  1. Al-Hashedi AA, Taiyeb-Ali TB, Yunus N
    Aust Dent J, 2016 06;61(2):208-18.
    PMID: 25966305 DOI: 10.1111/adj.12337
    BACKGROUND: Short dental implants can be an alternative to bone augmentation procedures at sites of reduced alveolar bone. Most studies on short implants are retrospective or multicentre reports that lack controlled and consistent comparison between different systems. This study aimed to compare clinical and radiographic outcomes of short implants in two different systems in the posterior mandible.

    METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.

    RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.

    CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  2. Siar CH, Toh CG, Ali TB, Seiz D, Ong ST
    Clin Oral Implants Res, 2012 Apr;23(4):438-46.
    PMID: 21435011 DOI: 10.1111/j.1600-0501.2010.02145.x
    A stable oral mucosa is crucial for long-term survival and biofunctionality of implants. Most of this evidence is derived from clinical and animal studies based solely on implant-supported prosthesis. Much less is known about the dimensions and relationships of this soft tissue complex investing tooth-implant-supported bridgework (TISB). The aim here was to obtain experimental evidence on the dimensional characteristics of oral mucosa around TISB with two different abutment designs.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  3. Khalid T, Yunus N, Ibrahim N, Elkezza A, Masood M
    Clin Oral Implants Res, 2017 May;28(5):535-542.
    PMID: 26989853 DOI: 10.1111/clr.12831
    OBJECTIVE: To determine oral health-related quality of life (OHRQoL) and denture satisfaction (DS) in patients provided with mandibular implant-supported overdentures (ISOD) retained by two different attachment types, and the association of mandibular bone volume with the change in patient-reported outcome, before and after implant treatment.

    MATERIAL AND METHODS: Thirty-four patients (mean age 60.70  ±  8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis.

    RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001).

    CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  4. Yunus N, Masood M, Saub R, Al-Hashedi AA, Taiyeb Ali TB, Thomason JM
    Clin Oral Implants Res, 2016 Jul;27(7):904-9.
    PMID: 26173463 DOI: 10.1111/clr.12657
    OBJECTIVE: To assess the oral health-related quality of life (OHRQoL) of patients provided with mandibular implant fixed partial prostheses (IFPP) for rehabilitation of two adjacent missing posterior teeth and complete denture patients provided with mandibular implant-supported overdenture (ISOD). The response to change in OHRQoL with implant prostheses was additionally compared.

    MATERIAL AND METHODS: In this prospective study, 20 IFPP (mean age 47.0; SD 12.9 years) and 28 ISOD (mean age 61.5; SD 9.1 years) patients received 2 mandibular implants. Metal ceramic nonsplinted fixed prostheses were provided in IFPP group, while in ISOD group, the mandibular overdentures were retained by nonsplinted attachments. Patients rated their oral health-related quality of life using OHIP-14 Malaysian version at baseline (T0), 2-3 months (T1) and 1 year (T2) postimplant treatment. Mean OHIP-14 for total and domain scores between groups and intervals was analysed using repeated-measures ANOVA and t-test. Mann-Whitney and Wilcoxon signed-rank tests were used for the comparison of mean score change and effect size, while the association between pre- and post-treatment scores was determined using multivariate linear regression modelling.

    RESULTS: The total OHIP and domain scores before implant treatment were significantly higher (lower OHRQoL) in IFPP than in ISOD groups, except for physical pain where this domain showed similar impact in both groups. Postimplant scores between groups at T1 and T2 showed no significant difference. The mean score changes at T0-T1 and T0-T2 for total OHIP-14 and domains were significantly greater in IFPP except in the domains of physical pain and disability which showed no difference. Large effect size (ES) was observed for total OHIP-14 in IFPP while moderate in ISOD. Improved OHRQoL was dependent on the treatment group and pretreatment score.

    CONCLUSION: Improvement in OHRQoL occurred following both mandibular implant-supported overdentures and implant fixed partial prostheses.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  5. Patil PG, Nimbalkar-Patil S
    Contemp Clin Dent, 2015 Jul-Sep;6(3):318-20.
    PMID: 26321828 DOI: 10.4103/0976-237X.161869
    Recording of the maxillomandibular relationship (MMR) in implant complete arch restorations usually necessitates removal of the healing abutments to attach the record bases, which makes the procedures tedious and time-consuming.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  6. Mahat NS, Shetty NY, Kohli S, Jamayet NB, Patil P
    Evid Based Dent, 2023 Sep;24(3):142.
    PMID: 37369705 DOI: 10.1038/s41432-023-00904-5
    OBJECTIVE: To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.

    MATERIALS AND METHODS: The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.

    RESULTS: A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).

    CONCLUSION: Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  7. Baig MR, Rajan G, Yunus N
    Gerodontology, 2012 Jun;29(2):e1140-5.
    PMID: 21615782 DOI: 10.1111/j.1741-2358.2010.00433.x
    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  8. Taiyeb-Ali TB, Toh CG, Siar CH, Seiz D, Ong ST
    Implant Dent, 2009 Oct;18(5):438-46.
    PMID: 22129962 DOI: 10.1097/ID.0b013e3181ad8e7a
    To compare the clinical soft tissue responses around implant tooth-supported 3-unit bridges using tapered abutments with those using butt-joint abutments.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  9. Baig MR, Rajan G
    Indian J Dent Res, 2010 Apr-Jun;21(2):311-3.
    PMID: 20657109 DOI: 10.4103/0970-9290.66635
    This article describes the immediate placement and loading of implants in the aesthetic zone using an implant-retained, fixed prosthesis with a modified design. One section of the implant prosthesis has cemented crowns and the other section is the conventional screw-retained. This combined approach significantly offsets the unsuitable implant position, alignment or angulation, while ensuring the easy retrievability, repair and maintenance of the prosthesis at the same time.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  10. Rajan G, Baig MR, Nesan J, Subramanian J
    Indian J Dent Res, 2010 Jan-Mar;21(1):125-8.
    PMID: 20427922 DOI: 10.4103/0970-9290.62801
    Treatment of patients with aggressive periodontitis has always been a challenge to the clinician. Both young and old are known to be affected by this progressive destructive condition of the supporting dental structures. Although dental implants have been offered as a viable treatment alternative for such patients, additional procedures (like bone grafting) and delayed protocols have limited their usage. This case report describes the treatment of a young patient with aggressive periodontitis using a graftless implant solution. Zygoma implants in conjunction with conventional implants were used with immediate loading.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  11. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  12. Chen J, Ahmad R, Suenaga H, Li W, Swain M, Li Q
    J Biomech, 2015 Feb 5;48(3):512-9.
    PMID: 25560272 DOI: 10.1016/j.jbiomech.2014.11.043
    Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an in-silico approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6kPa and 39.9kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4kPa). Hydrostatic pressure in the mucosa signifies a critical indicator and can be correlated with clinically measured bone resorption, pointing to severer mandibular ridge resorption posteriorly with implant-retained overdentures. This study provides a biomechanical basis for denture treatment planning to improve long-term outcomes with minimal residual ridge resorption.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/instrumentation*
  13. Khuder T, Yunus N, Sulaiman E, Ibrahim N, Khalid T, Masood M
    J Oral Rehabil, 2017 May;44(5):398-404.
    PMID: 28295492 DOI: 10.1111/joor.12504
    This study aimed to investigate residual ridge resorption (RRR) of anterior and posterior maxillary and mandibular edentulous ridges, in patients treated with mandibular implant overdentures (IOD) and compare with conventional complete denture (CD) wearers, and to determine at each location, the association of RRR with the occlusal forces distribution and other patients' variables. The anterior and posterior RRR of IOD (six males, 17 females) and CD (12 males, 11 females) groups were determined using baseline and follow-up dental panaromic radiographs (DPT) (mean intervals 4 ± 1·8 years). The bone ratios were calculated using proportional area: anatomic to fixed reference areas and mean difference of ratios between the intervals determined RRR. The ridge locations included anterior and posterior maxillary and posterior mandibular arches. The T-Scan III digital occlusal system was used to record anterior and posterior percentage occlusal force (%OF) distributions. There were significant differences in anterior and posterior %OF between treatment groups. Two-way anova showed RRR was significant for arch locations (P = 0·005), treatment group (IOD versus CD) (P = 0·001), however, no significant interaction (P = 0·799). Multivariate regression analyses showed significant association between RRR and %OF at anterior maxilla (P = 0·000) and posterior mandible (P = 0·023) and for treatment groups at posterior maxilla (P = 0·033) and mandibular areas (P = 0·021). Resorption was observed in IOD compared to CD groups, with 8·5% chance of less resorption in former and 7·8% in the latter location. Depending on arch location, ridge resorption at various locations was associated with occlusal force distribution and/or treatment groups (implant prostheses or conventional complete dentures).
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/instrumentation*
  14. Siar CH, Toh CG, Romanos G, Swaminathan D, Ong AH, Yaacob H, et al.
    J. Periodontol., 2003 May;74(5):571-8.
    PMID: 12816287
    Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  15. Shankargouda SB, Sidhu P, Kardalkar S, Desai PM
    J Prosthodont, 2017 Feb;26(2):168-171.
    PMID: 26479878 DOI: 10.1111/jopr.12385
    Residual ridge resorption is a rapid, progressive, irreversible, and inevitable process of bone resorption. Long-standing teeth and implants have been shown to have maintained the bone around them without resorption. Thus, overdenture therapy has been proven to be beneficial in situations where few remaining teeth are present. In addition to the various advantages seen with tooth-supported telescopic overdentures, a few shortcomings can also be expected, including unseating of the overdenture, increased bulk of the prosthesis, secondary caries, etc. The precise transfer of the secondary telescopic copings to maintain the spatial relationship, without any micromovement, remains the most critical step in ensuring the success of the tooth-supported telescopic prosthesis. Thus, a simple and innovative technique of splinting the secondary copings was devised to prevent distortion and micromovement and maintain its spatial relationship.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/methods*
  16. Alsrouji MS, Ahmad R, Abdul Razak NH, Shuib S, Kuntjoro W, Baba NZ
    J Prosthodont, 2019 Feb;28(2):e764-e770.
    PMID: 30044033 DOI: 10.1111/jopr.12954
    PURPOSE: To relate the principal stress, strain, and total deformation in the premaxilla region beneath a complete denture to the pattern of premaxilla bone resorption when opposed by a conventional complete denture (CD) or by a two-implant-retained overdenture (IOD) using finite element analysis (FEA).

    MATERIALS AND METHODS: Three-dimensional solid models of the maxilla, mucosa, and denture of a selected edentulous patient were created using Mimics and CATIA software. The FEA model was created and duplicated in ANSYS 16.0 to perform two simulations for the IOD and the CD models. The values of maximum stress and strain and total deformation were obtained and compared to the outcomes of premaxilla resorption from a parallel clinical study.

    RESULTS: The maximum principal stress in the premaxilla in the IOD model ranged from 0.019 to 0.336 MPa, while it ranged from 0.011 to 0.193 MPa in the CD model. The maximum principal strain in the IOD model was 1.75 times greater than that in the CD model. Total deformation was 1.8 times higher in the IOD model. Greater bone resorption was observed in regions of higher stress, which were on the occlusal and buccal sides of the premaxilla residual ridge.

    CONCLUSION: Stress, strain, and total deformation values present in the premaxilla area beneath a CD were approximately two times greater in a comparison between an opposing mandibular two-IOD and an opposing mandibular CD. The results were consistent with a parallel clinical study in which the rate of premaxilla bone resorption was almost three times greater in the IOD group.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported/adverse effects*
  17. Alsrouji MS, Ahmad R, Rajali A, Mustafa NWNA, Ibrahim N, Baba NZ
    J Prosthodont, 2019 Feb;28(2):131-137.
    PMID: 30427557 DOI: 10.1111/jopr.12999
    PURPOSE: To compare the residual ridge resorption (RRR) of the anterior maxillary bone beneath complete dentures when opposed by mandibular complete dentures (CD) and implant-retained overdentures (IRO).

    MATERIALS AND METHODS: 18 patients were rehabilitated with maxillary CD opposing mandibular IRO, and 4 patients were prescribed with conventional CD. Cone beam computed tomography (CBCT) scans of the maxilla were acquired before and 1 year post-treatment and converted into 3D models using Mimics research software. RRR was quantified by measuring the changes in bone volume following superimpositioning and sectioning of these models at the anterior maxillary region. Subsequently, the sectioned 3D models of the anterior maxilla were exported to 3-Matic software to reveal the predominant region and depth of RRR.

    RESULTS: The mean reduction in bone volume of the anterior maxilla in the CD group was 2.60% (SD = 1.71%, range = -4.89 % to -0.92%, median = -2.30%), while the mean reduction in the IRO group was almost three times higher at 7.25% (SD = 3.16%, range = -13.25 to -1.50, median = -7.15%). The predominant areas of RRR were on the buccal and occlusal ridge of the anterior maxilla.

    CONCLUSION: Within the limits of this study, it may be concluded that an IRO caused significantly higher RRR of the anterior maxilla than a CD.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported/adverse effects*
  18. Alsrouji MS, Ahmad R, Ibrahim N, Kuntjoro W, Al-Harbi FA, Baba NZ
    J Prosthodont, 2019 Apr;28(4):373-378.
    PMID: 30875139 DOI: 10.1111/jopr.13047
    PURPOSE: Blood flow disturbance from functional pressure may lead to ischemia and accumulation of metabolites leading to residual ridge resorption (RRR) underneath complete dentures. The purposes of this study were to determine the effect of mandibular complete denture (CD) and implant-retained overdenture (IRO) on blood flow disturbance in the opposing denture bearing-mucosa of maxillary CD and to compare the blood flow disturbance to RRR of the anterior maxilla.

    MATERIALS AND METHODS: The test group included 9 participants rehabilitated by maxillary CD opposing mandibular IRO, while the control group consisted of 4 participants with CDs. Blood flow was measured by laser Doppler flowmetry (LDF) after denture removal for 0, 30, 60, and 90 minutes. RRR was quantified as reduction in bone volume a year post-treatment. The measurement of blood flow was then compared to the quantification of RRR.

    RESULTS: The mean blood flow measure for the IRO group was significantly lower than CD after immediate denture removal and 30 minutes later. After 60 minutes, the mean difference was not significant between groups, and at 90 minutes, the mean blood flow of both groups equalized to reach a steady state of 377 BPU. The mandibular IRO had reduced the initial blood flow measure in the opposing anterior maxilla mucosa to almost a quarter (103 BPU) of the steady state value (377 BPU) compared to the CD, which reduced it to only about one half (183 BPU), suggesting greater blood flow disturbance in the IRO group. This result is in tandem with the greater reduction of bone volume observed in the IRO group, which was 7.3 ± 1.3% after a year, almost three times higher than CD group at 2.6 ± 1.7%.

    CONCLUSION: IRO may cause significantly higher blood flow disturbance than CD and may have contributed to greater RRR in the anterior maxilla.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  19. Zhong J, Guazzato M, Chen J, Zhang Z, Sun G, Huo X, et al.
    J Mech Behav Biomed Mater, 2020 02;102:103490.
    PMID: 31877512 DOI: 10.1016/j.jmbbm.2019.103490
    Mechanical failure of zirconia-based full-arch implant-supported fixed dental prostheses (FAFDPs) remains a critical issue in prosthetic dentistry. The option of full-arch implant treatment and the biomechanical behaviour within a sophisticated screw-retained prosthetic structure have stimulated considerable interest in fundamental and clinical research. This study aimed to analyse the biomechanical responses of zirconia-based FAFDPs with different implant configurations (numbers and distributions), thereby predicting the possible failure sites and the optimum configuration from biomechanical aspect by using finite element method (FEM). Five 3D finite element (FE) models were constructed with patient-specific heterogeneous material properties of mandibular bone. The results were reported using volume-averaged von-Mises stresses (σVMVA) to eliminate numerical singularities. It was found that wider placement of multi-unit copings was preferred as it reduces the cantilever effect on denture. Within the limited areas of implant insertion, the adoption of angled multi-unit abutments allowed the insertion of oblique implants in the bone and wider distribution of the multi-unit copings in the prosthesis, leading to lower stress concentration on both mandibular bone and prosthetic components. Increasing the number of supporting implants in a FAFDPs reduced loading on each implant, although it may not necessarily reduce the stress concentration in the most posterior locations significantly. Overall, the 6-implant configuration was a preferable configuration as it provided the most balanced mechanical performance in this patient-specific case.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  20. Khuder T, Yunus N, Sulaiman E, Dabbagh A
    J Mech Behav Biomed Mater, 2017 11;75:97-104.
    PMID: 28709037 DOI: 10.1016/j.jmbbm.2017.06.039
    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*