Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Chik Z, Johnston A, Tucker AT, Kirby K, Alam CA
    Int J Clin Pharmacol Ther, 2009 Apr;47(4):262-8.
    PMID: 19356392
    Circulating concentrations of endogenous compounds such as testosterone, complicate the analysis of pharmacokinetic parameters when these compounds are administered exogenously. This study examines the influence of three correction methods of accounting for endogenous concentrations on the determination of bioequivalence between two testosterone formulations.
    Matched MeSH terms: Therapeutic Equivalency
  2. Chua GN, Hassali MA, Shafie AA, Awaisu A
    Health Policy, 2010 May;95(2-3):229-35.
    PMID: 20044165 DOI: 10.1016/j.healthpol.2009.11.019
    OBJECTIVES: The objective of this study was to evaluate the general practitioners' (GPs') knowledge and perceptions towards generic medicines in a northern state of Malaysia.
    METHOD: A postal cross-sectional survey involving registered GPs in Penang, Malaysia was undertaken. A 23-item questionnaire was developed, validated and administered on the GPs. Eighty-seven GPs responded to the survey (response rate 26.8%).
    RESULTS: The majority of the respondents (85.1%) claimed that they actively prescribed generic medicines in their practice. On the other hand, only 4.6% of the respondents correctly identified the Malaysia's National Pharmaceutical Control Bureau's bioequivalence standard for generic products. There were misconceptions among the respondents about the concepts of "bioequivalence", "efficacy", "safety", and "manufacturing standards" of generic medicines. GPs in this survey believed that a standard guideline on brand substitution process, collaboration with pharmacists, patient education and information on safety and efficacy of generic medicines were necessary to ensure quality use of generics. Furthermore, advertisements and product bonuses offered by pharmaceutical companies, patient's socio-economic factors as well as credibility of manufacturers were factors reported to influence their choice of medicine.
    CONCLUSION: Although it appeared that GPs have largely accepted the use of generic medicines, they still have concerns regarding the reliability and quality of such products. GPs need to be educated and reassured about generic products approval system in Malaysia concerning bioequivalence, quality, and safety. The current findings have important implications in establishing generic medicines policy in Malaysia.
    Matched MeSH terms: Therapeutic Equivalency
  3. Chong CP, March G, Clark A, Gilbert A, Hassali MA, Bahari MB
    Health Policy, 2011 Feb;99(2):139-48.
    PMID: 20732723 DOI: 10.1016/j.healthpol.2010.08.002
    This study evaluated Australian community pharmacists' rate of generic medicine substitution, patient acceptance of generic substitution and cost-savings achieved for patients from substitution.
    Matched MeSH terms: Therapeutic Equivalency
  4. Yuen KH, Wong JW, Yap SP, Billa N
    Int J Clin Pharmacol Ther, 2001 Jan;39(1):37-40.
    PMID: 11204936
    OBJECTIVE: The aim of the present communication is to provide information regarding the intrasubject coefficent of variation obtained from 30 bioequivalence studies covering 16 drugs which can be used for estimation of sample size. Additionally, an attempt was also made to estimate the test power of each of the studies conducted.

    METHODS: The intrasubject coefficient of variation was estimated from the residual mean square error obtained from analysis of variance of the parameters AUC0-infinity, Cmax and Cmax/AUC0-infinity after logarithmic transformation. The test power in the analyses of the above parameters was subsequently estimated using nomograms provided by Diletti et al. [1991].

    RESULTS AND CONCLUSION: Thirty products covering 16 drugs were studied in which 22 were immediate-release (including one dispersible tablet) and 8 were sustained-release formulations. The intrasubject coefficient of variation for the parameter AUC0-infinity was smaller than Cmax, and hence considerably more studies were able to attain a power of greater than 80% using 12 volunteers for the AUC0-infinity, compared to the Cmax. However, the variability in the Cmax could be reduced by using the parameter Cmax/ AUC0-infinity, and thus, provide a more realistic estimation of sample size, since the latter reflects only the rate of absorption and not both the rate and extent as in the case of Cmax [Endrenyi et al. 1991].

    Matched MeSH terms: Therapeutic Equivalency
  5. Khwairakpam G, Burry J
    Curr Opin HIV AIDS, 2019 01;14(1):1-6.
    PMID: 30480583 DOI: 10.1097/COH.0000000000000514
    PURPOSE OF REVIEW: With increasing availability of generic direct-acting antivirals (DAAs) and associated price reductions, various governments, multilateral institutions, and donors have started providing testing and treatment for hepatitis C virus (HCV) infection. More data on the quality of these generic medicines and on cost-effectiveness of their use are becoming widely available. This review seeks to describe some of the treatment programs for HCV that are evolving in Cambodia, India, Indonesia, Malaysia, Myanmar, and Thailand.

    RECENT FINDINGS: The quality of multiple generic DAAs has been shown to be bioequivalent to innovator formulations, with generic versions achieving high cure rates in real-world settings. Although published materials are limited, there is expanding experience with local pilot and national treatment programs which are largely being funded by national governments and other institutions.

    SUMMARY: Countries and other public health stakeholders are recognizing the need to scale up HCV diagnosis and treatment programs using generic DAAs. However, local pilot or national treatment programs need to be massively expanded to eliminate HCV in high-burden areas.

    Matched MeSH terms: Therapeutic Equivalency
  6. Atif M, Khalid SH, Onn Kit GL, Sulaiman SA, Asif M, Chandersekaran A
    J Young Pharm, 2013 Mar;5(1):26-9.
    PMID: 24023449 DOI: 10.1016/j.jyp.2013.01.005
    A simple, sensitive and selective HPLC method with UV detection for determination of Glipizide in human plasma was developed. Liquid-liquid extraction method was used to extract the drug from the plasma samples. Chromatographic separation of Glipizide was achieved using C18 column (ZORBAX ODS 4.6 × 150 mm). The mobile phase was comprised of 0.01 M potassium dihydrogen phosphate and acetonitrile (65:35, v/v) adjusted to pH 4.25 with glacial acetic acid. The analysis was run at a flow rate of 1.5 mL/min with an injection volume was 20 μL. The detector was operated at 275 nm. The calibration curve was linear over a concentration range of 50-1600 ng/mL. Intra-day and inter-day precision and accuracy values were below 15%. The limit of quantification was 50 ng/mL and the mean recovery was above 98%. Freeze-thaw, short-term, long-term and post-preparative stability studies showed that Glipizide in plasma sample was stable. The method may be successfully applied to analyze the Glipizide concentration in plasma samples for bioavailability and bioequivalence studies.
    Matched MeSH terms: Therapeutic Equivalency
  7. Charoo NA, Shamsher AA, Lian LY, Abrahamsson B, Cristofoletti R, Groot DW, et al.
    J Pharm Sci, 2014 Feb;103(2):378-91.
    PMID: 24382794 DOI: 10.1002/jps.23817
    Literature data relevant to the decision to allow a waiver of in vivo bioequivalence (BE) testing for the approval of immediate-release (IR) solid oral dosage forms containing bisoprolol as the sole active pharmaceutical ingredient (API) are reviewed. Bisoprolol is classified as a Class I API according to the current Biopharmaceutics Classification System (BCS). In addition to the BCS class, its therapeutic index, pharmacokinetic properties, data related to the possibility of excipient interactions, and reported BE/bioavailability problems are taken into consideration. Qualitative compositions of IR tablet dosage forms of bisoprolol with a marketing authorization (MA) in ICH (International Conference on Harmonisation) countries are tabulated. It was inferred that these tablets had been demonstrated to be bioequivalent to the innovator product. No reports of failure to meet BE standards have been made in the open literature. On the basis of all these pieces of evidence, a biowaiver can currently be recommended for bisoprolol fumarate IR dosage forms if (1) the test product contains only excipients that are well known, and used in normal amounts, for example, those tabulated for products with MA in ICH countries and (2) both the test and comparator dosage form are very rapidly dissolving, or, rapidly dissolving with similarity of the dissolution profiles demonstrated at pH 1.2, 4.5, and 6.8.
    Matched MeSH terms: Therapeutic Equivalency
  8. Sharrad AK, Hassali MA
    Res Social Adm Pharm, 2011 Mar;7(1):108-12.
    PMID: 21397885 DOI: 10.1016/j.sapharm.2009.12.003
    BACKGROUND: The use of generic medicines has been increasing steadily internationally, primarily because of cost concerns. Knowledge and use patterns of generic medicines in Iraq have not yet been measured.
    OBJECTIVE: This study aimed to explore consumers' perception and knowledge on issues relating to generic medicine use in Basrah, Iraq.
    METHODS: A qualitative approach was used to gather information from consumers in Basrah, Iraq. A purposive sample of 14 consumers in Basrah was interviewed face-to-face using a semistructured interview guide.
    RESULTS: Thematic analysis of the interviews identified 5 major themes: understanding of the term "generic medicine," preference for generic medicine, refusal of generic medicine, generic substitution, and education on the use of generic medicines. Not all the consumers were familiar with the term "generic medicine;" they were familiar with the term "commercial medicine." Most of the participants understood that generics cost less compared with their branded counterparts. Most of the consumers said that their physicians and pharmacists had given them information on generics.
    CONCLUSION: Knowledge of generic medicines may be lacking among consumers in Iraq. Development of consumer education on generics by health care providers is required to support the implementation of the policy on generic medicines in Iraq.
    Matched MeSH terms: Therapeutic Equivalency
  9. Hassan Y, Alfadly SO, Azmin MN, Peh KK, Tan TF, Noorizan AA, et al.
    Singapore Med J, 2007 Sep;48(9):819-23.
    PMID: 17728962
    A bioequivalence study of two oral formulations of 500 mg tablets of ciprofloxacin (RAZA Pharmaniaga, Malaysia) as test and Ciprobay (Bayer AG, Germany) as reference, was carried out in 24 healthy human volunteers. Each volunteer received a single dose of ciprofloxacin.
    Matched MeSH terms: Therapeutic Equivalency
  10. Kumar R, Hassali MA, Saleem F, Alrasheedy AA, Kaur N, Wong ZY, et al.
    J Pharm Policy Pract, 2015;8(1):11.
    PMID: 25861452 DOI: 10.1186/s40545-015-0031-9
    OBJECTIVES: Generic medicine prescribing has become a common practice in public hospitals. However, the trend in private medical centres seems to be different. The objective of this study was to investigate knowledge, perceptions and behavior of physicians from private medical centres in Malaysia regarding generic medicines.

    METHODS: This study was a cross-sectional nationwide survey targeting physicians from private medical centres in Malaysia. The survey was conducted using questionnaire having (i) background and demographic data of the physicians, volume of prescription in a day, stock of generic medicines in their hospital pharmacy etc. (ii) their knowledge about bioequivalence (iii) prescribing behavior (iv) physicians' knowledge of quality, safety and efficacy of generic medicines, and their cost (v) perceptions of physicians towards issues pertaining to generic medicines utilization.

    RESULTS: A total of 263 questionnaires out of 735 were received, giving a response rate of 35.8%. Of the respondents, 214 (81.4%) were male and 49 (18.6%) were females. The majority of the participants were in the age range of 41-50 years and comprised 49.0% of the respondents. Only 2.3% of physicians were aware of the regulatory limits of bioequivalence standards in Malaysia. Of the respondents, 23.2% agreed that they 'always' write their prescriptions using originator product name whereas 50.2% do it 'usually'. A number of significant associations were found between their knowledge, perceptions about generic medicines and their demographic characteristics.

    CONCLUSIONS: The majority of the physicians from private medical centres in Malaysia had negative perceptions about safety, quality and the efficacy of generic medicines. These negative perceptions could be the cause of the limited use of generic medicines in the private medical centres. Therefore, in order to facilitate their use, it is recommended that the physicians need to be reassured and educated about the drug regulatory authority approval system of generic medicines with regard to their bioequivalence, quality, efficacy and safety. Apart from the policy on generic substitution, it would also be recommended to have a national medicine pricing policy, which controls drug prices, in both the public and private sector. These efforts are worthwhile to reduce the drug expenditure and improve the medicine affordability in Malaysia.

    Matched MeSH terms: Therapeutic Equivalency
  11. Izadi E, Afshan G, Patel RP, Rao VM, Liew KB, Meor Mohd Affandi MMR, et al.
    Front Pharmacol, 2019;10:881.
    PMID: 31474853 DOI: 10.3389/fphar.2019.00881
    Counterfeit and substandard medicines are recognized as one of serious threats to public health. The product quality of antibacterial medicine will compromise patients' recovery and increase the chance of antibacterial resistance. The review aims to provide a summary of low quality levofloxacin issues and the risk factors as well as suggesting the aspects of product quality that need to be regulated strictly. Quality of the active ingredient, levofloxacin, has an important role to contribute to successful therapy. The poor quality of raw material, directly and indirectly, causes treatment failure as the presence of insufficient dose, mislabeled content, and poor dissolution characteristics can lead to lower bioavailability. Identifying and reporting these factors can potentially help in improving the quality of drug marketed in various developing countries and may also reduce the incidences of treatment failure. Dissolution test is used for testing the dissolution profiles and the rate of drug release from solid formulation such as oral formulations, thus providing information regarding the in vivo performance of a formulation and its bioequivalence. On the other hand, quality-testing procedures are used for comparing the quality of products.
    Matched MeSH terms: Therapeutic Equivalency
  12. Sharma D, Patel RP, Zaidi STR, Sarker MMR, Lean QY, Ming LC
    Front Pharmacol, 2017;8:546.
    PMID: 28871228 DOI: 10.3389/fphar.2017.00546
    Ciprofloxacin, a second generation broad spectrum fluoroquinolone, is active against both Gram-positive and Gram-negative bacteria. Ciprofloxacin has a high oral bioavailability and a large volume of distribution. It is used for the treatment of a wide range of infections including urinary tract infections caused by susceptible bacteria. However, the availability and use of substandard and spurious quality of oral ciprofloxacin formulations in the developing countries has been thought to have contributed toward increased risk of treatment failure and bacterial resistance. Therefore, quality control and bioequivalence studies of the commercially available oral ciprofloxacin formulations should be monitored. Appropriate actions should be taken against offending manufacturers in order to prevent the sale of substandard and spurious quality of ciprofloxacin formulations.
    Matched MeSH terms: Therapeutic Equivalency
  13. Bukhari NI, Zafar A, Shamsi Wu, Bashir MA, Mirza AA
    Therapie, 2005 Mar-Apr;60(2):167-73.
    PMID: 15969319
    AIM: The bioequivalence of aspirin from two enteric-coated brands, Nu-seals and Loprin, identified as the reference (R) and test (T) products, respectively, was assessed.

    METHODS: A two-period randomised crossover design with a washout interval of 15 days was used in this study. The study results were determined in 16 healthy volunteers, all males with ages ranging from 19-28 (23.33 +/- 3.74) years and bodyweights of 52-92 (65.89 +/- 11.39) kg. After oral ingestion of 150mg of the either brand with 200 mL of water, serial blood samples were obtained over a period of 24 hours. Plasma, harvested from blood was analysed for the concentration of salicylic acid, a deacetylated metabolite of aspirin, by a validated high performance liquid chromatography (HPLC) method. Pharmacokinetic parameters were determined for both formulations by an interactive computer-assisted PK II procedure. A general linear model for repeated measures and 90% confidence intervals (CI) was employed to assess the sequence of treatment effects and to exclude differences between the parameters due to the product and period of administration, respectively.

    RESULTS: The observed 90% CI ratios (Loprin/Nu-seals) for peak concentration, time to reach the peak and area under the plasma-concentration time curve from zero to infinity of 1.03,1.08; 1.04,1.05 and 1.01,1.15, respectively, were within the bioequivalence range (0.80,1.25) stipulated by the US Food and Drug Administration.

    CONCLUSION: On the basis of the findings, the test (Loprin) and reference drug (Nu-seals) were deemed bioequivalent.
    Matched MeSH terms: Therapeutic Equivalency
  14. Chik Z, Basu RC, Pendek R, Lee TC, Mohamed Z
    Clin Ther, 2010 Sep;32(10):1822-31.
    PMID: 21194606 DOI: 10.1016/j.clinthera.2010.09.006
    Rifampicin is a semisynthetic antibiotic derivative of rifamycin used worldwide for the treatment of various forms of tuberculosis.
    Matched MeSH terms: Therapeutic Equivalency
  15. Tassaneeyakul W, Kumar S, Gaysonsiri D, Kaewkamson T, Khuroo A, Tangsucharit P, et al.
    Int J Clin Pharmacol Ther, 2010 Sep;48(9):614-20.
    PMID: 20860915
    OBJECTIVES: To compare the bioavailability of two risperidone orodispersible tablet products, Risperidone 1 mg Mouth dissolving tablet, Ranbaxy (Malaysia) Sdn. Bhd., Malaysia, as a test product and Risperdal 1 mg Quicklet, Janssen Ortho LLC, Gurabo, Puerto Rico, as a reference product, in healthy male volunteers under fasting condition.

    MATERIALS AND METHODS: A randomized, 2-treatment, 2-period, 2-sequence, single dose, crossover with a washout period of 2 weeks, was conducted in 24 healthy Thai male volunteers. Blood samples were collected at 0, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 24, 36, 48, 72 and 96 h following drug administration. Plasma concentrations of risperidone and 9-hydroxyrisperidone were determined using a validated LC-MS-MS method. The pharmacokinetic parameters of risperidone and 9-hydroxyrisperidone were determined using a non-compartmental model.

    RESULTS: The geometric means ratios (%) and 90% confidence interval (CI) of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of risperidone were 104.49 % (92.79% - 117.66%), 100.96 % (92.15% - 110.61 %) and 97.99 % (90.72% - 105.85%). The 90% CI of geometric means ratios of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of 9-hydroxyrisperidone were 97.00%, 96.97% and 97.49%.

    CONCLUSIONS: The 90% CI for the geometric means ratios (test/reference) of the log-trasformed Cmax, AUC0-t and AUC0-inf of risperidone and its major active metabolite were within the bioequivalence acceptance criteria of 80% - 125% of the US-FDA.

    Matched MeSH terms: Therapeutic Equivalency
  16. Juhlin K, Karimi G, Andér M, Camilli S, Dheda M, Har TS, et al.
    Drug Saf, 2015 Apr;38(4):373-82.
    PMID: 25687792 DOI: 10.1007/s40264-015-0271-2
    Substandard medicines, whether the result of intentional manipulation or lack of compliance with good manufacturing practice (GMP) or good distribution practice (GDP), pose a significant potential threat to patient safety. Spontaneous adverse drug reaction reporting systems can contribute to identification of quality problems that cause unwanted and/or harmful effects, and to identification of clusters of lack of efficacy. In 2011, the Uppsala Monitoring Centre (UMC) constructed a novel algorithm to identify reporting patterns suggestive of substandard medicines in spontaneous reporting, and applied it to VigiBase(®), the World Health Organization's global individual case safety report database. The algorithm identified some historical clusters related to substandard products, which were later able to be confirmed in the literature or by contact with national centres (NCs). As relevant and detailed information is often lacking in the VigiBase reports but might be available at the reporting NC, further evaluation of the algorithm was undertaken with involvement from NCs.
    Matched MeSH terms: Therapeutic Equivalency
  17. Ibahim MJ, Crosbie JC, Yang Y, Zaitseva M, Stevenson AW, Rogers PA, et al.
    PLoS One, 2014;9(6):e100547.
    PMID: 24945301 DOI: 10.1371/journal.pone.0100547
    High-dose synchrotron microbeam radiation therapy (MRT) has shown the potential to deliver improved outcomes over conventional broadbeam (BB) radiation therapy. To implement synchrotron MRT clinically for cancer treatment, it is necessary to undertake dose equivalence studies to identify MRT doses that give similar outcomes to BB treatments.
    Matched MeSH terms: Therapeutic Equivalency
  18. Pandian RU
    Maturitas, 2009 Dec;65 Suppl 1:S47-50.
    PMID: 20005647 DOI: 10.1016/j.maturitas.2009.11.016
    Threatened miscarriage is a common problem during pregnancy.
    Matched MeSH terms: Therapeutic Equivalency
  19. Liew KB, Loh GO, Tan YT, Peh KK
    Biomed Chromatogr, 2015 Jun;29(6):953-60.
    PMID: 25400284 DOI: 10.1002/bmc.3378
    A simple, rapid, specific and reliable UFLC coupled with ESI-MSMS assay method to simultaneously quantify sildenafil and N-desmethyl sildenafil, with loperamide as internal standard, was developed. Chromatographic separation was performed on a Thermo Scientific Accucore C18 column with an isocratic mobile phase composed of 0.1% v/v formic acid in purified water-methanol (20:80, v/v), at a flow rate of 0.3 mL/min. Sildenafil, N-desmethyl sildenafil and loperamide were detected with proton adducts at m/z 475.4 > 58.2, 461.3 > 85.2 and 477.0 > 266.1 in multiple reaction monitoring positive mode, respectively. Both analytes and internal standard were extracted by diethyl ether. The method was validated over a linear concentration range of 10-800 ng/mL for sildenafil and 10-600 ng/mL for N-desmethyl sildenafil with correlation coefficient (r(2) ) ≥0.9976 for sildenafil and (r(2) ) ≥0.9992 for N-desmethyl sildenafil. The method was precise, accurate and stable. The proposed method was applied to study the bioequivalence between a 100 mg dose of two pharmaceutical products: Viagra (original) and Edyfil (generic) products. AUC0-t , Cmax and Tmax were 2285.79 ng h/mL, 726.10 ng/mL and 0.94 h for Viagra and 2363.25 ng h/mL, 713.91 ng/mL and 0.83 hour for Edyfil. The 90% confidence interval of these parameters of this study fall within the regulatory range of 80-125%, hence they are considered as bioequivalent.
    Matched MeSH terms: Therapeutic Equivalency
  20. Liew KB, Loh GO, Tan YT, Peh KK
    Biomed Chromatogr, 2014 Sep;28(9):1246-53.
    PMID: 24585432 DOI: 10.1002/bmc.3153
    The objectives of this study were to develop a new deproteinization method to extract amoxicillin from human plasma and evaluate the inter-ethnic variation of amoxicillin pharmacokinetics in healthy Malay volunteers. A single-dose, randomized, fasting, two-period, two-treatment, two-sequence crossover, open-label bioequivalence study was conducted in 18 healthy Malay adult male volunteers, with one week washout period. The drug concentration in the sample was analyzed using high-performance liquid chromatography (UV-vis HPLC). The mean (standard deviation) pharmacokinetic parameter results of Moxilen® were: peak concentration (Cmax ), 6.72 (1.56) µg/mL; area under the concentration-time graph (AUC0-8 ), 17.79 (4.29) µg/mL h; AUC0-∞ , 18.84 (4.62) µg/mL h. Those of YSP Amoxicillin® capsule were: Cmax , 6.69 (1.44) µg/mL; AUC0-8 , 18.69 (3.78) µg/mL h; AUC00-∞ , 19.95 (3.81) µg/mL h. The 90% confidence intervals for the logarithmic transformed Cmax , AUC0-8 and AUC0-∞ of Moxilen® vs YSP Amoxicillin® capsule was between 0.80 and 1.25. Both Cmax and AUC met the predetermined criteria for assuming bioequivalence. Both formulations were well tolerated. The results showed significant inter-ethnicity variation in pharmacokinetics of amoxicillin. The Cmax and AUC of amoxicillin in Malay population were slightly lower compared with other populations.
    Matched MeSH terms: Therapeutic Equivalency
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links