Displaying publications 21 - 40 of 48 in total

Abstract:
Sort:
  1. Eamsobhana P, Prasartvit A, Gan XX, Yong HS
    Trop Biomed, 2015 Mar;32(1):121-5.
    PMID: 25801261
    Angiostrongylus cantonensis is the most frequent cause of eosinophilic meningitis in humans in Thailand and worldwide. Because of difficulty of recovering the Angiostrongylus larvae from infected patients, detection of parasite-specific antibodies is used to support clinical diagnosis. This study tested serum samples from eosinophilic meningitis patients and individuals at risk of infection with A. cantonensis to evaluate a recently developed simple and rapid dot-immunogold filtration assay (DIGFA) for detection of specific antibodies against A. cantonensis. Purified 31-kDa glycoprotein of A. cantonensis and protein A colloidal gold conjugate were employed to detect the 31-kDa anti-A. cantonensis antibody in patients sera from the parasite endemic areas of northeast Thailand. The results were compared with those obtained by dot-blot enzyme-linked immunosorbent assay (ELISA) with 31-kDa A. cantonensis antigen. The overall positivity rate of DIGFA and dot-blot ELISA for A. cantonensis infection in 98 clinically diagnosed cases from three highly endemic districts in Khon Kaen province were 39.79% and 37.75%, respectively. Among 86 sera of subjects at risk of infection with A. cantonensis, 24.41% were positive by DIGFA and 23.25% by dot-blot ELISA. There were good correlation between the visual grading of DIGFA and dot-blot ELISA in both groups of defined sera. DIGFA is as sensitive and specific as dot-blot ELISA for confirming eosinophilic meningitis due to A. cantonensis infection, with advantages of simplicity, rapidity and without the use of specific and expensive equipment, and can be used in field settings.
    Matched MeSH terms: Antigens, Helminth/immunology
  2. Khalilpour A, Sadjjadi SM, Moghadam ZK, Yunus MH, Zakaria ND, Osman S, et al.
    Am J Trop Med Hyg, 2014 Nov;91(5):994-9.
    PMID: 25200268 DOI: 10.4269/ajtmh.14-0170
    Cystic echinococcosis (CE) caused by infection with Echinococcus granulosus is of major concern for humans in many parts of the world. Antigen B was prepared from E. granulosus hydatid fluid, and Western blots confirmed eight batches showing a band corresponding to the 8-/12-kDa subunit with positive serum and no low-molecular mass band (< 15 kDa) with negative serum. The batches were pooled and used to prepare lateral flow immunoglobulin G4 (IgG4) and IgG dipsticks. Diagnostic sensitivity was determined using serum samples from 21 hydatidosis patients, and diagnostic specificity was established using sera from 17 individuals infected with other parasites and 15 healthy people. IgG4 dipstick had a diagnostic sensitivity of 95% (20 of 21) and a specificity of 100% (32 of 32). The IgG dipstick had a sensitivity of 100% (21 of 21) and a specificity of 87.5% (28 of 32). Thus, both IgG and IgG4 dipsticks had high sensitivities, but IgG4 had greater specificity for the diagnosis of human CE.
    Matched MeSH terms: Antigens, Helminth/blood; Antigens, Helminth/immunology
  3. Sahu PS, Parija S, Kumar D, Jayachandran S, Narayan S
    Parasite Immunol., 2014 Oct;36(10):509-21.
    PMID: 24965663 DOI: 10.1111/pim.12124
    Traditionally serum and/or CSF specimens have been used for detection of either specific antibodies or antigens as a supportive diagnosis of NCC. However, in recent days, much interest has been shown employing noninvasive specimens such as urine. In our study, we identified and compared a profile of circulating antigenic peptides of parasite origin in three different body fluids (CSF, serum and urine) obtained from confirmed NCC cases and control subjects. The circulating antigenic peptides were resolved by SDS-PAGE and subjected to immunoblotting. For confirmation of their origin as parasite somatic or excretory secretory (ES) material, immunoreactivity was tested employing affinity purified polyclonal Taenia solium metacestode anti-somatic or ES antibodies, respectively. Only lower molecular weight antigenic peptides were found circulating in urine in contrast to serum and CSF specimens. Few somatic peptides were identified to be 100% specific for NCC (19·5 kDa in all three specimens; 131, 70 kDa in CSF and serum only; 128 kDa in CSF only). Similarly, the specific ES peptides detected were 32 kDa (in all three specimens), 16·5 kDa (in serum and CSF only), and 15 kDa (urine only). A test format detecting either one or more of these specific peptides would enhance the sensitivity in diagnosis of NCC.
    Matched MeSH terms: Antigens, Helminth/analysis*; Antigens, Helminth/blood; Antigens, Helminth/cerebrospinal fluid; Antigens, Helminth/immunology; Antigens, Helminth/urine
  4. Manuel AM, Kuljit S, Gopalakrishnan G, Suresh KG, Balraj P
    Trop Biomed, 2012 Sep;29(3):360-5.
    PMID: 23018498 MyJurnal
    The purpose of this study is to determine the relevance of the hygiene hypothesis; that is to determine if worm infestation has a protective role against the development of allergic rhinitis. A prospective case controlled study was conducted. Specific IgG levels to Toxocara were studied in 85 patients confirmed to have allergic rhinitis and were compared to levels in another 85 controls, with no form of allergy. The IgG assay was done using ELISA technique. There was a higher incidence of positive specific IgG to Toxocara in the controls as compared to allergic patients. The values were statistically significant [Chi square test (p=0.002)]. This negative association between worm infestation and allergic rhinitis suggests that a previous worm infestation could protect against the development of allergic rhinitis.
    Matched MeSH terms: Antigens, Helminth/blood
  5. Khoo TK, Noordin R, Santhanam A
    Indian J Exp Biol, 2012 Apr;50(4):256-64.
    PMID: 22611913
    A rapid antibody detection test is very useful for the detection of lymphatic filariasis, especially for certification and surveillance of post-mass drug administration. panLF Rapid kit is suitable for this purpose since it can detect all species of lymphatic filaria. It is based on the detection of anti-filarial IgG4 antibodies that react with recombinant B. malayi antigens, BmR1 and BmSXP. There is an increase demand for the test due to its attributes of being rapid, sensitive and specific results, as well as its field-applicability. The main aim of this paper is to obtain high recovery and purity of recombinant antigen BmSXP via a modified method of immobilized metal affinity chromatography (IMAC). The highest product yield of 11.82 mg/g dry cell weight (DCW) was obtained when IMAC was performed using the optimized protocol of 10 mM imidazole concentration in lysis buffer, 30 mM imidazole concentration in wash buffer, and 10 column volume wash buffer containing 300 mM salt concentration. This gave a 54% protein recovery improvement over the manufacturer's protocol which recorded a product yield of only 7.68 mg/g DCW. The recovered BmSXP recombinant antigen showed good western blot reactivity, high sensitivity (31/32, 97%) and specificity (32/32, 100%) in ELISA, thus attesting to its good purity and quality.
    Matched MeSH terms: Antigens, Helminth/analysis*; Antigens, Helminth/isolation & purification
  6. Noordin R, Muhi J, Md Idris Z, Arifin N, Kiyu A
    Trop Biomed, 2012 Mar;29(1):191-6.
    PMID: 22543621 MyJurnal
    The detection rates of brugian filariasis in three regions of Sarawak namely Central, North and South after three courses of mass drug administration (MDA) from year 2004 to 2006 was investigated. A recombinant BmR1 antigen-based IgG4 detection test, named Brugia Rapid and night blood smear for microfilaria (mf) detection were used. All three regions recorded a sharp fall in mf positive rates after a year post-MDA. Meanwhile Brugia Rapid positive rates declined more gradually to 3.8% and 5.6% of the pre-MDA levels in the Central and North regions, respectively. This study showed that in filariasis endemic areas in Sarawak, anti-filarial IgG4 antibodies to BmR1, as detected by the Brugia Rapid test, were positive for one to two years after mf disappearance.
    Matched MeSH terms: Antigens, Helminth
  7. Norsyahida A, Rahmah N, Ahmad RM
    Lett Appl Microbiol, 2009 Nov;49(5):544-50.
    PMID: 19832937 DOI: 10.1111/j.1472-765X.2009.02694.x
    To investigate the effects of feeding and induction strategies on the production of BmR1 recombinant antigen.
    Matched MeSH terms: Antigens, Helminth/genetics; Antigens, Helminth/metabolism*
  8. Norhaida A, Suharni M, Liza Sharmini AT, Tuda J, Rahmah N
    Ann Trop Med Parasitol, 2008 Mar;102(2):151-60.
    PMID: 18318937 DOI: 10.1179/136485908X252250
    Currently, the laboratory diagnosis of toxocariasis, caused by Toxocara canis or T. cati, mainly relies on serological tests. Unfortunately, however, the specificities of most of the commercial tests that are available for the serodiagnosis of this disease are not very high and this may cause problems, especially in tropical countries where co-infections with other helminths are common. In an effort to develop a serological assay with improved specificity for the detection of Toxocara infection, an IgG(4)-ELISA based on a recombinant version (rTES-30USM) of the 30-kDa Toxocara excretory-secretory antigen (TES-30) has recently been developed. To produce the antigen, the TES-30 gene was cloned via assembly PCR, subcloned into a His-tagged prokaryotic expression vector, and purified by affinity chromatography using Ni(2+)-nitrilotriacetic-acid (Ni-NTA) resin. The performance of the ELISA based on the recombinant antigen was then compared with that of commercial kit, based on an IgG-ELISA, for the serodiagnosis of toxocariasis (Toxocara IgG-ELISA; Cypress Diagnostics, Langdorp, Belgium). Both assays were used to test 338 serum samples, including 26 samples from probable cases of toxocariasis. Assuming that all the probable cases were true cases, the assay based on rTES-30USM demonstrated a sensitivity of 92.3% (24/26) and a specificity of 89.6% (103/115) whereas the commercial kit exhibited a sensitivity of 100% (26/26) but a specificity of only 55.7% (64/115). The high sensitivity and specificity exhibited by the new IgG(4)-ELISA should make the assay a good choice for use in tropical countries and any other area where potentially cross-reactive helminthic infections are common.
    Matched MeSH terms: Antigens, Helminth/analysis; Antigens, Helminth/genetics*; Antigens, Helminth/immunology
  9. Fong MY, Lau YL
    Parasitol Res, 2004 Jan;92(2):173-6.
    PMID: 14655048
    A gene encoding the larval excretory-secretory antigen TES-120 of the dog ascarid worm Toxocara canis was cloned into the methylotrophic yeast Pichia pastoris. Specificity of the recombinant TES-120 antigen produced by the yeast was investigated. Forty-five human serum samples from patients infected with different()parasitic organisms, including 8 cases of toxocariasis, were tested against the recombinant antigen in immunoblot assays. Results from the assays showed that the recombinant TES-120 antigen reacted with sera from toxocariasis patients only. This highly specific recombinant TES-120 antigen can potentially be used for the development of an inexpensive serodiagnostic assay for human toxocariasis.
    Matched MeSH terms: Antigens, Helminth/genetics; Antigens, Helminth/immunology*; Antigens, Helminth/metabolism
  10. Lim BH, Noordin R, Nor ZM, Rahman RA, Abdullah KA, Sinnadurai S
    Exp Parasitol, 2004 Sep-Oct;108(1-2):1-6.
    PMID: 15491542
    BmR1 recombinant antigen has previously been shown to demonstrate high sensitivity and specificity in the serological diagnosis of brugian filariasis in humans. In this study, the pattern of recognition of antibody to BmR1 during Brugia malayi infection was investigated by employing Meriones unguiculatus as the experimental model. Thirty two gerbils were infected subcutaneously with 120 L(3); and two control groups each comprising 25 animals were employed. ELISA using BmR1 was used to detect filaria-specific IgG antibodies elicited by the gerbils; using sera collected from the day 1 until day 150 post-inoculation (p.i.). The results showed that BmR1 detected B. malayi infection in gerbils harboring adult worms irrespective of the presence of circulating microfilaria, and was exemplified by positive ELISA results in nine a microfilaraemic animals that harbored live adult worms. The initial time of the antibody recognition was at day 8 p.i. and the antibody titre showed some correlation with adult worm burden.
    Matched MeSH terms: Antigens, Helminth/immunology*
  11. Noordin R, Shenoy RK, Rahman RA
    PMID: 15115085
    Brugia malayi infection is endemic in several Asian countries. Filaria-specific IgG4 antibody detection based on BmR1 recombinant antigen has been shown to be sensitive and specific for the diagnosis of brugian filariasis. Two formats of the test has been reported ie indirect ELISA (BE) and rapid dipstick test (BR). Since different test formats use different amounts of sample and reagents which may affect its sensitivity and specificity, this study was performed to compare these two test formats in the detection of B. malayi. A total of 264 blinded serum samples from India and Malaysia were employed. Group 1 comprised 164 samples from actively infected individuals and group 2 comprised 100 samples from filaria non-endemic areas. Sensitivity was 96.3% (158/164) and 90.8% (149/164) for rapid test and ELISA respectively; chi-square p=0.00. Both test formats demonstrated 100% specificity. Therefore the rapid test format was equally specific but more sensitive than the ELISA format. The ELISA format would be able to demonstrate decline in IgG4 titer post-treatment while the rapid test would be very useful for screening and diagnosis in the field.
    Matched MeSH terms: Antigens, Helminth
  12. Rahmah N, Shenoy RK, Nutman TB, Weiss N, Gilmour K, Maizels RM, et al.
    Trop Med Int Health, 2003 Oct;8(10):895-900.
    PMID: 14516300
    A multicentre evaluation of the Brugia Rapid dipstick test was performed using 1263 serum samples in four international laboratories, i.e. T.D. Medical College (TDMC, India), National Institutes of Health (NIH, USA), Swiss Tropical Institute (STI, Switzerland) and Leiden University Medical Centre (LUMC, Netherlands). In comparison with microscopy, the dipstick demonstrated sensitivities of 97.2% (70 of 72) at TDMC, 91.6% (175 of 191) at LUMC and 100% (six of six) at STI. Sera of chronic patients showed a positivity rate of 11.3% (19 of 168) and 61.2% (71of 116) at TDMC and LUMC, respectively. All 266 sera of non-endemic normals from STI, NIH and LUMC tested negative with the dipstick. At LUMC, sera of 'endemic normals' (amicrofilaraemics with no clinical disease) from an area with approximately 35% microfilaria positivity showed 60.8% positive results (31 of 51), thus demonstrating the likelihood of many cryptic infections occurring in this population. Specificities of the test with Onchocerca volvulus sera were 98.8% (80 of 81) and 100% (10 of 10) at the NIH and STI, respectively; while specificity with Loa loa sera at the NIH was 84.6% (44 of 52). At the STI, the dipstick test also demonstrated 100% specificity when tested with 75 sera from various protozoan and helminthic infections.
    Matched MeSH terms: Antigens, Helminth/analysis
  13. Rahmah N, Lim BH, Azian H, Ramelah TS, Rohana AR
    Trop Med Int Health, 2003 Feb;8(2):158-63.
    PMID: 12581442
    Brugian filariasis infects 13 million people in Asia. The routine prevalence survey method using night thick blood smear is not sensitive enough to reflect the actual infection prevalence. In 1997-2001, only three microfilaraemic cases (of 5601 individuals screened; 0.05%) were reported in Pasir Mas, a district in Kelantan (Malaysia), which shares a border with Thailand. We therefore investigated the infection prevalence in this district by employing a sensitive and specific serological assay (Brugia-Elisa). This test is based on detection of specific IgG4 antibody against a Brugia malayi recombinant antigen. A total of 5138 children, aged 7-12 years, from 16 primary schools, were tested. Eighteen pupils in eight schools, located in five subdistricts, tested positive, giving an overall prevalence rate of 0.35%. Infection in these children is significant as they represent more recent cases. These subdistricts should be included in the national filariasis elimination programme.
    Matched MeSH terms: Antigens, Helminth*
  14. Rahmah N, Taniawati S, Shenoy RK, Lim BH, Kumaraswami V, Anuar AK, et al.
    Trans R Soc Trop Med Hyg, 2002 1 31;95(6):601-4.
    PMID: 11816429
    A total of 753 serum samples from 6 institutions in 3 countries (Malaysia, Indonesia and India) were used to evaluate an immunochromatographic rapid dipstick test, Brugia Rapid, for diagnosis of Brugia malayi infection. The samples comprised sera from 207 microfilaria-positive individuals and 546 individuals from filaria non-endemic areas. The latter consisted of 70 individuals with soil-transmitted helminth infections, 68 with other helminth infections, 238 with protozoan infections, 12 with bacterial and viral infections and 158 healthy individuals. The dipstick is prepared with a goat anti-mouse antibody control line and a B. malayi recombinant-antigen test line. First, the dipstick is dipped into a well containing diluted patient serum, thus allowing specific anti-filarial antibody in the serum to react with the recombinant antigen. Then the dipstick is placed into an adjacent well containing reconstituted anti-human IgG4-gold. After 10 min, development of 2 red-purplish lines denotes a positive result and one line indicates a negative reaction. The overall results of the evaluation showed 97% sensitivity, 99% specificity, 97% positive predictive value and 99% negative predictive value. Brugia Rapid is thus a promising diagnostic tool for detection of B. malayi infection, and would be especially useful for the brugian filariasis elimination programme.
    Matched MeSH terms: Antigens, Helminth/analysis
  15. Rahmah N, Lim BH, Khairul Anuar A, Shenoy RK, Kumaraswami V, Lokman Hakim S, et al.
    Trans R Soc Trop Med Hyg, 2001 8 9;95(3):280-4.
    PMID: 11490997
    An IgG4 ELISA based on a novel recombinant antigen was evaluated for detection of Brugia malayi infection, using 2487 sera from various institutions: 2031 samples from Universiti Sains Malaysia, 276 blinded sera from 2 other institutions in Malaysia, 140 blinded sera from India and 40 blinded sera from Thailand. These sera were from various groups of individuals, i.e., microfilaraemics, chronic patients, endemic normals, non-endemic normals and individuals with other parasitic and bacterial infections. Based on a cut-off optical density reading of 0.300, the IgG4 ELISA demonstrated specificity rates of 95.6-100%, sensitivity rates of 96-100%, positive predictive values of 75-100% and negative predictive values of 98.9-100%. These evaluation studies demonstrated the high specificity and sensitivity of this test for the detection of active B. malayi infection. Thus, the IgG4 ELISA would be very useful as a tool in diagnosis and in elimination programmes for brugian filariasis.
    Matched MeSH terms: Antigens, Helminth/blood*
  16. Noordin R, Abdullah KA, Azahri NA, Ramachandran CP
    PMID: 10928359
    Western blot analysis of infective larvae (L3) antigen of Brugia malayi were performed on 200 sera from six groups of individuals: 36 samples from B. malayi microfilaremic individuals; 10 samples from individuals with elephantiasis; 50 and 20 samples from amicrofilaremic individuals in a B. malayi endemic area with no anti-filarial IgG4 antibodies (towards microfilaria and adult worm antigens) and samples with high titres of the anti-filarial IgG4 antibodies respectively; 50 samples from non-endemic normals and 34 samples from geohelminth-infected individuals. After protein transfer, PVDF membrane strips were successively incubated with blocking solution, human sera, monoclonal anti-human IgG4 antibody-HRP and developed with luminol chemiluminescence substrate. 28/36 (78%), 1/10 (10%) and 16/20(80%) of sera from individuals with microfilariae, elephantiasis and amicrofilaremic individuals with high titers of anti-filarial IgG4 antibodies respectively recognized L3 antigenic epitopes; the dominant and consistent antigenic bands were of approximately MW 43 kDa, 14 kDa, 15 kDa and 59 kDa. The rest of the sera were unreactive. This study showed that microfilaremics may or may not mount a notable antibody response to somatic L3 antigens, thus lending evidence that antibody response to this antigen is not protective against establishment of Brugia malayi infection.
    Matched MeSH terms: Antigens, Helminth/immunology*
  17. Cheah TS, Sani RA, Chandrawathani P, Bahri S, Dahlan I
    Trop Anim Health Prod, 1999 Feb;31(1):25-31.
    PMID: 10399814
    An investigation into the epidemiology of Trypansoma evansi infection in crossbred dairy cattle was conducted for a period of 12 months on a dairy cattle farm in Penninsular Malaysia. The prevalence of parasitaemia was highest in lactating animals (13.4%), followed by those in the dry herd (8.8%), late pregnant animals (8.1%), early pregnant animals (4.7%), calves (0.3%) and heifers (0.2%). The prevalence of antigenaemia was highest in the lactating animals (54.7%), followed by that in dry animals (53.7%), heifers (51.1%), late pregnant animals (47.7%), early pregnant animals (46.5%) and calves (24.2%).
    Matched MeSH terms: Antigens, Helminth/blood
  18. Rahmah N, Anuar AK, A'shikin AN, Lim BH, Mehdi R, Abdullah B, et al.
    Biochem Biophys Res Commun, 1998 Sep 29;250(3):586-8.
    PMID: 9784388
    Western blot analyses were performed on 444 serum specimens: 40 sera from microfilaraemic individuals, 10 sera from elephantiasis patients, 24 treated individuals, 50 sera from residents of endemic areas without anti-filarial IgG4 antibodies (endemic normals), 20 sera from amicrofilaraemic individuals with high anti-filarial IgG4 antibodies, 200 sera from healthy city-dwellers (non-endemic samples), and 100 sera from soil-transmitted helminth-infected individuals. Phast electrophoresis system was used to electrophorese Brugia malayi soluble adult worm antigen on 10-15% SDS-PAGE gradient gels followed by electrophoretic transfer onto PVDF membranes. Membrane strips were then successively incubated with blocking solution, human sera, and monoclonal anti-human IgG4 antibody-HRP, with adequate washings done in between each incubation step. Luminol chemiluminescence detection was then used to develop the blots. An antigenic band with the MW of approximately 37 kDa was found to be consistently present in the Western blots of all microfilaraemic sera, all amicrofilaraemic sera with high titres of anti-filarial IgG4 antibodies, some treated patients, and some elephantiasis patients. The antigen did not occur in immunoblots of individuals with other helminthic infections, normal endemic individuals, and city dwellers. Therefore the B. malayi antigen of with the MW of approximately 37 kDa demonstrated specific reactions with sera of B. malayi-infected individuals and thus may be useful for diagnostic application.
    Matched MeSH terms: Antigens, Helminth/blood*; Antigens, Helminth/immunology
  19. Rahmah N, Anuar AK, Ariff RH, Zurainee MN, A'shikin AN, Fadzillah A, et al.
    Trop Med Int Health, 1998 Mar;3(3):184-8.
    PMID: 9593356
    OBJECTIVE: To evaluate the usefulness of antifilarial IgG4 antibody assay in detecting B. malayi infection in a filaria endemic area in Malaysia.

    METHODS: A sandwich ELISA using B. malayi soluble antigen was employed to detect antifilarial IgG4 antibodies in serum samples of 330 individuals who comprised 88 healthy individuals from nonendemic areas, 15 B. malayi microfilaraemic cases, 22 individuals with soil-transmitted helminthiases, 9 elephantiasis cases and 196 residents from a B. malayi-endemic area. An O.D. value of > 0.420 at serum dilution of 1:400 was used as the cut-off point. This cut-off point was obtained by taking the mean optical density (0.252 + 4 S.E.) of 36 negative sera which had O.D. values greater than 0.1 at serum dilution of 1:400.

    RESULTS: All 15 microfilaraemic persons were positive for antifilarial IgG4 antibody. Non-endemic normals, soil-transmitted helminth infected persons and chronic elephantiasis cases were negative for antifilarial IgG4 antibody. Of the 196 individuals from the filaria endemic area, 37 (18.8%) demonstrated presence of antifilarial IgG4 antibodies; and only eight individuals (4.1%) were positive for microfilariae. All eight microfilaraemic individuals were also positive for antifilarial IgG4 antibodies.

    CONCLUSION: Antifilarial IgG4-ELISA could detect 4.6 times more positive cases than the microfilaria detection method. With appropriate cut-off values that eliminate cross-reactivities, this serological tool is very useful for Brugia malayi prevalence surveys and diagnosis.

    Matched MeSH terms: Antigens, Helminth*
  20. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Antigens, Helminth/blood*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links