Abstract:
Sort:
  1. Jamail M, Andrew K, Junaidi D, Krishnan AK, Faizal M, Rahmah N
    Trop Med Int Health, 2005 Jan;10(1):99-104.
    PMID: 15655019
    We conducted a field study of a rapid test (Brugia Rapid) for detection of Brugia malayi infection to validate its sensitivity and specificity under operational conditions. Seven districts in the state of Sarawak, Malaysia, which are endemic for brugian filariasis, were used to determine the test sensitivity. Determination of specificity was performed in another state in Malaysia (Bachok, Kelantan) which is non-endemic for filariasis but endemic for soil-transmitted helminths. In Sarawak both the rapid test and thick blood smear preparation were performed in the field. The rapid test was interpreted on site, whereas blood smears were taken to the district health centres for staining and microscopic examination. Sensitivity of Brugia Rapid dipstick as compared with microscopy of thick blood smears was 87% (20/23; 95% CI: 66.4-97.2) whereas the specificity was 100% (512/512). The lower sensitivity of the test in the field than in laboratory evaluations (> or =95%), was probably due to the small number of microfilaraemic individuals, in addition to difficulties in performing the test in remote villages by field personnel. The overall prevalence of brugian filariasis as determined by the dipstick is 9.4% (95% CI: 8.2-0.5) while that determined by microscopy is 0.90% (95% CI: 0.5-1.3) thus the dipstick detected about 10 times more cases than microscopy. Equal percentages of adults and children were found to be positive by the dipstick whereas microscopy showed that the number of infected children was seven times less than infected adults. The rapid dipstick test was useful as a diagnostic tool for mapping and certification phases of the lymphatic filariasis elimination programme in B. malayi-endemic areas.
    Matched MeSH terms: Immunoassay/methods
  2. Eamsobhana P, Prasartvit A, Gan XX, Yong HS
    Trop Biomed, 2015 Mar;32(1):121-5.
    PMID: 25801261
    Angiostrongylus cantonensis is the most frequent cause of eosinophilic meningitis in humans in Thailand and worldwide. Because of difficulty of recovering the Angiostrongylus larvae from infected patients, detection of parasite-specific antibodies is used to support clinical diagnosis. This study tested serum samples from eosinophilic meningitis patients and individuals at risk of infection with A. cantonensis to evaluate a recently developed simple and rapid dot-immunogold filtration assay (DIGFA) for detection of specific antibodies against A. cantonensis. Purified 31-kDa glycoprotein of A. cantonensis and protein A colloidal gold conjugate were employed to detect the 31-kDa anti-A. cantonensis antibody in patients sera from the parasite endemic areas of northeast Thailand. The results were compared with those obtained by dot-blot enzyme-linked immunosorbent assay (ELISA) with 31-kDa A. cantonensis antigen. The overall positivity rate of DIGFA and dot-blot ELISA for A. cantonensis infection in 98 clinically diagnosed cases from three highly endemic districts in Khon Kaen province were 39.79% and 37.75%, respectively. Among 86 sera of subjects at risk of infection with A. cantonensis, 24.41% were positive by DIGFA and 23.25% by dot-blot ELISA. There were good correlation between the visual grading of DIGFA and dot-blot ELISA in both groups of defined sera. DIGFA is as sensitive and specific as dot-blot ELISA for confirming eosinophilic meningitis due to A. cantonensis infection, with advantages of simplicity, rapidity and without the use of specific and expensive equipment, and can be used in field settings.
    Matched MeSH terms: Immunoassay/methods
  3. Rahmah N, Taniawati S, Shenoy RK, Lim BH, Kumaraswami V, Anuar AK, et al.
    Trans R Soc Trop Med Hyg, 2002 1 31;95(6):601-4.
    PMID: 11816429
    A total of 753 serum samples from 6 institutions in 3 countries (Malaysia, Indonesia and India) were used to evaluate an immunochromatographic rapid dipstick test, Brugia Rapid, for diagnosis of Brugia malayi infection. The samples comprised sera from 207 microfilaria-positive individuals and 546 individuals from filaria non-endemic areas. The latter consisted of 70 individuals with soil-transmitted helminth infections, 68 with other helminth infections, 238 with protozoan infections, 12 with bacterial and viral infections and 158 healthy individuals. The dipstick is prepared with a goat anti-mouse antibody control line and a B. malayi recombinant-antigen test line. First, the dipstick is dipped into a well containing diluted patient serum, thus allowing specific anti-filarial antibody in the serum to react with the recombinant antigen. Then the dipstick is placed into an adjacent well containing reconstituted anti-human IgG4-gold. After 10 min, development of 2 red-purplish lines denotes a positive result and one line indicates a negative reaction. The overall results of the evaluation showed 97% sensitivity, 99% specificity, 97% positive predictive value and 99% negative predictive value. Brugia Rapid is thus a promising diagnostic tool for detection of B. malayi infection, and would be especially useful for the brugian filariasis elimination programme.
    Matched MeSH terms: Immunoassay/methods
  4. Rohani MY, Hasnidah D, Ong KH
    Malays J Pathol, 1998 Jun;20(1):31-3.
    PMID: 10879261
    A chromatographic immunoassay cholera antigen detection kit, the Cholera Spot test, was evaluated. The test was found to be specific with a sensitivity of 10(6) cfu/ml for the direct detection of V. cholerae in simulated stool specimens and 10 cfu/ml in simulated cotton-tipped swab specimens after overnight incubation in alkaline peptone water. This enables early recognition of cholera cases and their contacts so that prevention and control measures can be promptly instituted.
    Matched MeSH terms: Immunoassay/methods
  5. Mohd Zain R, Shaiful Bahrin NI, Ellan K, Thayan R
    Malays J Pathol, 2021 Dec;43(3):463-464.
    PMID: 34958069
    No abstract available.
    Matched MeSH terms: Immunoassay/methods*
  6. Yeang HY, Arif SA, Raulf-Heimsoth M, Loke YH, Sander I, Sulong SH, et al.
    J Allergy Clin Immunol, 2004 Sep;114(3):593-8.
    PMID: 15356563 DOI: 10.1016/j.jaci.2004.05.039
    BACKGROUND:
    Sensitization to natural rubber latex has been linked to proteins from medical latex gloves. Various assays to estimate the amount of residual allergenic proteins extractable from latex gloves to assess their potential exposure hazard have inherent weaknesses.

    OBJECTIVE:
    This investigation was aimed at developing 2-site immunoenzymetric assays and identifying appropriate protein markers to assess the allergenic potential of latex gloves.

    METHODS:
    The presence of 6 latex allergens--Hev b 1, 2, 3, 5, 6, and 13--was measured in a cross-section of commercial latex medical gloves by using monoclonal and polyclonal antibody-based 2-site immunoenzymetric assays. The overall allergenic potential of these gloves was assessed by IgE-inhibition assay. Stepwise multiple regression analyses were performed to identify marker allergens that best explained the variation in latex glove allergenicity.

    RESULTS:
    All 6 latex allergens were detected in at least some of the glove samples. Hev b 5 and Hev b 13 were identified as the marker allergens that combined best to explain the variation in the glove allergenicity. The significant multiple correlation (R=0.855) between these 2 markers and glove allergenic potency forms the basis of an assay to gauge latex glove allergenicity.

    CONCLUSION:
    The overall allergenic potential of latex gloves can be estimated by using Hev b 5 and Hev b 13 as indicator allergens. The correlation between glove allergenicity and the level of these allergens was maintained for low-protein gloves (<200 microg/g). This estimation of glove allergenicity was superior to that obtained by using total protein readings.
    Matched MeSH terms: Immunoassay/methods
  7. Jahangir MA, Gilani SJ, Muheem A, Jafar M, Aslam M, Ansari MT, et al.
    Pharm Nanotechnol, 2019;7(3):234-245.
    PMID: 31486752 DOI: 10.2174/2211738507666190429113906
    BACKGROUND: The amalgamation of biological sciences with nano stuff has significantly expedited the progress of biological strategies, greatly promoting practical applications in biomedical fields.

    OBJECTIVE: With distinct optical attributes (e.g., robust photostability, restricted emission spectra, tunable broad excitation, and high quantum output), fluorescent quantum dots (QDs) have been feasibly functionalized with manageable interfaces and considerably utilized as a new class of optical probe in biological investigations.

    METHODS: In this review article, we structured the current advancements in the preparation methods and attributes of QDs. Furthermore, we extend an overview of the outstanding potential of QDs for biomedical research and radical approaches to drug delivery.

    CONCLUSION: Notably, the applications of QDs as smart next-generation nanosystems for neuroscience and pharmacokinetic studies have been explained. Moreover, recent interests in the potential toxicity of QDs are also apprised, ranging from cell investigations to animal studies.

    Matched MeSH terms: Immunoassay/methods
  8. Ting HY, Sthaneshwar P, Bee PC, Shanmugam H, Lim M
    Pathology, 2019 Aug;51(5):507-511.
    PMID: 31253381 DOI: 10.1016/j.pathol.2019.04.002
    Serum protein (SPE) and immunofixation electrophoresis (IFE) have been extensively validated for the routine use of identifying, characterising and quantifying monoclonal proteins. However, accurate quantitation of IgA monoclonal proteins can be difficult when they migrate in to the β fraction, due to co-migration with transferrin and complement components. The heavy/light chain (HLC) immunoassay is an additional tool for measuring intact immunoglobulin monoclonal proteins. Therefore, we aimed to examine the clinical utility of the HLC assay for the disease monitoring of IgG and IgA multiple myeloma (MM) patients. A total of 177 samples from 30 MM patients (21 IgG and 9 IgA) were analysed retrospectively with median number of six follow up samples per patient (range 3-13). Serum free light chains (sFLC) and HLC were quantified using Freelite and Hevylite immunoassays. Details of M-protein concentration, β-globulin levels, total immunoglobulin levels and disease treatment response were obtained from the laboratory and patient information system. Passing-Bablok regression analysis was performed to compare (i) M-protein quantification with involved HLC (iHLC) and (ii) total immunoglobulin with summated HLC pairs for each immunoglobulin type (e.g., IgGκ+IgGλ). For 127 IgG MM samples, IgG iHLC levels showed a good correlation with SPE quantification (iHLC y=0.96x+4.9; r=0.917) and summated HLC showed a good correlation with total IgG concentration (summated HLC y=0.94x+5.74; r=0.91). In total, 95/127 (75%) IgG MM follow-up samples had an abnormal HLC ratio and 122/127 (96%) had a positive SPE, probably due to the lower sensitivity of HLC assay in detecting clonality in patients with IgG MM. Consistent with this, one patient assigned a very good partial response by International Myeloma Working Group criteria would be assigned a complete response based on HLC measurements. For 50 IgA MM samples, 42/50 (84%) had an abnormal HLC ratio. Conversely, 50/50 (100%) of M-proteins showed β fraction migration and were difficult to accurately quantify by SPE. Therefore, M-protein concentration and iHLC did not correlate as well in IgA MM (y=1.9x-8.4; r=0.8) compared to IgG MM. However, there was good correlation between total IgA and summated IgA HLC (IgAκ+IgAλ y=1.35x-0.33; r=0.95). Of the 8/50 (16%) IgA samples with a normal HLC ratio, 6/8 (75%) were consistent with the disease status being in complete remission. Interestingly, in one IgA MM patient, SPE and IFE were negative, but the serum FLC ratio and involved FLC were highly abnormal, consistent with the presence of light chain escape. Our data suggest HLC measurements could add value to the current disease monitoring of MM patients. In IgG MM patients, the M-protein level correlated well with HLC values. The HLC assay complements the serum FLC assay and is especially useful for monitoring of IgA MM patients who display M-proteins migrating in the β region on SPE.
    Matched MeSH terms: Immunoassay/methods*
  9. Fry SR, Meyer M, Semple MG, Simmons CP, Sekaran SD, Huang JX, et al.
    PLoS Negl Trop Dis, 2011 Jun;5(6):e1199.
    PMID: 21713023 DOI: 10.1371/journal.pntd.0001199
    BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1) has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum.
    AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test.
    METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples.
    KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6%) and 96% (95% CI: 92.2% to 99.8) respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1%) and 96.7% specificity (95% CI: 82.8% to 99.9%) compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers.
    CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.
    Matched MeSH terms: Immunoassay/methods
  10. Mohd Azmi UZ, Yusof NA, Abdullah J, Alang Ahmad SA, Mohd Faudzi FN, Ahmad Raston NH, et al.
    Mikrochim Acta, 2021 01 06;188(1):20.
    PMID: 33404779 DOI: 10.1007/s00604-020-04669-x
    An early detection of Mycobacterium tuberculosis is very important to reduce the number of fatal cases and allow for fast recovery. However, the interpretation of the result from smear microscopy requires skilled personnel due to the propensity of the method to produce false-negative results. In this work, a portable, rapid, and simple sandwich-type immunosensor reader has been developed that is able to detect the presence of M. tuberculosis in sputum samples. By using sandwich-type immunosensor, an anti-CFP10-ESAT6 antibody was immobilized onto the graphene/polyaniline (GP/PANI)-modified gold screen-printed electrode. After incubation with the target CFP10-ESAT6 antigen, the iron/gold magnetic nanoparticles (Fe3O4/Au MNPs) conjugated with anti-CFP10-ESAT6 antibody were used to complete the sandwich format. Differential pulse voltammetry (DPV) technique was used to detect the CFP10-ESAT6 antigen at the potential range of 0.0-1.0 V. The detection time is less than 2 h. Under optimal condition, CFP10-ESAT6 antigen was detected in a linear range from 10 to 500 ng mL-1 with a limit of detection at 1.5 ng mL-1. The method developed from this process was then integrated into a portable reader. The performance of the sensor was investigated and compared with the standard methods (culture and smear microscopy). It provides a good correlation (100% sensitivity and 91.7% specificity) with both methods of detection for M. tuberculosis in sputum samples henceforth, demonstrating the potential of the device as a more practical screening tool.Graphical abstract.
    Matched MeSH terms: Immunoassay/methods
  11. Jambari NN, Wang X, Alcocer M
    Methods Mol Biol, 2017;1592:129-137.
    PMID: 28315216 DOI: 10.1007/978-1-4939-6925-8_10
    Protein microarray is a miniaturized multi-analyte, solid-phased immunoassay where thousands of immobilized individual protein spots on a microscopic slide bind are bound to specific antibodies (immunoglobulins) from serum samples, which are then detected by fluorescent labeling. The image processing and pattern recognition are then quantitatively analyzed using advanced algorithms. Here, we describe the use of an in-house-produced complex protein microarray containing extracts and pure proteins that has been probed with antibodies present in the horse sera and detection by fluorophore-conjugated antibody and data analysis. The flexibility of the number and types of proteins that can be printed on the microarray allows different set of specific IgE immunoassay analysis to be carried out.
    Matched MeSH terms: Immunoassay/methods
  12. Bador KM, Intan S, Hussin S, Gafor AH
    Lupus, 2012 Oct;21(11):1172-7.
    PMID: 22652631 DOI: 10.1177/0961203312450085
    Previous studies in systemic lupus erythematosus (SLE) patients have produced conflicting results regarding the diagnostic utility of procalcitonin (PCT). The aim of this study was to determine predictive values of PCT and C-reactive protein (CRP) for bacterial infection in SLE patients.
    Matched MeSH terms: Immunoassay/methods
  13. Kilbourn AM, Godfrey HP, Cook RA, Calle PP, Bosi EJ, Bentley-Hibbert SI, et al.
    J. Wildl. Dis., 2001 Jan;37(1):65-71.
    PMID: 11272506
    Diagnosis of active mycobacterial disease in orangutans (Pongo pygmaeus) has been impeded by high levels of non-specific intradermal skin test reactivity to mycobacterial antigens. This may be due in part to cross reactivity between antigens, tuberculin concentrations used or other species-specific factors. Antigen 85 (Ag85) complex proteins are major secretory products of actively growing mycobacteria, and measurement of serum Ag85 could provide a method for determining active mycobacterial infections that was not dependent on host immunity. Serum Ag85 was measured by dot-immunobinding assay using monoclonal anti-Ag85, purified Ag85 standard and enhanced chemiluminescence technology in coded serum samples from 14 captive orangutans from a zoo in Colorado, 15 semi-captive orangutans in Malaysia, and 19 free-ranging wild orangutans in Malaysia. Orangutans from Colorado (USA) were culture negative for Mycobacterium tuberculosis and M. avium, although all had laboratory suspicion or evidence of mycobacterial infection; median serum Ag85 was 10 microU/ml (range, <0.25-630 microU/ml). Of the semi-captive orangutans, six were skin test reactive and two were culture positive for M. avium on necropsy. Median serum Ag85 for this group was 1,880 microU/ml (0.75-7,000 microU/ml), significantly higher than that of Colorado zoo or free-ranging Malaysian orangutans. Median serum Ag85 in the latter group was 125 microU/ml (range, 0.75-2,500 microU/ml). These data suggest that suggest that additional studies using more specific reagents and more samples from animals of known status are appropriate.
    Matched MeSH terms: Immunoassay/methods
  14. Chin CF, Ler LW, Choong YS, Ong EB, Ismail A, Tye GJ, et al.
    J Microbiol Methods, 2016 Jan;120:6-14.
    PMID: 26581498 DOI: 10.1016/j.mimet.2015.11.007
    Antibody phage display panning involves the enrichment of antibodies against specific targets by affinity. In recent years, several new methods for panning have been introduced to accommodate the growing application of antibody phage display. The present work is concerned with the application of streptavidin mass spectrometry immunoassay (MSIA™) Disposable Automation Research Tips (D.A.R.T's®) for antibody phage display. The system was initially designed to isolate antigens by affinity selection for mass spectrometry analysis. The streptavidin MSIA™ D.A.R.T's® system allows for easy attachment of biotinylated target antigens on the solid surface for presentation to the phage library. As proof-of-concept, a domain antibody library was passed through the tips attached with the Hemolysin E antigen. After binding and washing, the bound phages were eluted via standard acid dissociation and the phages were rescued for subsequent panning rounds. Polyclonal enrichment was observed for three rounds of panning with five monoclonal domain antibodies identified. The proposed method allows for a convenient, rapid and semi-automated alternative to conventional antibody panning strategies.
    Matched MeSH terms: Immunoassay/methods*
  15. Ross RS, Viazov S, Schmitt U, Schmolke S, Tacke M, Ofenloch-Haehnle B, et al.
    J Med Virol, 1998 Feb;54(2):103-6.
    PMID: 9496367
    Since the identification of the new human virus, GB virus C (GBV-C)/hepatitis G-virus (HGV), in 1995/1996, reverse transcription polymerase chain reaction remained the sole available diagnostic tool for GBV-C/HGV infection. Recently, a serologic test based on the detection of antibodies to the putative envelope protein 2 (anti-E2) has been introduced. We used this assay for a seroepidemiological survey including 3,314 healthy individuals from different parts of the world, 123 patients from Germany who were suspected to have an increased risk of acquiring GBV-C/HGV infection, 128 multiple organ donors, and 90 GBV-C/HGV RNA positive persons. In European countries, anti-E2 seropositivity ranged from 10.9% (Germany) to 15.3% (Austria). In South Africa (20.3%) and Brazil (19.5%), even higher anti-E2 prevalence rates were recorded. In Asian countries like Bhutan (3.9%), Malaysia (6.3%), and the Philippines (2.7%), anti-E2 positivity was significantly lower. GBV-C/HGV anti-E2 prevalence in potential "risk groups," i.e., patients on hemodialysis and renal transplant recipients, did not vary significantly from anti-E2 seroprevalence in German blood donors. Anti-E2 and GBV-C/HGV RNA were found to be mutually exclusive, confirming the notion that anti-E2 has to be considered as a marker of past infection.
    Matched MeSH terms: Immunoassay/methods
  16. Chong YM, Tan XH, Hooi PS, Lee LM, Sam IC, Chan YF
    J Med Virol, 2019 08;91(8):1562-1565.
    PMID: 31032971 DOI: 10.1002/jmv.25495
    Rapid diagnosis of influenza is important for early treatment and institution of control measures. In developing tropical countries such as Malaysia, influenza occurs all year round, but molecular assays and conventional techniques (such as immunofluorescence and culture) for diagnosis are not widely available. Rapid influenza diagnostic tests (RIDTs) may be useful in this setting. A total of 552 fresh respiratory specimens were assessed from patients with respiratory symptoms at a teaching hospital in Kuala Lumpur, Malaysia from November 2017 to March 2018. Two digital immunoassays (DIAs), STANDARD F Influenza A/B Fluorescence Immunoassay (STANDARD F) and Sofia Influenza A + B Fluorescence Immunoassay (Sofia) and one conventional RIDT (immunochromatographic assay), SD Bioline Influenza Ag A/B/A(H1N1) Pandemic rapid test kit (SD Bioline) were evaluated in comparison with a WHO-recommended reverse transcription quantitative PCR (RT-qPCR). Of the 552 samples, influenza A virus was detected in 47 (8.5%) and influenza B virus in 7 (1.3%). The digital immunoassays STANDARD F and Sofia had significantly higher overall sensitivity rates (71.7% and 70.6%, respectively) than the conventional RIDT SD Bioline and immunofluorescence/viral culture (55.8% and 52.8%, respectively). Sensitivity rates were higher for influenza A than influenza B, and specificity rates were uniformly high, ranging from 98% to 100%. Digital readout RIDTs can be used in tropical settings with year-round influenza if PCR is unavailable.
    Matched MeSH terms: Immunoassay/methods*
  17. Alia SN, Joseph N, Philip N, Azhari NN, Garba B, Masri SN, et al.
    J Infect Public Health, 2018 11 27;12(2):263-269.
    PMID: 30502041 DOI: 10.1016/j.jiph.2018.10.137
    BACKGROUND: Leptospirosis is often misdiagnosed with several other tropical febrile illnesses in Malaysia due to similarities in clinical manifestations. Although treatment regimens could be started based on clinical judgments, early diagnosis has become paramount as a guide to chemotherapeutic interventions. Confirmed laboratory diagnosis through MAT or PCR is time consuming and usually available only in reference laboratories and not practical in healthcare settings. Rapid and easy to perform diagnostic tests are widely used in these settings as the point of care diagnosis. The present study was undertaken to compare the diagnostic performance of two IgM based immunodiagnostic assay kits for acute leptospirosis.

    METHODS: A total of 50 serum samples were collected from patients clinically suspected for acute leptospirosis on admission in the Hospital Serdang, from June 2016 to June 2017. All the samples were subjected to MAT, lipL32 PCR and the two rapid tests (Leptocheck-WB and ImmuneMed Leptospira IgM Duo Rapid test).

    RESULTS: Out of the 50 clinically suspected patients sampled, 19 were confirmed positive for leptospirosis. Six (12%) were confirmed by MAT and 13 (26%) by PCR. Similarly, of the 50 clinically suspected cases, 17 (34%) showed positivity for Leptocheck-WB and 7 (14%) for ImmuneMed Leptospira IgM Duo Rapid test. The overall sensitivity and specificity was 47.37% and 80.65% for Leptocheck-WB, and 21.05% and 90.32% for ImmuneMed Leptospira IgM Duo Rapid test. In another set of previously confirmed MAT positive samples (1:400-1:3600) obtained from a reference laboratory, Leptocheck-WB showed higher sensitivity (90.72%) than ImmuneMed Leptospira IgM Duo Rapid test (40.21%), and comparable specificity for ImmuneMed Leptospira IgM Duo Rapid test (88.89%) and Leptocheck-WB (82.86%).

    CONCLUSION: The sensitivity was higher for Leptocheck-WB and had a comparable specificity with ImmuneMed Leptospira IgM Duo Rapid test. Therefore, based on the present study, Leptocheck-WB is found to be a more sensitive rapid immunodiagnostic test for acute leptospirosis screening in hospital settings.

    Matched MeSH terms: Immunoassay/methods*
  18. Ahmad AL, Low SC, Shukor SR, Ismail A
    J Immunoassay Immunochem, 2012 Jan;33(1):48-58.
    PMID: 22181820 DOI: 10.1080/15321819.2011.591479
    This study was aimed at gaining a quantitative understanding of the effect of protein quantity and membrane pore structure on protein immobilization. The concentration of immobilized protein was measured by staining with Ponceau S and measuring its color intensity. In this study, both membrane morphology and the quantity of deposited protein significantly influenced the quantity of protein immobilization on the membrane surface. The sharpness and intensity of the red protein spots varied depending on the membrane pore structure, indicating a dependence of protein immobilization on this factor. Membranes with smaller pores resulted in a higher color density, corresponding to enhanced protein immobilization and an increased assay sensitivity level. An increased of immobilized volume has a significant jagged outline on the protein spot but, conversely, no difference in binding capacity.
    Matched MeSH terms: Immunoassay/methods*
  19. Liew WP, Sabran MR
    J Food Drug Anal, 2022 Nov 23;30(4):549-561.
    PMID: 36753365 DOI: 10.38212/2224-6614.3430
    The co-occurrence and accumulation of mycotoxin in food and feed constitutes a major issue to food safety, food security, and public health. Accurate and sensitive mycotoxins analysis can avoid toxin contamination as well as reduce food wastage caused by false positive results. This mini review focuses on the recent advance in detection methods for multiple mycotoxins, which mainly depends on immunoassay technologies. Advance immunoassay technologies integrated in mycotoxin analysis enable simultaneous detection of multiple mycotoxins and enhance the outcomes' quality. It highlights toxicogenomic as novel approach for hazard assessment by utilizing computational methods to map molecular events and biological processes. Indeed, toxicogenomic is a powerful tool to understand health effects from mycotoxin exposure as it offers insight on the mechanisms by which mycotoxins exposures cause diseases.
    Matched MeSH terms: Immunoassay/methods
  20. Bhewa Y, Hilmi I, Cheah PL, Navaratnam P, Goh KL
    J Dig Dis, 2007 Nov;8(4):207-10.
    PMID: 17970878
    Although well established in the West, stool antigen tests (SAT) are not widely used in Asia. Data on the accuracy of this test in Asia is sparse and, to date, there have been no studies looking at the more refined monoclonal SAT. The aim of this study is to validate the diagnostic accuracy of a stool antigen test, Hp STAR, for the detection of Helicobacter pylori.
    Matched MeSH terms: Immunoassay/methods*