Displaying publications 61 - 74 of 74 in total

Abstract:
Sort:
  1. Ahmad N, Ruzan IN, Abd Ghani MK, Hussin A, Nawi S, Aziz MN, et al.
    J Med Microbiol, 2009 Sep;58(Pt 9):1213-1218.
    PMID: 19528158 DOI: 10.1099/jmm.0.011353-0
    Community-acquired meticillin-resistant Staphylococcus aureus (CA-MRSA) occurring among hospital isolates in Malaysia has not been reported previously. As CA-MRSA reported worldwide has been shown to carry SCCmec types IV and V, the aim of this study was to determine the SCCmec types of MRSA strains collected in Malaysia from November 2006 to June 2008. From a total of 628 MRSA isolates, 20 were SCCmec type IV, whilst the rest were type III. Further characterization of SCCmec type IV strains revealed 11 sequence types (STs), including ST22, with the majority being ST30/Panton-Valentine leukocidin positive. Eight out of nine CA-MRSA were ST30, one was ST80, and all were sensitive to co-trimoxazole and gentamicin. Five new STs designated ST1284, ST1285, ST1286, ST1287 and ST1288 were discovered, suggesting the emergence of novel clones of MRSA circulating in Malaysian hospitals. The discovery of the ST22 strain is a cause for concern because of its ability to replace existing predominant clones in certain geographical regions.
  2. Man K, Kareem AM, Ahmad Alias NA, Shuaib IL, Tharakan J, Abdullah JM, et al.
    Singapore Med J, 2006 Mar;47(3):194-7.
    PMID: 16518552
    Computed tomography (CT) perfusion is a new method to diagnose ischaemic stroke especially in developing countries. It identifies the area and is useful to predict the size of final infarction. The aim of this study was to assess cerebral ischaemia with CT perfusion (CTP) among patients with acute ischaemic stroke in Hospital Universiti Sains Malaysia, a tertiary referral centre in a rural setting.
  3. Crossley GH, Biffi M, Johnson B, Lin A, Gras D, Hussin A, et al.
    Heart Rhythm, 2015 Apr;12(4):751-8.
    PMID: 25533587 DOI: 10.1016/j.hrthm.2014.12.019
    The Medtronic Attain Performa quadripolar leads provide 16 pacing vectors with steroid on every electrode. This includes a short bipolar configuration between the middle 2 electrodes.
  4. Zhang S, Singh B, Rodriguez DA, Chasnoits AR, Hussin A, Ching CK, et al.
    Europace, 2015 Nov;17(11):1720-6.
    PMID: 26037794 DOI: 10.1093/europace/euv103
    This study aims to demonstrate that primary prevention (PP) patients with one or more additional risk factors are at a similar risk of life-threatening ventricular arrhythmias when compared with secondary prevention (SP) patients, and would receive similar benefit from an implantable cardioverter defibrillator (ICD), or cardiac resynchronization therapy-defibrillator (CRT-D) implant. The study evaluates the benefits of therapy for high-risk patients in countries where defibrillation therapy for PP of SCA is underutilized.
  5. Yap LB, Eng DT, Sivalingam L, Rusani BI, Umadevan D, Muhammad Z, et al.
    Clin Appl Thromb Hemost, 2016 Nov;22(8):792-797.
    PMID: 25962393 DOI: 10.1177/1076029615584664
    BACKGROUND: The Asian population with atrial fibrillation (AF) have a higher risk of stroke than the caucasian population and a higher risk of intracranial bleeding when anticoagulated with warfarin. There are few real-world studies comparing the efficacy of non-vitamin K antagonist oral anticoagulants (NOACs) and warfarin among Asian patients to assess its outcomes of ischemic stroke and hemorrhagic stroke.
    METHODS: A retrospective cohort study of 1000 patients on dabigatran and warfarin from 2009 to 2013.
    RESULTS: Data were available for 500 patients on dabigatran and 500 patients on warfarin. The average follow-up duration was 315 ± 280 days in the dabigatran group and 355 ± 232 in the warfarin group. The time in therapeutic range (TTR) was 53.2% in the warfarin-treated group, with 32.8% of patients in the subtherapeutic international normalized ratio range of <2. None of the patients in the dabigatran group had ischemic cerebrovascular accident (CVA) compared to 4 (0.8%) patients in the warfarin group, hazard ratio (HR) 0.13, P = .3. There was 1 (0.2%) patient in both dabigatran and warfarin groups with hemorrhagic CVA (HR 1.16, P = .92). There were 3 (0.6%) patients with major bleeding in the dabigatran group compared to 2 (0.4%) patients in the warfarin group (HR 1.57, P = .59).
    CONCLUSION: There were similar rates of efficacy for outcomes of ischemic CVA, hemorrhagic CVA, and bleeding when comparing dabigatran with warfarin. Our study shows that despite similar efficacy, suboptimal TTR rates and inconveniences with warfarin demonstrate that NOACs are preferred for stroke prevention in AF.
    KEYWORDS: dabigatran; non-valvular atrial fibrillation; novel anticoagulant; stroke prevention; warfarin
  6. McGrattan A, Mohan D, Chua PW, Mat Hussin A, Soh YC, Alawad M, et al.
    BMJ Open, 2020 08 27;10(8):e035453.
    PMID: 32859661 DOI: 10.1136/bmjopen-2019-035453
    INTRODUCTION: Global population ageing is one of the key factors linked to the projected rise of dementia incidence. Hence, there is a clear need to identify strategies to overcome this expected health burden and have a meaningful impact on populations' health worldwide. Current evidence supports the role of modifiable dietary and lifestyle risk factors in reducing the risk of dementia. In South-East Asia, changes in eating and lifestyle patterns under the influence of westernised habits have resulted in significant increases in the prevalence of metabolic, cardiovascular and neurodegenerative non-communicable diseases (NCDs). Low vegetable consumption and high sodium intake have been identified as key contributors to the increased prevalence of NCDs in these countries. Therefore, nutritional and lifestyle strategies targeting these dietary risk factors are warranted. The overall objective of this randomised feasibility trial is to demonstrate the acceptability of a dietary intervention to increase the consumption of high-nitrate green leafy vegetables and reduce salt intake over 6 months among Malaysian adults with raised blood pressure.

    METHODS AND ANALYSIS: Primary outcomes focus on feasibility measures of recruitment, retention, implementation and acceptability of the intervention. Secondary outcomes will include blood pressure, cognitive function, body composition and physical function (including muscle strength and gait speed). Adherence to the dietary intervention will be assessed through collection of biological samples, 24-hour recall and Food Frequency Questionnaire. A subgroup of participants will also complete postintervention focus groups to further explore the feasibility considerations of executing a larger trial, the ability of these individuals to make dietary changes and the barriers and facilitators associated with implementing these changes.

    ETHICS AND DISSEMINATION: Ethical approval has been obtained from Monash University Human Research Ethics Committee and Medical Research and Ethics Committee of Malaysia. Results of the study will be disseminated via peer-reviewed publications and presentations at national and international conferences.ISRCTN47562685; Pre-results.

  7. Singh B, Zhang S, Ching CK, Huang D, Liu YB, Rodriguez DA, et al.
    Pacing Clin Electrophysiol, 2018 12;41(12):1619-1626.
    PMID: 30320410 DOI: 10.1111/pace.13526
    BACKGROUND: Despite available evidence that implantable cardioverter defibrillators (ICDs) reduce all-cause mortality among patients at risk for sudden cardiac death, utilization of ICDs is low especially in developing countries.

    OBJECTIVE: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries.

    METHODS: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction 

  8. Lin AC, Biffi M, Exner DV, Johnson WB, Gras D, Hussin A, et al.
    PMID: 29808920 DOI: 10.1111/pace.13389
    BACKGROUND: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study.

    METHODS: A total of 1,097 subjects were included in this evaluation. At each follow-up visit (1, 3, 6, and 12 months), LV PCT and pacing impedance were measured using either manual or automated testing methods. Summary statistics for PCT and impedance values were obtained for implant and each scheduled follow-up visit for all lead models.

    RESULTS: Average extended bipolar (LV electrode to right ventricular Coil) PCTs for the four LV SE pacing electrodes (LV1, LV2, LV3, and LV4) on the three shapes of the quadripolar LV leads were 1.06 ± 0.97 V, 1.38 ± 1.26 V, 1.51 ± 1.33 V, and 2.25 ± 1.63 V, respectively, at 0.5-ms pulse width. PCTs remained low and stable throughout the 12-month follow-up period.

    CONCLUSION: This clinical trial demonstrated that SE on all LV pacing electrodes is associated with low and stable PCTs for all quadripolar LV lead electrodes, resulting in multiple viable vectors for LV pacing. The large number of available vectors facilitates basal pacing, avoidance of PNS, and potentially prolongs generator longevity due to lower PCTs.

  9. Zhao S, Ching CK, Huang D, Liu YB, Rodriguez-Guerrero DA, Hussin A, et al.
    BMC Med, 2024 Mar 22;22(1):130.
    PMID: 38519982 DOI: 10.1186/s12916-024-03310-5
    BACKGROUND: Comprehensive data on patients at high risk of sudden cardiac death (SCD) in emerging countries are lacking. The aim was to deepen our understanding of the SCD phenotype and identify risk factors for death among patients at high risk of SCD in emerging countries.

    METHODS: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled. Countries were stratified by the WHO regional classification. Patients were or were not implanted with an ICD at their discretion. The outcomes were all-cause mortality and SCD.

    RESULTS: We enrolled 4222 patients, and 3889 patients were included in the analysis. The mean follow-up period was 21.6 ± 10.2 months. There were 433 (11.1%) instances of all-cause mortality and 117 (3.0%) cases of SCD. All-cause mortality was highest in primary prevention (PP) patients from Southeast Asia and secondary prevention (SP) patients from the Middle East and Africa. The SCD rates among PP and SP patients were both highest in South Asia. Multivariate Cox regression modelling demonstrated that in addition to the independent predictors identified in previous studies, both geographic region and ICD use were associated with all-cause mortality in patients with high SCD risk. Primary prophylactic ICD implantation was associated with a 36% (HR = 0.64, 95% CI 0.531-0.802, p 

  10. Yasin RM, Zin NM, Hussin A, Nawi SH, Hanapiah SM, Wahab ZA, et al.
    Vaccine, 2011 Aug 5;29(34):5688-93.
    PMID: 21723357 DOI: 10.1016/j.vaccine.2011.06.004
    From January 2008 to December 2009, 433 Streptococcus pneumoniae strains were examined to determine the serotype distribution and susceptibility to selected antibiotics. About 50% of them were invasive isolates. The strains were isolated from patients of all age groups and 33.55% were isolated from children below 5 years. The majority was isolated from blood (48.53%) and other sterile specimens (6.30%). Community acquired pneumonia (41.70%) is the most common diagnosis followed by sepsis (9.54%). Serotyping was done using Pneumotest Plus-Kit and antibiotic susceptibility pattern was determined by modified Kirby-Bauer disk diffusion method and measurement of minimum inhibitory concentration (MIC) using E-test strip. Ten most common serotypes were 19F (15.02%), 6B (10.62%), 19A (6.93%), 14 (6.70%), 1 (5.08%), 6A (5.08%), 23F (4.85%), 18C (3.93%), 3 (2.08%) and 5 (1.85%). Penicillin MIC ranged between ≤ 0.012-4 μg/ml with MIC₉₀ of 1 μg/ml. Penicillin resistant rate is 31.78%. The majority of penicillin less-susceptible strains belonged to serotype 19F followed by 19A and 6B. Based on the serotypes distribution 22 (44.00%), 28 (56.00%) and 39 (78.00%) of the invasive isolates from children ≤ 2 years were belonged to serotypes included in the PCV7, PCV10 and PCV13, respectively.
  11. Zhang S, Ching CK, Huang D, Liu YB, Rodriguez-Guerrero DA, Hussin A, et al.
    Heart Rhythm, 2020 03;17(3):468-475.
    PMID: 31561030 DOI: 10.1016/j.hrthm.2019.09.023
    BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are underutilized in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA Study is the largest prospective study to evaluate the benefit of ICD therapy in underrepresented geographies. This analysis reports the primary objective of the study.

    OBJECTIVES: The objectives of this study was to determine whether patients with primary prevention (PP) indications with specific risk factors (1.5PP: syncope, nonsustained ventricular tachycardia, premature ventricular contractions >10/h, and low ventricular ejection fraction <25%) are at a similar risk of life-threatening arrhythmias as patients with secondary prevention (SP) indications and to evaluate all-cause mortality rates in 1.5PP patients with and without devices.

    METHODS: A total of 3889 patients were included in the analysis to evaluate ventricular tachycardia or fibrillation therapy and mortality rates. Patients were stratified as SP (n = 1193) and patients with PP indications. The PP cohort was divided into 1.5PP patients (n = 1913) and those without any 1.5PP criteria (n = 783). The decision to undergo ICD implantation was left to the patient and/or physician. The Cox proportional hazards model was used to compute hazard ratios.

    RESULTS: Patients had predominantly nonischemic cardiomyopathy. The rate of ventricular tachycardia or fibrillation in 1.5PP patients was not equivalent (within 30%) to that in patients with SP indications (hazard ratio 0.47; 95% confidence interval 0.38-0.57) but was higher than that in PP patients without any 1.5PP criteria (hazard ratio 0.67; 95% confidence interval 0.46-0.97) (P = .03). There was a 49% relative risk reduction in all-cause mortality in ICD implanted 1.5PP patients. In addition, the number needed to treat to save 1 life over 3 years was 10.0 in the 1.5PP cohort vs 40.0 in PP patients without any 1.5PP criteria.

    CONCLUSION: These data corroborate the mortality benefit of ICD therapy and support extension to a selected PP population from underrepresented geographies.

  12. Ching CK, Hsieh YC, Liu YB, Rodriguez DA, Kim YH, Joung B, et al.
    J Cardiovasc Electrophysiol, 2021 08;32(8):2285-2294.
    PMID: 34216069 DOI: 10.1111/jce.15149
    BACKGROUND: In primary prevention (PP) patients the utilization of implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy-defibrillators (CRT-D) remains low in many geographies, despite the proven mortality benefit.

    PURPOSE: The objective of this analysis was to examine the mortality benefit in PP patients by guideline-indicated device type: ICD and CRT-D.

    METHODS: Improve sudden cardiac arrest was a prospective, nonrandomized, nonblinded multicenter trial that enrolled patients from regions where ICD utilization is low. PP patient's CRT-D or ICD eligibility was based upon the 2008 ACC/AHA/HRS and 2006 ESC guidelines. Mortality was assessed according to guideline-indicated device type comparing implanted and nonimplanted patients. Cox proportional hazards methods were used, adjusting for known factors affecting mortality risk.

    RESULTS: Among 2618 PP patients followed for a mean of 20.8 ± 10.8 months, 1073 were indicated for a CRT-D, and 1545 were indicated for an ICD. PP CRT-D-indicated patients who received CRT-D therapy had a 58% risk reduction in mortality compared with those without implant (adjusted hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61, p 

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links