Displaying publications 41 - 47 of 47 in total

Abstract:
Sort:
  1. Yahya WN, Kadri NA, Ibrahim F
    Sensors (Basel), 2014 Jul 02;14(7):11714-34.
    PMID: 24991941 DOI: 10.3390/s140711714
    Liver transplantation is the most common treatment for patients with end-stage liver failure. However, liver transplantation is greatly limited by a shortage of donors. Liver tissue engineering may offer an alternative by providing an implantable engineered liver. Currently, diverse types of engineering approaches for in vitro liver cell culture are available, including scaffold-based methods, microfluidic platforms, and micropatterning techniques. Active cell patterning via dielectrophoretic (DEP) force showed some advantages over other methods, including high speed, ease of handling, high precision and being label-free. This article summarizes liver function and regenerative mechanisms for better understanding in developing engineered liver. We then review recent advances in liver tissue engineering techniques and focus on DEP-based cell patterning, including microelectrode design and patterning configuration.
    Matched MeSH terms: Cell Separation/instrumentation; Cell Separation/methods*
  2. Ng AM, Kojima K, Kodoma S, Ruszymah BH, Aminuddin BS, Vacanti AC
    Med J Malaysia, 2008 Jul;63 Suppl A:121-2.
    PMID: 19025015
    Bone marrow derived progenitor cells have been widely studied for its multipotent property and have proofed to be an important resource in regenerative medicine. However, the propagation of murine bone marrow appeared to be a great challenge as compared to other mammalian species. In this study, various isolation techniques and the plasticity of the isolated cells were evaluated. Our result shows that magnetic sorting technique yielded the most viable cells and displayed wider differentiation capacity.
    Matched MeSH terms: Cell Separation/instrumentation; Cell Separation/methods*
  3. Kamuri MF, Zainal Abidin Z, Yaacob MH, Hamidon MN, Md Yunus NA, Kamarudin S
    Biosensors (Basel), 2019 Mar 14;9(1).
    PMID: 30875829 DOI: 10.3390/bios9010040
    This paper describes the development of an integrated system using a dry film resistant (DFR) microfluidic channel consisting of pulsed field dielectrophoretic field-flow-fractionation (DEP-FFF) separation and optical detection. The prototype chip employs the pulse DEP-FFF concept to separate the cells (Escherichia coli and Saccharomyces cerevisiae) from a continuous flow, and the rate of release of the cells was measured. The separation experiments were conducted by changing the pulsing time over a pulsing time range of 2⁻24 s and a flow rate range of 1.2⁻9.6 μ L min - 1 . The frequency and voltage were set to a constant value of 1 M Hz and 14 V pk-pk, respectively. After cell sorting, the particles pass the optical fibre, and the incident light is scattered (or absorbed), thus, reducing the intensity of the transmitted light. The change in light level is measured by a spectrophotometer and recorded as an absorbance spectrum. The results revealed that, generally, the flow rate and pulsing time influenced the separation of E. coli and S. cerevisiae. It was found that E. coli had the highest rate of release, followed by S. cerevisiae. In this investigation, the developed integrated chip-in-a lab has enabled two microorganisms of different cell dielectric properties and particle size to be separated and subsequently detected using unique optical properties. Optimum separation between these two microorganisms could be obtained using a longer pulsing time of 12 s and a faster flow rate of 9.6 μ L min - 1 at a constant frequency, voltage, and a low conductivity.
    Matched MeSH terms: Cell Separation/instrumentation; Cell Separation/methods*
  4. Lim LH, Ton SH, Cheong SK
    Malays J Pathol, 1990 Jun;12(1):39-41.
    PMID: 2090888
    The 'Dextran' and the 'Buffy-coat' methods for isolation of human leucocytes for DNA extraction were compared on the basis of DNA yield from the same amounts (10 ml) of blood. Human leucocytes from a total of 11 samples were isolated using both methods for each sample after which DNA was extracted. Extracted DNA samples were treated with ribonucleases and proteinase K after which the yields were quantitated by measuring absorbance at 260 nm. The 'Buffy-coat' method yielded a mean concentration of DNA of 476.7 micrograms/ml (range: 212 to 700 micrograms/ml) while the 'Dextran' method yielded 188.4 micrograms/ml (range: 64 to 340 micrograms/ml). The difference was confirmed by subjecting the extracted DNA samples to agarose gel electrophoresis.
    Matched MeSH terms: Cell Separation/methods*
  5. Yafouz B, Kadri NA, Ibrahim F
    Sensors (Basel), 2013 Jul 12;13(7):9029-46.
    PMID: 23857266 DOI: 10.3390/s130709029
    During the last three decades; dielectrophoresis (DEP) has become a vital tool for cell manipulation and characterization due to its non-invasiveness. It is very useful in the trend towards point-of-care systems. Currently, most efforts are focused on using DEP in biomedical applications, such as the spatial manipulation of cells, the selective separation or enrichment of target cells, high-throughput molecular screening, biosensors and immunoassays. A significant amount of research on DEP has produced a wide range of microelectrode configurations. In this paper; we describe the microarray dot electrode, a promising electrode geometry to characterize and manipulate cells via DEP. The advantages offered by this type of microelectrode are also reviewed. The protocol for fabricating planar microelectrodes using photolithography is documented to demonstrate the fast and cost-effective fabrication process. Additionally; different state-of-the-art Lab-on-a-Chip (LOC) devices that have been proposed for DEP applications in the literature are reviewed. We also present our recently designed LOC device, which uses an improved microarray dot electrode configuration to address the challenges facing other devices. This type of LOC system has the capability to boost the implementation of DEP technology in practical settings such as clinical cell sorting, infection diagnosis, and enrichment of particle populations for drug development.
    Matched MeSH terms: Cell Separation/instrumentation*
  6. Maqbool M, Vidyadaran S, George E, Ramasamy R
    Med J Malaysia, 2011 Oct;66(4):296-9.
    PMID: 22299545 MyJurnal
    Functional analysis of neutrophils requires isolation of these cells in the laboratory. Current isolation procedures are time consuming and can potentially activate the resting neutrophils. Thus, in this present study, we have optimised an existing laboratory protocol for human neutrophil isolation from peripheral blood. Twenty ml of blood samples were subjected to optimised density gradient separation and dextran sedimentation to obtain a pure population of neutrophils. The efficacy of the optimised manual post isolation of neutrophils was compared with pre isolation count performed by an automated haematology analyzer. The recovery of neutrophils via our optimised methods was 65.5% in comparison with neutrophils counts at pre-isolation. The morphological analysis of isolated neutrophils indicated the purity level more than 95% using Leishman staining. Our optimised laboratory procedures for neutrophils isolation successfully harvested neutrophils with good viability, purity and post recovery yield. This procedure provides an ideal platform to separate neutrophils for in vitro studies.
    Matched MeSH terms: Cell Separation/methods*
  7. Deivasigamani R, Mohd Maidin NN, Abdul Nasir NS, Abdulhameed A, Ahmad Kayani AB, Mohamed MA, et al.
    Electrophoresis, 2023 Mar;44(5-6):573-620.
    PMID: 36604943 DOI: 10.1002/elps.202200203
    Dielectrophoresis (DEP) bioparticle research has progressed from micro to nano levels. It has proven to be a promising and powerful cell manipulation method with an accurate, quick, inexpensive, and label-free technique for therapeutic purposes. DEP, an electrokinetic phenomenon, induces particle movement as a result of polarization effects in a nonuniform electrical field. This review focuses on current research in the biomedical field that demonstrates a practical approach to DEP in terms of cell separation, trapping, discrimination, and enrichment under the influence of the conductive medium in correlation with bioparticle viability. The current review aims to provide readers with an in-depth knowledge of the fundamental theory and principles of the DEP technique, which is influenced by conductive medium and to identify and demonstrate the biomedical application areas. The high conductivity of physiological fluids presents obstacles and opportunities, followed by bioparticle viability in an electric field elaborated in detail. Finally, the drawbacks of DEP-based systems and the outlook for the future are addressed. This article will aid in advancing technology by bridging the gap between bioscience and engineering. We hope the insights presented in this review will improve cell suspension medium and promote DEP-viable bioparticle manipulation for health-care diagnostics and therapeutics.
    Matched MeSH terms: Cell Separation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links