Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Garweg C, Khelae SK, Chan JYS, Chinitz L, Ritter P, Johansen JB, et al.
    J Cardiovasc Electrophysiol, 2021 07;32(7):1947-1957.
    PMID: 33928713 DOI: 10.1111/jce.15061
    INTRODUCTION: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio-ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study.

    METHODS: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode-switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)-40 depending upon AVC status.

    RESULTS: Forty-two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI-40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing.

    CONCLUSION: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AV block. No pacing safety issues were observed during arrhythmias.

    Matched MeSH terms: Pacemaker, Artificial*
  2. Garweg C, Khelae SK, Steinwender C, Chan JYS, Ritter P, Johansen JB, et al.
    Heart Rhythm, 2020 12;17(12):2037-2045.
    PMID: 32717315 DOI: 10.1016/j.hrthm.2020.07.024
    BACKGROUND: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%. Previously, low amplitude of the Micra-sensed atrial signal (A4) was observed to be a factor of low AVS.

    OBJECTIVE: The purpose of this study was to identify predictors of A4 amplitude and high AVS.

    METHODS: We analyzed 64 patients enrolled in MARVEL 2 who had visible P waves on electrocardiogram for assessing A4 amplitude and 40 patients with third-degree AV block for assessing AVS at rest. High AVS was defined as >90% correct atrial-triggered ventricular pacing. The association between clinical factors and echocardiographic parameters with A4 amplitude was investigated using a multivariable model with lasso variable selection. Variables associated with A4 amplitude together with premature ventricular contraction burden, sinus rate, and sinus rate variability (standard deviation of successive differences of P-P intervals [SDSD]) were assessed for association with AVS.

    RESULTS: In univariate analysis, low A4 amplitude was inversely related to atrial function assessed by E/A ratio and e'/a' ratio, and was directly related to atrial contraction excursion (ACE) and atrial strain (Ɛa) on echocardiography (all P ≤.05). The multivariable lasso regression model found coronary artery bypass graft history, E/A ratio, ACE, and Ɛa were associated with low A4 amplitude. E/A ratio and SDSD were multivariable predictors of high AVS, with >90% probability if E/A <0.94 and SDSD <5 bpm.

    CONCLUSION: Clinical parameters and echocardiographic markers of atrial function are associated with A4 signal amplitude. High AVS can be predicted by E/A ratio <0.94 and low sinus rate variability at rest.

    Matched MeSH terms: Pacemaker, Artificial*
  3. Steinwender C, Khelae SK, Garweg C, Chan JYS, Ritter P, Johansen JB, et al.
    JACC Clin Electrophysiol, 2020 01;6(1):94-106.
    PMID: 31709982 DOI: 10.1016/j.jacep.2019.10.017
    OBJECTIVES: This study reports on the performance of a leadless ventricular pacemaker with automated, enhanced accelerometer-based algorithms that provide atrioventricular (AV) synchronous pacing.

    BACKGROUND: Despite many advantages, leadless pacemakers are currently only capable of single-chamber ventricular pacing.

    METHODS: The prospective MARVEL 2 (Micra Atrial tRacking using a Ventricular accELerometer 2) study assessed the performance of an automated, enhanced accelerometer-based algorithm downloaded to the Micra leadless pacemaker for up to 5 h in patients with AV block. The primary efficacy objective was to demonstrate the superiority of the algorithm to provide AV synchronous (VDD) pacing versus VVI-50 pacing in patients with sinus rhythm and complete AV block. The primary safety objective was to demonstrate that the algorithm did not result in pauses or heart rates of >100 beats/min.

    RESULTS: Overall, 75 patients from 12 centers were enrolled; an accelerometer-based algorithm was downloaded to their leadless pacemakers. Among the 40 patients with sinus rhythm and complete AV block included in the primary efficacy objective analysis, the proportion of patients with ≥70% AV synchrony at rest was significantly greater with VDD pacing than with VVI pacing (95% vs. 0%; p 

    Matched MeSH terms: Pacemaker, Artificial*
  4. Piccini JP, Stromberg K, Jackson KP, Kowal RC, Duray GZ, El-Chami MF, et al.
    Europace, 2019 Nov 01;21(11):1686-1693.
    PMID: 31681964 DOI: 10.1093/europace/euz230
    AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial.

    METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P 

    Matched MeSH terms: Pacemaker, Artificial*
  5. Siew KSW, Tan MP, Hilmi IN, Loch A
    BMC Cardiovasc Disord, 2019 08 07;19(1):191.
    PMID: 31391000 DOI: 10.1186/s12872-019-1174-4
    BACKGROUND: Swallow or deglutition syncope is an unusual type of neurally-mediated syncope associated with life-threatening bradyarrhythmia and hypotension. It is a difficult condition to diagnose with commonly delayed diagnosis and management. There is lack of review articles that elucidate the basic demographics, clinical characteristics and management of this rare condition. This publication systematically reviews the 101 case reports published since 1793 on swallow syncope.

    CASE PRESENTATION: A 59-year-old man presented with the complaint of recurrent dizziness associated with meals. A 24-h ambulatory ECG recording confirmed an episode of p-wave asystole at the time of food intake. Oesophagogastroduodenoscopy with balloon inflation in the mid to lower oesophagus resulted in a 5.6 s sinus pause. The patient's symptoms resolved completely following insertion of a permanent dual chamber pacemaker.

    CONCLUSIONS: Swallow syncope is extremely rare, but still needs to be considered during diagnostic workup. It is commonly associated with gastro-intestinal disease. Permanent pacemaker implantation is the first line treatment.

    Matched MeSH terms: Pacemaker, Artificial
  6. Wong TS, Abu Bakar J, Chee KH, Hasan MS, Chung WH, Chiu CK, et al.
    Spine (Phila Pa 1976), 2019 02 15;44(4):E252-E257.
    PMID: 30086081 DOI: 10.1097/BRS.0000000000002828
    STUDY DESIGN: Case report.

    OBJECTIVE: To describe the technical difficulties on performing posterior spinal fusion (PSF) on a pacemaker-dependent patient with complete congenital heart block and right thoracic scoliosis.

    SUMMARY OF BACKGROUND DATA: Congenital complete heart block requires pacemaker implantation at birth through thoracotomy, which can result in scoliosis. Corrective surgery in this patient was challenging. Height gain after corrective surgery may potentially cause lead dislodgement. The usage of monopolar electrocautery may interfere with the function of the implanted cardiac device.

    METHODS: A 17-year-old boy was referred to our institution for the treatment of right thoracic scoliosis of 70°. He had underlying complete congenital heart block secondary to maternal systemic lupus erythematosus. Pacemaker was implanted through thoracotomy since birth and later changed for four times. PSF was performed by two attending surgeons with a temporary pacing inserted before the surgery. The monopolar electrocautery device was used throughout the surgery.

    RESULTS: The PSF was successfully performed without any technical issues and complications. Postoperatively, his permanent pacemaker was functioning normally. Three days later, he was recovering well and was discharged home from hospital.

    CONCLUSION: This case indicates that PSF can be performed successfully with thoughtful anticipation of technical difficulties on a pacemaker-dependent patient with underlying congenital heart block.

    LEVEL OF EVIDENCE: 5.

    Matched MeSH terms: Pacemaker, Artificial
  7. Nor Hidayah ZA, Azerin O, Mohd Nazri A
    Med J Malaysia, 2018 10;73(5):323-325.
    PMID: 30350813 MyJurnal
    Acute Rheumatic fever (ARF) is commonly associated with ECG abnormalities particularly atrioventricular block. However, third degree atrioventricular block or complete heart block is a rare manifestation. Most cases occurred in children. We reported a 25 year old man who developed complete heart block during an acute episode of ARF. He presented to hospital with five days history of fever, malaise and migrating arthralgia, followed by pleuritic chest pain. One day after admission his electrocardiogram (ECG) revealed complete heart block. Transthoracic echocardiography showed good left ventricular function with thickened, mild mitral regurgitation with minimal pericardial effusion. ASOT titer was positive with elevated white blood count and acute phase reactant. A temporary pacemaker was inserted in view of symptomatic bradycardia. The complete heart block resolved after medical therapy. He was successfully treated with penicillin, steroid and aspirin. He was discharged well with oral penicillin. The rarity of this presentation is highlighted.
    Matched MeSH terms: Pacemaker, Artificial
  8. Chinitz L, Ritter P, Khelae SK, Iacopino S, Garweg C, Grazia-Bongiorni M, et al.
    Heart Rhythm, 2018 09;15(9):1363-1371.
    PMID: 29758405 DOI: 10.1016/j.hrthm.2018.05.004
    BACKGROUND: Micra is a leadless pacemaker that is implanted in the right ventricle and provides rate response via a 3-axis accelerometer (ACC). Custom software was developed to detect atrial contraction using the ACC enabling atrioventricular (AV) synchronous pacing.

    OBJECTIVE: The purpose of this study was to sense atrial contractions from the Micra ACC signal and provide AV synchronous pacing.

    METHODS: The Micra Accelerometer Sensor Sub-Study (MASS) and MASS2 early feasibility studies showed intracardiac accelerations related to atrial contraction can be measured via ACC in the Micra leadless pacemaker. The Micra Atrial TRacking Using A Ventricular AccELerometer (MARVEL) study was a prospective multicenter study designed to characterize the closed-loop performance of an AV synchronous algorithm downloaded into previously implanted Micra devices. Atrioventricular synchrony (AVS) was measured during 30 minutes of rest and during VVI pacing. AVS was defined as a P wave visible on surface ECG followed by a ventricular event <300 ms.

    RESULTS: A total of 64 patients completed the MARVEL study procedure at 12 centers in 9 countries. Patients were implanted with a Micra for a median of 6.0 months (range 0-41.4). High-degree AV block was present in 33 patients, whereas 31 had predominantly intrinsic conduction during the study. Average AVS during AV algorithm pacing was 87.0% (95% confidence interval 81.8%-90.9%), 80.0% in high-degree block patients and 94.4% in patients with intrinsic conduction. AVS was significantly greater (P

    Matched MeSH terms: Pacemaker, Artificial*
  9. Alkhorayef M, Sulieman A, Babikir E, Daar E, Alnaaimi M, Alduaij M, et al.
    Appl Radiat Isot, 2018 Aug;138:14-17.
    PMID: 28830729 DOI: 10.1016/j.apradiso.2017.08.010
    A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation exposure. Wide range of doses has been reported in previous studies, suggesting that optimization of this procedure has not been fulfilled yet. The current study evaluated patient radiation exposure during cardiac pacemaker procedures and quantified the patient effective dose. A total of 145 procedures were performed for five pacemaker procedures (VVI, VVIR, VVD, VVDR, and DDDR) at two hospitals. Patient doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from the National Radiological Protection Board (NRPB, now The Health Protection Agency). The effective dose values were used to estimate cancer risk from the pacemaker procedure. Patient demographic data and exposure parameters for fluoroscopy and radiography were quantified. The mean patient doses ± SD per procedure (Gycm2) for VVI, VVIR, VVD, VVDR, and DDDR were 1.52 ± 0.13 (1.43-1.61), 3.28 ± 2.34 (0.29-8.73), 3.04 ± 1.67 (1.57-4.86), 6.04 ± 2.326 3.29-8.58), and 8.8 ± 3.6 (4.5-26.20), respectively. The overall patient effective dose was 1.1mSv per procedure. It is obvious that the DDDR procedure exposed patients to the highest radiation dose. Patient dose variation can be attributed to procedure type, exposure parameter settings, and fluoroscopy time. The results of this study showed that patient doses during different pacemaker procedures are lower compared to previous reported values. Patient risk from pacemaker procedure is low, compared to other cardiac interventional procedures. Patients' exposures were mainly influenced by the type of procedures and the clinical indication.
    Matched MeSH terms: Pacemaker, Artificial*
  10. Afzal MR, Daoud EG, Cunnane R, Mulpuru SK, Koay A, Hussain A, et al.
    Heart Rhythm, 2018 06;15(6):841-846.
    PMID: 29427820 DOI: 10.1016/j.hrthm.2018.02.008
    BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.

    OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.

    METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.

    RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.

    CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.

    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  11. Khoo CS
    Perm J, 2018;22:18-081.
    PMID: 30227913 DOI: 10.7812/TPP/18-081
    Matched MeSH terms: Pacemaker, Artificial*
  12. Aminuddin A, Tan I, Butlin M, Avolio AP, Kiat H, Barin E, et al.
    PLoS One, 2018;13(11):e0207301.
    PMID: 30485318 DOI: 10.1371/journal.pone.0207301
    Finger photoplethysmography (PPG) is a noninvasive method that measures blood volume changes in the finger. The PPG fitness index (PPGF) has been proposed as an index of vascular risk and vascular aging. The objectives of the study were to determine the effects of heart rate (HR) on the PPGF and to determine whether PPGF is influenced by blood pressure (BP) changes. Twenty subjects (78±8 years, 3 female) with permanent cardiac pacemakers or cardioverter defibrillators were prospectively recruited. HR was changed by pacing, in a random order from 60 to 100 bpm and in 10 bpm increments. At each paced HR, the PPGF was derived from a finger photoplethysmogram. Cardiac output (CO), stroke volume (SV) and total peripheral resistance (TPR) were derived from the finger arterial pressure waveform. Brachial blood pressure (BP) was measured by the oscillometric method. This study found that as HR was increased from 60 to 100 bpm, brachial diastolic BP, brachial mean BP and CO were significantly increased (p<0.01), whilst the PPGF and SV were significantly decreased (p<0.001). The effects of HR on the PPGF were influenced by BP, with a decreasing HR effect on the PPGF that resulted from a higher BP. In conclusion, HR was a significant confounder for PPGF and it must be taken into account in analyses of PPGF, when there are large changes or differences in the HR. The magnitude of this effect was BP dependent.
    Matched MeSH terms: Pacemaker, Artificial*
  13. Piccini JP, Stromberg K, Jackson KP, Laager V, Duray GZ, El-Chami M, et al.
    Heart Rhythm, 2017 05;14(5):685-691.
    PMID: 28111349 DOI: 10.1016/j.hrthm.2017.01.026
    BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.

    OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds.

    METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.

    RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.

    CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.

    Matched MeSH terms: Pacemaker, Artificial*
  14. Duray GZ, Ritter P, El-Chami M, Narasimhan C, Omar R, Tolosana JM, et al.
    Heart Rhythm, 2017 05;14(5):702-709.
    PMID: 28192207 DOI: 10.1016/j.hrthm.2017.01.035
    BACKGROUND: Early performance of the Micra transcatheter pacemaker from the global clinical trial reported a 99.2% implant success rate, low and stable pacing capture thresholds, and a low (4.0%) rate of major complications up to 6 months.

    OBJECTIVE: The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical performance through 24 months.

    METHODS: The Micra Transcatheter Pacing Study was a prospective single-arm study designed to assess the safety and efficacy of the Micra VVIR leadless/intracardiac pacemaker. Enrolled patients met class I or II guideline recommendations for de novo ventricular pacing. The long-term safety objective was freedom from a system- or procedure-related major complication at 12 months. A predefined historical control group of 2667 patients with transvenous pacemakers was used to compare major complication rates.

    RESULTS: The long-term safety objective was achieved with a freedom from major complication rate of 96.0% at 12 months (95% confidence interval 94.2%-97.2%; P < .0001 vs performance goal). The risk of major complications for patients with Micra (N = 726) was 48% lower than that for patients with transvenous systems through 12 months postimplant (hazard ratio 0.52; 95% confidence interval 0.35-0.77; P = .001). Across subgroups of age, sex, and comorbidities, Micra reduced the risk of major complications compared to transvenous systems. Electrical performance was excellent through 24 months, with a projected battery longevity of 12.1 years.

    CONCLUSION: Long-term performance of the Micra transcatheter pacemaker remains consistent with previously reported data. Few patients experienced major complications through 12 months of follow-up, and all patient subgroups benefited as compared to transvenous pacemaker historical control group.

    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  15. Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, et al.
    Heart Rhythm, 2017 02;14(2):200-205.
    PMID: 27871854 DOI: 10.1016/j.hrthm.2016.11.016
    BACKGROUND: The Micra transcatheter pacemaker was designed to have similar functionality to conventional transvenous VVIR pacing systems. It provides rate adaptive pacing using a programmable 3-axis accelerometer designed to detect patient activity in the presence of cardiac motion.

    OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.

    METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).

    RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).

    CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.

    Matched MeSH terms: Pacemaker, Artificial*
  16. Flaherty G, De Freitas S
    Ir Med J, 2016 Dec 12;109(10):486.
    PMID: 28644591
    Cardiovascular disease is the leading cause of death in adult international travellers. Patients living with heart disease should receive specific, individualised pre-travel health advice. The purpose of this article is to provide evidence-based advice to physicians who are consulted by travellers with cardiovascular disease. Fitness-to-travel evaluation will often be conducted by the general practitioner but other medical specialists may also be consulted for advice. Patients with chronic medical conditions should purchase travel health insurance. The general pre-travel health consultation addresses food and water safety, insect and animal bite avoidance, malaria chemoprophylaxis, and travel vaccinations. Patients with devices such as cardiac pacemakers should be familiar with how these may be affected by travel. Cardiac medications may cause adverse effects in cold or hot environments, and specific precautions must be followed by anticoagulated travellers. The physician should be aware of how to access medical care abroad, and of the potential for imported tropical diseases in returned travellers.
    Matched MeSH terms: Pacemaker, Artificial
  17. Ota N, Suzuki R, Latiff HA, Sivalingam S
    Ann Thorac Surg, 2015 Oct;100(4):1471.
    PMID: 26434454 DOI: 10.1016/j.athoracsur.2015.06.084
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  18. Ritter P, Duray GZ, Steinwender C, Soejima K, Omar R, Mont L, et al.
    Eur Heart J, 2015 Oct 1;36(37):2510-9.
    PMID: 26045305 DOI: 10.1093/eurheartj/ehv214
    Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker.
    Matched MeSH terms: Pacemaker, Artificial
  19. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  20. Yew KL
    Heart Views, 2014 Apr;15(2):49-50.
    PMID: 25104983 DOI: 10.4103/1995-705X.137497
    Electrical or electrocution injury is a common accidental occurrence and mostly workplace related. Fatal arrhythmias, skin injury and sudden death may ensue. However, it is rare for electrocution to result in permanent low rate sinus bradycardia, incompatible with an active lifestyle. The probable mechanisms for this pathological sinus bradycardia are sinus node dysfunction and autonomic dysfunction with vagal predominance. We describe a young patient who suffered a non fatal electrocution with resultant low rate sinus bradycardia and its successful treatment with a dual chamber rate responsive pacemaker.
    Matched MeSH terms: Pacemaker, Artificial