Displaying publications 21 - 30 of 30 in total

Abstract:
Sort:
  1. Peh KK, Lim CP, Quek SS, Khoh KH
    Pharm Res, 2000 Nov;17(11):1384-8.
    PMID: 11205731
    PURPOSE: To use artificial neural networks for predicting dissolution profiles of matrix-controlled release theophylline pellet preparation, and to evaluate the network performance by comparing the predicted dissolution profiles with those obtained from physical experiments using similarity factor.

    METHODS: The Multi-Layered Perceptron (MLP) neural network was used to predict the dissolution profiles of theophylline pellets containing different ratios of microcrystalline cellulose (MCC) and glyceryl monostearate (GMS). The concepts of leave-one-out as well as a time-point by time-point estimation basis were used to predict the rate of drug release for each matrix ratio. All the data were used for training, except for one set which was selected to compare with the predicted output. The closeness between the predicted and the reference dissolution profiles was investigated using similarity factor (f2).

    RESULTS: The f2 values were all above 60, indicating that the predicted dissolution profiles were closely similar to the dissolution profiles obtained from physical experiments.

    CONCLUSION: The MLP network could be used as a model for predicting the dissolution profiles of matrix-controlled release theophylline pellet preparation in product development.

  2. Yuen KH, Peh KK, Billa N, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Feb;24(2):193-6.
    PMID: 15605452
    The bioavailability of a generic preparation of acyclovir (Avorax) was compared with the innovator product, Zovirax. Twelve healthy volunteers participated in the study, conducted according to a randomized, two-way crossover design. The preparations were compared using the parameters area under the plasma concentration time curve (AUC(0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the Tmax or the logarithmic transformed AUC(0-infinity) and C(max) values of the two preparations. In addition, the 90% confidence interval for the ratio of the logarithmic transformed AUC(0-infinity) values of Avorax over those of Zovirax was found to lie between 0.85 and 1.06, while that of the logarithmic transformed Cmax values was between 0.95 and 1.25, being within the bioequivalence limit of 0.80-1.25. Moreover, the elimination rate constant (k(e)), elimination half-life (t(1/2)), and apparent volume of distribution (Vd) values obtained with the two preparations were comparable and not significantly different statistically.
  3. Yuen KH, Wong JW, Peh KK, Julianto T, Choy WP
    Drug Dev Ind Pharm, 2000 Jul;26(7):803-7.
    PMID: 10872103
    The bioavailability of a generic preparation of pentoxifylline sustained-release (SR) tablet was evaluated in comparison with a proprietary product (Trental 400). For the study, 12 healthy male volunteers participated; the study was conducted according to a randomized, two-way crossover design. The bioavailability was compared using the parameters total area under the plasma level-time curve AUC0-infinity, peak plasma concentration Cmax, and time to reach peak plasma concentration Tmax. No statistically significant difference was observed between the values of the two products in all three parameters. The 90% confidence interval for the ratio of the logarithmic transformed AUC0-infinity values of the generic pentoxifylline over those of Trental 400 was found to lie between 0.83 and 1.00, while that of the parameter Cmax was between 0.91 and 1.29. In addition, elimination half-life t1/2 and apparent volume of distribution Vd were calculated. There was no statistically significant difference between the t1/2 Vd values obtained from the data of the two preparations.
  4. Peh KK, Yuen KH, Wong JW, Toh WT
    Drug Dev Ind Pharm, 1999 Mar;25(3):357-60.
    PMID: 10071830
    A study was conducted to compare the bioavailability of a generic product of atenolol (Normaten FC) with the innovator product, Tenormin. Twelve healthy adult volunteers participated in the study conducted according to a randomized, two-way crossover design. The preparations were compared using area under the plasma concentration-time curve AUC0-infinity, peak plasma concentration Cmax, and time to reach peak plasma concentration Tmax. No statistically significant difference was obtained between the Tmax values and the logarithmic transformed AUC0-infinity and Cmax values of the two products. Moreover, the 90% confidence interval for the ratio of the logarithmically transformed AUC0-infinity values of Normaten FC over those of Tenormin was found to lie between 0.82 and 0.98, while that of the logarithmically transformed Cmax values was between 0.82 and 1.09, both being within the bioequivalence limit of 0.80-1.25. The values of elimination half-life t1/2 between the two products were also found comparable and not significantly different statistically. The t1/2 values obtained in our study were slightly longer than those reported in the literature for other population groups.
  5. Yuen KH, Peh KK, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Oct;24(10):955-9.
    PMID: 9876550
    A study was conducted to compare the in vivo bioavailability of a generic metoprolol tablet preparation (Metoprolol) with that of the innovator product, Betaloc. Both preparations have a labeled dose of 100 mg metoprolol tartrate. Twelve healthy adult male volunteers participated in the study, which was conducted according to a standard two-way crossover design with a washout period of 1 week. The bioavailability was compared using the total area under the plasma level versus time curve (AUC0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the logarithmically transformed AUC0-infinity values or the logarithmically transformed Cmax values of the two preparations. However, a statistically significant difference was observed between the Tmax values, but may not be therapeutically significant or important. Moreover, the 90% confidence interval (CI) for the ratio of the logarithmically transformed AUC0-infinity values of Metoprolol over those of Betaloc was calculated to be between 0.94 and 1.02, while that of Cmax was between 0.98 and 1.01, both of which are within the acceptable limit of 0.80-1.25. From the data obtained, it was also observed that a high proportion of our volunteers of Asian origin appeared to be poor metabolizers of metoprolol, which was consistent with what had been observed in our previous study of another preparation of metoprolol.
  6. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
  7. Chow WP, Loganath A, Peh KL, Chew PC, Gunasegaram R, Ratnam SS
    Med J Malaysia, 1993 Mar;48(1):56-63.
    PMID: 8341173
    This study investigated whether changes in circulating levels of immunoreactive oestradiol-17 beta (E2), progesterone (P) and testosterone (T) occur in women at follicular (n = 18, age 25 to 39 years) and luteal (n = 17, 25 to 39 years) phases of the normal menstrual cycles, experiencing laparoscopy after intravenous sedation with general anaesthesia. The pre- and intra-operative follicular phase plasma steroid hormone concentrations were 153.5 +/- 84.3 vs 297.4 +/- 220.8 pg/ml for E2, 2.0 +/- 3.2 vs 3.3 +/- 3.8 ng/ml for P and 746.6 +/- 415.9 vs 1325.8 +/- 535.1 pg/ml for T, respectively. The corresponding luteal phase steroid levels were 259.7 +/- 120.2 vs 382.7 +/- 188.7 pg/ml, 7.0 +/- 4.8 vs 9.9 +/- 6.1 ng/ml and 819.4 +/- 355.7 vs 1703.5 +/- 1058.1 pg/ml. Using the Wilcoxon rank sum test, intra-operative hormone levels with the exception of P in the luteal phase were found to be significantly elevated (p < 0.05). The results suggest that laparoscopy under general anaesthesia evokes increased secretion of ovarian hormones, possibly via the activation of hypothalamo-pituitary-ovarian axis.
  8. Hassan Y, Alfadly SO, Azmin MN, Peh KK, Tan TF, Noorizan AA, et al.
    Singapore Med J, 2007 Sep;48(9):819-23.
    PMID: 17728962
    A bioequivalence study of two oral formulations of 500 mg tablets of ciprofloxacin (RAZA Pharmaniaga, Malaysia) as test and Ciprobay (Bayer AG, Germany) as reference, was carried out in 24 healthy human volunteers. Each volunteer received a single dose of ciprofloxacin.
  9. Ravi S, Peh KK, Darwis Y, Murthy BK, Singh TR, Mallikarjun C
    Indian J Pharm Sci, 2008 May-Jun;70(3):303-9.
    PMID: 20046737 DOI: 10.4103/0250-474X.42978
    The aim of the present work was to investigate the preparation of microspheres as potential drug carriers for proteins, intended for controlled release formulation. The hydrophilic bovine serum albumin was chosen as a model protein to be encapsulated within poly(D,L-lactide-co-glycolide) (50:50) microspheres using a w/o/w double emulsion solvent evaporation method. Different parameters influencing the particle size, entrapment efficiency and in vitro release profiles were investigated. The microspheres prepared with different molecular weight and hydrophilicity of poly(D,L-lactide-co-glycolide) polymers were non porous, smooth surfaced and spherical in structure under scanning electron microscope with a mean particle size ranging from 3.98 to 8.74 mum. The protein loading efficiency varied from 40 to 71% of the theoretical amount incorporated. The in vitro release profile of bovine serum albumin from microspheres presented two phases, initial burst release phase due to the protein adsorbed on the microsphere surface, followed by slower and continuous release phase corresponding to the protein entrapped in polymer matrix. The release rate was fairly constant after an initial burst release. Consequently, these microspheres can be proposed as new controlled release protein delivery system.
  10. Awi NJ, Yap HY, Armon S, Low JSH, Peh KB, Peh SC, et al.
    Malays J Pathol, 2021 Aug;43(2):269-279.
    PMID: 34448791
    Autophagy is a host defensive mechanism responsible for eliminating harmful cellular components through lysosomal degradation. Autophagy has been known to either promote or suppress various cancers including colorectal cancer (CRC). KRAS mutation serves as an important predictive marker for epidermal growth factor receptor (EGFR)-targeted therapies in CRC. However, the relationship between autophagy and KRAS mutation in CRC is not well-studied. In this single-centre study, 92 formalin-fixed paraffin-embedded (FFPE) tissues of CRC patients (42 Malaysian Chinese and 50 Indonesian) were collected and KRAS mutational status was determined by quantitative PCR (qPCR) (n=92) while the expression of autophagy effector (p62, LC3A and LC3B) was examined by immunohistochemistry (IHC) (n=48). The outcomes of each were then associated with the clinicopathological variables (n=48). Our findings demonstrated that the female CRC patients have a higher tendency in developing KRAS mutation in the Malaysian Chinese population (p<0.05). Expression of autophagy effector LC3A was highly associated with the tumour grade in CRC (p<0.001) but not with other clinicopathological parameters. Lastly, the survival analysis did not yield a statistically significant outcome. Overall, this small cohort study concluded that KRAS mutation and autophagy effectors are not good prognostic markers for CRC patients.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links