Displaying publications 1 - 20 of 91 in total

Abstract:
Sort:
  1. Azudin K, Gan KB, Jaafar R, Ja'afar MH
    Sensors (Basel), 2023 Jul 18;23(14).
    PMID: 37514778 DOI: 10.3390/s23146484
    Not long ago, hearables paved the way for biosensing, fitness, and healthcare monitoring. Smart earbuds today are not only producing sound but also monitoring vital signs. Reliable determination of cardiovascular and pulmonary system information can explore the use of hearables for physiological monitoring. Recent research shows that photoplethysmography (PPG) signals not only contain details on oxygen saturation level (SPO2) but also carry more physiological information including pulse rate, respiration rate, blood pressure, and arterial-related information. The analysis of the PPG signal from the ear has proven to be reliable and accurate in the research setting. (1) Background: The present integrative review explores the existing literature on an in-ear PPG signal and its application. This review aims to identify the current technology and usage of in-ear PPG and existing evidence on in-ear PPG in physiological monitoring. This review also analyzes in-ear (PPG) measurement configuration and principle, waveform characteristics, processing technology, and feature extraction characteristics. (2) Methods: We performed a comprehensive search to discover relevant in-ear PPG articles published until December 2022. The following electronic databases: Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, Scopus, Web of Science, and PubMed were utilized to conduct the studies addressing the evidence of in-ear PPG in physiological monitoring. (3) Results: Fourteen studies were identified but nine studies were finalized. Eight studies were on different principles and configurations of hearable PPG, and eight studies were on processing technology and feature extraction and its evidence in in-ear physiological monitoring. We also highlighted the limitations and challenges of using in-ear PPG in physiological monitoring. (4) Conclusions: The available evidence has revealed the future of in-ear PPG in physiological monitoring. We have also analyzed the potential limitation and challenges that in-ear PPG will face in processing the signal.
    Matched MeSH terms: Monitoring, Physiologic
  2. Shivaraja TR, Remli R, Kamal N, Wan Zaidi WA, Chellappan K
    Sensors (Basel), 2023 Mar 31;23(7).
    PMID: 37050713 DOI: 10.3390/s23073654
    Ambulatory EEGs began emerging in the healthcare industry over the years, setting a new norm for long-term monitoring services. The present devices in the market are neither meant for remote monitoring due to their technical complexity nor for meeting clinical setting needs in epilepsy patient monitoring. In this paper, we propose an ambulatory EEG device, OptiEEG, that has low setup complexity, for the remote EEG monitoring of epilepsy patients. OptiEEG's signal quality was compared with a gold standard clinical device, Natus. The experiment between OptiEEG and Natus included three different tests: eye open/close (EOC); hyperventilation (HV); and photic stimulation (PS). Statistical and wavelet analysis of retrieved data were presented when evaluating the performance of OptiEEG. The SNR and PSNR of OptiEEG were slightly lower than Natus, but within an acceptable bound. The standard deviations of MSE for both devices were almost in a similar range for the three tests. The frequency band energy analysis is consistent between the two devices. A rhythmic slowdown of theta and delta was observed in HV, whereas photic driving was observed during PS in both devices. The results validated the performance of OptiEEG as an acceptable EEG device for remote monitoring away from clinical environments.
    Matched MeSH terms: Monitoring, Physiologic
  3. Safi A, Ahmad Z, Jehangiri AI, Latip R, Zaman SKU, Khan MA, et al.
    Sensors (Basel), 2022 Nov 01;22(21).
    PMID: 36366109 DOI: 10.3390/s22218411
    In recent years, fire detection technologies have helped safeguard lives and property from hazards. Early fire warning methods, such as smoke or gas sensors, are ineffectual. Many fires have caused deaths and property damage. IoT is a fast-growing technology. It contains equipment, buildings, electrical systems, vehicles, and everyday things with computing and sensing capabilities. These objects can be managed and monitored remotely as they are connected to the Internet. In the Internet of Things concept, low-power devices like sensors and controllers are linked together using the concept of Low Power Wide Area Network (LPWAN). Long Range Wide Area Network (LoRaWAN) is an LPWAN product used on the Internet of Things (IoT). It is well suited for networks of things connected to the Internet, where terminals send a minute amount of sensor data over large distances, providing the end terminals with battery lifetimes of years. In this article, we design and implement a LoRaWAN-based system for smart building fire detection and prevention, not reliant upon Wireless Fidelity (Wi-Fi) connection. A LoRa node with a combination of sensors can detect smoke, gas, Liquefied Petroleum Gas (LPG), propane, methane, hydrogen, alcohol, temperature, and humidity. We developed the system in a real-world environment utilizing Wi-Fi Lora 32 boards. The performance is evaluated considering the response time and overall network delay. The tests are carried out in different lengths (0-600 m) and heights above the ground (0-2 m) in an open environment and indoor (1st Floor-3rd floor) environment. We observed that the proposed system outperformed in sensing and data transfer from sensing nodes to the controller boards.
    Matched MeSH terms: Monitoring, Physiologic/methods
  4. Ibrahim NFA, Sabani N, Johari S, Manaf AA, Wahab AA, Zakaria Z, et al.
    Sensors (Basel), 2022 Oct 10;22(19).
    PMID: 36236769 DOI: 10.3390/s22197670
    Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte's response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.
    Matched MeSH terms: Monitoring, Physiologic
  5. Yang Y, Wei X, Zhang N, Zheng J, Chen X, Wen Q, et al.
    Nat Commun, 2021 08 12;12(1):4876.
    PMID: 34385436 DOI: 10.1038/s41467-021-25075-8
    While the printed circuit board (PCB) has been widely considered as the building block of integrated electronics, the world is switching to pursue new ways of merging integrated electronic circuits with textiles to create flexible and wearable devices. Herein, as an alternative for PCB, we described a non-printed integrated-circuit textile (NIT) for biomedical and theranostic application via a weaving method. All the devices are built as fibers or interlaced nodes and woven into a deformable textile integrated circuit. Built on an electrochemical gating principle, the fiber-woven-type transistors exhibit superior bending or stretching robustness, and were woven as a textile logical computing module to distinguish different emergencies. A fiber-type sweat sensor was woven with strain and light sensors fibers for simultaneously monitoring body health and the environment. With a photo-rechargeable energy textile based on a detailed power consumption analysis, the woven circuit textile is completely self-powered and capable of both wireless biomedical monitoring and early warning. The NIT could be used as a 24/7 private AI "nurse" for routine healthcare, diabetes monitoring, or emergencies such as hypoglycemia, metabolic alkalosis, and even COVID-19 patient care, a potential future on-body AI hardware and possibly a forerunner to fabric-like computers.
    Matched MeSH terms: Monitoring, Physiologic/instrumentation; Monitoring, Physiologic/methods
  6. Márquez-Sánchez S, Campero-Jurado I, Robles-Camarillo D, Rodríguez S, Corchado-Rodríguez JM
    Sensors (Basel), 2021 May 12;21(10).
    PMID: 34066186 DOI: 10.3390/s21103372
    Wearable technologies are becoming a profitable means of monitoring a person's health state, such as heart rate and physical activity. The use of the smartwatch is becoming consolidated, not only as a novelty but also as a very useful tool for daily use. In addition, other devices, such as helmets or belts, are beneficial for monitoring workers and the early detection of any anomaly. They can provide valuable information, especially in work environments, where they help reduce the rate of accidents and occupational diseases, which makes them powerful Personal Protective Equipment (PPE). The constant monitoring of the worker's health can be done in real-time, through temperature, falls, noise, impacts, or heart rate meters, activating an audible and vibrating alarm when an anomaly is detected. The gathered information is transmitted to a server in charge of collecting and processing it. In the first place, this paper provides an exhaustive review of the state of the art on works related to electronics for human activity behavior. After that, a smart multisensory bracelet, combined with other devices, developed a control platform that can improve operators' security in the working environment. Artificial Intelligence and the Internet of Things (AIoT) bring together the information to improve safety on construction sites, power stations, power lines, etc. Real-time and historic data is used to monitor operators' health and a hybrid system between Gaussian Mixture Model and Human Activity Classification. That is, our contribution is also founded on the use of two machine learning models, one based on unsupervised learning and the other one supervised. Where the GMM gave us a performance of 80%, 85%, 70%, and 80% for the 4 classes classified in real time, the LSTM obtained a result under the confusion matrix of 0.769, 0.892, and 0.921 for the carrying-displacing, falls, and walking-standing activities, respectively. This information was sent in real time through the platform that has been used to analyze and process the data in an alarm system.
    Matched MeSH terms: Monitoring, Physiologic
  7. Venugopal A, Mohammad R, Koslan MFS, Sayd Bakar SR, Ali A
    Materials (Basel), 2021 May 06;14(9).
    PMID: 34066461 DOI: 10.3390/ma14092414
    The environmental condition in which the Royal Malaysian Airforce is currently operating its aircraft is prone to corrosion. This is due to the high relative humidity and temperature. With most of its aircraft being in the legacy aircraft era, the aircraft's main construction consists of the aluminium 2024 material. However, this material is prone to corrosion, thus reducing fatigue life and leading to fatigue failure. Using the concept of either Safe Life or Damage Tolerance as its fatigue design philosophy, the RMAF adopts the Aircraft Structure Integrity Program (ASIP) to monitor its structural integrity. With the current problem of not having the structural limitation on corrosion-damaged structure, the RMAF has embarked on its fatigue testing method. Finite Element (FE) studies and flight tests were conducted, and the outcome is summarized. The conclusion is that the longeron tested on the aircraft can withstand the operational load, and its yield strength is below the ultimate yield strength of the material. These research outcomes will also enhance the ASIP for other aircraft platforms in the RMAF fleet for its structure life assessment or service life extension program.
    Matched MeSH terms: Monitoring, Physiologic
  8. Mishu MK, Rokonuzzaman M, Pasupuleti J, Shakeri M, Rahman KS, Binzaid S, et al.
    Sensors (Basel), 2021 Apr 08;21(8).
    PMID: 33917665 DOI: 10.3390/s21082604
    In this paper, an integrated thermoelectric (TE) and photovoltaic (PV) hybrid energy harvesting system (HEHS) is proposed for self-powered internet of thing (IoT)-enabled wireless sensor networks (WSNs). The proposed system can run at a minimum of 0.8 V input voltage under indoor light illumination of at least 50 lux and a minimum temperature difference, ∆T = 5 °C. At the lowest illumination and temperature difference, the device can deliver 0.14 W of power. At the highest illumination of 200 lux and ∆T = 13 °C, the device can deliver 2.13 W. The developed HEHS can charge a 0.47 F, 5.5 V supercapacitor (SC) up to 4.12 V at the combined input voltage of 3.2 V within 17 s. In the absence of any energy sources, the designed device can back up the complete system for 92 s. The sensors can successfully send 39 data string to the webserver within this time at a two-second data transmission interval. A message queuing telemetry transport (MQTT) based IoT framework with a customised smartphone application 'MQTT dashboard' is developed and integrated with an ESP32 Wi-Fi module to transmit, store, and monitor the sensors data over time. This research, therefore, opens up new prospects for self-powered autonomous IoT sensor systems under fluctuating environments and energy harvesting regimes, however, utilising available atmospheric light and thermal energy.
    Matched MeSH terms: Monitoring, Physiologic
  9. Mondal H, Mondal S
    Malays Fam Physician, 2021 Mar 25;16(1):8-14.
    PMID: 33948137 DOI: 10.51866/rv1097
    Home health monitoring devices are consumer-grade devices that help to monitor the health of individuals at home. These devices are usually low-cost and easily procurable, and they can be operated by patients or their caretakers with minimal training. However, improper usage of these devices may provide erroneous results, which can lead to an unnecessary hospital visit or teleconsultation. In this article, we discuss the basic technology and proper usage of some of these devices, namely automatic blood pressure monitors, blood glucose monitors, body fat monitors, pulse oximeters, electrocardiographs, digital thermometers, and infrared thermometers. This brief document intends to help primary health care professionals and their patients use these devices.
    Matched MeSH terms: Monitoring, Physiologic
  10. Alahnomi RA, Zakaria Z, Yussof ZM, Althuwayb AA, Alhegazi A, Alsariera H, et al.
    Sensors (Basel), 2021 Mar 24;21(7).
    PMID: 33804904 DOI: 10.3390/s21072267
    Recent developments in the field of microwave planar sensors have led to a renewed interest in industrial, chemical, biological and medical applications that are capable of performing real-time and non-invasive measurement of material properties. Among the plausible advantages of microwave planar sensors is that they have a compact size, a low cost and the ease of fabrication and integration compared to prevailing sensors. However, some of their main drawbacks can be considered that restrict their usage and limit the range of applications such as their sensitivity and selectivity. The development of high-sensitivity microwave planar sensors is required for highly accurate complex permittivity measurements to monitor the small variations among different material samples. Therefore, the purpose of this paper is to review recent research on the development of microwave planar sensors and further challenges of their sensitivity and selectivity. Furthermore, the techniques of the complex permittivity extraction (real and imaginary parts) are discussed based on the different approaches of mathematical models. The outcomes of this review may facilitate improvements of and an alternative solution for the enhancement of microwave planar sensors' normalized sensitivity for material characterization, especially in biochemical and beverage industry applications.
    Matched MeSH terms: Monitoring, Physiologic
  11. Ran Z, Wu K, Matsuoka K, Jeen YT, Wei SC, Ahuja V, et al.
    J Gastroenterol Hepatol, 2021 Mar;36(3):637-645.
    PMID: 32672839 DOI: 10.1111/jgh.15185
    Inflammatory bowel disease (IBD) has increased in incidence and prevalence in Asian countries since the end of the 20th century. Moreover, differences in the cause, phenotypes, and natural history of IBD between the East and West have been recognized. Therefore, the Asian Organization for Crohn's and Colitis and the Asia Pacific Association of Gastroenterology have established recommendations on medical management of IBD in Asia. Initially, the committee members drafted 40 recommendations, which were then assessed according to Grading of Recommendations Assessment, Development and Evaluation. Eight statements were rejected as this indicated that consensus had not been reached. The recommendations encompass pretreatment evaluation; medical management of active IBD; medical management of IBD in remission; management of IBD during the periconception period and pregnancy; surveillance strategies for colitis-associated cancer; monitoring side effects of thiopurines and methotrexate; and infections in IBD.
    Matched MeSH terms: Monitoring, Physiologic*
  12. Mat Zin S, Md Rasib SZ, Suhaimi FM, Mariatti M
    Biomed Eng Online, 2021 Feb 06;20(1):17.
    PMID: 33549118 DOI: 10.1186/s12938-021-00854-y
    The tongue and hard palate play an essential role in the production of sound during continuous speech. Appropriate tongue and hard palate contacts will ensure proper sound production. Electropalatography, also known as EPG, is a device that can be used to identify the location of the tongue and hard palate contact. It can also be used by a speech therapist to help patients who have a speech disorder. Among the group with the disease are cleft palate, Down syndrome, glossectomy, and autism patients. Besides identifying the contact location, EPG is a useful medical device that has been continuously developed based on the patient's needs and treatment advancement. This article reviews the technology of electropalatography since the early introduction of the device. It also discusses the development process and the drawbacks of the previous EPG systems, resulting in the EPG's upgraded system and technology. This review suggests additional features that can be useful for the future development of the EPG. The latest technology can be incorporated into the EPG system to provide a more convenient method. There are some elements to be considered in the development of EPG's new technology that were discussed in this study. The elements are essential to provide more convenience for the patient during speech therapy. New technology can accelerate the growth of medical devices, particularly on the development of speech therapy equipment that should be based on the latest technological advancements available. Thus, the advanced EPG system suggested in this article may expand the usage of the EPG and serve as a tool to provide speech therapy treatment services and not limited to monitoring only.
    Matched MeSH terms: Monitoring, Physiologic/methods*
  13. Hasan SS, Kow CS, Bain A, Kavanagh S, Merchant HA, Hadi MA
    Expert Opin Pharmacother, 2021 Feb;22(2):229-240.
    PMID: 33054481 DOI: 10.1080/14656566.2020.1837114
    INTRODUCTION: Diabetes mellitus is one of the most prevalent comorbidities identified in patients with coronavirus disease 2019 (COVID-19). This article aims to discuss the pharmacotherapeutic considerations for the management of diabetes in hospitalized patients with COVID-19.

    AREAS COVERED: We discussed various aspects of pharmacotherapeutic management in hospitalized patients with COVID-19: (i) susceptibility and severity of COVID-19 among individuals with diabetes, (ii) glycemic goals for hospitalized patients with COVID-19 and concurrent diabetes, (iii) pharmacological treatment considerations for hospitalized patients with COVID-19 and concurrent diabetes.

    EXPERT OPINION: The glycemic goals in patients with COVID-19 and concurrent type 1 (T1DM) or type 2 diabetes (T2DM) are to avoid disruption of stable metabolic state, maintain optimal glycemic control, and prevent adverse glycemic events. Patients with T1DM require insulin therapy at all times to prevent ketosis. The management strategies for patients with T2DM include temporary discontinuation of certain oral antidiabetic agents and consideration for insulin therapy. Patients with T2DM who are relatively stable and able to eat regularly may continue with oral antidiabetic agents if glycemic control is satisfactory. Hyperglycemia may develop in patients with systemic corticosteroid treatment and should be managed upon accordingly.

    Matched MeSH terms: Monitoring, Physiologic
  14. Algamili AS, Khir MHM, Dennis JO, Ahmed AY, Alabsi SS, Ba Hashwan SS, et al.
    Nanoscale Res Lett, 2021 Jan 26;16(1):16.
    PMID: 33496852 DOI: 10.1186/s11671-021-03481-7
    Over the last couple of decades, the advancement in Microelectromechanical System (MEMS) devices is highly demanded for integrating the economically miniaturized sensors with fabricating technology. A sensor is a system that detects and responds to multiple physical inputs and converting them into analogue or digital forms. The sensor transforms these variations into a form which can be utilized as a marker to monitor the device variable. MEMS exhibits excellent feasibility in miniaturization sensors due to its small dimension, low power consumption, superior performance, and, batch-fabrication. This article presents the recent developments in standard actuation and sensing mechanisms that can serve MEMS-based devices, which is expected to revolutionize almost many product categories in the current era. The featured principles of actuating, sensing mechanisms and real-life applications have also been discussed. Proper understanding of the actuating and sensing mechanisms for the MEMS-based devices can play a vital role in effective selection for novel and complex application design.
    Matched MeSH terms: Monitoring, Physiologic
  15. Wong A, Abu Bakar MZ
    Am J Otolaryngol, 2021 01 04;42(2):102869.
    PMID: 33429183 DOI: 10.1016/j.amjoto.2020.102869
    PURPOSE: The nasocardiac reflex is known but not well researched. We aimed to ascertain the electrocardiographic features of the reflex and to chronologically map the heart rhythm dynamics during nasoendoscopy. We also intended to identify variables that could potentially affect the occurrence of this reflex.

    MATERIAL AND METHODS: A prospective, quasi-experimental physiological study. Selected healthy subjects were observed electrocardiographically for 60 s continuously in three equal phases of 20 s each - baseline phase, nasoendoscopic phase, and recovery phase (post-nasoendoscopy). Heart rate fluctuations were charted, followed by identification of a positive nasocardiac reflex group of subjects and a negative group. Analyses against multiple variables were done.

    RESULTS: A total of 53 subjects were analysed. Heart rate during the baseline phase was 81.0 ± 9.9, nasoendoscopic phase was 72.7 ± 10.1, and recovery phase was 75.2 ± 9.6. Sixteen subjects (30.2%) had a positive nasocardiac reflex, and they remained in sinus rhythm with no occurrences of skipped beats, atrioventricular blocks or asystoles. One subject (1.9%) developed temporary ectopic premature ventricular contractions after nasoendoscopy. No variables were found affecting the incidence of a nasocardiac reflex in our study.

    CONCLUSIONS: The pattern of heart rate dynamics was consistent as heart rates drop rapidly upon endoscope insertion and recover in some measure after its withdrawal. Although all our subjects remained asymptomatic, clinicians should not overlook the risks of a severe nasocardiac reflex when performing nasoendoscopy. We recommend that electrical cardiac monitoring be part of the management of vasovagal responses during in-office endonasal procedures.

    Matched MeSH terms: Monitoring, Physiologic/methods*
  16. Kedung Fletcher, Anding Nyuak, Tan Phei Yee
    MyJurnal
    There is lacking technology application in black pepper farming to automate daily routine activities in monitoring black pepper vines growth and nutrient need. With the revolution of Industry 4.0 (IR4.0), and tremendous improvement in the internet of things (IoT), the application of precision agriculture to pepper farming is a thing to consider for its benefit. This paper to explore the use of IoT to monitor fertilizer requirement for pepper vines using pH sensor. The pH sensor attached to Raspberry Pi 3 will be collecting the data and forwarding it to the cloud database for farmer reference and take decision based on data presented in form of a digital report from the database. The Python environment provides the space for coding in Raspberry Pi. SQL and PHP software is used to design the user interface and data management in the relational database management system. The information about pH provides a better understanding of how pH parameter affects the growth of pepper vines. The farmer will be able to access the information anywhere and anytime. Therefore, our proposed system will greatly help the pepper farmers in Sarawak in managing the usage of fertilizer as a way to minimize farm inputs, thus increase their profit.
    Matched MeSH terms: Monitoring, Physiologic
  17. Hisham A, Hafizuddin Bin Salleh M, Ibrahim S, Mohd Yussof SJ
    Int Wound J, 2020 Aug;17(4):1097-1098.
    PMID: 32333718 DOI: 10.1111/iwj.13375
    Matched MeSH terms: Monitoring, Physiologic/adverse effects*
  18. Bibbo D, Klinkovsky T, Penhaker M, Kudrna P, Peter L, Augustynek M, et al.
    Sensors (Basel), 2020 Jul 25;20(15).
    PMID: 32722397 DOI: 10.3390/s20154139
    In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother's heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within ±3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses.
    Matched MeSH terms: Monitoring, Physiologic
  19. Poh AH, Adikan FRM, Moghavvemi M
    Med Biol Eng Comput, 2020 Jun;58(6):1159-1175.
    PMID: 32319030 DOI: 10.1007/s11517-019-02077-9
    The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a closer look into applications potentially for detecting or monitoring diseases. One of the challenges in this field is in establishing a reference for applications which correspond to certain bandwidths. This article reviews the scope on past research on skin spectroscopy, and the clinical aspects which have or may have applications on disease detection or enhancing diagnostics. A summary is supplied on the technicalities surrounding the measurements reported in literature, focused towards the wavelength-dependent applications in themes central to the respective research. Analytics on the topology of the papers' data cited in this work is also provided for a statistical perspective. In short, this paper strives to immediately inform the reader with possible applications via the spectroscopic devices at hand. Graphical Abstract .
    Matched MeSH terms: Monitoring, Physiologic/methods
  20. Wolkow AP, Rajaratnam SMW, Wilkinson V, Shee D, Baker A, Lillington T, et al.
    Sleep Health, 2020 06;6(3):366-373.
    PMID: 32340910 DOI: 10.1016/j.sleh.2020.03.005
    OBJECTIVES: This study examined the influence of a wrist-worn heart rate drowsiness detection device on heavy vehicle driver safety and sleep and its ability to predict driving events under naturalistic conditions.

    DESIGN: Prospective, non-randomized trial.

    SETTING: Naturalistic driving in Malaysia.

    PARTICIPANTS: Heavy vehicle drivers in Malaysia were assigned to the Device (n = 25) or Control condition (n = 34).

    INTERVENTION: Both conditions were monitored for driving events at work over 4-weeks in Phase 1, and 12-weeks in Phase 2. In Phase 1, the Device condition wore the device operated in the silent mode (i.e., no drowsiness alerts) to examine the accuracy of the device in predicting driving events. In Phase 2, the Device condition wore the device in the active mode to examine if drowsiness alerts from the device influenced the rate of driving events (compared to Phase 1).

    MEASUREMENTS: All participants were monitored for harsh braking and harsh acceleration driving events and self-reported sleep duration and sleepiness daily.

    RESULTS: There was a significant decrease in the rate of harsh braking events (Rate ratio = 0.48, p 

    Matched MeSH terms: Monitoring, Physiologic/instrumentation*