Displaying publications 1 - 20 of 148 in total

Abstract:
Sort:
  1. Zulkifli MZ, Ho CC, Goh EH, Praveen S, Das S
    Clin Ter, 2012;163(1):23-5.
    PMID: 22362229
    Incidence of urolithiasis is on the rise due to climatic changes especially global warming.The pain due to presence of ureteric stone is a well known identity but many times it may be asymptomatic or even masked by concurrent presence of backache. In the present article, we describe the case of a 43-year-old male who came to the clinic for treatment of backache persisting for more than two years. The patient complained of backache two years back for which he was treated with analgesics and physiotherapy which relieved his pain. No X-ray was taken earlier because the attending clinician thought the backache to be musculo-skeletal in origin. Recently, one day a sudden episode of backache in the midst of night compelled him to seek medical treatment. However, this time a X-ray was performed and it showed the presence of calculi in the right upper pelvis of ureter which measured 1.9 cm vertically. An ultrasound confirmed the diagnosis. The patient was treated with two episodes of shock wave therapy which failed to crush the stone. A Double-J stent was inserted under general anaesthesia. The stone was crushed using a ureteroscope guided laser. The present case report describes how backache in professionals cannot be lightly attended. Even the characteristic groin to loin pain may be absent. All cases of backache should be properly investigated with an X-ray to rule out renal or ureteric calculi.
    Matched MeSH terms: Stents
  2. Zul Khairul Azwadi I, Norhayati MN, Abdullah MS
    Sci Rep, 2021 Mar 23;11(1):6613.
    PMID: 33758312 DOI: 10.1038/s41598-021-86136-y
    Acute obstructive uropathy is associated with significant morbidity among patients with any condition that leads to urinary tract obstruction. Immediate urinary diversion is necessary to prevent further damage to the kidneys. In many centres, the two main treatment options include percutaneous nephrostomy (PCN) and retrograde ureteral stenting (RUS). The purpose of this study if to compare the efficacy and safety of PCN and RUS for the treatment of acute obstructive uropathy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, CINAHL, EMBASE, the World Health Organisation International Clinical Trials Registry Platform and ClinicalTrials.gov. We also searched the reference lists of included studies to identify any additional trials. We included randomised controlled trials and controlled clinical trials comparing the outcomes of clinical improvement (septic parameters), hospitalisation duration, quality of life, urinary-related symptoms, failure rates, post-procedural pain [measured using a visual analogue scale (VAS)] and analgesics use. We conducted statistical analyses using random effects models and expressed the results as risk ratio (RR) and risk difference (RD) for dichotomous outcomes and mean difference (MD) for continuous outcomes, with 95% confidence intervals (CIs). Seven trials were identified that included 667 patients. Meta-analysis of the data revealed no difference in the two methods in improvement of septic parameters, quality of life, failure rates, post-procedural pain (VAS), or analgesics use. Patients receiving PCN had lower rates of haematuria and dysuria post-operatively and longer hospitalisation duration than those receiving RUS. PCN and RUS are effective for the decompression of an obstructed urinary system, with no significant difference in most outcomes. However, PCN is preferable to RUS because of its reduced impact on the patient's post-operative quality of life due to haematuria and dysuria, although it is associated with slightly longer hospitalisation duration.
    Matched MeSH terms: Stents*
  3. Yuhanif Yusof, Anisah Che Ngah, Zaki Morad Mohamad Zaher
    Int J Public Health Res, 2014;4(1):384-390.
    MyJurnal
    Introduction The aim of this study was to examine the aspect of information disclosure by doctor-investigator during the process of obtaining informed consent in clinical trials.
    Methods This research employed a mixed-method data collection that is library research and interview. A qualitative methodology and analysis were used in an open-ended, face-to-face interviews with 17 patient-subjects. The interview questions were based on information that needed to be disclosed to patient-subjects during the process of obtaining informed consent. Each interview took place in Kajang Hospital and National Heart Institute and lasted 25-30 minutes. Interviews were conducted in Bahasa Melayu and English. The interviews were tape-recorded, and the main points from the interviews were jotted down to ensure that all information was adequately gathered. Interviewed occurred in Kajang Hospital and National Heart Institute. The participants were patients who had been referred to the Kajang Hospital and National Heart Institute. They were recruited (8 from Kajang Hospital and 9 from National Heart Institute) by their own doctors to participate in a study to evaluate the safety and effectiveness of the investigational stent after been diagnosed with coronary artery disease and also in a study to investigate drug for antidepressant. respectively.
    Results The study revealed that doctor-investigators fail to disclose full information to patient-subjects. Instead, doctor-investigators only disclosed information which they thought were necessary for the patient-subjects to know. The study also showed that there were doctor-investigators who did not disclose information at all to the patient-subjects.
    Conclusions This study implies that the aspect of information disclosure in the process of obtaining informed consent in clinical trials is rather poor and did not fulfill the criterion of good medical practice. A random monitoring task to be conducted by the research ethics commitees during the informed consent process is suggested.
    Matched MeSH terms: Stents
  4. Yoon C, Nam KC, Lee YK, Kang Y, Choi SJ, Shin HM, et al.
    J Korean Med Sci, 2019 Oct 14;34(39):e255.
    PMID: 31602825 DOI: 10.3346/jkms.2019.34.e255
    BACKGROUND: Medical device adverse event reporting is an essential activity for mitigating device-related risks. Reporting of adverse events can be done by anyone like healthcare workers, patients, and others. However, for an individual to determine the reporting, he or she should recognize the current situation as an adverse event. The objective of this report is to share observed individual differences in the perception of a medical device adverse event, which may affect the judgment and the reporting of adverse events.

    METHODS: We trained twenty-three participants from twelve Asia-Pacific Economic Cooperation (APEC) member economies about international guidelines for medical device vigilance. We developed and used six virtual cases and six questions. We divided participants into six groups and compared their opinions. We also surveyed the country's opinion to investigate the beginning point of 'patient use'. The phases of 'patient use' are divided into: 1) inspecting, 2) preparing, and 3) applying medical device.

    RESULTS: As for the question on the beginning point of 'patient use,' 28.6%, 35.7%, and 35.7% of participants provided answers regarding the first, second, and third phases, respectively. In training for applying international guidelines to virtual cases, only one of the six questions reached a consensus between the two groups in all six virtual cases. For the other five questions, different judgments were given in at least two groups.

    CONCLUSION: From training courses using virtual cases, we found that there was no consensus on 'patient use' point of view of medical devices. There was a significant difference in applying definitions of adverse events written in guidelines regarding the medical device associated incidents. Our results point out that international harmonization effort is needed not only to harmonize differences in regulations between countries but also to overcome diversity in perspectives existing at the site of medical device use.

    Matched MeSH terms: Stents/adverse effects
  5. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Stents
  6. Yew KL
    Med J Malaysia, 2012 Jun;67(3):351.
    PMID: 23082437
    Matched MeSH terms: Drug-Eluting Stents/adverse effects*
  7. Yap PY, Hwang JS, Bong JJ
    Asian J Surg, 2017 Mar 10.
    PMID: 28286020 DOI: 10.1016/j.asjsur.2017.01.003
    BACKGROUND/OBJECTIVE: Postoperative pancreatic fistula (POPF) remains an important cause of morbidity and mortality after pancreaticoduodenectomy. Pancreaticogastrostomy (PG) as a reconstruction method after pancreaticoduodenectomy is a safe and optional surgical technique in decreasing the risk of POPF. In this study, a retrospective analysis was carried out to evaluate a new modification of PG technique that uses a two-layer anastomoses with an internal stent.

    METHODS: Forty-seven patients underwent this newly modified PG technique between February 2012 and August 2016. Demographics, histopathological findings, type of surgery performed, perioperative parameters, postoperative length of stay, postoperative complications and interventional procedures, follow-up, and mortality data were collected and analyzed. Clavien-Dindo classification was used to grade the complications' severity.

    RESULTS: Postoperative mortality was 4.25%, unrelated to POPF, and postoperative morbidity was 44.68%. Thirteen patients had severe (>Grade IIIa) complications, according to Clavien-Dindo classification. As classified in accordance to the International Study Group of Pancreatic Fistula, 24 (51.06%) patients developed Grade A POPF, and no occurrence of Grade B/C POPF was noted. All patients recovered uneventfully with successful treatment interventions.

    CONCLUSION: The reported PG anastomotic technique is a safe and dependable reconstruction procedure with acceptable morbidity and mortality.

    Matched MeSH terms: Stents
  8. Yap LB, Choy CN, Koh KW, Kannan P, Jeyamalar R, Navin S, et al.
    Med J Malaysia, 2023 Mar;78(2):139-144.
    PMID: 36988521
    INTRODUCTION: Intravascular ultrasound (IVUS) is recommended in the use of left main stem (LMS) percutaneous coronary intervention (PCI). Since the LMS diameter is usually larger than other coronary arteries, a new generation everolimus drug-eluting stent (DES), Synergy Megatron DES (Boston Scientific) has better axial and radial strength allowing more post implant overexpansion and consequently better suited for LMS lesions. We performed a study to evaluate the clinical outcomes of PCI using 1) an improved IVUS protocol with optimisation targets and 2) the use of Megatron stents.

    MATERIALS AND METHODS: This was a study involving LMS PCI coronary lesions using the Synergy Megatron DES. An IVUS protocol using predefined optimisation targets to evaluate for stent malapposition, longitudinal stent deformation, optimal stent expansion >90% of reference lumen and appropriate distal landing zone was used in all cases. The primary end-point was procedural success, defined by successful stent implantation with <30% residual stenosis. The secondary end-point was in-hospital and 30-day major adverse cardiovascular event (MACE).

    RESULTS: Eight patients with significant LMS stenosis were successfully treated with the Megatron stent. The primary end-point was achieved in all patients. There were no cases of stent malapposition or longitudinal stent deformation, one case did not have optimal LMS stent expansion and one case did not have an appropriate distal landing zone. IVUS optimisation criteria were met in 6 (75%) cases. There were no complications of coronary dissection, slow or no reflow, stent thrombosis or vessel perforation. None of the patients suffered in-hospital or 30-day MACE. The average LMS MLD at baseline was 2.1 ± 0.1mm and the post-PCI LMS MLD was 4.0 ± 0.5mm, with a significant acute luminal gain of 1.9 ± 0.7mm (p<0.01). A post-PCI MSA of 17 ± 3.9 mm2 was numerically superior compared to those documented in other LMS PCI trials.

    CONCLUSION: This study demonstrates low rates of shortterm major adverse cardiovascular events among patients with LMS PCI using the Megatron stents. It highlights the usefulness of IVUS-guided optimisation in LMS PCI. With the use of intravascular imaging, the new generation stent technology can improve the treatment of large proximal vessels and PCI of LMS lesions.

    Matched MeSH terms: Drug-Eluting Stents*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links