AREAS COVERED: We searched multiple databases, including PubMed, Web of Knowledge, Scopus, ACM, Embase, IEEE and Ingenta. We explored various evaluation aspects of MD and EMR to gain a better understanding of their complex integration. We reviewed numerous risk management and assessment frameworks related to MD and EMR security aspects and mitigation controls and then identified their common evaluation aspects. Our review indicated that previous evaluation frameworks assessed MD and EMR independently. To address this gap, we proposed an evaluation framework based on the sociotechnical dimensions of health information systems and risk assessment approaches for MDs to evaluate MDI-EMR integratively.
EXPERT OPINION: The emergence of MDI-EMR cyber threats requires appropriate evaluation tools to ensure the safe development and application of MDI-EMR. Consequently, our proposed framework will continue to evolve through subsequent validations and refinements. This process aims to establish its applicability in informing stakeholders of the safety level and assessing its effectiveness in mitigating risks for future improvements.
OBJECTIVES: To evaluate the psychometric properties of the translated Indonesian version of the Nursing Home Survey on Patient Safety Culture (NHSOPSC-INA).
METHODS: This study was a cross-sectional survey conducted using NHSOPSC-INA. A total of 258 participants from 20 NH in Indonesia were engaged. Participants included NH managers, caregivers, administrative staff, nurses and support staff with at least junior high school education. The SPSS 23.0 was used for descriptive data analysis and internal consistency (Cronbach's alpha) estimation. The AMOS (version 22) was used to perform confirmatory factor analysis (CFA) on the questionnaire's dimensional structure.
RESULTS: The NHSOPSC CFA test originally had 12 dimensions with 42 items and was modified to eight dimensions with 26 items in the Indonesian version. The deleted dimensions were 'Staffing' (4 items), 'Compliance with procedure' (3 items), 'Training and skills' (3 items), 'non-punitive response to mistakes' (4 items) and 'Organisational learning' (2 items). The subsequent analysis revealed an accepted model with 26 NHSOPSC-INA items (root mean square error of approximation = 0.091, comparative fit index = 0.815, Tucker-Lewis index = 0.793, CMIN = 798.488, df = 291, CMIN/Df = 2.74, GFI = 0.782, AGFI = 0.737, p
OBJECTIVE: To investigate the accuracy and safety of pedicle screws placed in adolescent idiopathic scoliosis (AIS) patients.
SUMMARY OF BACKGROUND DATA: The reported pedicle screws perforation rates for corrective AIS surgery vary widely from 1.2% to 65.0%. Knowledge regarding the safety of pedicle screws in scoliosis surgery is very important in preventing complications.
METHODS: This study investigates the accuracy and safety of pedicle screws placed in 140 AIS patients. CT scans were used to assess the perforations that were classified according to Rao et al (2002): grade 0, grade 1 (<2 mm), grade 2 (2-4 mm), and grade 3 (>4 mm). Anterior perforations were classified into grade 0, grade 1 (<4 mm), grade 2 (4-6 mm), and grade 3 (>6 mm). Grade 2 and 3 (excluding lateral grade 2 and 3 perforation over thoracic vertebrae) were considered as critical perforations.
RESULTS: A total of 2020 pedicle screws from 140 patients were analyzed. The overall total perforation rate was 20.3% (410 screws) with 8.2% (166 screws) grade 1, 2.9% (58 screws) grade 2 and 9.2% (186 screws) grade 3 perforations. Majority of the perforations was because of lateral perforation occurring over the thoracic region, as a result of application of extrapedicular screws at this region. When the lateral perforations of the thoracic region were excluded, the perforation rate was 6.4% (129 screws), grade 2, 1.4% (28 screws) and grade 3, 0.8% (16 screws). There were only two symptomatic left medial grade 2 perforations: one screw at T12 presented with postoperative iliac crest numbness and another screw at L2 presented with radicular pain that subsided with conservative treatment. There were six anterior perforations abutting the right lung, four anterior perforations abutting the aorta, two anterior perforations abutting the esophagus, and one abutting the trachea was noted.
CONCLUSION: Pedicle screws insertion in AIS has a total perforation rate of 20.3%. After exclusion of lateral thoracic perforations, the overall perforation rate was 8.6% with a critical perforation rate of 2.2% (44/2020). The rate of symptomatic screw perforation leading to radicular symptoms was 0.1%. There was no spinal cord, aortic, esophageal, or lung injuries caused by malpositioned screws in this study.
LEVEL OF EVIDENCE: 4.