options. The difference between femoral component dimensions and the resected surface of distal femur was measured in millimeters at 5 distinct zones.

    RESULTS: Overhang of standard femoral component was common in the anterior-medial condyle and anterior-lateral condyle ranging from 50.8% to 99.0% and 21.5% to 88.0%, respectively. With narrow femoral components, the rate of overhang reduced to 21.5%-30.2% and 9.2%-32.1%. Conversely, underhang rates were higher over the anterior flange width, middle medial-lateral and posterior medial-lateral zones. Standard components displayed higher underhang rates at these zones compared to narrow components. The good fit rate for femoral component was low among the 3 systems ranging from 1.0% to 56.0%. System with narrow option sizing increases the underhang rates in males, while improving the component fit among females at similar zones with rate ranging from 5.2% to 52.9%.

    CONCLUSION: Currently available TKA implant designs may not provide a perfect match for the distal femoral shape of the Korean population. The availability of implants with standard and narrow options can substantially improve the optimal fitting of femoral components in the Korean population.

    Matched MeSH terms: Arthroplasty, Replacement, Knee/instrumentation