Displaying all 8 publications

Abstract:
Sort:
  1. Razuin R, Effat O, Shahidan MN, Shama DV, Miswan MF
    Malays J Pathol, 2013 Jun;35(1):87-90.
    PMID: 23817399 MyJurnal
    Bone cement implantation syndrome (BCIS) is characterized by hypoxia, hypotension, cardiac arrhythmias, increased pulmonary vascular resistance and cardiac arrest. It is a known cause of morbidity and mortality in patients undergoing cemented orthopaedic surgeries. The rarity of the condition as well as absence of a proper definition has contributed to under-reporting of cases. We report a 59-year-old woman who sustained fracture of the neck of her left femur and underwent an elective hybrid total hip replacement surgery. She collapsed during surgery and was revived only to succumb to death twelve hours later. Post mortem findings showed multiorgan disseminated microembolization of bone marrow and amorphous cement material.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects*
  2. Abbas AA, Kim YJ, Song EK, Yoon TR
    J Arthroplasty, 2009 Oct;24(7):1144.e5-8.
    PMID: 18848418 DOI: 10.1016/j.arth.2008.09.008
    The causes of groin pain after total hip arthroplasty are numerous, and the condition itself is disabling. Therefore, it is imperative that the cause of the pain is identified and managed appropriately. We report a case where the patient had groin pain after total hip arthroplasty as a result of an oversized cementless acetabular component, which caused a breach in the anterior wall of the acetabulum. The anterior wall of the acetabulum was reconstructed with femoral head allograft, and the patient has been symptom free since.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects*
  3. Chiu CL, Ong GS
    Ann Acad Med Singap, 2000 Mar;29(2):256-8.
    PMID: 10895351
    INTRODUCTION: We report a case of subcutaneous emphysema and pneumomediastinum that presented postoperatively after tracheal extubation.

    CLINICAL PICTURE: A 51-year-old man had an uneventful anaesthesia lasting about 6.5 hours. Intubation was performed by a very junior medical officer and was considered difficult. He developed sore throat, chest pain, numbness of both hands and palpable crepitus around the neck postoperatively. Chest X-ray revealed diffuse subcutaneous emphysema, pneumomediastinum and possible pneumopericardium.

    TREATMENT: He was treated conservatively with bed rest, oxygen, analgesia, antibiotic prophylaxis, reassurance and close monitoring.

    OUTCOME: The patient made an uneventful recovery.

    CONCLUSIONS: We discussed the possible causes.

    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  4. Yong KS, Kareem BA, Ruslan GN, Harwant S
    Med J Malaysia, 2001 Jun;56 Suppl C:57-60.
    PMID: 11814251 MyJurnal
    Sixty-seven primary THR surgeries in 57 patients between January 1992 and December 1998 were reviewed after a mean follow-up of 35.9 months. The rate of superficial and deep wound infections were 11.9% and 1.5% respectively. The most common organism in superficial wound infection was Staphylococcus aureus. The factors that were significantly associated with superficial wound infection were diabetes mellitus (p= 0.0230) obesity (p=0.0088). The patients who developed superficial wound infection have a significantly longer duration of surgery compared to patients without infection (p=0.014). However, there was no significant difference between the mean age among patients with and without superficial wound infection (p=0.814).
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects*
  5. Park KS, Chan CK, Kim SK, Li QS, Im CJ, Yoon TR
    J Orthop Sci, 2019 May;24(3):452-457.
    PMID: 30415823 DOI: 10.1016/j.jos.2018.10.016
    BACKGROUND: Due to concern of potential metallosis caused by residual microscopic ceramic particles, metal-on-metal (MoM) bearing is deemed undesirable in revision total hip arthroplasty (THA) for ceramic bearing fracture. We determined whether MoM bearing is suitable to be used in revision THA for ceramic fractures and also evaluated whether this treatment increases serum iron levels compared with MoM bearing revision THA for polyethylene failure.

    METHODS: Between 2006 and 2012, 22 patients underwent revision surgery using MoM bearing (28 mm femoral head in 18 hips and 32 mm in 4 hips) for ceramic bearing fracture and followed average 52.1 months. We assessed radiological parameter and functional outcome using Harris hip score (HHS) and WOMAC score. Also, serum cobalt (Co) and chromium (Cr) blood tests were performed and compared with the result obtained from age, sex- and follow-up duration-matched patients with MoM revision THA for failed polyethylene bearing.

    RESULTS: The mean HHS improved from 60.6 preoperatively to 90.3 at final follow-up. There were no changes in cup position, progression of osteolytic lesions, and measurable wear of MoM bearing articulation at final follow-up radiographs. There was one case of recurrent dislocation after surgery, which was treated with greater trochanter distal advancement and one case of deep infection, which underwent two-stage revision. Mean serum Co level (1.7 vs. 1.4 μg/dl; p = 0.211) and Cr level (0.70 vs. 1.01 μg/dl; p = 0.327) showed no significant difference.

    CONCLUSIONS: MoM articulation with liner cementation into the acetabular cup along with total synovectomy can be chosen in revision surgery for ceramic fracture with good midterm follow-up. However, the use of MoM bearing is indicated when the stem and metal shell can be retained and ceramic on ceramic or ceramic on polyethylene bearing cannot be selected. Also long-term outcome needs to be further evaluated.

    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  6. Rosenthal VD, Richtmann R, Singh S, Apisarnthanarak A, Kübler A, Viet-Hung N, et al.
    Infect Control Hosp Epidemiol, 2013 Jun;34(6):597-604.
    PMID: 23651890 DOI: 10.1086/670626
     To report the results of a surveillance study on surgical site infections (SSIs) conducted by the International Nosocomial Infection Control Consortium (INICC).
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  7. Mohd Fuad D, Masbah O, Shahril Y, Jamari S, Norhamdan MY, Sahrim SH
    Med J Malaysia, 2006 Feb;61 Suppl A:27-9.
    PMID: 17042225
    Antibiotic-loaded bone cement has been used as prophylaxis against infection in total joint replacement surgery. Its effect on the mechanical strength of cement is a major concern as high dose of antibiotic was associated with a significant reduction in mechanical strength of bone cement. However, the cut-off antibiotic that weakens the mechanical strength of cement remains to be determined. This study was undertaken to observe the changes in the mechanical properties of bone cement with gradual increments of Cefuroxime antibiotic. Cefuroxime at different doses: 0, 1.5, 3.0 and 4.5gm were added to a packet of 40gm bone cement (Simplex P) and study samples were prepared by using third generation cementing technique. Mechanical impact, flexural and tensile strength were tested on each sample. Significant impact and tensile strength reduction were observed after addition of 4.5 gm of Cefuroxime. However, flexural strength was significantly reduced at a lower dose of 3.0 gm. The maximum dose of Cefuroxime to be safely added to 40mg Surgical Simplex P is 1.5gm when third generation cementing technique is used. Further study is needed to determine whether it is an effective dose as regards to microbiological parameters.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  8. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects*
Filters