Displaying publications 41 - 46 of 46 in total

Abstract:
Sort:
  1. Sulaiman AH, Husain R, Seluakumaran K
    Eur Arch Otorhinolaryngol, 2014 Jun;271(6):1463-70.
    PMID: 23812554 DOI: 10.1007/s00405-013-2612-z
    Although sound exposure from personal listening devices (PLDs) could potentially lead to noise-induced hearing loss (NIHL), the actual hearing risk associated with the use of these devices is still unclear. In this study, early hearing effects related to PLD usage were evaluated in 35 young adult PLD users (listening for >1 h/day, at >50% of the maximum volume setting of their devices) and their age- and sex-matched controls using a combination of conventional and extended high-frequency audiometry as well as transient-evoked otoacoustic emission (TEOAE) and distortion product of otoacoustic emission (DPOAE) measurements. The mean listening duration of the PLD users was 2.7 ± 1.0 h/day while their estimated average listening volume was 81.3 ± 9.0 dBA (free-field corrected). Typical signs of NIHL were not detected in the audiogram of PLD users and their audiometric thresholds at most of the conventional test frequencies (0.25-8 kHz) were comparable with those obtained from controls. However, compared with the controls, mean hearing thresholds of PLD users at many of the extended high-frequencies (9-16 kHz) were significantly higher. In addition, TEOAE and DPOAE amplitudes in users were reduced compared with controls. The deterioration of extended high-frequency thresholds and the decrease in DPOAE amplitudes were more evident in the users' right ears. These results indicate the presence of an early stage of hearing damage in the PLD user group. Preventive steps should be taken as the initial hearing damage in these users could eventually progress into permanent NIHL after many years of PLD use.
    Matched MeSH terms: Audiometry, Pure-Tone
  2. Tang IP, Prepageran N, Ong CA, Puraviappan P
    J Laryngol Otol, 2010 Aug;124(8):913-5.
    PMID: 20426886 DOI: 10.1017/S0022215110000265
    To demonstrate the different clinical presentations of tuberculous otitis media and the management of selected cases.
    Matched MeSH terms: Audiometry, Pure-Tone
  3. Toh, Teck Hock, Nurhilda Abdullah, Chua, Soh Yian, Muhamad Rais Abdullah, Islia Nahazatul, Chieng, Lee Ling
    Int J Public Health Res, 2011;1(2):66-71.
    MyJurnal
    Introduction Special Olympics (SO) Inc. is an organization for people with intellectual disability (ID) to actively engaging in Olympic-type sport and participating in competition. Special Olympic Inc. provides Healthy Athletes Programme (HAP®) in screening and providing health education to Special Olympic Athletes. Objective To study the body mass index (BMI), blood pressure (BP), visual acuity and hearing status of children and young adult with ID in Special Olympics Sarawak. Methods Health data were collected by trained health professionals under HAP®held in conjunction with Special Olympics Sarawak State Games on 17th and 18th April 2010 in Sibu. Health data collected were athletes' weight, BMI, BP, ear canal screen and hearing status (oto-acoustic emission, pure tone audiometry), as well as eye health and visual acuity, using guidelines set by HAP®. Results 195 athletes attended the State Games in 2010 of which 138 were screened. Significant number of athletes was considered overweight / obese (31.5% for children and 36.9% for adult). More than 20% of the adult athletes were hypertensive or at risk of hypertension. Sixteen percent of the adult athletes had hearing loss. More than half of the adult and children athletes never had eye checks, and a significant numbers of them had abnormal eye tests results. Conclusions Health screening conducted during the HAP® is a useful screening program in this population. Health data collected can bring awareness to athletes and their family, and corrective measures in hearing and visual impairment can be taken immediately.
    Matched MeSH terms: Audiometry, Pure-Tone
  4. Wahab NA, Rashid MF
    Singapore Med J, 2009 Nov;50(11):1077-9.
    PMID: 19960163
    INTRODUCTION: The present study aimed to obtain preliminary tympanometric data of young Malay adults and to compare the results between genders.
    METHODS: 96 undergraduate students (49 males and 47 females), aged 19-25 (mean and standard deviation 21.14 +/- 1.31) years, participated in this study. Otoscopic examination, pure tone audiometry, qualitative tympanogram and ipsilateral acoustic reflex were measured to ensure a clear ear canal, normal hearing and normal middle ear function, prior to tympanometric measurement. As a result, a total of 154 ears (80 ears from males and 74 ears from females) were selected for further statistical analyses. The tympanometric parameters measured were peak compensated static acoustic admittance (Peak Y(tm)), tympanometric width (TW) and equivalent ear canal volume (V(ea)).
    RESULTS: The results showed that the mean Peak Y(tm), V(ea) and TW for males were 0.81 mmhos, 1.48 cubic cm and 113.67 daPa, respectively. The mean Peak Y(tm), V(ea) and TW for females were 0.63 mmhos, 1.12 cubic cm and 98.04 daPa, respectively. Males were found to have significantly higher mean V(ea) and mean Peak Y(tm) than females. However no significant gender difference was observed in the mean TW.
    CONCLUSION: The current study suggests that young Malay adults may require gender-specific Peak Y(tm) and V(ea) values when implementing a quantitative approach in tympanogram interpretation.
    Matched MeSH terms: Audiometry, Pure-Tone
  5. Zakaria MN, Abdullah R, Nik Othman NA
    Ear Hear, 2018 11 22;40(4):1039-1042.
    PMID: 30461445 DOI: 10.1097/AUD.0000000000000676
    OBJECTIVES: Post-auricular muscle response (PAMR) is a large myogenic potential that can be useful in estimating behavioral hearing thresholds when the recording protocol is optimal. The main aim of the present study was to determine the influence of stimulus repetition rate on PAMR threshold.

    DESIGN: In this repeated-measures study, 20 normally hearing adults aged between 18 and 30 years were recruited. Tone bursts (500, 1000, 2000, and 4000 Hz) were used to record PAMR thresholds at 3 different stimulus repetition rates (6.1/s, 11.1/s, and 17.1/s).

    RESULTS: Statistically higher PAMR thresholds were found for the faster stimulus rate (17.1/s) compared with the slower stimulus rate (6.1/s) (p < 0.05). For all stimulus rates and frequencies, significant correlations were found between PAMR and pure-tone audiometry thresholds (r = 0.62 to 0.82).

    CONCLUSIONS: Even though the stimulus rate effect was significant at most of the tested frequencies, the differences in PAMR thresholds between the rates were small (<5 dB). Nevertheless, based on the correlation results, we suggest the use of 11.1/s stimulus rate when recording PAMR thresholds.

    Matched MeSH terms: Audiometry, Pure-Tone
  6. Zirwatu Hanani, Wan Ahmad Wan Aslynn, Marina L. Alisaputri
    MyJurnal
    Introduction: Clinical studies have shown that people suffering from tinnitus are at a high risk of developing serious psychological disturbances or serious psychological distress (Erlandsson &
    Widen, 2004 in Hiller and Goebel, 1998). Thus the purpose of this study was to determine the
    relationship between life-time noise exposure and tinnitus experience among young adults in IIUM Kuantan. Methods: A cross sectional study was used to determine whether there is any association between tinnitus experiences and life-time noise exposure among 11 young adults in IIUM Kuantan from age of 18 to 35 years old who are exposed to the noise. Hearing assessment was done using otoscopy, tympanometry and pure tone audiometry. Participants were asked to fill in a questionnaire on tinnitus experience, and were fitted with a noise dosimeter that measured their noise exposure during waking hours. Values collected from dosimeter were then converted into cumulative life-time noise exposure which refers to the equivalent noise exposure per year (Jokitulppo, Tolvenen & Bjork, 2005). Results: Average cumulative life-time noise exposure of the participants is 72.54 dBA ± 6.9459. Fifty five percent (55%) reported of sometimes having tinnitus. No correlation was found between cumulative life-time noise exposure and tinnitus experience. Conclusion: The cumulative life-time noise exposure among young adults in IIUM Kuantan was found to be lower than the level considered as hazardous. Despite reports of tinnitus experience, there was no evidence that the tinnitus was due to noise exposure.
    Matched MeSH terms: Audiometry, Pure-Tone
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links