Displaying publications 21 - 40 of 1043 in total

Abstract:
Sort:
  1. Engku Nur Syafirah EAR, Nurul Najian AB, Foo PC, Mohd Ali MR, Mohamed M, Yean CY
    Acta Trop, 2018 Jun;182:223-231.
    PMID: 29545156 DOI: 10.1016/j.actatropica.2018.03.004
    Cholera, caused by Vibrio cholerae is a foodborne disease that frequently reported in food and water related outbreak. Rapid diagnosis of cholera infection is important to avoid potential spread of disease. Among available diagnostic platforms, loop-mediated isothermal amplification (LAMP) is regarded as a potential diagnostic tool due to its rapidity, high sensitivity and specificity and independent of sophisticated thermalcycler. However, the current LAMP often requires multiple pipetting steps, hence is susceptible to cross contamination. Besides, the strict requirement of cold-chain during transportation and storage make its application in low resource settings to be inconvenient. To overcome these problems, the present study is aimed to develop an ambient-temperature-stable and ready-to-use LAMP assay for the detection of toxigenic Vibrio cholerae in low resource settings. A set of specific LAMP primers were designed and tested against 155 V. cholerae and non-V. cholerae strains. Analytical specifity showed that the developed LAMP assay detected 100% of pathogenic V. cholerae and did not amplified other tested bacterial strains. Upon testing against stool samples spiked with toxigenic V. cholerae outbreak isolates, the LAMP assay detected all of the spiked samples (n = 76/76, 100%), in contrast to the conventional PCR which amplified 77.6% (n = 59/76) of the tested specimens. In term of sensitivity, the LAMP assay was 100-fold more sensitive as compared to the conventional PCR method, with LOD of 10 fg per μL and 10 CFU per mL. Following lyophilisation with addition of lyoprotectants, the dry-reagent LAMP mix has an estimated shelf-life of 90.75 days at room temperature.
    Matched MeSH terms: Sensitivity and Specificity
  2. Lai MY, Ponnampalavanar SSS, Omar SFS, Lau YL
    Acta Trop, 2024 Mar;251:107120.
    PMID: 38199452 DOI: 10.1016/j.actatropica.2024.107120
    Combining the advantages of PCR and LAMP, we described a new technique, namely PCR-LAMP, for malaria diagnosis. The whole process of DNA amplification can be completed in 35 min. This hybrid amplification technique markedly improved the sensitivity of detection compared to the classic single PCR or LAMP assay alone. PCR-LAMP assay had a detection limit of 1 copy/µL for P. knowlesi and P. ovale, 0.1 copy/µL for P. vivax, P. falciparum and P. malariae, respectively. To facilitate the endpoint detection, xylenol orange was added. Positive samples were indicated in orange while negative reactions were violet. The inclusion of xylenol orange into the LAMP reaction mix significantly reduces the post-amplification workload. Without relying on the use of specific instruments, the color changes of the amplicons could be visualized directly through the naked eye. In conclusion, PCR-LAMP poses the potential to be developed as a new malaria molecular diagnosis tool.
    Matched MeSH terms: Sensitivity and Specificity
  3. Loh HS, Mohd-Azmi ML
    Acta Virol., 2009;53(4):261-9.
    PMID: 19941390
    One-step real-time RT-PCR assay was developed for quantification of the immediate-early (IE), namely IE1 and IE2 transcripts of Rat cytomegalovirus (RCMV), strain ALL-03 in rat embryonic fibroblast cells (REF). This in-house SYBR Green I based RT-PCR was shown to have higher amplification efficiency and detection limit as compared to a commercially available real-time RT-PCR kit in quantifying these two transcripts. The quantification histogram revealed the divergence of transcription activities of the two IE genes. The IE1 transcript had a concentration peak at 7 hrs post infection (p.i.), whereas IE2 transcript at 20 hrs p.i. Regulation of IE expression is critical for determination, whether the infection is going to be abortive, lytic or latent. Therefore, this in-house developed quantitative RT-PCR assay offers an alternative for diagnosis and monitoring of the acute cytomegalovirus (CMV) infection directed at IE transcript detection.
    Matched MeSH terms: Sensitivity and Specificity
  4. Tan SW, Omar AR, Aini I, Yusoff K, Tan WS
    Acta Virol., 2004;48(1):23-8.
    PMID: 15230471
    A two-step SYBR Green I real time polymerase chain reaction (PCR, real time PCR) for the detection of Newcastle disease virus (NDV) was developed. A melting curve analysis was performed to distinguish specific from non-specific products and primer dimers. Regardless of different virus pathotypes the melting temperature (Tm) ranged from 86 degrees C to 87 degrees C. The sensitivity of the real time PCR was compared with the reverse transcription (RT)-nested PCR enzyme-linked immunosorbent assay (ELISA, RT-nested PCR ELISA). Whereas the detection limit of the real time PCR was 10 pg DNA, the RT-nested PCR ELISA and conventional PCR could only detect up to 1 ng and 10 ng DNA, respectively. Thus the real time PCR offers a sensitive, rapid and convenient method for screening large number of NDV specimens.
    Matched MeSH terms: Sensitivity and Specificity
  5. Choi JR, Yong KW, Tang R, Gong Y, Wen T, Yang H, et al.
    Adv Healthc Mater, 2017 Jan;6(1).
    PMID: 27860384 DOI: 10.1002/adhm.201600920
    Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications.
    Matched MeSH terms: Sensitivity and Specificity
  6. Ogunfowokan O, Ogunfowokan BA, Nwajei AI
    Afr J Prim Health Care Fam Med, 2020 Jun 17;12(1):e1-e8.
    PMID: 32634015 DOI: 10.4102/phcfm.v12i1.2212
    BACKGROUND: Malaria diagnosis using microscopy is currently the gold standard. However, malaria rapid diagnostic tests (mRDTs) were developed to simplify the diagnosis in regions without access to functional microscopy.

    AIM: The objective of this study was to compare the diagnostic accuracy of mRDT CareStatTM with microscopy.

    SETTING: This study was conducted in the paediatric primary care clinic of the Federal Medical Centre, Asaba, Nigeria.

    METHODS: A cross-sectional study for diagnostic accuracy was conducted from May 2016 to October 2016. Ninety-eight participants were involved to obtain a precision of 5%, sensitivity of mRDT CareStatTM of 95% from published work and 95% level of confidence after adjusting for 20% non-response rate or missing data. Consecutive participants were tested using both microscopy and mRDT. The results were analysed using EPI Info Version 7.

    RESULTS: A total of 98 children aged 3-59 months were enrolled. Malaria prevalence was found to be 53% (95% confidence interval [CI] = 46% - 60%), whilst sensitivity and specificity were 29% (95% CI = 20% - 38%) and 89% (95% CI = 83% - 95%), respectively. The positive and negative predictive values were 75% (95% CI = 66.4% - 83.6%) and 53% (95% CI = 46% - 60%), respectively.

    CONCLUSION: Agreement between malaria parasitaemia using microscopy and mRDT positivity increased with increase in the parasite density. The mRDT might be negative when malaria parasite density using microscopy is low.

    Matched MeSH terms: Sensitivity and Specificity
  7. Karlas T, Petroff D, Sasso M, Fan JG, Mi YQ, de Lédinghen V, et al.
    Aliment Pharmacol Ther, 2018 Apr;47(7):989-1000.
    PMID: 29446106 DOI: 10.1111/apt.14529
    BACKGROUND: Liver fibrosis is often accompanied by steatosis, particularly in patients with non-alcoholic fatty liver disease (NAFLD), and its non-invasive characterisation is of utmost importance. Vibration-controlled transient elastography is the non-invasive method of choice; however, recent research suggests that steatosis may influence its diagnostic performance. Controlled Attenuation Parameter (CAP) added to transient elastography enables simultaneous assessment of steatosis and fibrosis.

    AIM: To determine how to use CAP in interpreting liver stiffness measurements.

    METHODS: This is a secondary analysis of data from an individual patient data meta-analysis on CAP. The main exclusion criteria for the current analysis were unknown aetiology, unreliable elastography measurement and data already used for the same research question. Aetiology-specific liver stiffness measurement cut-offs were determined and used to estimate positive and negative predictive values (PPV/NPV) with logistic regression as functions of CAP.

    RESULTS: Two thousand and fifty eight patients fulfilled the inclusion criteria (37% women, 18% NAFLD/NASH, 42% HBV, 40% HCV, 51% significant fibrosis ≥ F2). Youden optimised cut-offs were only sufficient for ruling out cirrhosis (NPV of 98%). With sensitivity and specificity-optimised cut-offs, NPV for ruling out significant fibrosis was moderate (70%) and could be improved slightly through consideration of CAP. PPV for significant fibrosis and cirrhosis were 68% and 55% respectively, despite specificity-optimised cut-offs for cirrhosis.

    CONCLUSIONS: Liver stiffness measurement values below aetiology-specific cut-offs are very useful for ruling out cirrhosis, and to a lesser extent for ruling out significant fibrosis. In the case of the latter, Controlled Attenuation Parameter can improve interpretation slightly. Even if cut-offs are very high, liver stiffness measurements are not very reliable for ruling in fibrosis or cirrhosis.

    Matched MeSH terms: Sensitivity and Specificity
  8. Leecyous B, Bakhtiar F, Tang MM, Yadzir ZHM, Abdullah N
    Allergol Immunopathol (Madr), 2020 06 09;48(6):626-632.
    PMID: 32532468 DOI: 10.1016/j.aller.2020.01.006
    INTRODUCTION: Basophil activation test (BAT) and immunoassays are the most widely used in vitro tests to diagnose IgE-mediated allergic reactions to penicillin. However, studies to determine if one test is interdependent from another are limited.

    OBJECTIVE: The present study aimed to measure the agreement between BAT and immunoassay in diagnosis of penicillin allergy.

    METHOD: BAT was performed using penicillin G (Pen G), penicillin V (Pen V), penicilloyl-polylysine (PPL), minor determinant mix (MDM), amoxicillin (Amx) and ampicillin (Amp) in 25 patients. Immunoassay of total IgE (tIgE) and specific IgE (sIgE) antibodies to Pen G, Pen V, Amx and Amp were quantified. Skin prick test (SPT) using PPL-MDM, Amx, Amp and Clavulanic acid were also performed.

    RESULTS: Minimal agreement was observed between BAT and immunoassay (k=0.25). Of two BAT-positive patients, one patient is positive to Amx (59.27%, SI=59) and Amp (82.32%, SI=82) but sIgE-negative to all drug tested. This patient is also SPT-positive to both drugs. Another patient is BAT-positive to Pen G (10.18%, SI=40), Pen V (25.07%, SI=100) and Amp (19.52%, SI=79). In sIgE immunoassay, four patients were sIgE-positive to at least one of the drugs tested. The sIgE level of three patients was between low and moderate and they were BAT-negative. One BAT-positive patient had a high level of sIgE antibodies (3.50-17.5kU/L) along with relatively high specific to total IgE ratio ≥0.002 (0.004-0.007).

    CONCLUSIONS: The agreement between BAT and immunoassay is minimal. Performing both tests provides little increase in the sensitivity of allergy diagnosis work-up for immediate reactions to penicillin.

    Matched MeSH terms: Sensitivity and Specificity
  9. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, et al.
    Am Heart J, 2006 Jun;151(6):1323.e1-6.
    PMID: 16781246
    The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
    Matched MeSH terms: Sensitivity and Specificity
  10. Bawadikji AA, Teh CH, Sheikh Abdul Kader MAB, Abdul Wahab MJB, Syed Sulaiman SA, Ibrahim B
    Am J Cardiovasc Drugs, 2020 Apr;20(2):169-177.
    PMID: 31435902 DOI: 10.1007/s40256-019-00364-2
    BACKGROUND: Warfarin is prescribed as an oral anticoagulant to treat/prevent thromboembolism in conditions such as atrial fibrillation. As there is a narrow therapeutic window, treatment with warfarin is challenging. Pharmacometabonomics using nuclear magnetic resonance (NMR) spectroscopy may provide novel techniques for the identification of novel biomarkers of warfarin.

    PURPOSE: The aim was to determine the metabolic fingerprint that predicts warfarin response based on the international normalized ratio (INR) in patients who are already receiving warfarin (phase I: identification) and to ascertain the metabolic fingerprint that discriminates stable from unstable INR in patients starting treatment with warfarin (phase II: validation).

    EXPERIMENTAL APPROACH: A total of 94 blood samples were collected for phase I: 44 patients with stable INR and 50 with unstable INR. Meanwhile, 23 samples were collected for phase II: nine patients with stable INR and 14 with unstable INR. Data analysis was performed using multivariate analysis including principal component analysis and partial least square-discriminate analysis (PLS-DA), followed by univariate and multivariate logistic regression (MVLR) to develop a model to identify unstable INR biomarkers.

    KEY RESULTS: For phase I, the PLS-DA model showed the following results: sensitivity 93.18%, specificity 91.49% and accuracy 92.31%. In the MVLR analysis of phase I, ten regions were associated with unstable INR. For phase II, the PLS-DA model showed the following results: sensitivity 66.67%, specificity 61.54% and accuracy 63.64%.

    CONCLUSIONS AND IMPLICATIONS: We have shown that the pharmacometabonomics technique was able to differentiate between unstable and stable INR with good accuracy. NMR-based pharmacometabonomics has the potential to identify novel biomarkers in plasma, which can be useful in individualizing treatment and controlling warfarin side effects, thus, minimizing undesirable effects in the future.

    Matched MeSH terms: Sensitivity and Specificity
  11. Kruszka P, Porras AR, de Souza DH, Moresco A, Huckstadt V, Gill AD, et al.
    Am J Med Genet A, 2018 05;176(5):1128-1136.
    PMID: 29681090 DOI: 10.1002/ajmg.a.38672
    Williams-Beuren syndrome (WBS) is a common microdeletion syndrome characterized by a 1.5Mb deletion in 7q11.23. The phenotype of WBS has been well described in populations of European descent with not as much attention given to other ethnicities. In this study, individuals with WBS from diverse populations were assessed clinically and by facial analysis technology. Clinical data and images from 137 individuals with WBS were found in 19 countries with an average age of 11 years and female gender of 45%. The most common clinical phenotype elements were periorbital fullness and intellectual disability which were present in greater than 90% of our cohort. Additionally, 75% or greater of all individuals with WBS had malar flattening, long philtrum, wide mouth, and small jaw. Using facial analysis technology, we compared 286 Asian, African, Caucasian, and Latin American individuals with WBS with 286 gender and age matched controls and found that the accuracy to discriminate between WBS and controls was 0.90 when the entire cohort was evaluated concurrently. The test accuracy of the facial recognition technology increased significantly when the cohort was analyzed by specific ethnic population (P-value 
    Matched MeSH terms: Sensitivity and Specificity
  12. Kruszka P, Porras AR, Sobering AK, Ikolo FA, La Qua S, Shotelersuk V, et al.
    Am J Med Genet A, 2017 Jan;173(1):42-53.
    PMID: 27991738 DOI: 10.1002/ajmg.a.38043
    Down syndrome is the most common cause of cognitive impairment and presents clinically with universally recognizable signs and symptoms. In this study, we focus on exam findings and digital facial analysis technology in individuals with Down syndrome in diverse populations. Photos and clinical information were collected on 65 individuals from 13 countries, 56.9% were male and the average age was 6.6 years (range 1 month to 26 years; SD = 6.6 years). Subjective findings showed that clinical features were different across ethnicities (Africans, Asians, and Latin Americans), including brachycephaly, ear anomalies, clinodactyly, sandal gap, and abundant neck skin, which were all significantly less frequent in Africans (P 
    Matched MeSH terms: Sensitivity and Specificity
  13. Wang Y, Cheng C, Zhang Z, Wang J, Wang Y, Li X, et al.
    Am J Med Genet B Neuropsychiatr Genet, 2018 12;177(8):709-716.
    PMID: 30350918 DOI: 10.1002/ajmg.b.32675
    No biologically based diagnostic criteria are in clinical use today for obsessive-compulsive disorder (OCD), schizophrenia, and major depressive disorder (MDD), which are defined with reference to Diagnostic and Statistical Manual clinical symptoms alone. However, these disorders cannot always be well distinguished on clinical grounds and may also be comorbid. A biological blood-based dynamic genomic signature that can differentiate among OCD, MDD, and schizophrenia would therefore be of great utility. This study enrolled 77 patients with OCD, 67 controls with no psychiatric illness, 39 patients with MDD, and 40 with schizophrenia. An OCD-specific gene signature was identified using blood gene expression analysis to construct a predictive model of OCD that can differentiate this disorder from healthy controls, MDD, and schizophrenia using a logistic regression algorithm. To verify that the genes selected were not derived as a result of chance, the algorithm was tested twice. First, the algorithm was used to predict the cohort with true disease/control status and second, the algorithm predicted the cohort with disease/control status randomly reassigned (null set). A six-gene panel (COPS7A, FKBP1A, FIBP, TP73-AS1, SDF4, and GOLGA8A) discriminated patients with OCD from healthy controls, MDD, and schizophrenia in the training set (with an area under the receiver-operating-characteristic curve of 0.938; accuracy, 86%; sensitivity, 88%; and specificity, 85%). Our findings indicate that a blood transcriptomic signature can distinguish OCD from healthy controls, MDD, and schizophrenia. This finding further confirms the feasibility of using dynamic blood-based genomic signatures in psychiatric disorders and may provide a useful tool for clinical staff engaged in OCD diagnosis and decision making.
    Matched MeSH terms: Sensitivity and Specificity
  14. Choong YF, Chen AH, Goh PP
    Am J Ophthalmol, 2006 Jul;142(1):68-74.
    PMID: 16815252 DOI: 10.1016/j.ajo.2006.01.084
    To evaluate the accuracy of autorefraction using three autorefractors comparing to subjective refraction in diagnosing refractive error in children.
    Matched MeSH terms: Sensitivity and Specificity
  15. Surendran S, Thomas E
    Am J Orthod Dentofacial Orthop, 2014 Jan;145(1):7-14.
    PMID: 24373650 DOI: 10.1016/j.ajodo.2013.09.007
    The objective of this study was to determine whether dental calcification can be used as a first-level diagnostic tool for assessment of skeletal maturity.
    Matched MeSH terms: Sensitivity and Specificity
  16. Abdulamir AS, Hafidh RR, Abu Bakar F, Abbas K
    Am J Otolaryngol, 2010 Nov-Dec;31(6):410-7.
    PMID: 20015794 DOI: 10.1016/j.amjoto.2009.06.006
    PURPOSE: This study was designed to find a reliable Epstein-Barr virus (EBV) immunoglobulin (Ig) G-based diagnostic/screening test for nasopharyngeal carcinoma (NPC) able to demarcate between the NPC-related seropositivity of EBV IgG antibodies and that of other head and neck cancer (HNCA) and control groups. The NPC-associated immunosuppression affects EBV IgA much more than IgG, leading to inconsistent detection of NPC using EBV IgA antibodies.
    MATERIALS AND METHODS: One hundred twenty-two HNCA patients, 42 NPC, 66 laryngeal carcinoma, and 14 hypopharyngeal carcinoma and 3 groups of 100 control subjects were enrolled in this study. Enzyme-linked immunosorbent assay (ELISA) was used to find a specific cutoff value for the NPC-related seropositivity of EBV IgG antibodies.
    RESULTS: NPC group showed higher serum level of EBV IgG antibodies than control and other HNCA groups (P < .05). However, the traditional cutoff value, mean + 2 SDs of control subjects, failed to demarcate the seropositives of NPC patients from those of healthy population (P > .05). The new cutoff value, mean + 2 SDs of the seropositives group of control subjects who had already been grouped by the traditional cutoff value, proved successful. It succeeded to demarcate between the NPC-related EBV IgG seropositivity and that issued from the persistent, latent, or reactivated EBV infection in the population (P < .05). The sensitivity/specificity of NPC detection by the new cutoff-based ELISA kit, 76.19% and 86%, was close or higher than that of EBV IgA antibodies.
    CONCLUSION: EBV IgG-based ELISA could be used for the diagnosis of NPC using a new cutoff threshold that excludes the population baseline of EBV IgG seropositivity.
    Matched MeSH terms: Sensitivity and Specificity
  17. Wong E, Hamizan AW, Alvarado R, Orgain CA, Kalish L, Sacks R, et al.
    Am J Otolaryngol, 2018 06 22;39(5):570-574.
    PMID: 29961655 DOI: 10.1016/j.amjoto.2018.06.019
    PURPOSE: Middle turbinate head edema has recently been found to have high specificity for diagnosis of inhalant allergy. However, subtle mucosal edema can be difficult to appreciate under white light endoscopy. Narrow band imaging (NBI) has the potential to demonstrate edema by identifying reduced mucosal vascularity and improve sensitivity for the detection of mucosal edema. Narrow band imaging was assessed to determine its utility in objectifying mucosal edema.

    MEATERIALS AND METHODS: A cross-sectional diagnostic study was performed on patients with edematous mucosa of the middle turbinate head. Under traditional white light endoscopy, areas of edematous mucosa were identified. Using NBI, these areas were compared to areas of normal mucosa on the middle turbinate head. NBI images of these same areas were then converted to grey scale and a vascularity index was created by pixel analysis and brightness in Fiji Image J software (Wisconsin, US).

    RESULTS: Thirty-three middle turbinates were assessed (age 42.4 ± 12.5, 42.4% female). NBI discriminated between areas identified under white light endoscopy as edematous and normal (158.2 ± 48.4 v 96.9 ± 32.7 p 

    Matched MeSH terms: Sensitivity and Specificity
  18. Saricilar EC, Hamizan A, Alvarado R, Rimmer J, Sewell W, Tatersall J, et al.
    Am J Rhinol Allergy, 2018 Jul;32(4):244-251.
    PMID: 29785855 DOI: 10.1177/1945892418777668
    Background Rhinitis is a highly prevalent yet often misdiagnosed condition. Patients who have local allergic rhinitis are regularly mislabeled as having a nonallergic etiology. Thus, a highly accurate, reproducible, and noninvasive assessment, which can be performed quickly and with minimal discomfort to the patient, is required. Objective The aim of this research was to identify the efficiency of various nasal brushes as tools for harvest and collection of epithelial proteins and its suitability for identification of rhinitis. Methods Nasal epithelial mucosa samples were taken from patients undergoing turbinate surgery using a cytology brush, a dental brush, and a nasal curette in random order. After washing in phosphate-buffered saline, the suspended cells were sonicated. Total protein content was assessed for all samples by bicinchoninic acid assay measured using a Nanodrop machine. Identification of nasal-specific immunoglobulin E (spIgE) was then assessed using immunoassay and compared to the patient's allergic status from epicutaneous and serum testing. The lower threshold limit for the spIgE in nasal brushings was determined using the results of serum spIgE tests as the reference. The diagnostic accuracy of this new established cutoff value was determined. Results The cytology brush was found to be the optimal tool for maximal nasal mucosa protein collection followed by dental brush and nasal curette (0.75 ± 0.45 mg/mL vs 0.43 ± 0.24 mg/mL vs 0.071 ± 0.55 mg/mL, respectively; P 
    Matched MeSH terms: Sensitivity and Specificity
  19. Nurul Najian AB, Engku Nur Syafirah EA, Ismail N, Mohamed M, Yean CY
    Anal Chim Acta, 2016 Jan 15;903:142-8.
    PMID: 26709307 DOI: 10.1016/j.aca.2015.11.015
    In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10(-1) genomic equivalent ml(-1). An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device.
    Matched MeSH terms: Sensitivity and Specificity
  20. Foo PC, Chan YY, Mohamed M, Wong WK, Nurul Najian AB, Lim BH
    Anal Chim Acta, 2017 May 08;966:71-80.
    PMID: 28372729 DOI: 10.1016/j.aca.2017.02.019
    This study highlighted the development of a four target nitrocellulose-based nucleic acid lateral flow immunoassay biosensor in a dry-reagent strip format for interpretation of double-labelled double-stranded amplicons from thermostabilised triplex loop-mediated isothermal amplification assay. The DNA biosensor contained two test lines which captured biotin and texas red labelled amplicons; a LAMP internal amplification control line that captured digoxigenin labelled amplicon; and a chromatography control line that validated the functionality of the conjugated gold nanoparticles and membrane. The red lines on detection pad were generated when the gold nanoparticles conjugated antibody bound to the fluorescein labelled amplicons, and the capture agents bound to their specific hapten on the other 5' end of the double-stranded amplicon. The applicability of this DNA biosensor was demonstrated using amoebiasis-causing Entamoeba histolytica simultaneously with the non-pathogenic but morphologically identical Entamoeba dispar and Entamoeba moshkovskii. The biosensor detection limit was 10 E. histolytica trophozoites, and revealed 100% specificity when it was evaluated against 3 medically important Entamoeba species and 75 other pathogenic microorganisms. Heat stability test showed that the biosensor was stable for at least 181 days at ambient temperature. This ready-to-use and cold-chain-free biosensor facilitated the post-LAMP analysis based on visualisation of lines on strip instead of observation of amplicon patterns in agarose gel.
    Matched MeSH terms: Sensitivity and Specificity