METHODS: This was a cross-sectional observational study. From 2013 to 2014, we recruited inhabitants aged 50 years or older in Guangzhou, China. Among 1,117 participants in the study, data from 1,015 phakic right eyes were used for analyses. Ocular parameters including axial length (AL), anterior chamber depth (ACD), and corneal curvature (K) were measured using an IOL Master.
RESULTS: The mean AL, ACD, and K were 23.48 mm [95 % confidence interval (CI), 23.40-23.55], 3.03 mm (CI, 3.01-3.05), and 44.20 mm (CI, 44.11-44.29), respectively. A mean reduction in ACD with age was observed (P = 0.002) in male subjects but not in female subjects (P = 0.558). Male subjects had significantly longer ALs (23.68 mm versus 23.23 mm, P
METHODS: Sixty-six consecutive patients who had primary thyroid surgery were prospectively included in the present study between late January and early August 1998.
RESULTS: A total of 96 capsular dissections were performed at thyroid surgery. Grades two and three ZT were recognized in 77 (80.2%) dissections. In general 49 (63.6%) of them were associated with significant pressure symptoms. In 43 (87.8%) of the dissections with pressure symptoms, grade 3 ZT was observed (mean weight of goitre: 154.8 g). Interestingly in this group, 16 (37.2%) patients with pressure symptoms had a goitre that was < 100 g and in one patient it was only 21 g.
CONCLUSIONS: The pressure symptom of the thyroid gland does not always appear to be due to the large size of the goitre. In a relatively small-size goitre the ZT may cause significant pressure symptoms. Observations in the present study supported a strong association of enlarged ZT with pressure symptoms. We believe this is unlikely to be simply a coincidence but rather a consequence of the enlarged tubercle. Nonetheless a prospective randomized study is called for to allow meaningful and objective evidence to be drawn.
METHODS: Twenty-four studies met the inclusion criteria including 1761 cadaveric limbs.
RESULTS: The results were as following: (a) the mean palmaris longus tendon length was of 13.9 ± 2.6 cm, (b) the mean ratio palmaris longus tendon length/forearm length was of 0.545 ± 0.06, (c) the weighted correlation value was of 0.686, and (d) the mean palmaris longus tendon width was of 4.0 ± 1.7 mm. Only five studies reported a palmaris longus tendon length of more than 15 cm. The palmaris longus tendon length was shown to vary between ancestries; the Japanese had the shortest while Malaysian the longest palmaris longus tendons. All studies but one reported a palmaris longus tendon mean width of more than 3 mm where the minimal mean palmaris longus tendon width was of 2.5 mm.
CONCLUSION: While the requested length depends on the recipient site and/or type of reconstructive surgery, the palmaris longus tendon often met the required diameter for grafting. Our review demonstrated that while palmaris longus length varies between ancestries, its width is often adequate for grafting. In addition, the forearm length could be a good predictor of palmaris longus tendon length; such correlation could assist surgeons when planning to use palmaris longus tendon as a graft source.