Displaying publications 21 - 33 of 33 in total

Abstract:
Sort:
  1. Abubakar BM, Salleh FM, Shamsir Omar MS, Wagiran A
    Pharm Biol, 2018 Dec;56(1):368-377.
    PMID: 30058427 DOI: 10.1080/13880209.2018.1479869
    CONTEXT: Eurycoma longifolia Jack (Simaroubaceae) commonly known as Tongkat Ali is one of the most important plants in Malaysia. The plant extracts (particularly roots) are widely used for the treatment of cough and fever besides having antimalarial, antidiabetic, anticancer and aphrodisiac activities.

    OBJECTIVES: This study assesses the extent of adulteration of E. longifolia herbal medicinal products (HMPs) using DNA barcoding validated by HPLC analysis.

    MATERIALS AND METHODS: Chloroplastic rbcL and nuclear ITS2 barcode regions were used in the present study. The sequences generated from E. longifolia HMPs were compared to sequences in the GenBank using MEGABLAST to verify their taxonomic identity. These results were verified by neighbor-joining tree analysis in which branches of unknown specimen are compared to the reference sequences established from this study and other retrieved from the GenBank. The HMPs were also analysed using HPLC analysis for the presence of eurycomanone bioactive marker.

    RESULTS: Identification using DNA barcoding revealed that 37% of the tested HMPs were authentic while 27% were adulterated with the ITS2 barcode region proven to be the ideal marker. The validation of the authenticity using HPLC analysis showed a situation in which a species which was identified as authentic was found not to contain the expected chemical compound.

    DISCUSSION AND CONCLUSIONS: DNA barcoding should be used as the first screening step for testing of HMPs raw materials. However, integration of DNA barcoding with HPLC analysis will help to provide detailed knowledge about the safety and efficacy of the HMPs.

    Matched MeSH terms: Drug Contamination*
  2. Juhlin K, Karimi G, Andér M, Camilli S, Dheda M, Har TS, et al.
    Drug Saf, 2015 Apr;38(4):373-82.
    PMID: 25687792 DOI: 10.1007/s40264-015-0271-2
    Substandard medicines, whether the result of intentional manipulation or lack of compliance with good manufacturing practice (GMP) or good distribution practice (GDP), pose a significant potential threat to patient safety. Spontaneous adverse drug reaction reporting systems can contribute to identification of quality problems that cause unwanted and/or harmful effects, and to identification of clusters of lack of efficacy. In 2011, the Uppsala Monitoring Centre (UMC) constructed a novel algorithm to identify reporting patterns suggestive of substandard medicines in spontaneous reporting, and applied it to VigiBase(®), the World Health Organization's global individual case safety report database. The algorithm identified some historical clusters related to substandard products, which were later able to be confirmed in the literature or by contact with national centres (NCs). As relevant and detailed information is often lacking in the VigiBase reports but might be available at the reporting NC, further evaluation of the algorithm was undertaken with involvement from NCs.
    Matched MeSH terms: Drug Contamination
  3. Lim VKE
    Med J Malaysia, 1995 Dec;50(4):289-90.
    PMID: 8668044
    Matched MeSH terms: Drug Contamination
  4. Mohd Yusop AY, Xiao L, Fu S
    Drug Test Anal, 2021 May;13(5):965-976.
    PMID: 32441056 DOI: 10.1002/dta.2861
    The lucrative market of herbal remedies spurs rampant adulteration, particularly with pharmaceutical drugs and their unapproved analogues. A comprehensive screening strategy is, therefore, warranted to detect these adulterants and, accordingly, to safeguard public health. This study uses the data-dependent acquisition of liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) to screen phosphodiesterase 5 (PDE5) inhibitors in herbal remedies using suspected-target and non-targeted strategies. For the suspected-target screening, we used a library comprising 95 PDE5 inhibitors. For the non-targeted screening, we adopted top-down and bottom-up approaches to flag novel PDE5 inhibitor analogues based on common fragmentation patterns. LC-QTOF-MS was optimised and validated for capsule and tablet dosage forms using 23 target analytes, selected to represent different groups of PDE5 inhibitors. The method exhibited excellent specificity and linearity with limit of detection and limit of quantification of <40 and 80 ng/mL, respectively. The accuracy ranged from 79.0% to 124.7% with a precision of <14.9% relative standard deviation. The modified, quick, easy, cheap, effective, rugged, and safe extraction provided insignificant matrix effect within -9.1%-8.0% and satisfactory extraction recovery of 71.5%-105.8%. These strategies were used to screen 52 herbal remedy samples that claimed to enhance male sexual performance. The suspected-target screening resulted in 33 positive samples, revealing 10 target analytes and 2 suspected analytes. Systematic MS and tandem MS interrogations using the non-targeted screening returned insignificant signals, indicating the absence of potentially novel analogues. The target analytes were quantified from 0.03 to 121.31 mg per dose of each sample. The proposed strategies ensure that all PDE5 inhibitors are comprehensively screened, providing a useful tool to curb the widespread adulteration of herbal remedies.
    Matched MeSH terms: Drug Contamination
  5. Roshaliza HM, Liu CY, Joanna OSM
    Med J Malaysia, 2011 Jun;66(2):92-4.
    PMID: 22106684
    This prospective study aimed to determine the extent of contamination of fentanyl solutions used for central neuraxial injection by wiping the neck of the ampoules with 70% isopropyl alcohol swabs (Kendall) before breaking open the ampoules and aspiration of fentanyl solutions using a 5 microm Filter Straw (B. Braun). In Group A, fifty fentanyl ampoules were wiped with 70% isopropyl alcohol swab prior to opening and the contents were aspirated immediately using a 21G needle and a 5 microm filter straw for culture. The same steps were repeated on the remaining solutions after two hours. In Group B, all the above steps were repeated but without wiping the ampoules with 70% isopropyl alcohol swabs. None of the samples from the wiped ampoules or aspiration using filter straw grew microorganisms. Six percent of the samples from unwiped group grew microorganisms when fentanyl were aspirated using a 21G needle and the contamination increased to 16% when repeated after two hours. Wiping the outsides of the fentanyl ampoules with 70% isopropyl alcohol swabs before opening or aspirating the contents using a 5 pm filter straw has been shown to be equally effective in avoiding bacterial contamination and should be practiced routinely when performing regional anaesthesia.
    KEY WORDS: Fentanyl solution, Isopropyl alcohol swab, Filter straw, Contamination, Regional anaesthesia, Hospital Kuala Lumpur, Malaysia
    Matched MeSH terms: Drug Contamination/prevention & control*
  6. Elbashir AA, Saad B, Ali AS, Saleh MI, Aboul-Enein HY
    Biomed Chromatogr, 2009 May;23(5):464-71.
    PMID: 19016231 DOI: 10.1002/bmc.1137
    A capillary zone electrophoretic method has been developed and validated for the determination of the impurity quinocide (QC) in the antimalarial drug primaquine (PQ). Different buffer additives such as native cyclodextrins and crown ethers were evaluated. Promising results were obtained when either beta-cyclodextrin (beta-CD) or 18-crown-6 ether (18C6) were used. Their separation conditions such as type of buffer and its pH, buffer additive concentration, applied voltage capillary temperature and injection time were optimized. The use of 18C6 offers slight advantages over beta-CD such as faster elution times and improved resolution. Nevertheless, migration times of less than 5 min and resolution factors (R(s)) in the range of 2-4 were obtained when both additives were used. The method was validated with respect to selectivity, linearity, limits of detection and quantitation, analytical precision (intra- and inter-day variability) and repeatability. Concentrations of 2.12 and 2.71% (w/w) of QC were found in pharmaceutical preparations of PQ from two different manufacturers. A possible mechanism for the successful separation of the isomers is also discussed.
    Matched MeSH terms: Drug Contamination*
  7. Ang HH, Lee KL
    Int J Toxicol, 2007 Sep-Oct;26(5):433-9.
    PMID: 17963130 DOI: 10.1080/10915810701583036
    The DCA (Drug Control Authority) of Malaysia implemented phase 3 registration of traditional medicines in January 1992 with special emphasis on the quality, efficacy, and safety of all dosage forms of these medicines. For this reason, a total of 100 herbal products containing Smilax myosotiflora were purchased in the Malaysian market and analyzed for mercury content, as mercury is a recognized reproductive toxicant. The products were analyzed using cold vapor atomic absorption spectrophotometry. It was found that 89% of the above products do not exceed 0.5 ppm of mercury. Heavy metal poisoning such as mercury has been associated with traditional medicines. Therefore, it is important that doctors and health care practitioners are aware of these risks and finding ways to minimize them, including questions pertaining to the use of these remedies during the routine taking of a patient's history.
    Matched MeSH terms: Drug Contamination/prevention & control*
  8. A VBR, Yusop Z, Jaafar J, Aris AB, Majid ZA, Umar K, et al.
    J Pharm Biomed Anal, 2016 Sep 05;128:141-148.
    PMID: 27262107 DOI: 10.1016/j.jpba.2016.05.026
    In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis.
    Matched MeSH terms: Drug Contamination
  9. Mokhtar SU, Chin ST, Kee CL, Low MY, Drummer OH, Marriott PJ
    J Pharm Biomed Anal, 2016 Mar 20;121:188-196.
    PMID: 26808068 DOI: 10.1016/j.jpba.2016.01.034
    Application of gas chromatography-triple quadrupole mass spectrometry for identification, confirmation and quantification of 6 phosphodiesterase-5 (PDE-5) inhibitors (sildenafil, dimethylsildenafil, homosildenafil, thiosildenafil, thiodimethylsildenafil and thiohomosildenafil) in dietary supplements was investigated. The MS was operated in multiple reaction monitoring mode, for better sensitivity and selectivity. In this manner, the method is adequate to reduce background noise with less interference from co-eluting compounds in the samples. Two different ionisation techniques, electron ionisation (EI) and chemical ionisation (CI), were studied and compared. The chromatographic separation was performed on a short 10 m non-polar capillary column without any derivatisation step. This permitted fast analysis for all analogues with retention time less than 11 min, for both techniques. Use of backflushing can aid method retention time reduction and improves column maintenance. Evaluation of method validation included limit of detection (LOD), lower limit of quantitation (LLOQ), linearity, precision and recovery were performed for both EI and CI techniques. The LOD obtained varied from 0.03 to 1.50 μg/g and the LLOQ ranged from 0.10 to 5.00 μg/g. Good calibration linearity was obtained for all analogues for both techniques, with correlation coefficients (r(2)) higher than 0.99. Mean recoveries of all analogues using CI show higher values (83.4-108.8%) than that of EI (61.9-91.1%). The intra- and inter-assay precisions were evaluated for all analogues at spiked concentration of 10 μg/g and the relative standard deviation was less than 15% for both methods. These methods were then successfully applied to dietary supplement samples without prior derivatisation, confirming that the samples were adulterated with sildenafil and/or its analogues.
    Matched MeSH terms: Drug Contamination
  10. Mohd Yusop AY, Xiao L, Fu S
    Drug Test Anal, 2021 May;13(5):953-964.
    PMID: 32959983 DOI: 10.1002/dta.2926
    The surge in the consumption of food products containing herbal aphrodisiacs has driven their widespread adulteration. A rapid screening strategy is, therefore, warranted to curb this problem. This study established an enzyme inhibition assay to screen phosphodiesterase 5 (PDE5) inhibitors as adulterants in selected food products. Fluorescein-labelled cyclic-3',5'-guanosine monophosphate was utilised as substrates for the PDE5A1 enzyme, aided by the presence of nanoparticle phosphate-binding beads on their fluorescence polarisation. The sample preparation was optimised to improve the enzyme inhibition efficiency and applied to calculate the threshold values of six blank food matrices. The assay was validated using sildenafil, producing an IC50 of 4.2 nM. The applicability of the assay procedure was demonstrated by screening 55 distinct food samples. The results were subsequently verified using confirmatory liquid chromatography-high-resolution mass spectrometry (LC-HRMS) analysis. Altogether, 49 samples inhibited the PDE5 enzyme above the threshold values (75.7%-105.5%) and were registered as potentially adulterated samples. The remaining six samples were marked as nonadulterated with percentage inhibition below the threshold values (-3.3%-18.2%). The LC-HRMS analysis agreed with the assay results for all food products except for the instant coffee premix (ICP) samples. False-positive results were obtained for the ICP samples at 32% (8/25), due to possible PDE5 inhibition by caffeine. Contrarily, all other food samples were found to produce 0% (0/30) false-positive or false-negative results. The broad-based assay, established via a simple mix-incubate-read format, exhibited promising potential for high-throughput screening of PDE5 inhibitors in various food products, except those with naturally occurring phosphodiesterase inhibitors such as caffeine.
    Matched MeSH terms: Drug Contamination
  11. Chin SP, Poey AC, Wong CY, Chang SK, Teh W, Mohr TJ, et al.
    Cytotherapy, 2010;12(1):31-7.
    PMID: 19878080 DOI: 10.3109/14653240903313966
    Bone marrow (BM) mesenchymal stromal cells (MSC) represent a novel therapy for severe heart failure with extensive myocardial scarring, especially when performed concurrently with conventional revascularization. However, stem cells are difficult to transport in culture media without risk of contamination, infection and reduced viability. We tested the feasibility and safety of off-site MSC culture and expansion with freeze-controlled cryopreservation and subsequent rapid thawing of cells immediately prior to implantation to treat severe dilated ischemic cardiomyopathy.
    Matched MeSH terms: Drug Contamination/prevention & control
  12. Van Rostenberghe H, Noraida R, Wan Pauzi WI, Habsah H, Zeehaida M, Rosliza AR, et al.
    Jpn J Infect Dis, 2006 Apr;59(2):120-1.
    PMID: 16632913
    Pantoea infections are uncommon in humans. Most reports have involved adults or children after thorn injuries. There are only a few reports of systemic infections with Pantoea. This is the first report of the clinical picture of systemic Pantoea spp. infection in neonates as observed during an outbreak in a neonatal intensive care unit caused by infected parenteral nutrition solutions. Even though detected early, the infections had a fulminant course, causing septicemic shock and respiratory failure. Pulmonary disease was prominent and presented mainly as pulmonary hemorrhage and adult respiratory distress syndrome. The organism was sensitive to most antibiotics used in neonatal intensive care units, but the clinical response to antibiotic therapy was poor. The fatality rate was very high: 7 out of 8 infected infants succumbed to the infection (87.5%).
    Matched MeSH terms: Drug Contamination*
  13. Habsah H, Zeehaida M, Van Rostenberghe H, Noraida R, Wan Pauzi WI, Fatimah I, et al.
    J Hosp Infect, 2005 Nov;61(3):213-8.
    PMID: 16213372
    Contaminated parenteral nutrition (PN) is an important source of infection in neonates. Many organisms have been reported to cause contamination that results in outbreaks in intensive care units. The objective of this study was to investigate an outbreak caused by Pantoea spp., which contaminates PN, in a neonatal intensive care unit (NICU). This was a descriptive study of an outbreak of sepsis in an NICU of a tertiary teaching hospital in Malaysia. Pantoea spp. infection was detected in eight patients over a three-day period from 24 to 27 January 2004 following the administration of PN. Seven of the eight patients died due to the infection. Extensive environmental samplings for culture were performed. PN solution from the NICU and the pharmacy were also cultured during the outbreak period. Pantoea spp. was isolated from blood cultures of all infected patients, and the unused PN from the pharmacy and the NICU. All the strains of Pantoea spp. had a similar antibiotic susceptibility pattern and biochemical reaction. From the results, we concluded that PN was the source of the outbreak and the contamination may have occurred during its preparation in the pharmacy. A thorough investigation has been carried out and, where possible, corrective measures have been taken to avoid similar outbreaks in the future.
    Matched MeSH terms: Drug Contamination
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links