METHODS: A 40-question anonymous online questionnaire was distributed to anesthesiologists and anesthesia trainees in six countries in the Asia-Pacific (Singapore, Malaysia, Philippines, Thailand, India and South Korea). Participants were polled about their current practices in patient warming and temperature measurement across the preoperative, intraoperative and postoperative periods. Questions were also asked regarding various individual and environmental barriers to compliance.
RESULTS: In total, 1154 valid survey responses were obtained and analyzed. 279 (24.2%) of respondents prewarm, 508 (44.0%) perform intraoperative active warming, and 486 (42.1%) perform postoperative active warming in the majority of patients. Additionally, 531 (46.0%) measure temperature preoperatively, 767 (67.5%) measure temperature intraoperatively during general anesthesia, and 953 (82.6%) measure temperature postoperatively in the majority of patients. The availability of active warming devices in the operating room (p
CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.
CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.
MATERIAL AND METHODS: A total of 80 adult patients who were scheduled for elective surgery under general anaesthesia were randomised to two groups: Group BM: Baska mask (n = 40) and Group IG: i-gel (n = 40). The assessment focused on ease of insertion, number of attempts, insertion time, number of corrective manoeuvres, oropharyngeal leak pressure, tidal volume, peak airway pressure (PAP) and post-insertion complications.
RESULTS: Group IG showed a significantly shorter median insertion time (13.3 [interquartile range, IQR 7.8] vs. 17.0 [IQR 9.6] s; P < 0.001), a higher percentage in the 'very easy' ease of insertion category (62.5% vs. 10.0%; P < 0.001), a higher percentage in the no corrective manoeuvre category (92.5% vs. 72.5%; P = 0.003) and a higher percentage in the no post-operative throat pain category (67.5% vs. 32.5%; P = 0.011) than Group BM. However, Group BM showed a significantly higher generated PAP than Group IG (12.7 [1.8] and 11.5 [2.2] cm H2O, respectively; P = 0.010). There were no significant differences in other parameters.
CONCLUSIONS: The i-gel was better than the Baska mask in terms of ease of insertion, speed of insertion, fewer corrective manoeuvres and less post-operative throat pain. However, the Baska mask had a better cuff seal, as shown by a higher generated PAP.
MATERIAL AND METHODS: A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.
RESULTS: he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.
CONCLUSIONS: The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.
OBJECTIVE: The objective of this study was to determine whether combined total intravenous anesthesia (TIVA) technique with propofol/remifentanil is associated with less SSEP suppression when compared to combined volatile agent desflurane/remifentanil anesthesia during corrective scoliosis surgery at a comparable depth of anesthesia.
DESIGN: It is a randomized controlled trial.
SETTING: The study was conducted at the Single tertiary University Hospital during October 2014 to June 2015.
PATIENTS: Patients who required SSEP and had no neurological deficits, and were of American Society of Anesthesiologist I and II physical status, were included. Patients who had sensory or motor deficits preoperatively and significant cardiovascular and respiratory disease were excluded. A total of 72 patients were screened, and 67 patients were randomized and allocated to two groups: 34 in desflurane/remifentanil group and 33 in TIVA group. Four patients from desflurane/remifentanil group and three from TIVA group were withdrawn due to decrease in SSEP amplitude to <0.3 µV after induction of anesthesia. Thirty patients from each group were analyzed.
INTERVENTIONS: Sixty-seven patients were randomized to receive TIVA or desflurane/remifentanil anesthesia.
MAIN OUTCOME MEASURES: The measurements taken were the amplitude and latency of SSEP monitoring at five different time points during surgery: before and after the induction of anesthesia, at skin incision, at pedicle screw insertion, and at rod insertion.
RESULTS: Both anesthesia techniques, TIVA and desflurane/remifentanil, resulted in decreased amplitude and increased latencies of both cervical and cortical peaks. The desflurane/remifentanil group had a significantly greater reduction in the amplitude ( p = 0.004) and an increase in latency ( p = 0.002) of P40 compared with the TIVA group. However, there were no differences in both amplitude ( p = 0.214) and latency ( p = 0.16) in cervical SSEP between the two groups.
CONCLUSIONS: Compared with TIVA technique, desflurane/remifentanil anesthesia caused more suppression in cortical SSEP, but not in cervical SSEP, at a comparable depth of anesthesia.