METHODS: A total of 108 pleural, peritoneal, and pericardial effusions/washings diagnosed as unequivocally reactive (n = 41) and metastatic carcinoma (n = 67) by cytomorphology over 18 months were reviewed. Among the metastatic carcinoma cases, 54 were adenocarcinoma and others were squamous cell carcinoma (n = 1), carcinosarcoma (n = 1), and carcinoma of undefined histological subtypes (n = 11). Cell block sections were immunostained by EZH2 (Cell Marque, USA). The percentages of EZH2-immunolabeled cells over the total cells of interest were calculated. Receiver operating characteristic (ROC) curve analysis was performed to determine the optimal cut-off score to define EZH2 immunopositivity.
RESULTS: A threshold of 8% EZH2-immunolabeled cells allows distinction between malignant and reactive mesothelial cells, with 95.5% sensitivity, 100% specificity, 100% positive predictive value, and 93.2% negative predictive value (p < 0.0001). The area under the curve was 0.988.
CONCLUSION: EZH2 is a promising diagnostic biomarker for malignancy in effusion cytology which is inexpensive yet trustworthy and could potentially be used routinely in countries under considerable economic constraints.
METHODS: This prospective cohort study was conducted at Hospital Universiti Sains Malaysia (USM) from 1st October 2016 to 30th November 2017. Serial bedside ultrasound procedures were performed for 83 patients who were diagnosed as having dengue fever without warning signs and were initially treated as outpatients. Ultrasonography evidence of plasma leakage either pleural effusion, thickened gallbladder wall, ascites or pericardial effusion were compared with clinical findings and laboratory parameters for plasma leakage.
RESULTS: Of the 83 dengue patients, eventually 72.3% had dengue fever with warning signs and 6.0% had severe dengue fever. There were 38 patients who had subclinical plasma leakage at initial presentation, 84.2% and 7.9% of them then progressed to dengue fever with warning signs and severe dengue respectively. There was a minimal agreement between serial bedside ultrasound and haematocrit level in the detection of plasma leakage (observed kappa 0.135).
CONCLUSIONS: Serial bedside ultrasound is an adjunct procedure to physical examination and may detect plasma leakage earlier compared to haemoconcentration. The early usage of serial ultrasound is of paramount importance in detecting dengue patients who are at risk of progressing to severe dengue.
CASE PRESENTATION: A young man involved in a car accident and sustained blunt thoracic injuries, among others. As part of primary survey, FAST scan was performed. Subxiphoid view to look for evidence of pericardial effusion showed part of the cardiac image obscured by A-lines. Other cardiac windows showed only A-lines, as well. A suspicion of pneumopericardium was raised and CT scan confirmed the diagnosis.
CONCLUSIONS: Although FAST scan was originally used to look for presence of free fluid, with the knowledge of lung ultrasound for pneumothorax, our findings suggest that FAST scan can also be used to detect pneumopericardium.