Displaying publications 41 - 60 of 117 in total

Abstract:
Sort:
  1. Noordin R, Khanbabaie S, Hafiznur Yunus M, Marti H, Nickel B, Fasihi Harandi M, et al.
    Iran J Parasitol, 2020 10 22;15(3):290-298.
    PMID: 33082792 DOI: 10.18502/ijpa.v15i3.4191
    Background: Human echinococcosis is a neglected zoonotic disease distributed worldwide. It comprises cystic and alveolar forms, the former being the more prevalent disease. Imaging techniques are the first choice for diagnosis of cystic echinococcosis and serology is used as an additional diagnostic technique in doubtful cases or as the sole test in low-resource settings. Rapid diagnostic tests are useful and convenient for immunodiagnosis of cystic echinococcosis in endemic areas, where medical facilities often struggle with limited resources.

    Methods: Recently, we have developed Hyd Rapid™, an IgG4 lateral flow dipstick test using recombinant antigen B1 for detection of cystic echinococcosis. This study was performed between 2016 until 2018 at the Institute for Research in Molecular Medicine, Universiti Sains Malaysia. The diagnostic performance of Hyd Rapid™ was tested in-house and at two international laboratories in Switzerland and Iran.

    Results: The overall diagnostic sensitivity for detection of cystic and alveolar echinococcosis was 95% (56/59). Meanwhile, the diagnostic specificity, with and without exclusion of cysticercosis and fascioliasis, was 100% (n=48) and 88% (63/72), respectively.

    Conclusion: Hyd Rapid™ detected cystic echinococcosis as well as probable cases of alveolar echinococcosis. Therefore, Hyd Rapid™ showed good potential as a serological tool for echinococcosis, and merits further evaluation.

  2. Rahumatullah A, Ahmad A, Noordin R, Lai JY, Baharudeen Z, Lim TS
    Exp Parasitol, 2020 Dec;219:108029.
    PMID: 33096112 DOI: 10.1016/j.exppara.2020.108029
    Echinococcus granulosus is a worldwide zoonotic infection that causes human cystic echinococcosis (CE) or hydatid disease. The present study describes the isolation and production of a monoclonal antibody against recombinant AgB protein using the developed Human AntibodY Disease ENhanced (HAYDEN)-Filariasis library. The DNA sequences of the isolated clones were analyzed, followed by gene analysis and binding assays. Clone E1 showed a full-length sequence and represents the IgHV5-LV3 antibody gene family. The antibody protein yield was satisfactory, and it reacted specifically against rAgB. The novel E1 protein is potentially useful for the development of an antigen detection assay for CE. The ability of the Brugia malayi immune antibody library to isolate antibodies against Echinococcus granulosus antigens highlights the broad coverage of immune antibody libraries.
  3. Khan AH, Khanbabaie S, Yunus MH, Mohd Zain SN, Mohd Baharudeen Z, Sahimin N, et al.
    J Immigr Minor Health, 2020 Oct;22(5):1105-1108.
    PMID: 32445161 DOI: 10.1007/s10903-020-01029-y
    Hydatid disease is not endemic in Malaysia; however, its migrant workers originate from neighboring countries where the disease is prevalent. Thus, this study was aimed at investigating the seroprevalence of hydatid disease among the workers. A total of 479 migrant workers were screened for hydatid disease. The sociodemographic information was collected, and serum samples were tested with a rapid dipstick test for hydatid disease called Hyd Rapid™. The present study showed that 13.6% of the migrant workers were found to be seropositive for hydatid disease. The highest seroprevalence was seen among Indian workers (29.41%), followed by Myanmarese (21.43%), Bangladeshis (14.92%), Nepalese (10.68%), and Indonesian (10.66%). This is the first study that highlights the likely presence of hydatid disease among the migrant workers in Malaysia, which may be of interest to the health authorities.
  4. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
  5. Tan AA, Azman SN, Abdul Rani NR, Kua BC, Sasidharan S, Kiew LV, et al.
    Trop Biomed, 2011 Dec;28(3):620-9.
    PMID: 22433892 MyJurnal
    There is a great diversity of protein samples types and origins, therefore the optimal procedure for each sample type must be determined empirically. In order to obtain a reproducible and complete sample presentation which view as many proteins as possible on the desired 2DE gel, it is critical to perform additional sample preparation steps to improve the quality of the final results, yet without selectively losing the proteins. To address this, we developed a general method that is suitable for diverse sample types based on phenolchloroform extraction method (represented by TRI reagent). This method was found to yield good results when used to analyze human breast cancer cell line (MCF-7), Vibrio cholerae, Cryptocaryon irritans cyst and liver abscess fat tissue. These types represent cell line, bacteria, parasite cyst and pus respectively. For each type of samples, several attempts were made to methodically compare protein isolation methods using TRI-reagent Kit, EasyBlue Kit, PRO-PREP™ Protein Extraction Solution and lysis buffer. The most useful protocol allows the extraction and separation of a wide diversity of protein samples that is reproducible among repeated experiments. Our results demonstrated that the modified TRI-reagent Kit had the highest protein yield as well as the greatest number of total proteins spots count for all type of samples. Distinctive differences in spot patterns were also observed in the 2DE gel of different extraction methods used for each type of sample.
  6. Rahumatullah A, Balachandra D, Noordin R, Baharudeen Z, Lim YY, Choong YS, et al.
    Sci Rep, 2021 01 28;11(1):2502.
    PMID: 33510342 DOI: 10.1038/s41598-021-82125-3
    Antibodies have different chemical properties capable of targeting a diverse nature of antigens. Traditionally, immune antibody libraries are perceived to be disease-specific with a skewed repertoire. The complexity during the generation of a combinatorial antibody library allows for a skewed but diverse repertoire to be generated. Strongyloides stercoralis is a parasite that causes strongyloidiasis, a potentially life-threatening disease with a complex diagnosis that impedes effective control and treatment of the disease. This study describes the isolation of monoclonal antibodies against S. stercoralis NIE recombinant protein using an immune antibody phage display library derived from lymphatic filaria-infected individuals. The isolated antibody clones showed both lambda and kappa light chains gene usage, with diverse amino acid distributions. Structural analysis showed that electropositivity and the interface area could determine the binding affinity of the clones with NIE. The successful identification of S. stercoralis antibodies from the filarial immune library highlights the breadth of antibody gene diversification in an immune antibody library that can be applied for closely related infections.
  7. Kumarasamy G, Abdus Sani AA, Olivos-García A, Noordin R, Othman N
    Pathog Glob Health, 2020 09;114(6):333-342.
    PMID: 32536281 DOI: 10.1080/20477724.2020.1780402
    Amoebiasis, caused by Entamoeba histolytica, is one of the leading parasitic infections in the world. This study was aimed at profiling antigenic membrane proteins of a virulent variant of E. histolytica HM-1:IMSS. The membrane proteins were extracted using ProteoExtract® kit (Merck, Darmstadt, Germany) or conventional method, separated using OFFGEL 3100 fractionator (Agilent Technologies, Santa Clara, California), followed by SDS-PAGE and Western blot analysis. Selected antigenic membrane proteins were identified using LC-ESI-MS/MS. Subsequently, the proteins were classified according to their biological processes and predictions were made on membrane and membrane-associated proteins. When the proteins were probed with pooled sera from amoebic liver abscess (ALA) patients, 10 and 15 antigenic proteins with molecular weights 25 to 200 kDa were identified using the ProteoExtract® kit and conventional method, respectively. LC-ESI-MS/MS identified 13 antigenic proteins, and both extraction methods predicted six of them as membrane and membrane-associated proteins. The topmost biological processes which comprised of six proteins were involved in cellular processes.. These antigenic membrane proteins merit further investigations as potential candidates for vaccine studies.
  8. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
  9. Sahimin N, Yunus MH, Douadi B, Yvonne Lim AL, Noordin R, Behnke JM, et al.
    Trop Biomed, 2019 Dec 01;36(4):1014-1026.
    PMID: 33597471
    The influx of low skilled migrant workers to Malaysia from low socio-economic countries where gastrointestinal parasitic infections are prevalent has raised concerns about transmission to the local population. Three methods for detection (serology, microscopy and molecular techniques) were utilized to identify Entamoeba infections amongst the targeted cohort and determine risk factors associated with infection. Serological screening of 484 migrant workers from five working sectors in Peninsular Malaysia using IgG4 ELISA based on the rPPDK antigen showed an overall seroprevalence of 7.4% (n = 36; CL95 = 5.3-10.1%) with only one factor statistically associated with seropositivity of anti-amoebic antibodies, i.e. years of residence in Malaysia (χ2 1 = 4.007, p = 0.045). Microscopic examination of 388 faecal samples for protozoan cysts and trophozoites showed a slightly higher prevalence (11.6%; n=45; CL95: 8.4-14.8%). Meanwhile, amplification of the 16S rDNA gene detected two species i.e. Entamoeba dispar (23/388; 5.9%; CL95: 3.6-8.3%) and E. histolytica (11/388; 2.8%; CL95: 1.2-4.5%) and mixed infections with both parasites in only three samples (3/388; 0.8%; CL95: 0.2-2.2%). Entamoeba dispar infection was significantly associated with those employed in food and domestic services (χ2 4 = 12.879, p = 0.012). However, none of the factors affected the prevalence of E. histolytica infection. Despite the low prevalence of E. histolytica in faecal samples of the study cohort, the presence of this pathogenic parasite still poses potential public health risks and calls for tighter control strategies based on better availability of chemotherapeutic treatment and accessibility to appropriate health education.
  10. Vola A, Tamarozzi F, Noordin R, Yunus MH, Khanbabaie S, De Silvestri A, et al.
    Diagn Microbiol Infect Dis, 2018 Sep;92(1):31-33.
    PMID: 29776711 DOI: 10.1016/j.diagmicrobio.2018.04.007
    Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases.
  11. Saidin S, Yunus MH, Othman N, Lim YA, Mohamed Z, Zakaria NZ, et al.
    Pathog Glob Health, 2017 May;111(3):128-136.
    PMID: 28335696 DOI: 10.1080/20477724.2017.1300421
    Entamoeba histolytica infection remains a public health concern in developing countries. Early diagnosis of amoebiasis can avoid disease complications, thus this study was aimed at developing a test that can rapidly detect the parasite antigens in stool samples. Rabbits were individually immunized with recombinant pyruvate phosphate dikinase (rPPDK) and E. histolytica excretory-secretory antigens to produce polyclonal antibodies. A rapid dipstick test was produced using anti-rPPDK PAb lined on the dipstick as capture reagent and anti-EhESA PAb conjugated to colloidal gold as the detector reagent. Using E. histolytica-spiked in stool sample of a healthy individual, the detection limit of the dipstick test was found to be 1000 cells ml-1. Meanwhile when rPPDK was spiked in the stool sample, the minimum concentration detected by the dipstick test was 0.1 μg ml-1. The performances of the dipstick, commercial Techlab E. histolytica II enzyme-linked immunosorbent assays (ELISA) and real-time PCR were compared using 70 stool samples from patients infected with Entamoeba species (n = 45) and other intestinal pathogens (n = 25). When compared to real-time PCR, the diagnostic sensitivity of the dipstick for detection of E. histolytica was 65.4% (n = 17/26); while the diagnostic specificity when tested with stool samples containing other intestinal pathogens was 92% (23/25). In contrast, Techlab E. histolytica II ELISA detected 19.2% (5/26) of the E. histolytica-positive samples as compared to real-time PCR. The lateral flow dipstick test produced in this study enabled rapid detection of E. histolytica, thus it showed good potential to be further developed into a diagnostic tool for intestinal amoebiasis.
  12. Noordin R, Yunus MH, Robinson K, Won KY, Babu S, Fischer PU, et al.
    Am J Trop Med Hyg, 2018 12;99(6):1587-1590.
    PMID: 30350768 DOI: 10.4269/ajtmh.18-0566
    At the end phase of the Global Programme to Eliminate Lymphatic Filariasis, antibody testing may have a role in decision-making for bancroftian filariasis-endemic areas. This study evaluated the diagnostic performance of BLF Rapid™, a prototype immunochromatographic IgG4-based test using BmSXP recombinant protein, for detection of bancroftian filariasis. The test was evaluated using 258 serum samples, comprising 96 samples tested at Universiti Sains Malaysia (in-house) and 162 samples tested independently at three international laboratories in the USA and India, and two laboratories in Malaysia. The independent testing involved 99 samples from Wuchereria bancrofti microfilaria or antigen positive individuals and 63 samples from people who were healthy or had other infections. The in-house evaluation showed 100% diagnostic sensitivity and specificity. The independent evaluations showed a diagnostic sensitivity of 84-100% and 100% specificity (excluding non-lymphatic filarial infections). BLF Rapid has potential as a surveillance diagnostic tool to make "Transmission Assessment Survey"-stopping decisions and conduct post-elimination surveillance.
  13. Ng YL, Olivos-García A, Lim TK, Noordin R, Lin Q, Othman N
    Am J Trop Med Hyg, 2018 12;99(6):1518-1529.
    PMID: 30298805 DOI: 10.4269/ajtmh.18-0415
    Entamoeba histolytica is a protozoan parasite that causes amebiasis and poses a significant health risk for populations in endemic areas. The molecular mechanisms involved in the pathogenesis and regulation of the parasite are not well characterized. We aimed to identify and quantify the differentially abundant membrane proteins by comparing the membrane proteins of virulent and avirulent variants of E. histolytica HM-1:IMSS, and to investigate the potential associations among the differentially abundant membrane proteins. We performed quantitative proteomics analysis using isobaric tags for relative and absolute quantitation labeling, in combination with two mass spectrometry instruments, that is, nano-liquid chromatography (nanoLC)-matrix-assisted laser desorption/ionization-mass spectrometry/mass spectrometry and nanoLC-electrospray ionization tandem mass spectrometry. Overall, 37 membrane proteins were found to be differentially abundant, whereby 19 and 18 membrane proteins of the virulent variant of E. histolytica increased and decreased in abundance, respectively. Proteins that were differentially abundant include Rho family GTPase, calreticulin, a 70-kDa heat shock protein, and hypothetical proteins. Analysis by Protein ANalysis THrough Evolutionary Relationships database revealed that the differentially abundant membrane proteins were mainly involved in catalytic activities (29.7%) and metabolic processes (32.4%). Differentially abundant membrane proteins that were found to be involved mainly in the catalytic activities and the metabolic processes were highlighted together with their putative roles in relation to the virulence. Further investigations should be performed to elucidate the roles of these proteins in E. histolytica pathogenesis.
  14. Ujang J, Sani AAA, Lim BH, Noordin R, Othman N
    Proteomics, 2018 12;18(23):e1700397.
    PMID: 30284757 DOI: 10.1002/pmic.201700397
    Entamoeba histolytica membrane proteins are important players toward the pathogenesis of amoebiasis, but the roles of most of the proteins are not fully understood. Since efficient protein extraction method is crucial for a successful MS analysis, three extractions methods are evaluated for the use in studying the membrane proteome of E. histolytica: Two commercial kits (ProteoExtract from Calbiochem and ProteoPrep from Sigma), and a conventional laboratory method. The results show that ProteoExtract and the conventional method gave higher protein yields compared to ProteoPrep. LC-ESI-MS/MS identifies 456, 482, and 551 membrane fraction proteins extracted using ProteoExtract, ProteoPrep, and a conventional method, respectively. In silico analysis predicts 108 (21%), 235 (45%), and 177 (34%) membrane proteins from the extracts of ProteoExtract, ProteoPrep, and the conventional method, respectively. Furthermore, analysis of the cytosolic and membrane fractions shows the highest selectivity of the membrane proteins using the ProteoPrep extraction kit. Overall, this study reports 828 E. histolytica membrane fraction proteins that include 249 predicted membrane proteins. The data are available via ProteomeXchange with identifier PXD010171.
  15. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
  16. Abdo AIK, Ngoh YY, Lew MH, Dass SA, Rahumatullah A, Noordin R, et al.
    Biotechnol Appl Biochem, 2022 Feb;69(1):70-76.
    PMID: 33258152 DOI: 10.1002/bab.2082
    Lymphatic filariasis is a neglected parasitic disease that affects millions in tropical and subtropical countries and is caused by Wuchereria and Brugia species. Specific and sensitive detection methods are essential in mapping infected areas where rapid tests are needed to cover underdeveloped and remote regions, which facilitates eliminating the disease as a public health problem. A few commercialized rapid tests based on antigen or antibody detection are available, but the former only detects infection by Wuchereria species and cross-reacts with nonlymphatic filaria, whereas antibody detection might provide positive results of previous infection. Here, we report the production of three different recombinant immunoglobulin gamma (IgG)1 antibodies based on scFvs previously generated via human antibody phage display technology, that is, anti-BmR1 clone 4, anti-BmXSP clone 5B, and anti-BmXSP clone 2H2. The scFv sequences were cloned into a pCMV-IgG1 vector, then transfected into a HEK293F cell line. The generated antibodies were found to be able to bind to their respective targets even at relatively low concentration. Conjugation of Fc to scFv induces binder stability and provides multiple labeling sites for probes and signaling molecules that can be used in rapid tests.
  17. Berizi M, Babaie J, Fard-Esfahani P, Enshaeieh M, Noordin R, Saadatnia G, et al.
    Iran J Parasitol, 2022 1 28;16(4):621-630.
    PMID: 35082891 DOI: 10.18502/ijpa.v16i4.7875
    Background: Toxoplasmosis is a worldwide-distributed infection that can cause serious diseases, mainly in congenitally infected and immunodeficient individuals. PCR assays play an indispensable role in the detection of Toxoplasma gondii in different biological samples.

    Methods: This study was conducted in the Parasitology Department at Pasteur Institute of Iran (Tehran) during 2016-2018. We designed a highly sensitive quantitative real-time PCR (RT-qPCR) targeted REP-529, a noncoding repetitive DNA. We cloned the amplicon in a plasmid (pTZREP-529) and used it to generate the standard curve. The Toxoplasma RT-qPCR characteristics, i.e., detection limit, specificity, linear dynamic range, linearity, intra-, and inter-assay precisions, were determined. The detection limit of the assay was one plasmid copy number (PCN) per reaction (about 0.004 T. gondii genome), and the linear dynamic range was equal to 6 logs (1× 101 to 1× 107 PCN per reaction).

    Results: The assay showed no signal when genomic DNA of Plasmodium falciparum, Leishmania major, and Trichomonas vaginallis were used. The standard curve was drawn using dilutions of pTZREP-529 plasmid spiked with genomic DNA from a mouse brain, and test characteristics were shown unaffected. Applying the Toxoplasma RT-qPCR, we showed brain cysts were significantly decreased in mice vaccinated with GRA2 antigen of Toxoplasma formulated in Monophosphoryl Lipid A (MPL) adjuvant.

    Conclusion: We have developed a quantitative, specific, and highly sensitive PCR for detecting T. gondii in biological samples.

  18. Noordin R, Osman E, Anuar NS, Juri NM, Rahumatullah A, Ahmad Hilmi NA
    Am J Trop Med Hyg, 2021 08 30;105(5):1214-1217.
    PMID: 34460427 DOI: 10.4269/ajtmh.21-0674
    A lateral flow rapid test for strongyloidiasis will greatly facilitate the control and elimination of the disease. Previously SsRapid prototype rapid test showed high diagnostic specificity to detect Strongyloides infection, determined using non-Strongyloides sera negative by IgG-ELISAs. Since high specificity is crucial before a test is used for public health control activities, further validation of its specificity is needed. Also, it needs to be ascertained whether non-Strongyloides sera positive by IgG-ELISAs and SsRapid are truly positive for Strongyloides or are cases of cross-reactivity. We performed 84 rapid tests (two types of dipsticks and cassettes) using 34 serum samples. They were divided into four groups based on Strongyloides infection and coinfection with other parasites and the availability of recombinant proteins and rapid tests for the latter. Sera was adsorbed using polystyrene microspheres beads separately coated with four recombinant parasite proteins. The small sample size is a limitation of this study; however, the overall results showed that the sera adsorption procedure was successful, and the SsRapid test is specific.
  19. Omar N, Hamidon NH, Yunus MH, Noordin R, Choong YS, Lim TS
    Biotechnol Appl Biochem, 2018 May;65(3):346-354.
    PMID: 28833498 DOI: 10.1002/bab.1591
    Phage display has been applied successfully as a tool for the generation of monoclonal antibodies (mAbs). Naive antibody libraries are unique as they are able to overcome several limitations associated with conventional mAb generation methods like the hybridoma technology. Here, we performed an in vitro selection and generation of Fab antibodies against Brugia malayi SXP protein (BmSXP), a recombinant antigen for the detection of lymphatic filariasis. We developed a naïve multi ethnic Fab antibody library with an estimated diversity of 2.99 × 109 . The antibody library was used to screen for mAbs against BmSXP recombinant antigen. Soluble monoclonal Fab antibodies against BmSXP were successfully isolated from the naïve library. The Fab antibodies obtained were expressed and analyzed to show its binding capability. The diversity obtained from a pool of donors from various ethnic groups allowed for a diverse antibody library to be generated. The mAbs obtained were also functional in soluble form, which makes it useful for further downstream applications. We believe that the Fab mAbs are valuable for further studies and could also contribute to improvements in the diagnosis of filariasis.
  20. Arifin N, Yunus MH, Nolan TJ, Lok JB, Noordin R
    Am J Trop Med Hyg, 2018 04;98(4):1165-1170.
    PMID: 29436335 DOI: 10.4269/ajtmh.17-0697
    Strongyloides stercoralis is a human parasite that can cause a long-term infection. In immunosuppressed patients, strongyloidiasis may be fatal when there is overwhelming autoinfection resulting in the migration of large numbers of larvae through many organs. Definitive diagnosis is still a challenge, and a combination of symptoms, microscopic identification, and serology test results are often used to arrive at a clinical decision. However, intermittent larval excretion, low parasite burden, and occult infections are challenges with parasitological diagnosis of infection with S. stercoralis. Meanwhile, serologic tests using immunoglobulin G and parasite antigen extract have problems of cross-reactivity with other helminthic infections. Recombinant antigen-based serodiagnosis is a good alternative to overcome the laboratory diagnostic issues. Herein, we report on the isolation of cDNA clone encoding an antigen of potential diagnostic value identified from immunoscreening of a S. stercoralis cDNA library. The translated protein had highest similarity to Strongyloides ratti immunoglobulin-binding protein 1. The recombinant antigen produced, rSs1a, was assessed using western blot and enzyme-linked immunosorbent assay. The latter showed 96% diagnostic sensitivity and 93% specificity; thus, rSs1a has good potential for use in serodiagnosis of human strongyloidiasis.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links