Displaying publications 41 - 60 of 69 in total

Abstract:
Sort:
  1. Le Ho Y, Ahmad Zaidi NA, Salleh A, Abdul Kareem BA
    J Cardiothorac Surg, 2021 Apr 17;16(1):92.
    PMID: 33865405 DOI: 10.1186/s13019-021-01458-2
    BACKGROUND: Antiphospholipid syndrome is an antibody mediated pro-thrombotic state leading to various arterial and venous thromboses. The syndrome can be either primary or secondary to other autoimmune diseases, commonly systemic lupus erythematosus. Cardiac involvement, in particular valvular disease is common in patients with antiphospholipid syndrome, occurring in about a third of these patients. Valvular diseases associated with antiphospholipid syndrome often occur as valve thickening and non-bacterial vegetation or Libman-Sacks endocarditis. Deposits of antiphospholipid immunoglobulin and complement components are commonly observed in the affected valves, suggesting an inflammatory process resulting in valvular vegetation and thickening. Libman-Sacks endocarditis has a high propensity towards mitral valve, although haemodynamically significant valvular dysfunction is rare.

    CASE PRESENTATION: We present a successful aortic valve replacement with cardiopulmonary bypass in a 48 years old lady with antiphospholipid syndrome, who has severe aortic regurgitation as a result of Libman-sacks endocarditis. Antiphospholipid antibodies were positive and the clinical data showed both negative cultures and infective parameters. Surgically resected vegetations revealed sterile fibrinous and verrucous vegetations on aortic valve. Valve replacement and the course of cardiopulmonary bypass was uneventful, and the patient was discharged well.

    CONCLUSIONS: Classically Libman-Sacks endocarditis is often and more commonly associated with autoimmune diseases such as systemic lupus erythematosus, although it can occur in both primary and secondary antiphospholipid syndrome. It is not a common entity, and it is a frequent underestimated disease as most clinicians do not routinely screen for valvular lesion in patients with antiphospholipid syndrome unless they are symptomatic. However, due to its high prevalence of cardiac involvement, clinicians should have a high index of suspicion in the attempt to minimize cardiovascular and haemodynamic complications. Valve surgery in patients with antiphospholipid syndrome carries considerable early and late morbidity and mortality, usually caused by thromboembolic and bleeding events. The perioperative anticoagulation management and haemostatic aspect of antiphospholipid syndrome present an exceptional challenges to clinicians, surgeons, anaesthetists and laboratory personnel.

    Matched MeSH terms: Heart Valve Prosthesis Implantation*
  2. Yakub MA, Dillon J, Krishna Moorthy PS, Pau KK, Nordin MN
    Eur J Cardiothorac Surg, 2013 Oct;44(4):673-81.
    PMID: 23447474 DOI: 10.1093/ejcts/ezt093
    Contemporary experience with mitral valve (MV) repair in the rheumatic population is limited. We aimed to examine the long-term outcomes of rheumatic MV repair, to identify the predictors of durability and to compare the repair for rheumatic and degenerative MVs.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/methods*
  3. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  4. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*
  5. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  6. Liew NC, Moissinac K, Lee L, Gee T, Zezeman RB
    Med J Malaysia, 2011 Oct;66(4):386-8; quiz 389.
    PMID: 22299571 MyJurnal
    There has been much progress made in the management of peripheral arterial disease (PAD) in the past two decades. Progress in the understanding of the endothelial-platelet interaction during health and disease state have resulted in better antiplatelet drugs that can prevent platelet aggregation, activation and thrombosis during angioplasty and stenting. Collaborative effort by different international societies has resulted in a consensus guideline that recommends the modality of intervention in certain disease states. Progress in perioperative care has reduced the morbidity and mortality associated with peripheral vascular reconstruction surgery. Nevertheless, the advances in percutaneous peripheral intervention (PPI) have made a paradigm shift in the current management of patients. The procedure is safe and effective and is emerging as the first choice revascularization procedure.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  7. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*; Heart Valve Prosthesis Implantation/methods
  8. Lim TW, Ab Ghani SM, Mahmud M
    J Prosthet Dent, 2020 Dec 02.
    PMID: 33279159 DOI: 10.1016/j.prosdent.2020.06.034
    STATEMENT OF PROBLEM: Resin-bonded fixed partial dental prostheses (RBFPDPs) cemented at an increased occlusal vertical dimension (OVD) (the Dahl concept) to create space for a metal retainer remain controversial because of the lack of reported clinical studies. This study evaluated RBFPDPs by applying the Dahl concept.

    PURPOSE: The purpose of this retrospective study was to investigate the clinical factors affecting the occlusal re-establishment and short-term complications of RBFPDPs cemented at an increased OVD.

    MATERIAL AND METHODS: Occlusal re-establishment and clinical complications were reviewed in 109 participants (155 RBFPDPs) treated at the Faculty of Dentistry, Universiti Teknologi MARA from January 2013 to May 2018. Types of complications and risk factors were assessed from clinical data. Demographic factors, clinical factors, and prosthesis factors were distinguished and their association with occlusal re-establishment analyzed by using multiple regression analysis.

    RESULTS: A total of 155 RBFPDPs (42 anterior, 113 posterior) were placed in 109 participants. All achieved occlusal re-establishment, 89.9% complete occlusal re-establishment and 10.1% partial occlusal re-establishment, a minimum of 4 months after the RBFPDPs had been placed at an increased OVD. The design of the metal retainer coverage was found to be a significant factor affecting occlusal re-establishment and decementation (P

    Matched MeSH terms: Prosthesis Implantation
  9. Idris RI, Shoji Y, Lim TW
    J Prosthet Dent, 2021 Jan 14.
    PMID: 33455729 DOI: 10.1016/j.prosdent.2020.11.035
    STATEMENT OF PROBLEM: Space creation for a metal retainer of the resin-bonded fixed partial dental prostheses (RBFPDPs) with the Dahl concept remains controversial because of the lack of clinical studies.

    PURPOSE: The purpose of this clinical study was to investigate the occlusal force and occlusal contact reestablishment of RBFPDPs cemented at an increased occlusal vertical dimension (the Dahl concept) and to evaluate the factors affecting them.

    MATERIAL AND METHODS: A prospective clinical study was carried out on 28 participants receiving cantilevered RBFPDPs at an increased occlusal vertical dimension at the Faculty of Dentistry, University Teknologi MARA. Maximum occlusal forces were recorded at precementation, postcementation, and 12-week review visit by using pressure indicating film, while occlusal contact reestablishment was assessed at the precementation stage and 12-week review visit by using shim stock foils. The Wilcoxon signed-rank and chi-squared tests were used for statistical analysis (α=.05).

    RESULTS: Significant differences were found for maximum occlusal force between the precementation and the postcementation and between the postcementation and the 12-week review of RBFPDPs (P.05).

    CONCLUSIONS: Overall, occlusal force was reestablished after 12 weeks, and occlusal contact was completely reestablished in most participants after placement of RBFPDPs at an increased occlusal vertical dimension.

    Matched MeSH terms: Prosthesis Implantation
  10. Yusof NM, Oh CW, Oh JK, Kim JW, Min WK, Park IH, et al.
    Injury, 2009 Dec;40(12):1286-91.
    PMID: 19539282 DOI: 10.1016/j.injury.2009.02.020
    Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.
    Matched MeSH terms: Prosthesis Implantation/methods
  11. Krishna Moorthy PS, Sivalingam S, Dillon J, Kong PK, Yakub MA
    Interact Cardiovasc Thorac Surg, 2019 02 01;28(2):191-198.
    PMID: 30085022 DOI: 10.1093/icvts/ivy234
    OBJECTIVES: Contemporary experience in mitral valve (MV) repair for children with rheumatic heart disease (RHD) is limited, despite the potential advantages of repair over replacement. We reviewed our long-term outcomes of rheumatic MV repair and compared them with the outcomes of MV replacement in children with RHD.

    METHODS: This study is a review of 419 children (≤18 years) with RHD who underwent primary isolated MV surgery between 1992 and 2015, which comprised MV repair (336 patients; 80.2%) and MV replacement (83 patients; 19.8%). The replacement group included mechanical MV replacements (MMVRs) (n = 69 patients; 16.5%) and bioprosthetic MV replacements (n = 14 patients; 3.3%). The mean age with standard deviation at the time of operation was 12.5 ± 3.5 (2-18) years. Mitral regurgitation (MR) was predominant in 390 (93.1%) patients, and 341 (81.4%) patients showed ≥3+ MR. The modified Carpentier reconstructive techniques were used for MV repair.

    RESULTS: Overall early mortality was 1.7% (7 patients). The mean follow-up was 5.6 years (range 0-22.3 years; 94.7% complete). Survival of patients who underwent repair was 93.9% both at 10 and 20 years, which was superior than that of replacement (P 

    Matched MeSH terms: Heart Valve Prosthesis Implantation/methods*
  12. Tan AK, Pall S
    Med J Malaysia, 2011 Oct;66(4):284-5.
    PMID: 22299542 MyJurnal
    Matched MeSH terms: Prosthesis Implantation*
  13. Dhanoa A, Singh VA, Shanmugam R, Rajendram R
    World J Surg Oncol, 2010;8:96.
    PMID: 21059231 DOI: 10.1186/1477-7819-8-96
    We describe an unusual case of osteosarcoma in a Jehovah's Witness patient who underwent chemotherapy and major surgery without the need for blood transfusion. This 16-year-old girl presented with osteosarcoma of the right proximal tibia requiring proximal tibia resection, followed by endoprosthesis replacement. She was successfully treated with neoadjuvant chemotherapy and surgery with the support of haematinics, granulocyte colony-stimulating factor, recombinant erythropoietin and intraoperative normovolaemic haemodilution. This case illustrates the importance of maintaining effective, open communication and exploring acceptable therapeutic alternative in the management of these patients, whilst still respecting their beliefs.
    Matched MeSH terms: Prosthesis Implantation/methods
  14. Low HL, Ismail MNBM, Taqvi A, Deeb J, Fuller C, Misbahuddin A
    Clin Neurol Neurosurg, 2019 Oct;185:105466.
    PMID: 31466022 DOI: 10.1016/j.clineuro.2019.105466
    OBJECTIVE: To compare posterior subthalamic area deep brain stimulation (PSA-DBS) performed in the conventional manner against diffusion tensor imaging and tractography (DTIT)-guided lead implantation into the dentatorubrothalamic tract (DRTT).

    PATIENTS AND METHODS: Double-blind, randomised study involving 34 patients with either tremor-dominant Parkinson's disease or essential tremor. Patients were randomised to Group A (DBS leads inserted using conventional landmarks) or Group B (leads guided into the DRTT using DTIT). Tremor (Fahn-Tolosa-Marin) and quality-of-life (PDQ-39) scores were evaluated 0-, 6-, 12-, 36- and 60-months after surgery.

    RESULTS: PSA-DBS resulted in marked tremor reduction in both groups. However, Group B patients had significantly better arm tremor control (especially control of intention tremor), increased mobility and activities of daily living, reduced social stigma and need for social support as well as lower stimulation amplitudes and pulse widths compared to Group A patients. The better outcomes were sustained for up to 60-months from surgery. The active contacts of Group B patients were consistently closer to the centre of the DRTT than in Group A. Speech problems were more common in Group A patients.

    CONCLUSION: DTIT-guided lead placement results in better and more stable tremor control and fewer adverse effects compared to lead placement in the conventional manner. This is because DTIT-guidance allows closer and more consistent placement of leads to the centre of the DRTT than conventional methods.

    Matched MeSH terms: Prosthesis Implantation/methods*
  15. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Prosthesis Implantation/methods*
  16. Gholizadeh H, Abu Osman NA, Lúvíksdóttir Á, Eshraghi A, Kamyab M, Wan Abas WA
    Prosthet Orthot Int, 2011 Dec;35(4):360-4.
    PMID: 21975850 DOI: 10.1177/0309364611423130
    Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning.
    Matched MeSH terms: Prosthesis Implantation
  17. Azhar MM, Sara TA
    Med J Malaysia, 2004 Dec;59(5):578-84.
    PMID: 15889558
    A study of nerve regeneration through a 1cm defect in the peroneal component of the sciatic nerve was performed on sixteen rabbits. Either silicone or polytetrafluoroethylene (PTFE) tubes or nerve graft were used to bridge the defect and the opposite limb was not operated upon. The rabbits that underwent nerve grafting had favourable findings. In the PTFE group, a nerve-like structure was seen at the former gap site and histology confirmed viable axons within the tubes and distal to the repair site. In the silicone tube group, there were no myelinated axons demonstrated. The axonal count for the grafted nerves and the nerves repaired with PTFE tube are on average 80.4% and 38.2% of that of the unoperated nerve, respectively. On average, the percentage anterior compartment muscle weight (expressed as a percentage of the unoperated limb) for the silicone, PTFE and nerve graft groups are 42.3%, 42.1%, and 72.7% respectively. The results show that although, PTFE conduits can bridge a nerve defect of 1cm, nerve grafting provides a superior and more predictable outcome.
    Matched MeSH terms: Prosthesis Implantation
  18. Inn FX, Ahmed N, Hou LG, Abidin ZAZ, Yi LL, Zainuddin ZM
    Int Urol Nephrol, 2019 Nov;51(11):1949-1953.
    PMID: 31441009 DOI: 10.1007/s11255-019-02262-7
    PURPOSE: The internal drainage provided by a ureteral stent helps with the relief and prevention of ureteral obstruction. By definition, correct stent placement is one with a complete loop in both the renal pelvis and bladder. This prevents stent migration proximally or distally despite urinary flow, patient movement, and ureteral peristalsis.

    METHODS: We performed a comparative prospective cross-sectional study assessing the impact of intravesical stent position on the quality of life in 46 patients with a ureteral stent. This is done using the Ureteral Stent Symptom Questionnaire (USSQ).

    RESULTS: 52.5% of patients had an ipsilateral positioned intravesical stent, while the remaining had their stent positioned contralaterally. Intravesical stent position significantly influenced the quality of life. The USSQ score was worse for the contralateral group. Subscore analysis found that urinary symptoms and body pain index contribute significantly to the morbidity. Majority of patients in the ipsilateral group reported no discomfort as compared to the contralateral group.

    CONCLUSIONS: To the best of our knowledge, this is the first study assessing the impact of intravesical stent position on the quality of life in the Asian population. Intravesical stent position has a significant influence on patient's morbidity and quality of life in particular towards their urinary irritative symptoms and body pain. It is imperative to ensure correct distal placement of ureteric stent that does not cross the midline to the contralateral site. We believe that the USSQ should be used in daily clinical practice in assessing the symptoms related to indwelling ureteric stents.

    Matched MeSH terms: Prosthesis Implantation
  19. Muhamad Imran Abdulah, Ikmal Abdul Hakim, Rosni Amin, Rosliza Parumo, Ma, Bee Chai, Noraziyah Abdul Aziz, et al.
    Q Bulletin, 2020;1(29):16-27.
    MyJurnal
    The Department of Oral & Maxillofacial Surgery at Hospital Sultanah Aminah, Johor Bahru started managing patients who lost their eyeballs with ocular prosthesis in 2013. Unfortunately, there was an increasing trend of failed ocular prosthesis from 2013-2015. The failure rate went from 28.6% in 2013 to 40% in 2014 and increased to 44.4% in 2015. Failed ocular prosthesis not only leads to dissatisfied patients but also an increase in cost due to redoing of prosthesis. The objective of this project was to reduce the incidence rate of failed ocular prosthesis. A failed case is when the prosthesis does not pass the issue stage and has to be redone from the beginning. The standard failure rate is 0%, as the average number of cases per year is only about 10 cases. We determined the contributing factors of failed ocular prosthesis by analysing retrospective data from patients’ dental and lab records. This was followed by a self-administered questionnaire on reasons for failed cases which was distributed among the dentists and lab technicians in our department. The contributing factors that were identified included insufficient knowledge or skill of dentist and lab technicians in the construction of the ocular prosthesis, as well as improper screening of new cases which was the main factor of all the failed cases. The strategies for change included improving the process of care by creating a checklist for proper screening of new patients, mentoring of new staff, and continuous training on construction of ocular prosthesis, Fabricated Iris Mould innovation technique and early referral for insertion of eye conformer. The interventions that were implemented reduced the failure rate to 20% in 2016 followed by 0% in 2017, 2018 and 2019. Ongoing efforts are being done to replicate this project in other Oral & Maxillofacial Surgery clinics in Johor.
    Matched MeSH terms: Prosthesis Implantation
  20. Karim HHA, Chern PM
    Med J Malaysia, 2020 09;75(5):519-524.
    PMID: 32918420
    INTRODUCTION: Increasing numbers of limb amputation are performed globally and in Malaysia due to the rise of complications because of Diabetes Mellitus (DM). Limb amputation influences many aspects of an individual's life, and prosthesis restoration is one of the primary rehabilitation goals to help amputees resume daily activities. As limited information is available in Malaysia, this study aims to determine the socio-demographic, clinical characteristics and prosthesis usage among the amputees.

    METHODS: A cross-sectional study using self-developed survey form was conducted at 13 Medical Rehabilitation Clinics in Malaysia among 541 upper and lower limb amputees of any duration and cause.

    RESULTS: The study population had a mean age of 54 years. Majority were males, Malays, married and had completed secondary school. About 70% of amputations were performed due to DM complications and at transtibial level. Fifty-eight percent of unilateral lower limb amputees were using prosthesis with a mean (standard deviation) of 6.48 (±4.55) hours per day. Time since amputation was the true factor associated with prosthesis usage. Longer hours of prosthesis use per day was positively correlated with longer interval after prosthesis restoration (r=0.467).

    CONCLUSION: Higher aetiology of DM and lower prosthesis usage among amputees may be because of high prevalence of DM in Malaysia. The prosthesis usage and hours of use per day were low compared to the international reports, which may be influenced by sampling location and time since amputation. Nevertheless, this is a novel multicentre study on the characteristics and prosthesis usage of amputees. Hopefully, this research will assist to support, facilitate and promote prosthesis rehabilitation in Malaysia.