Displaying publications 21 - 40 of 47 in total

Abstract:
Sort:
  1. James V, Kee CY, Ong GY
    J Emerg Med, 2019 Apr;56(4):421-425.
    PMID: 30638645 DOI: 10.1016/j.jemermed.2018.12.015
    BACKGROUND: Point-of-care ultrasonography (POCUS) is increasingly used for both diagnostic and guided procedures. Increasingly, POCUS has been used for identification of pneumonia and to assist in the differentiation of pleural effusions, as well as to guide thoracentesis. As such, there is a need for training with ideally high-fidelity lung ultrasound phantoms to ensure ultrasound proficiency and procedural competency. Unfortunately, most commercial ultrasound phantoms remain expensive and may have limited fidelity.

    OBJECTIVE: Our aim was to create and describe a homemade, high-fidelity ultrasound phantom model for demonstrating pneumonia with pleural effusions for teaching purposes.

    DISCUSSION: An ultrasound phantom was constructed using a water-filled latex glove with a sliver of meat in it, covered over by a palm-sized piece of meat (skin and ribs are optional to increase ultrasonographic details and realism). This would appear like parapneumonic effusions with organized pneumonia under ultrasound examination. Creamer (or talc) can be added to the water in the glove to simulate empyema. The model can also be used to teach simple effusions and for ultrasound-guided thoracentesis and in clinical decision making.

    CONCLUSIONS: Easily prepared, homemade high-fidelity ultrasound phantom models for instructions on identification of pleural effusions and ultrasound-guided pleural tap of parapneumonic effusion were made.

    Matched MeSH terms: Ultrasonography/methods*
  2. Dengler R, de Carvalho M, Shahrizaila N, Nodera H, Vucic S, Grimm A, et al.
    Clin Neurophysiol, 2020 07;131(7):1662-1663.
    PMID: 32354605 DOI: 10.1016/j.clinph.2020.03.014
    Modern neuromuscular electrodiagnosis (EDX) and neuromuscular ultrasound (NMUS) require a universal language for effective communication in clinical practice and research and, in particular, for teaching young colleagues. Therefore, the AANEM and the IFCN have decided to publish a joint glossary as they feel the need for an updated terminology to support educational activities in neuromuscular EDX and NMUS in all parts of the world. In addition NMUS has been rapidly progressing over the last years and is now widely used in the diagnosis of disorders of nerve and muscle in conjunction with EDX. This glossary has been developed by experts in the field of neuromuscular EDX and NMUS on behalf of the AANEM and the IFCN and has been agreed upon by electronic communication between January and November 2019. It is based on the glossaries of the AANEM from 2015 and of the IFCN from 1999. The EDX and NMUS terms and the explanatory illustrations have been updated and supplemented where necessary. The result is a comprehensive glossary of terms covering all fields of neuromuscular EDX and NMUS. It serves as a standard reference for clinical practice, education and research worldwide.
    Matched MeSH terms: Ultrasonography/methods
  3. Kurien M, Teo R, Zainuddin K, Azidin AM, Izaham A, Budiman M, et al.
    Clin Ter, 2021 Jul 05;172(4):278-283.
    PMID: 34247211 DOI: 10.7417/CT.2021.2332
    Objective: We compared sonoanatomy of the internal jugular vein (IJV) the high (HA), conventional (CA) and the medial oblique approach (MA) to identify the best approach and head position for IJV cannulation.

    Materials & Methods: Total of 45 volunteers aged 18-65 years were included in this study. The degree of overlap in percentage, depth of IJV from skin, antero-posterior (AP) and transverse diameters (TD) of IJV were measured in real time with ultrasound (US). Measurements were taken in the HA, CA and MA in neutral and 30° head rotation on both the right and left side of the neck.

    Results: The HA had lower percentage of overlap when compared to CA and MA in neutral and 30° head rotation (p= 0.002 to ≤0.001). The IJV was more shallow in the CA and MA. The AP and TD of the IJV were larger in the MA when compared to HA (p=<0.001) and CA (p =0.026 to < 0.001) and the right IJV has a larger AP and TD in all approaches.

    Discussion: The HA had the least percentage of overlap compared to CA and MA, therefore the risk of accidental ICA puncture can be reduced. The apparent overlap seen in MA may not reflect the actual scenario because of the way the US beam cuts the vessel. The AP and TD of IJV were significantly increased in the MA, which would ease CVC.

    Conclusion: We conclude and recommend the medial oblique probe position with 30° head rotation provides optimal real time sonographic parameters for US guided IJV cannulation.

    Matched MeSH terms: Ultrasonography/methods*
  4. Mohd Asihin MA, Bajuri MY, Ahmad J, Syed Kamaruddin SF
    Ceylon Med J, 2018 03 31;63(1):11-16.
    PMID: 29754479
    Objectives: To evaluate the feasibility of ultrasonographic examination in predicting 4-strand semitendinosus and gracilis tendon (4S-STG) autograft size preoperatively in anterior cruciate ligament reconstruction and to evaluate the use of anthropometric measurement to predict the 4-strand semitendinosus and gracilis tendons (4S-STG) autograft size pre-operatively in anterior cruciate ligament reconstruction.

    Method: Twenty-seven patients were included in this study conducted from 1st January to 31st December 2013. All patients were skeletally mature and scheduled to undergo primary anterior cruciate ligament reconstruction using 4S-STG autograft. Ultrasonographic examination of semitendinosus and gracilis tendons to measure the cross sectional area was conducted and anthropometric data (weight, height, leg length and thigh circumference) was measured one day prior to surgery. True autograft diameters were measured intraoperatively using closed-hole sizing block in 0.5 mm incremental size.

    Results: There is a statistically significant correlation between the measured combined cross sectional area (semitendinosus and gracilis tendons) and 4S-STG autograft diameter (p = 0.023). An adequate autograft size (at least 7 mm) can be obtained when the combined cross sectional area is at least 15 mm2. There was no correlation with the anthropometric data except for thigh circumference (p = 0.037). Autograft size of at least 7 mm can be obtained when the thigh circumference is at least 41 mm.

    Conclusions: Both combined cross sectional area (semitendinosus and gracilis tendons) and thigh circumference can be used to predict an adequate 4S-STG autograft size.

    Matched MeSH terms: Ultrasonography/methods*
  5. Kho SS, Yong MC, Chan SK, Tie ST
    Thorax, 2018 10;73(10):994-995.
    PMID: 29599199 DOI: 10.1136/thoraxjnl-2018-211729
    Matched MeSH terms: Ultrasonography/methods
  6. Atan IK, Lin S, Dietz HP, Herbison P, Wilson PD, ProLong Study Group
    J Ultrasound Med, 2018 Dec;37(12):2829-2839.
    PMID: 29675869 DOI: 10.1002/jum.14641
    OBJECTIVES: This study aimed to ascertain the association between levator avulsion and pelvic organ prolapse (POP).

    METHODS: This was a cross-sectional study involving 195 women enrolled in a longitudinal cohort study and seen 20 years after an index birth. All had a standardized patient-administered questionnaire, the International Continence Society Pelvic Organ Prolapse Quantification assessment and 4D translabial ultrasound. Main outcome measures were objective POP clinically and on translabial ultrasound. Postimaging assessment of levator integrity and sonographically determined pelvic organ descent was done blinded against other data.

    RESULTS: Of 195 women who were seen a mean of 23 (range, 19.4-46.2) years after their first birth, one declined ultrasound assessment and was excluded, leaving 194. Mean age was 50.2 (range 36.9-66.5) years with a mean body mass index (BMI) of 27.6 (range, 18.3-54.3) kg/m2 . Median parity was 3 (range 1-14). Ninety-one percent (n = 176) had delivered vaginally. Eighteen percent (n = 34) were symptomatic of prolapse. Clinically, 36% (n = 69) had significant POP. Levator avulsion was diagnosed in 16% (n = 31). Mean levator avulsion defect score was 2.2 (range, 0-12). On univariate analysis, levator avulsion and levator avulsion defect score were associated with clinically and sonographically significant POP, that is, odds ratio 2.6 (1.2-5.7), P = .01; and odds ratio 3.3 (1.4-7.7); P = .003, respectively; Ba (P 

    Matched MeSH terms: Ultrasonography/methods
  7. Shahrizaila N, Noto Y, Simon NG, Huynh W, Shibuya K, Matamala JM, et al.
    Clin Neurophysiol, 2017 Jan;128(1):227-232.
    PMID: 27940147 DOI: 10.1016/j.clinph.2016.11.010
    OBJECTIVE: The utility of quantitative muscle ultrasound as a marker of disease severity in Charcot-Marie-Tooth (CMT) disease subtypes was investigated.

    METHODS: Muscle ultrasound was prospectively performed on 252 individual muscles from 21 CMT patients (9 CMT1A, 8 CMTX1, 4 CMT2A) and compared to 120 muscles from 10 age and gender-matched controls. Muscle ultrasound recorded echogenicity and thickness in representative muscles including first dorsal interosseus (FDI) and tibialis anterior (TA).

    RESULTS: Muscle volume of FDI and thickness of TA correlated with MRC strength. Muscle echogenicity was significantly increased in FDI (65.05 vs 47.09; p<0.0001) and TA (89.45 vs 66.30; p<0.0001) of CMT patients. In TA, there was significantly higher muscle thickness (23 vs 18 vs 16mm; p<0.0001) and lower muscle echogenicity (80 vs 95 vs 108; p<0.0001) in CMT1A compared to CMTX1 and CMT2A. This corresponded to disease severity based on muscle strength (MRC grading CMT1A vs CMTX1 vs CMT2A: 59 vs 48 vs 44; p=0.002).

    CONCLUSION: In CMT, quantitative muscle ultrasound of FDI and TA is a useful marker of disease severity.

    SIGNIFICANCE: The current findings suggest that quantitative muscle ultrasound has potential as a surrogate marker of disease progression in future interventional trials in CMT.

    Matched MeSH terms: Ultrasonography/methods*
  8. George J, Jaafar Z, Hairi IR, Hussein KH
    J Sports Med Phys Fitness, 2020 May;60(5):749-757.
    PMID: 32141272 DOI: 10.23736/S0022-4707.20.10050-1
    BACKGROUND: The objectives of this study were to find correlation between the clinical and ultrasound grading in anterior talofibular ligament and calcaneofibular ligament tear, and to determine the sensitivity and specificity of the two stability tests among the athletes. Subsequently, we would like to propose a new grading criterion for an ultrasound examination.

    METHODS: Two blinded assessors examined thirty-five patients with a history of recent lateral ankle sprain. The first assessor performed physical examination on the injured ankle by using the anterior drawer test and talar tilt test, and the second assessor performed dynamic and static ultrasound assessment for anterior talofibular ligament and calcaneofibular ligament. The clinical laxity grading and sonographic extent of ligamentous injury was graded into a three-point scale.

    RESULTS: There was a moderate positive correlation between clinical test and ultrasound grading of anterior talofibular ligament and calcaneofibular ligament with Spearman's correlation coefficient values of 0.58 and 0.66 respectively. Clinical grading of anterior drawer test had 59.1% sensitivity (95% CI: 0.36-0.79) while ultrasound grading had 100.0% specificity (95% CI: 0.75-1.00), with positive likelihood ratio of 0.77 and negative likelihood ratio of 0.44 in detecting a complete (grade 3) anterior talofibular ligament tear (P<0.05). Meanwhile, the clinical grading of talar tilt test had 54.5% sensitivity (95% CI: 0.23-0.83) and ultrasound grading had 100.0% specificity (95% CI: 0.85-1.00), with positive likelihood ratio of 1.0 and negative likelihood ratio of 0.45 in detecting a complete grade 3 calcaneofibular ligament tear (P<0.05).

    CONCLUSIONS: The dynamic ultrasound is recommended to determine the actual degree of disruption of the ligament especially when clinical grading under-grades the degree of tear. Grade 2 tears can vary from 10% tear to 90% tear causing the clinical correlation to become less strong. We recommend a new classification for ultrasound grading of grade 2 tears, which could result in a stronger correlation between clinical and ultrasound grading.

    Matched MeSH terms: Ultrasonography/methods*
  9. Acharya UR, Raghavendra U, Fujita H, Hagiwara Y, Koh JE, Jen Hong T, et al.
    Comput Biol Med, 2016 12 01;79:250-258.
    PMID: 27825038 DOI: 10.1016/j.compbiomed.2016.10.022
    Fatty liver disease (FLD) is reversible disease and can be treated, if it is identified at an early stage. However, if diagnosed at the later stage, it can progress to an advanced liver disease such as cirrhosis which may ultimately lead to death. Therefore, it is essential to detect it at an early stage before the disease progresses to an irreversible stage. Several non-invasive computer-aided techniques are proposed to assist in the early detection of FLD and cirrhosis using ultrasound images. In this work, we are proposing an algorithm to discriminate automatically the normal, FLD and cirrhosis ultrasound images using curvelet transform (CT) method. Higher order spectra (HOS) bispectrum, HOS phase, fuzzy, Kapoor, max, Renyi, Shannon, Vajda and Yager entropies are extracted from CT coefficients. These extracted features are subjected to locality sensitive discriminant analysis (LSDA) feature reduction method. Then these LSDA coefficients ranked based on F-value are fed to different classifiers to choose the best performing classifier using minimum number of features. Our proposed technique can characterize normal, FLD and cirrhosis using probabilistic neural network (PNN) classifier with an accuracy of 97.33%, specificity of 100.00% and sensitivity of 96.00% using only six features. In addition, these chosen features are used to develop a liver disease index (LDI) to differentiate the normal, FLD and cirrhosis classes using a single number. This can significantly help the radiologists to discriminate FLD and cirrhosis in their routine liver screening.
    Matched MeSH terms: Ultrasonography/methods*
  10. Young N, Atan IK, Rojas RG, Dietz HP
    Int Urogynecol J, 2018 08;29(8):1129-1134.
    PMID: 28914337 DOI: 10.1007/s00192-017-3455-8
    INTRODUCTION AND HYPOTHESIS: The objective was to determine the association between body mass index (BMI) and symptoms and signs of female pelvic organ prolapse (POP).

    METHODS: An observational cross-sectional study of 964 archived datasets of women seen for symptoms and signs of lower urinary tract and pelvic organ dysfunction between September 2011 and February 2014 at a tertiary urogynaecology centre in Australia was carried out. An in-house standardised interview, the International Continence Society Pelvic Organ Prolapse Quantification (ICS POP-Q) and 4-D translabial ultrasound, followed by analysis of ultrasound volumes for pelvic organ descent and hiatal area on Valsalva, were performed, blinded against other data.

    RESULTS: There is a positive association between BMI and posterior compartment prolapse on clinical examination and ultrasound imaging, but not for the anterior and central compartments. There was no association with prolapse symptom bother and a negative association with symptoms of prolapse.

    CONCLUSIONS: In this observational study, we found a strong association between all tested measures of posterior compartment descent and BMI, both clinical and on imaging.

    Matched MeSH terms: Ultrasonography/methods*
  11. Mohafez H, Ahmad SA, Hadizadeh M, Moghimi S, Roohi SA, Marhaban MH, et al.
    Skin Res Technol, 2018 Feb;24(1):45-53.
    PMID: 28557064 DOI: 10.1111/srt.12388
    PURPOSE: We aimed to develop a method for quantitative assessment of wound healing in ulcerated diabetic feet.

    METHODS: High-frequency ultrasound (HFU) images of 30 wounds were acquired in a controlled environment on post-debridement days 7, 14, 21, and 28. Meaningful features portraying changes in structure and intensity of echoes during healing were extracted from the images, their relevance and discriminatory power being verified by analysis of variance. Relative analysis of tissue healing was conducted by developing a features-based healing function, optimised using the pattern-search method. Its performance was investigated through leave-one-out cross-validation technique and reconfirmed using principal component analysis.

    RESULTS: The constructed healing function could depict tissue changes during healing with 87.8% accuracy. The first principal component derived from the extracted features demonstrated similar pattern to the constructed healing function, accounting for 86.3% of the data variance.

    CONCLUSION: The developed wound analysis technique could be a viable tool in quantitative assessment of diabetic foot ulcers during healing.

    Matched MeSH terms: Ultrasonography/methods
  12. Ong LC, Kanaheswari Y, Chandran V, Rohana J, Yong SC, Boo NY
    Singapore Med J, 2009 Jul;50(7):705-9.
    PMID: 19644627
    The early identification of asphyxiated infants at high risk of adverse outcomes and the early selection of those who might benefit from neuroprotective therapies are required. A prospective observational study was conducted to determine if there were any early clinical, neuroimaging or neurophysiological parameters that might predict the outcome in term newborns with asphyxia.
    Matched MeSH terms: Ultrasonography/methods*
  13. Dessole S, Farina M, Capobianco G, Nardelli GB, Ambrosini G, Meloni GB
    Fertil Steril, 2001 Sep;76(3):605-9.
    PMID: 11532488
    OBJECTIVE: To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost.

    DESIGN: Prospective study.

    SETTING: University hospital.

    PATIENT(S): Six hundred ten women undergoing SHG.

    INTERVENTION(S): We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN).

    MAIN OUTCOME MEASURE(S): We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters.

    RESULT(S): In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive.

    CONCLUSION(S): The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

    Matched MeSH terms: Ultrasonography/methods
  14. Chan WK, Petta S, Noureddin M, Goh GBB, Wong VW
    Aliment Pharmacol Ther, 2024 Jun;59 Suppl 1:S23-S40.
    PMID: 38813831 DOI: 10.1111/apt.17866
    BACKGROUND: Metabolic dysfunction-associated steatotic liver disease (MASLD) is currently the most common chronic liver disease and an important cause of cirrhosis and hepatocellular carcinoma. It is strongly associated with type 2 diabetes and obesity. Because of the huge number of patients at risk of MASLD, it is imperative to use non-invasive tests appropriately.

    AIMS: To provide a narrative review on the performance and limitations of non-invasive tests, with a special emphasis on the impact of diabetes and obesity.

    METHODS: We searched PubMed and Cochrane databases for articles published from 1990 to August 2023.

    RESULTS: Abdominal ultrasonography remains the primary method to diagnose hepatic steatosis, while magnetic resonance imaging proton density fat fraction is currently the gold standard to quantify steatosis. Simple fibrosis scores such as the Fibrosis-4 index are well suited as initial assessment in primary care and non-hepatology settings to rule out advanced fibrosis and future risk of liver-related complications. However, because of its low positive predictive value, an abnormal test should be followed by specific blood (e.g. Enhanced Liver Fibrosis score) or imaging biomarkers (e.g. vibration-controlled transient elastography and magnetic resonance elastography) of fibrosis. Some non-invasive tests of fibrosis appear to be less accurate in patients with diabetes. Obesity also affects the performance of abdominal ultrasonography and transient elastography, whereas magnetic resonance imaging may not be feasible in some patients with severe obesity.

    CONCLUSIONS: This article highlights issues surrounding the clinical application of non-invasive tests for MASLD in patients with type 2 diabetes and obesity.

    Matched MeSH terms: Ultrasonography/methods
  15. Tan HH, Tan SK, Shunmugan R, Zakaria R, Zahari Z
    Sultan Qaboos Univ Med J, 2017 Nov;17(4):e455-e459.
    PMID: 29372089 DOI: 10.18295/squmj.2017.17.04.013
    Persistent urogenital sinus (PUGS) is a rare anomaly whereby the urinary and genital tracts fail to separate during embryonic development. We report a three-year-old female child who was referred to the Sabah Women & Children Hospital, Sabah, Malaysia, in 2016 with a pelvic mass. She had been born prematurely at 36 gestational weeks via spontaneous vaginal delivery in 2013 and initially misdiagnosed with neurogenic bladder dysfunction. The external genitalia appeared normal and an initial sonogram and repeat micturating cystourethrograms did not indicate any urogenital anomalies. She therefore underwent clean intermittent catheterisation. Three years later, the diagnosis was corrected following the investigation of a persistent cystic mass posterior to the bladder. At this time, a clinical examination of the perineum showed a single opening into the introitus. Magnetic resonance imaging of the pelvis revealed gross hydrocolpos and a genitogram confirmed a diagnosis of PUGS, for which the patient underwent surgical separation of the urinary and genital tracts.
    Matched MeSH terms: Ultrasonography/methods
  16. Nusee Z, Ibrahim N, Rus RM, Ismail H
    Taiwan J Obstet Gynecol, 2014 Mar;53(1):12-6.
    PMID: 24767639 DOI: 10.1016/j.tjog.2013.01.028
    To determine the accuracy of bladder volume (BV) measurement and to identify factors that influenced the ultrasound bladder scanner (UBS) measurement of BV in postpartum women compared with transurethral catheterization.
    Matched MeSH terms: Ultrasonography/methods*
  17. Zain JM, Fauzi AM, Aziz AA
    Conf Proc IEEE Eng Med Biol Soc, 2007 10 20;2006:5459-62.
    PMID: 17946306
    Digital watermarking medical images provides security to the images. The purpose of this study was to see whether digitally watermarked images changed clinical diagnoses when assessed by radiologists. We embedded 256 bits watermark to various medical images in the region of non-interest (RONI) and 480K bits in both region of interest (ROI) and RONI. Our results showed that watermarking medical images did not alter clinical diagnoses. In addition, there was no difference in image quality when visually assessed by the medical radiologists. We therefore concluded that digital watermarking medical images were safe in terms of preserving image quality for clinical purposes.
    Matched MeSH terms: Ultrasonography/methods*
  18. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Ng KH
    Ultrasound Med Biol, 2019 06;45(6):1417-1426.
    PMID: 30962016 DOI: 10.1016/j.ultrasmedbio.2019.01.024
    The purpose of this study was to assess the potential of shear wave elastography (SWE) as an indicator of abnormal kidney function defined by radiolabeled glomerular filtration rate (GFR). Fifty-seven patients referred for 51Cr-ethylenediaminetetraacetic acid GFR and 99mTc-dimercaptosuccinic acid renal scintigraphy were included. Young's modulus (YM) measured with SWE and kidney length, volume, cortical thickness and parenchymal echogenicity measured with conventional ultrasound were correlated with patients' GFR and renal scintigraphy results. Spearman correlation coefficients between SWE and GFR were negative for the right (r = -0.635, p < 0.0001) and left (r = -0.817, p < 0.0001) kidneys. Positive correlations between left renal cortical thickness (r = 0.381, p = 0.04) and left kidney volume (r = 0.356, p = 0.019) with GFR were reported. SWE correctly predicted the dominant functioning kidney in 94.7% of cases. The area under the receiver operating characteristic curve for SWE (0.800) was superior to that for conventional ultrasound (0.252-0.415). The cutoff value of ≥5.52 kPa suggested a kidney function ≤60 mL/min/1.73 m2 (82.4% sensitivity and 76.2% specificity). SWE has advantages over conventional ultrasound in assessing kidney function and distinguishing the dominant functioning kidney.
    Matched MeSH terms: Ultrasonography/methods*
  19. Trutnovsky G, Kamisan Atan I, Ulrich D, Martin A, Dietz HP
    Acta Obstet Gynecol Scand, 2016 Dec;95(12):1411-1417.
    PMID: 27622984 DOI: 10.1111/aogs.13018
    INTRODUCTION: The study aimed to analyze the relation between the degree of puborectalis muscle trauma and subjective symptoms and objective findings of pelvic organ prolapse (POP), comparing two continuous scoring systems with a discrete scoring system for translabial ultrasound imaging.

    MATERIAL AND METHODS: In this retrospective observational study the records of patients attending a tertiary urogynecological unit between January 2012 and December 2014 were analyzed. POP assessment included a standardized interview, clinical examination using Pelvic Organ Prolapse Quantification and four-dimensional translabial ultrasound. Puborectalis muscle trauma was assessed with tomographic ultrasound imaging using two continuous scoring systems and a previously established discrete system. Receiver operating characteristics and adjusted odds ratios were used for comparison of scoring systems in predicting symptoms and signs of POP.

    RESULTS: Of 1258 women analyzed, 52.6% complained of prolapse symptoms. On ultrasound imaging, 65.7% of women had sonographically significant POP. Complete avulsion was diagnosed in 25.3% of women, being unilateral in 13.9% and bilateral in 11.4%. A maximum score in the 6-point and the 12-point tomographic ultrasound imaging scale increased the odds for a diagnosis of any significant POP on ultrasound by 4.4 and 4.8 times, respectively, compared with 4.6 times for the discrete diagnosis of bilateral avulsion. For all avulsion scoring systems the relation was strongest for cystocele and uterine prolapse.

    CONCLUSIONS: A continuous avulsion scoring system based on tomographic findings does not provide superior performance for the prediction of subjective symptoms and objective findings of prolapse compared with a discrete diagnostic system of unilateral or bilateral avulsion.

    Matched MeSH terms: Ultrasonography/methods
  20. Raghavendra U, Rajendra Acharya U, Gudigar A, Hong Tan J, Fujita H, Hagiwara Y, et al.
    Ultrasonics, 2017 05;77:110-120.
    PMID: 28219805 DOI: 10.1016/j.ultras.2017.02.003
    Thyroid is a small gland situated at the anterior side of the neck and one of the largest glands of the endocrine system. The abrupt cell growth or malignancy in the thyroid gland may cause thyroid cancer. Ultrasound images distinctly represent benign and malignant lesions, but accuracy may be poor due to subjective interpretation. Computer Aided Diagnosis (CAD) can minimize the errors created due to subjective interpretation and assists to make fast accurate diagnosis. In this work, fusion of Spatial Gray Level Dependence Features (SGLDF) and fractal textures are used to decipher the intrinsic structure of benign and malignant thyroid lesions. These features are subjected to graph based Marginal Fisher Analysis (MFA) to reduce the number of features. The reduced features are subjected to various ranking methods and classifiers. We have achieved an average accuracy, sensitivity and specificity of 97.52%, 90.32% and 98.57% respectively using Support Vector Machine (SVM) classifier. The achieved maximum Area Under Curve (AUC) is 0.9445. Finally, Thyroid Clinical Risk Index (TCRI) a single number is developed using two MFA features to discriminate the two classes. This prototype system is ready to be tested with huge diverse database.
    Matched MeSH terms: Ultrasonography/methods*