Displaying publications 1 - 20 of 67 in total

Abstract:
Sort:
  1. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Zainol Rashid Z, Othman SN, Abdul Samat MN, Ali UK, Wong KK
    Malays J Pathol, 2020 Apr;42(1):13-21.
    PMID: 32342927
    INTRODUCTION: The World Health Organization (WHO) declared COVID-19 outbreak as a world pandemic on 12th March 2020. Diagnosis of suspected cases is confirmed by nucleic acid assays with real-time PCR, using respiratory samples. Serology tests are comparatively easier to perform, but their utility may be limited by the performance and the fact that antibodies appear later during the disease course. We aimed to describe the performance data on serological assays for COVID-19.

    MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.

    RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.

    CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.

    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  3. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Reagent Kits, Diagnostic
  4. Yoo SJ, Wang LL, Ning HC, Tao CM, Hirankarn N, Kuakarn S, et al.
    J Clin Virol, 2015 Mar;64:20-7.
    PMID: 25728074 DOI: 10.1016/j.jcv.2014.12.015
    Early diagnosis of hepatitis C virus (HCV) infection is essential to allow appropriate treatment and prevent transmission.
    Matched MeSH terms: Reagent Kits, Diagnostic
  5. Yatabe Y, Kerr KM, Utomo A, Rajadurai P, Tran VK, Du X, et al.
    J Thorac Oncol, 2015 Mar;10(3):438-45.
    PMID: 25376513 DOI: 10.1097/JTO.0000000000000422
    The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non-small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods.
    Matched MeSH terms: Reagent Kits, Diagnostic
  6. Wu LL, Sazali BS, Adeeb N, Khalid BA
    Singapore Med J, 1999 Jan;40(1):23-6.
    PMID: 10361481
    Clinical diagnosis of congenital hypothyroidism (CH) is difficult at birth without neonatal screening. In line with the priorities of the national health services in Malaysia towards preventive medicine, early diagnosis and treatment of CH is emphasised. We conducted a pilot study at Kuala Lumpur's Maternity Hospital between April 1995 and November 1995 to estimate the incidence of CH and also evaluated the problems associated with large-scale neonatal screening using a commercial TSH kit on cord bloodspots.
    Matched MeSH terms: Reagent Kits, Diagnostic
  7. Wang SM, Sekaran SD
    Am J Trop Med Hyg, 2010 Sep;83(3):690-5.
    PMID: 20810840 DOI: 10.4269/ajtmh.2010.10-0117
    A commercial Dengue Duo rapid test kit was evaluated for early dengue diagnosis by detection of dengue virus NS1 antigen and immunoglobulin M (IgM)/IgG antibodies. A total of 420 patient serum samples were subjected to real-time reverse transcription-polymerase chain reaction (RT-PCR), in-house IgM capture enzyme-linked immunosorbent assay (ELISA), hemagglutination inhibition assay, and the SD Dengue Duo rapid test. Of the 320 dengue acute and convalescent sera, dengue infection was detected by either serology or RT-PCR in 300 samples (93.75%), as compared with 289 samples (90.31%) in the combined SD Duo NS1/IgM. The NS1 detection rate is inversely proportional, whereas the IgM detection rate is directly proportional to the presence of IgG antibodies. The sensitivity and specificity in diagnosing acute dengue infection in the SD Duo NS1/IgM were 88.65% and 98.75%, respectively. The assay is sensitive and highly specific. Detection of both NS1 and IgM by SD Duo gave comparable detection rate by either serology or RT-PCR.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  8. Wan Nazaimoon WM, Satgunasingam N, Khalid B
    Malays J Pathol, 1990 Jun;12(1):13-20.
    PMID: 2090885
    A simple and sensitive double-antibody radioimmunoassay for human growth hormone (HGH) was developed, optimised and validated. The anti-hGH sera raised in 2 rabbits were highly specific with low cross-reactions of 0.19% and 0.3% with human placental lactogen and 0.21% and 0.13% with human prolactin. The mean sensitivity of the assay determined from 28 assays was found to be 0.4 +/- 0.2 mIU/L. Mean recovery of added exogenous hGH was 98.8 +/- 6.8%. Linearity studies of samples diluted at 1:2, 1:4 and 1:8 gave values of 101.3 +/- 5.3%, 109.6 +/- 13.4% and 97.3 +/- 13% respectively of those expected. The reproducibility of the assay was good; within assay coefficient of variation for serum samples with GH concentrations of 2.7, 13.6 and 28.2 mU/l ranged from 5.1 to 8.3% while the inter-assay precision varied from 4.9 to 10.3%. The in-house assay showed good correlation (r = 0.96, p less than 0.001) with a commercial HGH RIA kit (Dainabot, Japan). A reference normal adult fasting GH level of less than 7 mIU/l was established from 95 samples assayed by this method.
    Matched MeSH terms: Reagent Kits, Diagnostic
  9. Uyub AM, Anuar AK, Aiyar S
    PMID: 7855648
    Two commercial serological kits, Pylori-set (Orion Diagnostica, Finland) and Helico-G (Cambridge Biomedical Ltd, UK), and an in-house ELISA were evaluated with sera from 24 Helicobacter pylori-positive and 146 H. pylori-negative dyspeptic patients. Sensitivity, specificity, positive and negative predictive values of Pylori-set were lower than that of Helico-G and in-house ELISA. Helico-G was more sensitive (91.7%) than in-house ELISA (83.3%) and both had comparable negative predictive values of 98.3% and 97.3%, respectively. However, specificity (97.9%) and positive predictive value (86.9%) of an in-house ELISA were much higher than specificity (80.1%) and positive predictive value (43.1%) of Helico-G. Kappa index of agreement between the three serological tests (Pylori-set, Helico-G or in-house ELISA) and the presence of H. pylori in antral biopsies was very low (k = 0.13; z = 1.9; p > 0.05), moderate (k = 0.49; z = 7.1; p < 0.0001), or substantial (k = 0.82; z = 10.8; p < 0.0001), respectively. Overall, statistical evaluations demonstrated that both commercial kits were not as reliable as the in-house ELISA for serodiagnosing H. pylori infection.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  10. Thevarajah MT, Nadarajah S, Chew YY, Chan PC
    Singapore Med J, 2008 Jun;49(6):454-7.
    PMID: 18581016
    We report the results of a laboratory evaluation of the BioRad Urinary Metanephrines Reagent Kit. The test was designed for the quantitative measurement of normetanephrine and metanephrine in urine by high performance liquid chromatography. The kit was evaluated in view of improving assay reliability and specificity as compared to the manual method based on cation exchange chromatography and spectrophotometry.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  11. Tan GW, Khoo AS, Tan LP
    Sci Rep, 2015;5:9430.
    PMID: 25800946 DOI: 10.1038/srep09430
    MicroRNAs regulate gene expression at the post-transcriptional level. Differential expression of miRNAs can potentially be used as biomarkers for early diagnosis and prediction for outcomes. Failure in validation of miRNA profiles is often caused by variations in experimental parameters. In this study, the performance of five extraction kits and three RT-qPCR systems were evaluated using BioMark high-throughput platform and the effects of different experimental parameters on circulating miRNA levels were determined. Differences in the performance of extraction kits as well as varying accuracy, sensitivity and reproducibility in qPCR systems were observed. Normalisation of RT-qPCR data to spike-in controls can reduce extraction bias. However, the extent of correlation for different qPCR systems varies in different assays. At different time points, there was no significant fold change in eight of the plasma miRNAs that we evaluated. Higher level of miRNAs was detected in plasma as compared to serum of the same cohort. In summary, we demonstrated that high-throughput RT-qPCR with pre-amplification step had increased sensitivity and can be achieved with accuracy and high reproducibility through stringent experimental controls. The information provided here is useful for planning biomarker validation studies involving circulating miRNAs.
    Matched MeSH terms: Reagent Kits, Diagnostic
  12. Situ SF, Ding CH, Nawi S, Johar A, Ramli R
    Malays J Pathol, 2017 Apr;39(1):25-31.
    PMID: 28413202 MyJurnal
    BACKGROUND: Chlamydia trachomatis and Neisseria gonorrhoeae are important bacterial pathogens of sexually transmitted infections (STIs) worldwide. This study sought to compare the analytical sensitivity and specificity of conventional methods against a rapid molecular method in detecting STIs caused by these bacteria.

    METHODS: Ninety five first-time male attendees of the Genito-urinary Medicine Clinic in Hospital Kuala Lumpur were included in this cross-sectional study. The detection of C. trachomatis was achieved through direct fluorescence antibody (DFA) staining of urethral swabs and real-time polymerase chain reaction testing (Xpert® CT/NG assay) on urine specimens. N. gonorrhoeae was detected through Gram staining and culture of urethral swabs and Xpert® CT/ NG assay on urine specimens.

    RESULTS: From the Xpert® CT/NG results, 11 (11.6%) attendees had chlamydia, 23 (24.2%) had gonorrhoea and 8 (8.4%) had both STIs. The sensitivity and specificity of DFA in detecting chlamydia compared to Xpert® CT/NG were 5.3% (95% CI: 0-28) and 94.7% (95% CI: 86-98), respectively. For gonorrhoea, the sensitivity and specificity of Gram staining were 90.3% (95% CI: 73-98) and 95.3% (86-99), respectively, whereas the sensitivity and specificity of culture compared to Xpert® CT/NG were 32.2% (95% CI: 17-51) and 100% (95% CI: 93-100), respectively.

    CONCLUSION: Although Gram-stained urethral swab smears are sensitive enough to be retained as a screening tool for gonorrhoea, culture as well as DFA lack sensitivity and are poorly suited to screen for gonorrhoea and chlamydia, respectively. However, owing to their high specificity, conventional detection methods are still suitable as confirmatory tests for gonorrhoea and chlamydia.

    Matched MeSH terms: Reagent Kits, Diagnostic
  13. Sekhar WY, Soo EH, Gopalakrishnan V, Devi S
    Singapore Med J, 2000 Aug;41(8):370-5.
    PMID: 11256343
    The aim of the study was to look into the epidemiology of serodiagnosed cases of leptospirosis at the University Hospital and compare two commercial ELISA Assays to the Microscopic Agglutination Test (MAT). Demographic data for all serodiagnosed cases for the years 1991-1997 were collected. From this data, 104 sera (n = 104) were selected as samples for comparative evaluation of the commercial ELISAs (INDX Dip-S-Ticks and PanBio ELISA) to the MAT test. Thirty two (n = 32) negative control sera were selected from serodiagnosed cases of other differential diagnosis of leptospira infection. The MAT test is a standard test that detects agglutination antibodies to leptospira biflexa, while the INDX Dip-S-Ticks is an ELISA dot test assaying for total anti-leptospira antibodies. The PanBio ELISA is a colorometric assay in test well strips to detect anti-leptospira IgM. The sensitivity, specificity, and efficiency of tests were calculated at a MAT cut-off value of 1:320. Demographic data showed that leptospirosis peaks during March-May and Aug-Nov coinciding with the inter-monsoon period with more men being infected than women and more adults than children. The sensitivity, specificity, and efficiency of test for the INDX Dip-S-Ticks were 83.3%, 93.8% and 87.5% while the values for the PanBio ELISA were 54.2%, 96.9% and 71.3%. The suboptimal PanBio result could be related to the blocking effect of high IgG titres or could be related to the diagnostic MAT cut-off values used in this study. The data hence reflects a pattern of transmission that is related to "wet" occupational risk factors. The commercial assays evaluated, are easier to perform but interpretation of results should be based on level of endemicity. The INDX Dip-S-Ticks allows this flexibility and is a practical alternative to the MAT test.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  14. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Reagent Kits, Diagnostic
  15. Rajan S, Shen TH, Santhanam J, Othman NH, Othman N, Hock TT
    Trop Biomed, 2007 Jun;24(1):17-22.
    PMID: 17568373
    Human papillomavirus (HPV) is well known as an etiological factor for the development of anogenital carcinomas. The aim of our study was to compare the performance of USFDA approved Hybrid II (HCII) Assay and recently introduced DR. HPV Chip Kit for the detection of HPV DNA in clinical cervical scrapings from 40 patients. HPV DNA testing was performed using the automated HCII Assay system and DR. HPV Chip Kit. Taking cytological results as gold standard, it was found that HCII was more sensitive (36.4%) than DR. HPV Chip Kit (18.2%) although specificity was 100% with the latter method. In addition, both these molecular methods had comparable negative and positive predictive values. It was concluded that both HCII and DR. HPV Chip Kit have comparable specificity. However, sensitivity for detection of HPV in clinical samples with HCII is almost double as compared to DR. HPV Chip Kit.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  16. Rahmah N, Taniawati S, Shenoy RK, Lim BH, Kumaraswami V, Anuar AK, et al.
    Trans R Soc Trop Med Hyg, 2002 1 31;95(6):601-4.
    PMID: 11816429
    A total of 753 serum samples from 6 institutions in 3 countries (Malaysia, Indonesia and India) were used to evaluate an immunochromatographic rapid dipstick test, Brugia Rapid, for diagnosis of Brugia malayi infection. The samples comprised sera from 207 microfilaria-positive individuals and 546 individuals from filaria non-endemic areas. The latter consisted of 70 individuals with soil-transmitted helminth infections, 68 with other helminth infections, 238 with protozoan infections, 12 with bacterial and viral infections and 158 healthy individuals. The dipstick is prepared with a goat anti-mouse antibody control line and a B. malayi recombinant-antigen test line. First, the dipstick is dipped into a well containing diluted patient serum, thus allowing specific anti-filarial antibody in the serum to react with the recombinant antigen. Then the dipstick is placed into an adjacent well containing reconstituted anti-human IgG4-gold. After 10 min, development of 2 red-purplish lines denotes a positive result and one line indicates a negative reaction. The overall results of the evaluation showed 97% sensitivity, 99% specificity, 97% positive predictive value and 99% negative predictive value. Brugia Rapid is thus a promising diagnostic tool for detection of B. malayi infection, and would be especially useful for the brugian filariasis elimination programme.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  17. Rahmah N, Shenoy RK, Nutman TB, Weiss N, Gilmour K, Maizels RM, et al.
    Trop Med Int Health, 2003 Oct;8(10):895-900.
    PMID: 14516300
    A multicentre evaluation of the Brugia Rapid dipstick test was performed using 1263 serum samples in four international laboratories, i.e. T.D. Medical College (TDMC, India), National Institutes of Health (NIH, USA), Swiss Tropical Institute (STI, Switzerland) and Leiden University Medical Centre (LUMC, Netherlands). In comparison with microscopy, the dipstick demonstrated sensitivities of 97.2% (70 of 72) at TDMC, 91.6% (175 of 191) at LUMC and 100% (six of six) at STI. Sera of chronic patients showed a positivity rate of 11.3% (19 of 168) and 61.2% (71of 116) at TDMC and LUMC, respectively. All 266 sera of non-endemic normals from STI, NIH and LUMC tested negative with the dipstick. At LUMC, sera of 'endemic normals' (amicrofilaraemics with no clinical disease) from an area with approximately 35% microfilaria positivity showed 60.8% positive results (31 of 51), thus demonstrating the likelihood of many cryptic infections occurring in this population. Specificities of the test with Onchocerca volvulus sera were 98.8% (80 of 81) and 100% (10 of 10) at the NIH and STI, respectively; while specificity with Loa loa sera at the NIH was 84.6% (44 of 52). At the STI, the dipstick test also demonstrated 100% specificity when tested with 75 sera from various protozoan and helminthic infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  18. Rafiza S, Rampal KG
    Int J Tuberc Lung Dis, 2012 Feb;16(2):163-8.
    PMID: 22236915 DOI: 10.5588/ijtld.11.0364
    BACKGROUND: Serial testing for tuberculosis (TB) exposure has been advocated among health care workers (HCWs) at risk of nosocomial infection.
    OBJECTIVE: To determine the incidence and factors associated with TB infection among selected HCWs in Malaysia and to determine interferon-gamma response in serial testing.
    DESIGN: A cohort of 769 HCWs were retested after 1 year using QuantiFERON®-TB Gold In-Tube. Incidence of TB infection was determined among HCWs who previously tested negative. Conversion and reversion rates using several definitions were explored.
    RESULTS: Incidence of TB infection was 9.9 per 100 workers per year (95%CI 7.9-12.3). Working in the Emergency Department (ED; RR 2.18, 95%CI 1.07-4.43) was significantly associated with risk of TB infection. Reversion and conversion occurred frequently, with 46.7% reversion among HCWs with baseline interferon-gamma (IFN-γ) levels of 0.35-0.70 international units (IU)/ml, and 23.8% conversion among HCWs with baseline IFN-γ levels of 0.20-0.34 IU/ml.
    CONCLUSIONS: TB infection control measures need to be strengthened, particularly in the ED, as the incidence of TB was high. Conversion and reversion rates in serial testing were high, and further studies are needed to facilitate its interpretation.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  19. Qin X, Rui J, Xia Y, Mu H, Song SH, Raja Aziddin RE, et al.
    Ann Lab Med, 2018 Mar;38(2):85-94.
    PMID: 29214751 DOI: 10.3343/alm.2018.38.2.85
    BACKGROUND: The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoassays. The objective of this study was to assess the analytical performance of Roche Elecsystacrolimus and cyclosporinee electrochemiluminescence immunoassays (ECLIAs).

    METHODS: This evaluation was performed in seven centers across China, South Korea, and Malaysia. Imprecision (repeatability and reproducibility), assay accuracy, and lot-to-lot reagent variability were tested. The Elecsys ECLIAs were compared with commercially available immunoassays (Architect, Dimension, and Viva-E systems) using whole blood samples from patients with various transplant types (kidney, liver, heart, and bone marrow).

    RESULTS: Coefficients of variation for repeatability and reproducibility were ≤5.4% and ≤12.4%, respectively, for the tacrolimus ECLIA, and ≤5.1% and ≤7.3%, respectively, for the cyclosporine ECLIA. Method comparisons of the tacrolimus ECLIA with Architect, Dimension, and Viva-E systems yielded slope values of 1.01, 1.14, and 0.897, respectively. The cyclosporine ECLIA showed even closer agreements with the Architect, Dimension, and Viva-E systems (slope values of 1.04, 1.04, and 1.09, respectively). No major differences were observed among the different transplant types.

    CONCLUSIONS: The tacrolimus and cyclosporine ECLIAs demonstrated excellent precision and close agreement with other immunoassays tested. These results show that both assays are suitable for ISD monitoring in an APAC population across a range of different transplant types.

    Matched MeSH terms: Reagent Kits, Diagnostic