Displaying publications 41 - 60 of 135 in total

Abstract:
Sort:
  1. Alyahyawi A, Alanazi AH, Almurayshid M, Alshahri S, Almeshari M, Bradley DA
    Appl Radiat Isot, 2021 Dec;178:109953.
    PMID: 34560514 DOI: 10.1016/j.apradiso.2021.109953
    In respect of radiation exposure assessments, thermoluminescent dosimeters (TLD) represent a notable and important subset of passive detector technology, gaining widespread use over a period of many decades, not least for medical applications. TLDs are available in a range of physical and chemical forms, in particular the popularity of phosphor-based commercial products arising from features that include availability down to low mm dimensions, soft-tissue equivalence in some cases, and relatively low TL fading. Novel doped silica glass TL material fabricated as fibres also offer favourable responses, recent developments in co-doping leading to their ability to also provide for diagnostic radiology applications, adding to the attractive features of being impervious to water, of good sensitivity, and generally offering wide dynamic range. Thus said, doping and fibre fabrication involve relatively high costs. Accordingly, herein exploratory investigations are made of the cost-effective colourless silica-based glass medium from which marbles are made, reduced into chip form for ease of application, examining sensitivity to dose. In particular, the study focuses on the computerised tomography clinical application regime, 80- to 140 kVp, with excellent response being shown for doses within the range 2- to 50 mGy.
  2. Alnaaimi M, Sulieman A, Tamam N, Alkhorayef M, Alduaij M, Mohammedzein T, et al.
    Appl Radiat Isot, 2021 Dec;178:109965.
    PMID: 34688024 DOI: 10.1016/j.apradiso.2021.109965
    The positron emitters (18F-Sodium Fluoride (NaF)) and X-rays used in Positron emission tomography (PET) combined with computed tomography (PET/CT) imaging have a high radiation dose, which results in a high patient dose. The present research intends to determine the radiation dose and risks associated with PET/CT- 18F-Sodium fluoride examinations in patients. The 18F-NaF PET/CT was used to investigate the doses of 86 patients. Patient exposure parameters and ImPACT software were used to calculate mean effective doses. The administered activity of 185 MBq (5.0 mCi) per procedure has a mean and range based on the patient's BMI (BMI). The range of patient effective doses per procedure was found to be 4-10 mSv, with a radiation risk of 1 × 10-5 per procedure. Patient doses are determined by the patient's size, scanner type, imaging protocol, and reconstruction method. For further dose reduction, proper justification and radiation dose optimization is required.
  3. Tamam N, Sulieman A, Omer H, Toufig H, Alsaadi M, Salah H, et al.
    Appl Radiat Isot, 2022 Dec;190:110452.
    PMID: 36183658 DOI: 10.1016/j.apradiso.2022.110452
    CT scanning deliver much higher radiation doses than planar radiological procedures, which puts patients to high risks. This study measures and evaluates patient doses during chest and abdomen computed tomography procedures. Particular attention is given to measuring the dose to the equivalent breast (mSv) and to estimate the associated risks of breast cancer to young female patients (15-35 years). Data was obtained from standard examinations from three hospitals. The measured values of CT dose indexes, CTDI (mGy) as well as exposure-related parameters were used for assessment. Breast and effective doses were extrapolated using a software. The results showed remarkable variations of the mean organ equivalent doses for similar CT examinations in the studied hospitals. This could be attributed to the variation in CT scanning imaging technique, and clinical indications. The average effective dose to the chest was 7.9 mSv (2.3-47.0 mSv) and for the abdomen the mean dose was 6.6 mSv, ranging from (3.3-27 mSv). The breast received equivalent doses from chest and abdomen procedures as follows: 10.2 (1.6-33 mSv) and 10.1(2.3-19 mS) Sv respectively. Each procedure yielded high risks of breast cancer for young females. Implementation of accurate referral criteria is recommended to avoid unnecessary breast radiation exposure.
  4. Begum M, Rahman AKMM, Abdul-Rashid HA, Yusoff Z, Mat Nawi SN, Khandaker MU, et al.
    Appl Radiat Isot, 2021 Aug;174:109771.
    PMID: 34048992 DOI: 10.1016/j.apradiso.2021.109771
    Present study concerns the key thermoluminescence (TL) properties of photonic crystal fibres (PCFs), seeking development of alternatively structured TL materials that are able to offer a advantages over existing passive dosimeters. In terms of their internal structure and light guiding properties the PCFs, collapsed and structured, differ significantly from that of conventional optical fibres. To investigate the dosimetric parameters of the PCFs use was made of a linear accelerator producing a 6 MV photon beam, delivering doses ranging from 0.5 Gy to 8 Gy. The parameters studied included TL response, linearity index, glow curves, relative sensitivity and TL signal fading, the results being compared against those obtained using TLD-100 chips. At 4 Gy photon dose the Ge-doped collapsed PCFs were found to provide a response 27 × that of structured PCF, also giving a TL yield similar to that of standard TLD-100 chips. Over post-irradiation periods of 15 and 30 days collapsed PCF TL signal fading were 8% and 17% respectively, with corresponding values of 37% and 64% for the structured PCF. Trapping parameters including the order of kinetics (b), activation energy (E) and frequency factor (s-1) were assessed with Chen's peak shape method. Lifetime of trapping centre was found to be (2.36 E+03) s and (9.03 E +01) s regarding the collapsed and structured PCF respectively with 6 Gy of photon beam. For the Ge-doped collapsed PCF, the high TL yield, sensitivity and low fading provide the basis of a highly promising system of TLD for radiotherapy applications.
  5. Oresegun A, Tarif ZH, Ghassan L, Zin H, Abdul-Rashid HA, Bradley DA
    Appl Radiat Isot, 2021 Oct;176:109812.
    PMID: 34166948 DOI: 10.1016/j.apradiso.2021.109812
    Investigation has been made of the radioluminescence dose response of Ge-doped silica flat and cylindrical fibers subjected to 6 and 10 MV photon beams. The fibers have been custom fabricated, obtaining Ge dopant concentrations of 6 and 10 mol%, subsequently cut into 20 mm lengths. Each sample has been exposed under a set of similar conditions, with use made of a fixed field size and source to surface distance (SSD). Investigation of dosimetric performance has involved radioluminescence linearity, dose-rate dependence, energy dependence, and reproducibility. Mass for mass, the 6 mol% Ge-doped samples provided the greater radioluminescence yield, with both flat and cylindrical fibers responding linearly to the absorbed dose. Further found has been that the cylindrical fibers provided a yield some 38% greater than that of the flat fibers. At 6 MV, the cylindrical fibers were also found to exhibit repeatability variation of <1%, superior to that of the flat fibers, offering strong potential for use in real-time dosimetry applications.
  6. Nazeri AAZA, Sani SFA, Ung NM, Almugren KS, Alkallas FH, Bradley DA
    Appl Radiat Isot, 2021 Oct;176:109814.
    PMID: 34175543 DOI: 10.1016/j.apradiso.2021.109814
    Brachytherapy is commonly used in treatment of cervical, prostate, breast and skin cancers, also for oral cancers, typically via the application of sealed radioactive sources that are inserted within or alongside the area to be treated. A particular aim of the various brachytherapy techniques is to accurately transfer to the targeted tumour the largest possible dose, at the same time minimizing dose to the surrounding normal tissue, including organs at risk. The dose fall-off with distance from the sources is steep, the dose gradient representing a prime factor in determining the dose distribution, also representing a challenge to the conduct of measurements around sources. Amorphous borosilicate glass (B2O3) in the form of microscope cover slips is recognized to offer a practicable system for such thermoluminescence dosimetry (TLD), providing for high-spatial resolution (down to 
  7. Alyahyawi A, Jupp T, Alkhorayef M, Bradley DA
    Appl Radiat Isot, 2018 Aug;138:45-49.
    PMID: 28780202 DOI: 10.1016/j.apradiso.2017.07.011
    In the modern clinical practice of diagnostic radiology there is a growing demand for radiation dosimetry, it also being recognized that with increasing use of X-ray examinations additional population dose will result, accompanied by an additional albeit low potential for genetic consequences. At the doses typical of diagnostic radiology there is also a low statistical risk for cancer induction; in adhering to best practice, to be also implied is a low but non-negligible potential for deterministic sensitive organ responses, including in regard to the skin and eyes. Risk reduction is important, in line with the principle of ALARP, both in regard to staff and patients alike; for the latter modern practice is usually guided by Dose Reference Levels (DRL) while for the former and members of the public, legislated controls (supported by safe working practices) pertain. As such, effective, reliable and accurate means of dosimetry are required in support of these actions. Recent studies have shown that Ge-doped-silica glass fibres offer several advantages over the well-established phosphor-based TL dosimeters (TLD), including excellent sensitivity at diagnostic doses as demonstrated herein, low fading, good reproducibility and re-usability, as well as representing a water impervious, robust dosimetric system. In addition, these silica-based fibres show good linearity over a wide dynamic range of dose and dose-rate and are directionally independent. In the present study, we investigate tailor made doped-silica glass thermoluminescence (TL) for applications in medical diagnostic imaging dosimetry. The aim is to develop a dosimeter of sensitivity greater than that of the commonly used LiF (Mg,Ti) phosphor. We examine the ability of such doped glass media to detect the typically low levels of radiation in diagnostic applications (from fractions of a mGy through to several mGy or more), including, mammography and dental radiology, use being made of x-ray tubes located at the Royal Surrey County Hospital. We further examine dose-linearity, energy response and fading.
  8. Salah H, Tamam N, Rabbaa M, Abuljoud M, Zailae A, Alkhorayef, et al.
    Appl Radiat Isot, 2023 Feb;192:110548.
    PMID: 36527854 DOI: 10.1016/j.apradiso.2022.110548
    Computed tomography coronary angiography (CTCA) has generated tremendous interest over the past 20 years by using multidetector computed tomography (MDCT) because of its high diagnostic accuracy and efficacy in assessing patients with coronary artery disease. This technique is related to high radiation doses, which has raised serious concerns in the literature. Effective dose (E, mSv) may be a single parameter meant to reflect the relative risk from radiation exposure. Therefore, it is necessary to calculate this quantity to point to relative radiation risk. The objectives of this study are to evaluate patients' exposure during diagnostic CCTA procedures and to estimate the risks. Seven hundred ninety patients were estimated during three successive years. The patient's exposure was estimated based on a CT device's delivered radiation dose (Siemens Somatom Sensation 64 (64-MDCT)). The participating physicians obtained the parameters relevant to the radiation dose from the scan protocol generated by the CT system after each CCTA study. The parameters included the volume CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy × cm). The mean and range of CTDIvol (mGy) and DLP (mGy × cm) for three respective year was (2018):10.8 (1.14-77.7) and 2369.8 ± 1231.4 (290.4-6188.9), (2019): 13.82 (1.13-348.5), and 2180.5 (501.8-9534.5) and (2020) 10.9 (0.7-52.9) and 1877.3 (149.4-5011.1), respectively. Patients' effective doses were higher compared to previous studies. Therefore, the CT acquisition parameter optimization is vital to reduce the dose to its minimal value.
  9. Salah H, Rabbaa M, Abuljoud M, Babikir E, Alkhorayef M, Tamam N, et al.
    Appl Radiat Isot, 2023 Feb;192:110610.
    PMID: 36525913 DOI: 10.1016/j.apradiso.2022.110610
    In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
  10. Sulieman A, Salah H, Rabbaa M, Abuljoud M, Alkhorayef M, Tahir D, et al.
    Appl Radiat Isot, 2023 Mar;193:110626.
    PMID: 36640699 DOI: 10.1016/j.apradiso.2022.110626
    Breast cancer is a common malignancy for females (25% of female cancers) and also has low incidence in males. It was estimated that 1% of all breast malignancies occur in males with mortality rate about 20%, with annual increase in incidence. Risk factors include age, family history, exposure to ionizing radiation and high estrogen and low of androgens hormones level. Diagnosis and screening are challenging due to limiting effectiveness of breast cancer screening. Therefore, patients may expose to ionizing radiation that may contribute in breast cancer incidence in males. In literature, limited studies were published regarding radiation exposure for males during mammography. The objective of this research is to quantify patient doses during male mammogram and to estimate the projected radiogenic risk during the procedure. In total, 42 male patients were undergone mammogram for breast cancer diagnosis during two consecutive years. The mean and range of patient age (years) is 45 (23-80). The mean and standard deviation (SD) of the peak tube potential and tube current time product are 28.64 ± 2. and 149 ± 35.1, respectively. The mean, and range of patients' entrance surface air kerma (ESAK, mGy) per single breast procedure was 5.3 (0.47-27.5). Male patient's received comparable radiation dose per mammogram compared to female procedures. With increasing incidence of male breast cancer, proper guidelines are necessary for the mammographic procedure are necessary to reduce unnecessary radiation doses and radiogenic risk.
  11. Bushra A, Sulieman A, Edam A, Tamam N, Babikir E, Alrihaima N, et al.
    Appl Radiat Isot, 2023 Mar;193:110627.
    PMID: 36584412 DOI: 10.1016/j.apradiso.2022.110627
    Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.
  12. Khandaker MU, Nawi SNM, Lam SE, Sani SFA, Islam MA, Islam MA, et al.
    Appl Radiat Isot, 2023 Jun;196:110771.
    PMID: 36933313 DOI: 10.1016/j.apradiso.2023.110771
    Thermoluminescence (TL) materials have a broad variety of uses in various fields, such as clinical research, individual dosimetry, and environmental dosimetry, amongst others. However, the use of individual neutron dosimetry has been developing more aggressively lately. In this regard, present study establishes a relationship between the neutron dosage and the optical property changes of graphite-rich materials caused by high doses of neutron radiation. This has been done with the intention of developing a novel, graphite-based radiation dosimeter. Herein, the TL yield of commercially graphite-rich materials (i.e. graphite sheet, 2B and HB grade pencils) irradiated by neutron radiation with doses ranging from 250 Gy to 1500 Gy has been investigated. The samples were bombarded with thermal neutrons as well as a negligible amount of gamma rays, from the nuclear reactor TRIGA-II installed at the Bangladesh Atomic Energy Commission. The shape of the glow curves was observed to be independent of the given dosage, with the predominant TL dosimetric peak maintained within the region of 163 °C-168 °C for each sample. By studying the glow curves of the irradiated samples, some of the most well theoretical models and techniques were used to compute the kinetic parameters such as the order of kinetics (b), activation energy (E) or trap depth, frequency factor (s) or escape probability, and trap lifetime (τ). All of the samples were found to have a good linear response over the whole dosage range, with 2B grade of polymer pencil lead graphite (PPLGs) demonstrating a higher level of sensitivity than both HB grade and graphite sheet (GS) samples. Additionally, the level of sensitivity shown by each of them is highest at the lowest dosage that was given, and it decreases as the dose increases. Importantly, the phenomenon of dose-dependent structural modifications and internal annealing of defects has been observed by assessing the area of deconvoluted micro-Raman spectra of graphite-rich materials in high-frequency areas. This trend is consistent with the cyclical pattern reported in the intensity ratio of defect and graphite modes in previously investigated carbon-rich media. Such recurrent occurrences suggest the idea of employing Raman microspectroscopy as a radiation damage study tool for carbonaceous materials. The excellent responses of the key TL properties of the 2B grade pencil demonstrate its usefulness as a passive radiation dosimeter. As a consequence, the findings suggest that graphite-rich materials have the potential to be useful as a low-cost passive radiation dosimeter, with applications in radiotherapy and manufacturing.
  13. Sulieman A, Mahgoub O, Salah H, Tamam N, Taha A, Dawood S, et al.
    Appl Radiat Isot, 2023 Dec;202:111071.
    PMID: 37871398 DOI: 10.1016/j.apradiso.2023.111071
    Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.
  14. Kuan JW, Law CS, Wong XQ, Ko CT, Awang ZH, Chew LP, et al.
    Appl Radiat Isot, 2016 Oct;116:13-21.
    PMID: 27472826 DOI: 10.1016/j.apradiso.2016.07.016
    Radioimmunotherapy is an established treatment modality in Non-Hodgkin's lymphoma. The only two commercially available radioimmunotherapies - (90)Y-ibritumomab tiuxetan is expensive and (131)I-tositumomab has been discontinued from commercial production. In resource limited environment, self-labelling (131)I-rituximab might be the only viable practical option. We reported our pioneer experience in Malaysia on self-labelling (131)I-rituximab, substituting autologous haematopoietic stem cell transplantation (HSCT) and a patient, the first reported case, received high dose (131)I-rituximab (6000MBq/163mCi) combined with BEAM conditioning for autologous HSCT.
  15. Ashraf A, Saion E, Gharibshahi E, Kamari HM, Kong YC, Hamzah MS, et al.
    Appl Radiat Isot, 2016 Jan;107:17-23.
    PMID: 26405840 DOI: 10.1016/j.apradiso.2015.09.004
    A study was carried out on the concentration of REEs (Dy, Sm, Eu,Yb, Lu, La and Ce) that are present in the core marine sediments of East Malaysia from three locations at South China Sea and one location each at Sulu Sea and Sulawesi Sea. The sediment samples were collected at a depth of between 49 and 109 m, dried, and crushed to powdery form. The entire core sediments prepared for Instrumental Neutron Activation Analysis (INAA) were weighted approximately 0.0500 g to 0.1000 g for short irradiation and 0.1500 g to 0.2000 g for long irradiation. The samples were irradiated with a thermal neutron flux of 4.0×10(12) cm(-2) s(-1) in a TRIGA Mark II research reactor operated at 750 kW. Blank samples and standard reference materials SL-1 were also irradiated for calibration and quality control purposes. It was found that the concentration of REEs varies in the range from 0.11 to 36.84 mg/kg. The chondrite-normalized REEs for different stations suggest that all the REEs are from similar origins. There was no significant REEs contamination as the enrichment factors normalized for Fe fall in the range of 0.42-2.82.
  16. Ashraf A, Saion E, Gharibshahi E, Kamari HM, Yap CK, Hamzah MS, et al.
    Appl Radiat Isot, 2017 Apr;122:96-105.
    PMID: 28129589 DOI: 10.1016/j.apradiso.2017.01.006
    A study was carried out on the distribution and enrichment of trace elements in the core marine sediments of East Malaysia from three stations at South China Sea and one station each at Sulu Sea and Sulawesi Sea. Five stations of sediment cores were recovered and the vertical concentration profiles of six elements namely Br, Cs, Hf, Rb, Ta, and V were determined using the instrumental neutron activation analysis. The enrichment factor, geoaccumulation index and the modified degree of contamination were used to calculate the anthropogenic and pollution status of the elements in the samples. Except for Cs and Hf, which by the enrichment factor are categorized from minimum enrichment to moderate enrichment in all stations and for V and Rb in Sulu Sea and Sulawesi Sea, which are categorized minimum enrichment, other elements are found to be no enrichment at all stations. The geoaccumulation index of Hf in one station shows moderately polluted and for other elements are unpolluted. However, the modified degree values of all samples are less than 1, suggesting very low contamination of elements found in all the stations.
  17. Sadiq Aliyu A, Musa Y, Liman MS, Abba HT, Chaanda MS, Ngene NC, et al.
    Appl Radiat Isot, 2018 Jan;131:36-40.
    PMID: 29107886 DOI: 10.1016/j.apradiso.2017.10.046
    The Keffi area hosts abundant pegmatite bodies as a result of the surrounding granitic intrusions. Keffi is part of areas that are geologically classified as North Central Basement Complex. Data on the mineralogy and mineralogical zonation of the Keffi pegmatite are scanty. Hence the need to understand the geology and mineralogical zonation of Keffi pegmatites especially at different depth profiles is relevant as a study of the elemental composition of the pegmatite is essential for the estimation of its economic viability. Here, the relative standardization method of instrumental neutron activation analysis (INAA) has been used to investigate the vertical deviations of the elemental concentrations of rare earth elements (REEs) at different depth profile of Keffi pegmatite. This study adopted the following metrics in investigating the vertical variations of REEs concentrations. Namely, the total contents of rare earth elements (∑REE); ratio of light to heavy rare earth elements (LREE/HREE), which defines the enrichment or depletion of REEs; europium anomaly (Eu/Sm); La/Lu ratio relative to chondritic meteorites. The study showed no significant variations in the total content of rare elements between the vertical depth profiles (100-250m). However, higher total concentrations of REEs (~ 92.65ppm) were recorded at the upper depth of the pegmatite and the europium anomaly was consistently negative at all the depth profiles suggesting that the Keffi pegmatite is enriched with light REEs.
  18. Gharibshahi E, Saion E, Ashraf A, Gharibshahi L
    Appl Radiat Isot, 2017 Dec;130:211-217.
    PMID: 29028581 DOI: 10.1016/j.apradiso.2017.09.012
    Gamma radiolytic synthesis was used to produce size-controlled spherical platinum nanoparticles from an aqueous solution containing platinum tetraammine and polyvinyl pyrrolidone. The structural characterizations were performed using X-ray diffraction, and transmission electron microscopy. The transmission electron microscopy was used to determine the average particle diameter, which decreased from 4.4nm at 80kGy to 2.8nm at 120kGy. The UV-visible absorption spectrum was measured and found that platinum nanoparticles exhibit two steady absorption maxima in UV regions due to plasmonic excitation of conduction electrons, which blue shifted to lower wavelengths with a decrease in particle size. We consider the conduction electrons of platinum nanoparticles to follow Thomas-Fermi-Dirac-Weizsacker atomic model that they are not entirely free but weakly bounded to particles at lower-energy states {n = 5, l = 2 or 5d} and {n = 6, l = 0 or 6s}, which upon receiving UV photon energy the electrons make intra-band quantum excitations to higher-energy states allowed by the principles of quantum number that results the absorption maxima. We found an excellent agreement between the experimental and theoretical results, which suggest that the optical absorption of metal nanoparticles could be fundamentally described by a quantum mechanical interpretation, which could be more relevant to photo-catalysis and heterogeneous catalysis.
  19. Omar M, Ali HM, Abu MP, Kontol KM, Ahmad Z, Ahmad SH, et al.
    Appl Radiat Isot, 2004 May;60(5):779-82.
    PMID: 15082059
    Radium concentrations in 470 samples of the various types of waste from oil and gas industries were analysed using gamma spectrometers. The results showed that the radium concentration varied within a wide range. The highest mean 226Ra and 228Ra concentrations of 114,300 and 130,120 Bq/kg, respectively, were measured in scales. Overall, 75% of the waste, mostly sludge and extraction residue lies within the normal range of radium concentration in soils of Malaysia. However, some platform sludge can have radium concentration up to 560 Bq/kg.
  20. Elias MS, Ibrahim S, Samuding K, Kantasamy N, Rahman SA, Hashim A
    Appl Radiat Isot, 2019 Sep;151:116-123.
    PMID: 31174051 DOI: 10.1016/j.apradiso.2019.05.038
    A study was carried out to determine the concentrations of rare earth elements (REEs) in Linggi river sediments collected from 113 sampling locations. The sediment analysis was performed by Neutron activation analysis (NAA) and Inductively coupled plasma - mass spectrometry (ICP-MS). The results of Linggi river sediment were normalized to "recent" reference shale values. The means of total concentrations of REEs (ΣREE), light REEs (ΣLREE) and heavy REEs (ΣHREE) in Linggi sediment were 241.2, 219.2, and 22.0 mg/kg, respectively, which indicates enrichment compared to ΣREE, ΣLREE and ΣHREE reference shale values. Results obtained from enrichment factors (EF) show no enrichment to moderate enrichment of Linggi sediments, indicating the sources of REEs pollution originated from natural and land-based activities. A similar pattern was observed by comparing the REEs values of Linggi sediments to other references shale values. Ce (δCe) and Eu (δEu) anomalies indicate Linggi sediments showed positive anomaly of Ce whilst negative anomaly of Eu.