METHODS: In this review, we first discussed the anatomy, physiology and pathophysiology of tendon and ligament injuries and its current treatment. Secondly, we explored the current role of tendon and ligament tissue engineering, describing its recent advances. After that, we also described stem cell and cell secreted product approaches in tendon and ligament injuries. Lastly, we examined the role of the bioreactor and mechanical loading in in vitro maturation of engineered tendon and ligament.
RESULTS: Tissue engineering offers various alternative ways of treatment from biological tissue constructs to stem cell therapy and cell secreted products. Bioreactor with mechanical stimulation is instrumental in preparing mature engineered tendon and ligament substitutes in vitro.
CONCLUSIONS: Tissue engineering showed great promise in replacing the damaged tendon and ligament. However, more study is needed to develop ideal engineered tendon and ligament.
METHODS: An analytical cross sectional study design was used and a self-administered proforma was distributed for data collection. 1239 Malay secondary school children in Putrajaya were tested for absence of Palmaris Longus using Schaffer's test. 4 additional tests namely Thompson's test, Mishra's test I, Mishra's test II and Pushpakumar's 'two-finger sign' method were used to confirm its absence in respondents with negative Schaffer's test. Function of Flexor Digitorum Superficialis tendon to little finger was determined by flexing PIP of little finger while hyperextend the other fingers.
RESULTS: The prevalence of absence of Palmaris Longus was 11.7%. Left side absence of Palmaris Longus was much common. There was a significant association between absence of Palmaris Longus with gender in which female had higher prevalence of absence of Palmaris Longus than male.
CONCLUSIONS: In conclusion, the prevalence of absence of Palmaris Longus in Malay population was lower than Indian but higher than Chinese population. Females had higher prevalence of absence of Palmaris Longus and no association can be found with hand dominance and absence of Flexor Digitorum Superficialis tendon to little finger.
METHODS: Upper limb tendons were harvested with consent from patients with crush injuries and non-replantable amputations. These tendons (both extensor and flexor) measuring 1 cm are sutured to either side of a 0.5 cm synthetic tendon strip and cultured in growth medium. At 2, 4, 6 and 8 weeks, samples were fixed into paraffin blocks, cut and stained with haematoxylin-eosin (H&E) and Masson's trichrome.
RESULTS: Minimal tendon ingrowth were seen in the first 2 weeks of incubation. However at 4 weeks, the cell ingrowth were seen migrating towards the junction between the tendon and the synthetic scaffold. This ingrowth continued to expand at 6 weeks and up to 8 weeks. At this point, the demarcation between human tendon and synthetic scaffold was indistinct.
CONCLUSIONS: We conclude that tendon ingrowth composed of collagen matrix were able to proliferate into a synthetic scaffold in vitro.
METHODS: This study was conducted between the years 2014 to 2016 at the Tissue Engineering Centre, UKM Medical Centre. OTC-I was extracted from ovine tendon, and fabricated into 3D scaffolds in the form of sponge, hydrogel and film. A polystyrene surface coated with OTC-I was used as the 2D culture condition. Genipin was used to crosslink the OTC-I. A non-coated polystyrene surface was used as a control. The mechanical strength of OTC-I scaffolds was evaluated. Attachment, proliferation and morphological features of HDF were assessed and compared between conditions.
RESULTS: The mechanical strength of OTC-I sponge was significantly higher than that of the other scaffolds. OTC-I scaffolds and the coated surface significantly enhanced HDF attachment and proliferation compared to the control, but no differences were observed between the scaffolds and coated surface. In contrast, the morphological features of HDF including spreading, filopodia, lamellipodia and actin cytoskeletal formation differed between conditions.
CONCLUSION: OTC-I can be moulded into various scaffolds that are biocompatible and thus could be suitable as scaffolds for developing tissue substitutes for clinical applications and in vitro tissue models. However, further study is required to determine the effect of morphological properties on the functional and molecular properties of HDF.
Method: Twenty-seven patients were included in this study conducted from 1st January to 31st December 2013. All patients were skeletally mature and scheduled to undergo primary anterior cruciate ligament reconstruction using 4S-STG autograft. Ultrasonographic examination of semitendinosus and gracilis tendons to measure the cross sectional area was conducted and anthropometric data (weight, height, leg length and thigh circumference) was measured one day prior to surgery. True autograft diameters were measured intraoperatively using closed-hole sizing block in 0.5 mm incremental size.
Results: There is a statistically significant correlation between the measured combined cross sectional area (semitendinosus and gracilis tendons) and 4S-STG autograft diameter (p = 0.023). An adequate autograft size (at least 7 mm) can be obtained when the combined cross sectional area is at least 15 mm2. There was no correlation with the anthropometric data except for thigh circumference (p = 0.037). Autograft size of at least 7 mm can be obtained when the thigh circumference is at least 41 mm.
Conclusions: Both combined cross sectional area (semitendinosus and gracilis tendons) and thigh circumference can be used to predict an adequate 4S-STG autograft size.
METHODS: Twenty-four studies met the inclusion criteria including 1761 cadaveric limbs.
RESULTS: The results were as following: (a) the mean palmaris longus tendon length was of 13.9 ± 2.6 cm, (b) the mean ratio palmaris longus tendon length/forearm length was of 0.545 ± 0.06, (c) the weighted correlation value was of 0.686, and (d) the mean palmaris longus tendon width was of 4.0 ± 1.7 mm. Only five studies reported a palmaris longus tendon length of more than 15 cm. The palmaris longus tendon length was shown to vary between ancestries; the Japanese had the shortest while Malaysian the longest palmaris longus tendons. All studies but one reported a palmaris longus tendon mean width of more than 3 mm where the minimal mean palmaris longus tendon width was of 2.5 mm.
CONCLUSION: While the requested length depends on the recipient site and/or type of reconstructive surgery, the palmaris longus tendon often met the required diameter for grafting. Our review demonstrated that while palmaris longus length varies between ancestries, its width is often adequate for grafting. In addition, the forearm length could be a good predictor of palmaris longus tendon length; such correlation could assist surgeons when planning to use palmaris longus tendon as a graft source.
METHODS: The present study consisted of 50 lower limbs from formalin-fixed male adult cadavers aged about 70 years (45-85) belonging to the South Indian population. Total length of the quadriceps tendon, patellar height, patellar ligament height, proximal width, distal width and thickness of the patellar ligament were measured meticulously. Mean, standard deviation, median scores of each parameter were computed for groups using SPSS 16.0. Level of significance was considered as p