Displaying all 14 publications

Abstract:
Sort:
  1. Sharifah NA, Hayati AR, Meah F, al-Rashid Z
    Malays J Pathol, 1993 Jun;15(1):53-8.
    PMID: 8277791
    Our experience with 1,094 consecutive fine needle aspirations (FNAs) of the breast in 918 cases is presented. Correlation between the FNA cytology and subsequent histology of the lesions was available in 211 cases. FNA had a sensitivity rate of 87.3%, a specificity rate of 99.3% and a positive predictive value of 98.2%. A false negative diagnosis rate of 5.1% occurred. The overall diagnostic accuracy rate was 95.7%.
    Matched MeSH terms: False Negative Reactions
  2. Ng CH, Pathy NB, Taib NA, Mun KS, Rhodes A, Yip CH
    Asian Pac J Cancer Prev, 2012;13(4):1111-3.
    PMID: 22799290
    The ER-/PR+ breast tumor may be the result of a false ER negative result. The aim of this study was to investigate whether there is a difference in patient and tumor characteristics of the ER-/PR+ phenotype in an Asian setting. A total of 2629 breast cancer patients were categorized on the basis of their age, ethnicity, tumor hormonal receptor phenotype, grade and histological type. There were 1230 (46.8%) ER+/PR+, 306 (11.6%) ER+/PR-, 122 (4.6%) ER-/PR+ and 972 (37%) ER-/PR-. ER-/PR+ tumors were 2.5 times more likely to be younger than 50 years at diagnosis (OR: 2.52; 95% CI: 1.72-3.67). Compared to ER+/PR+ tumors, the ER-/ PR+ phenotype was twice more likely to be associated with grade 3 tumors (OR:2.02; 95%CI: 1.00-4.10). In contrast, compared to ER-/PR- tumors, the ER-/PR+ phenotype was 90% less likely to be associated with a grade 3 tumor (OR: 0.12; 95%CI:0.05-0.26), and more likely to have invasive lobular than invasive ductal histology (OR: 3.66; 95%CI: 1.47-9.11). These results show that the ER-/PR+ phenotype occurs in a younger age group and is associated with intermediate histopathological characteristics compared to ER+/PR+ and ER-/PR- tumors. This may imply that it is a distinct entity and not a technical artifact.
    Matched MeSH terms: False Negative Reactions
  3. Jayaram G, Swain M, Chew MT, Yip CH
    Acta Cytol., 2000 Mar-Apr;44(2):169-74.
    PMID: 10740602
    OBJECTIVE: To examine the fine needle aspiration cytologic features of invasive lobular carcinoma of breast and to discuss problems that may occur in cytodiagnosis.

    STUDY DESIGN: Fine needle aspiration cytologic smears from 21 cases of invasive lobular carcinoma (ILC) of breast were subjected to detailed cytomorphologic analysis. Features studied included pattern of cells, size of cells, nuclear placement, pleomorphism, presence of intracytoplasmic lumina (ICL) and signet ring cells.

    RESULTS: Cellularity was generally moderate or high, and the pattern was predominantly or partly dissociated in 86% of cases. Rosettelike pattern was discerned in alveolar-type ILC. Cell size was usually small or intermediate, with nuclei placed eccentrically in most cases. ICLs with or without signet ring cells were present in 12 cases (57%).

    CONCLUSION: A cytologic picture consisting of predominantly dissociated small or intermediate-sized tumor cells with eccentric nuclei, with some of the cells showing ICLs, is highly suggestive of ILC. Indian file pattern, another characteristic feature of ILC, is, however, focal and inconsistent. Variant patterns of ILC may show other cytologic features, such as rosettelike pattern (alveolar variant of ILC) or large cell pattern (pleomorphic variant of ILC) and may consequently be difficult to categorize on cytologic smears.
    Matched MeSH terms: False Negative Reactions
  4. Yeang HY
    Ann. Allergy Asthma Immunol., 2000 Jun;84(6):628-32.
    PMID: 10875493 DOI: 10.1016/S1081-1206(10)62415-5
    BACKGROUND:
    The prevalence of latex-specific IgE computed from the results of serologic assays is commonly thought to reflect, to a greater or lesser extent, the prevalence of latex allergy and its implied risk.

    OBJECTIVE:
    The study examines how imperfect test specificity of in vitro assays influences the precision of latex allergy prevalence that it estimates.

    METHODS:
    Various models encompassing a range of hypothetical test sensitivity and specificity values are investigated to gauge their influence on the estimate of latex allergy prevalence. The models examine these interactions in situations of high or low allergy prevalence.

    RESULTS:
    Serologic latex diagnostic assays with test specificity within the range of those of commercially available assays can greatly overestimate prevalence where the true prevalence is low (eg, of the order of one in 100 or one in 1,000). A formula to correct for errors in prevalence estimates arising from imperfect test sensitivity and specificity of an in vitro assay is presented.

    CONCLUSION:
    While serologic assays for latex IgE pose few hazards to the patient and are useful for confirming the diagnosis of latex allergy, the test results may vastly overestimate the true prevalence of latex allergy and its associated risks in situations where latex allergy is actually rare.
    Matched MeSH terms: False Negative Reactions
  5. Cox-Singh J, Pomrehn AS, Rahman HA, Zakaria R, Miller AO, Singh B
    Int J Parasitol, 1999 May;29(5):717-21.
    PMID: 10404266
    In the absence of a suitable Brugia malayi antigen detection assay, PCR remains one of the more sensitive alternatives to Giemsa-stained thick blood films for B. malayi detection. The need for refrigerated storage and transportation of blood has limited the use of PCR for large-scale epidemiology studies in remote endemic areas. Here we report simple finger-prick blood-spot collection, a one-tube DNA template extraction method and the development of a B. malayi-specific nested PCR assay. The assay was tested on 145 field samples and was positive for all 30 microscopy-positive samples and for an additional 13 samples which were microscopy-negative.
    Matched MeSH terms: False Negative Reactions
  6. Noraini AR, Gay E, Ferrara C, Ravelli E, Mancini V, Morra E, et al.
    Singapore Med J, 2009 Dec;50(12):1189-95.
    PMID: 20087557
    To establish the role of positron-emission tomography (PET)-computed tomography (CT) in post-transplant lymphoproliferative disorder (PTLD) patients, compared to conventional imaging (ultrasonography/CT/magnetic resonance imaging) in relation to its accuracy, sensitivity and specificity.
    Matched MeSH terms: False Negative Reactions
  7. Haslina MN, Khairiah Y, Zainy DZ, Shafini MY, Rosnah B, Marini R
    PMID: 23077846
    The aim of this study was to determine the prevalence of HCV infection and the signal/cutoff (S/CO) value for false reactive, false positive, indeterminate and true positive HCV infection among apparently healthy blood donors in our area. This retrospective study was conducted at the Transfusion Medicine Unit, Hospital Universiti Sains Malaysia from June 2008 to June 2009. Blood samples were screened for anti-HCV using enzyme immunoassay (EIA). Reactive cases were confirmed by recombinant immunoblot assay (RIBA). Sixty-one blood donors were found to be reactive after the first screening test. Twenty-nine blood donors had reactive repeat screening, with only 9 samples being true positives. The S/ CO for false reactive, false positive, indeterminate and true positive anti-HCV samples were 1.02 to 1.45, 1.01 to 2.09, 1.07 to 2.43 and 35.95 to 119.89, respectively. The analysis showed the low incidence of HCV infections among blood donors in our area, however, thorough donor screening and stringent selection criteria are still recommended to eliminate high risk donors to improve our blood transfusion service.
    Matched MeSH terms: False Negative Reactions
  8. Jamaludin S, Mustaffa N, Che Hamzah NA, Syed Abdul Aziz SH, Lee YY
    BMC Gastroenterol, 2015;15:101.
    PMID: 26264957 DOI: 10.1186/s12876-015-0332-0
    Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest kits, comparing this to the use of new Pronto Dry test kits and histopathological evaluation of gastric mucosal biopsies.
    Matched MeSH terms: False Negative Reactions
  9. Khoo JJ
    Med J Malaysia, 2004 Mar;59(1):50-5.
    PMID: 15535336 MyJurnal
    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.
    Matched MeSH terms: False Negative Reactions
  10. Radhiana H, Azian AA, Mubarak MY, Saat A, Mohd Amran AR, Jamalludin AR
    Med J Malaysia, 2012 Jun;67(3):316-22.
    PMID: 23082425 MyJurnal
    Multislice computed tomography (MSCT) is the imaging modality of choice in assessing clinically stable patients with blunt abdominal trauma. This study assessed the role of MSCT in the detection of intra abdominal injury caused by blunt trauma in our centre within a two-year-period (2008-2009). A total of 151 patients had MSCT abdomen for blunt abdominal trauma within this study period. Positive scan were seen in 126 patients (83.4%). Out of these positive scans, liver, spleen and renal injuries were seen in 42.1% (n = 53), 34.9% (n = 44) and 30.0% (n = 34) of cases respectively. Laparotomies were performed in 45 patients. Out of these 45 laparotomies, 10 patients had surgically significant injuries that were missed on CT scan findings. The injuries were bowel perforation (n = 4), serosal tear of bowel (n = 1), mesenteric injuries with active haemorrhage (n=3), spleen injury (n = 1) and liver injury (n = 1).
    Matched MeSH terms: False Negative Reactions
  11. Jayaram G, Dashini M
    Malays J Pathol, 2001 Dec;23(2):93-100.
    PMID: 12166598
    141 salivary gland lesions that were subjected to fine needle aspiration (FNA) cytology at the University Hospital, Kuala Lumpur, from January 1993 to October 2000 were reviewed with a view to assess the sensitivity and utility of cytological diagnosis in diseases of salivary glands. The highest number of cases was seen in the sixth decade of life. There was no gender preponderance in salivary gland neoplasms except in Warthin's tumours that occurred predominantly in males. The parotid gland was the most frequent salivary gland needled. Seven cases (5%) presented with bilateral salivary gland enlargement. Cytological study yielded a neoplastic diagnosis in 74.5% cases. Of the neoplastic lesions, 71.4% could be definitely designated as benign and 25.7% as clearly malignant. Pleomorphic adenoma and acinic cell carcinoma were the most common benign and malignant neoplasms diagnosed respectively. 53 cases had histological correlation; of these, 49 (92.5%) were neoplastic. The overall diagnostic accuracy of FNA cytological diagnosis in salivary gland lesions was found to be 73.6%.
    Matched MeSH terms: False Negative Reactions
  12. Ooi BG, Sinniah M, Ismail S, Baharuddin R
    Malays J Pathol, 1996 Dec;18(2):89-93.
    PMID: 10879228
    The Serodia-HCV Particle Agglutination (HCV-PA) for the detection of HCV antibodies was compared with the Enzyme Immunoassay Test (UBI HCV EIA) for possible in-house use. A total of 150 specimens were analysed using UBI HCV EIA and Serodia-HCV PA. Of these, 80 (53.3%) were both PA and EIA positive and 59 (39.3%) were negative by both techniques. Eleven sera (7.4%) were found to be EIA-positive but PA-negative. These 11 discordant sera were further tested by the LiaTek-HCV III Immunoassay (Organon Teknika). Ten were found to be line immunoassay negative and one was line immunoassay positive. Failure of the PA to detect the HCV positive serum meant that a small proportion of HCV antibody positives may be missed by the PA test. We conclude that (i) EIA should continue to be the first line screening test in our laboratory, (ii) PA with its 100% specificity could be a useful supplementary screen for all EIA-positive sera and finally (iii) line immunoassay could be used on sera to resolve discordant results in the EIA and PA assays.
    Matched MeSH terms: False Negative Reactions
  13. Yaacob I, Ahmad Z
    Med J Malaysia, 1990 Sep;45(3):231-4.
    PMID: 2152084
    The value of tuberculin skin testing in the diagnosis of active tuberculosis remains uncertain. Interpretation of tuberculin tests would be easier if the tuberculin test profiles in different communities were accurately known. We reviewed 468 Mantoux test reactions in patients coming to Hospital Universiti Sains Malaysia with suspected tuberculosis. Eighty six percent of patients with active tuberculosis had a positive Mantoux test. Forty two percent of the cases of positive Mantoux test did not have evidence of active tuberculosis. Most of these cases had evidence of past infection with tuberculosis. We conclude that Mantoux test is a sensitive but a non-specific test in the diagnosis of active tuberculosis.
    Study site: outpatients, inpatients; Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia
    Matched MeSH terms: False Negative Reactions
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links