OBJECTIVE: In order to address this issue, we analyzed how leg muscle activity is related to the variations of the path of movement.
METHOD: Since the electromyography (EMG) signal is a feature of muscle activity and the movement path has complex structures, we used entropy analysis in order to link their structures. The Shannon entropy of EMG signal and walking path are computed to relate their information content.
RESULTS: Based on the obtained results, walking on a path with greater information content causes greater information content in the EMG signal which is supported by statistical analysis results. This allowed us to analyze the relation between muscle activity and walking path.
CONCLUSION: The method of analysis employed in this research can be applied to investigate the relation between brain or heart reactions and walking path.
OBJECTIVE: In this research, for the first time, we investigate how facial muscle reaction is related to the reaction of the human brain.
METHODS: Since both electromyography (EMG) and electroencephalography (EEG) signals, as the features of muscle and brain activities, contain information, we benefited from the information theory and computed the Shannon entropy of EMG and EEG signals when subjects were exposed to different static visual stimuli with different Shannon entropies (information content).
RESULTS: Based on the obtained results, the variations of the information content of the EMG signal are related to the variations of the information content of the EEG signal and the visual stimuli. Statistical analysis also supported the results indicating that the visual stimuli with greater information content have a greater effect on the variation of the information content of both EEG and EMG signals.
CONCLUSION: This investigation can be further continued to analyze the relationship between facial muscle and brain reactions in case of other types of stimuli.
Methods: A total of eighteen (18) malocclusion patients were identified. Malocclusion patients were subdivided into 3 groups based on the bracket selection (conventional, self-ligating, and ceramic bracket) with 6 patients for each group. sEMG of muscles were done using a two-channel electromyography device, where pregelled and self-adhesive electrodes (bilateral) were applied. Chewing and clenching of masseter and temporalis muscle activity were recorded for 20 s pre and 6 months of orthodontic treatment using sEMG (frequency 60 Hz). The data were analysed by using repeated measures ANOVA in IBM SPSS Statistics Version 24.0.
Results: Chewing and clenching for masseter muscle showed no significant difference (P > 0.05) in sEMG activity of three types of the brackets. However, for temporalis muscle, there was a significant difference found in sEMG activity during chewing (P < 0.05) and clenching (P < 0.05) between these three brackets.
Conclusion: The activity of temporalis muscle showed significant changes in chewing and clenching, where the conventional group demonstrated better muscle activity pre and at six months of fixed appliances.
METHODS: MMG and EMG were used to record the activity of the SCM in 32 untrained singers reciting a monotonous text and a standard folk song. Their voices were recorded and their pitch, or fundamental frequency (FF), and intensity were derived using Praat software. Instants of inhale and exhales were identified during singing from their voice recordings and the corresponding SCM MMG and EMG activities were analysed.
RESULTS: The SCM MMG, and EMG signals during breathing while singing were significantly different than breathing at rest (p < 0.001). On the other hand, MMG was relatively better correlated to voice intensity in both reading and singing than EMG. EMG was better, but not significantly, correlated with FF in both reading and singing as compared to MMG.
CONCLUSIONS: This study established MMG and EMG as the quantitative measurement tool to monitor breathing activities during singing. This is useful for applications related to singing therapy performance measure including potentially pathologically effected population. While the MMG and EMG could not distinguish FF and intensity significantly, it is useful to serve as a proxy of inhalation and exhalation levels throughout a particular singing session. Further studies are required to determine its efficacy in a therapeutic setting.