Displaying publications 21 - 25 of 25 in total

Abstract:
Sort:
  1. Ong BL
    Sains Malaysiana, 1996;25(3):13-18.
    A retrospective study of the incidence of Giant Papillary Conjunctivitis (GPC) seen in the Optometry clinic in Universiti Kebangsaan Malaysia from 1989 to 1994 was carried out. In the period of the 6 years, 37 contact wearers were diagnosed to have GPC. Of the 37 patients, 21 were Malays (57%), 12 were Chinese (32%) and the remaining 4 patients were Indians (11%). 18 or 48% of those with GPC were soft lens wearers, 46% of the wearers (17 patients) were rigid gas permeable lens wearers and 1 of the patients seen was a hard (PMMA) wearer (3%) and the other one was a disposable lens wearer (3%). Thirty patients were female (81%) and 7 (19%) were male. The age range of those with GPC were between 9 to 60 years old.
    Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
    Matched MeSH terms: Optometry
  2. Hairol MI, Arif N, Mohd Shariffudin SH
    Jurnal Sains Kesihatan Malaysia, 2018;16(1):103-108.
    MyJurnal
    Patient’s appointment compliance refers to the willingness and ability of a patient to attend to their scheduled clinical appointment. Failure to do so have various consequences, especially so for a teaching clinic such as the Optometry Clinic, Universiti Kebangsaan Malaysia (UKM). The percentage of appoinment compliance at the Optometry Clinic was analysed from September to December 2015. Compliance rate was categorised based on clinic type and session, and on patient’s gender and ethnicity. Attendance compliance was around 60% for the Primary Care Clinic. It increased to 70% for patients with vision problems who where referred to specialty clinics i.e. Low Vision and Paediatric Clinics. Clinic day and session did not influence compliance significanly (p > 0.05). Patient’s gender and ethnicity did not influence compliance significantly as well but those of Indian ethnicity consistently showed the lowest appointment compliance rates. A protocol should be developed to increase the rate of patients’ appoinment compliance. This would then maximise productivity of students and clinic staff and optimise the clinic’s resources. The cost of each clinical session could be informed to the patients, even when the cost is not borne by them.
    Keywords: Appointment compliance; Optometry Clinic; appointments; clinical teaching and learning; public health
    Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
    Matched MeSH terms: Optometry
  3. Graham JE, McGilligan VE, Berrar D, Leccisotti A, Moore JE, Bron AJ, et al.
    Ophthalmic Res, 2010;43(1):11-7.
    PMID: 19829007 DOI: 10.1159/000246573
    AIM: The purpose of this study was to survey the attitudes of optometrists and ophthalmologists, located in a number of different countries, towards diagnostic tests and therapies for dry eye disease.
    METHODS: A web-based questionnaire was used to survey attitudes using forced-choice questions and Likert scales.
    RESULTS: Sixty-one respondents (23 ophthalmologists and 38 optometrists) reported a wide range of patient dry eye symptoms. A large variation in use of diagnostic tests was noted. Patient symptoms and fluorescein staining were reported to be significantly more valuable and more frequently performed than any other test. Artificial tear supplements and improved lid hygiene were the preferred therapeutic options selected by the entire group. The results demonstrated a wide variation in attitudes in relation to satisfaction with the range of available diagnostic and therapeutic options.
    CONCLUSIONS: This study indicates that the interest for the issue of dry eye is relatively limited amongst eye professionals, as demonstrated by the poor participation in the questionnaire.
    Matched MeSH terms: Optometry
  4. Sharanjeet-Kaur, Mursyid A, Kamaruddin A, Ariffin A
    Clin Exp Optom, 2004 Jul;87(4-5):339-43.
    PMID: 15312037 DOI: 10.1111/j.1444-0938.2004.tb05064.x
    BACKGROUND: Occupational exposure to various neurotoxic chemicals has been shown to be associated with colour vision impairment. It seems that this can occur at low exposure levels, sometimes well below the recommended occupational threshold limits. This study was undertaken to determine the effect of exposure to petroleum derivatives (polyethylene, polystyrene) and solvents (perchloroethylene) on colour perception.
    METHODS: Colour vision was assessed using the Ishihara plates, the D-15 test and the Farnsworth Munsell 100 Hue test. Two factories using petroleum derivatives and three dry cleaning premises were chosen at random. A total of 93 apparently healthy employees were recruited from the five workplaces. Two age-matched control groups comprising 56 people, who were support staff of the university with no exposure to petroleum, solvents or their derivatives, were also recruited.
    RESULTS: All subjects passed the Ishihara test, showing that none had a congenital red-green defect. Some of the exposed employees failed the D-15 and had abnormally high FM100 Hue scores. All control subjects passed all the colour vision tests. The D-15 test showed that 28 per cent (26 of 93) of exposed employees had a colour vision defect whereas the FM 100 Hue test found that 63 per cent (59 of 93) had a colour vision defect. Most defects were of the blue-yellow type (22.6 per cent) when using the D-15 test. However, with the FM 100 Hue test, most defects were of the non-polar type with no specific axis (50.5 per cent). Mean total error scores calculated from the FM100 Hue test for exposed employees were statistically significantly higher than those of the control subjects.
    CONCLUSION: Employees directly exposed to petroleum derivatives and solvents have a higher risk of acquiring colour vision defects compared to subjects who are not.
    Study sites: Factories; the control subjects were tested at the Optometry Clinic in Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
    Matched MeSH terms: Optometry
  5. Cheah PS, Mohidin N, Mohd Ali B, Maung M, Latif AA
    Malays J Med Sci, 2008 Jul;15(3):49-54.
    PMID: 22570589
    This study illustrates and quantifies the changes on corneal tissue between the paraffin-embedded and resin-embedded blocks and thus, selects a better target in investigational ophthalmology and optometry via light microscopy. Corneas of two cynomolgus monkeys (Macaca fascicularis) were used in this study. The formalin-fixed cornea was prepared in paraffin block via the conventional tissue processing protocol (4-day protocol) and stained with haematoxylin and eosin. The glutaraldehyde-fixed cornea was prepared in resin block via the rapid and modified tissue processing procedure (1.2-day protocol) and stained with toluidine blue. The paraffin-embedded sample exhibits various undesired tissue damage and artifact such as thinner epithelium (due to the substantial volumic extraction from the tissue), thicker stroma layer (due to the separation of lamellae and the presence of voids) and the distorted endothelium. In contrast, the resin-embedded corneal tissue has demonstrated satisfactory corneal ultrastructural preservation. The rapid and modified tissue processing method for preparing the resin-embedded is particularly beneficial to accelerate the microscopic evaluation in ophthalmology and optometry.
    Matched MeSH terms: Optometry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links