Displaying publications 61 - 80 of 312 in total

Abstract:
Sort:
  1. Chen ST
    J Singapore Paediatr Soc, 1990;32(3-4):87-96.
    PMID: 2133762
    126 Malaysian children, 65 boys and 61 girls from higher income families were followed-up regularly from birth to six years of age in the University Hospital, Kuala Lumpur. The study shows that for boys and girls, there is a progressive increase in the left mid-upper arm circumference from birth to six years of age. However the rate of growth is not even, being most rapid during the first four month of infancy, then rapidly decreases during the middle third of infancy and thereafter it decreases slowly and by the second year of life, there is hardly any increase in the arm circumference. The left triceps skinfold thickness curves for boys and girls rise rapidly after birth to reach a peak at about three to five months before commencing to decline and then flatten off from the second year of life. The study also shows that on the whole, boys have slightly bigger arm circumference than girls during the first two years of life. From two years of age, girls on the average have more fat than boys. However this difference is statistically not significant at the ages tested. This paper also presents the left mid-upper arm circumference and left triceps skinfold percentile charts of Malaysian boys and girls from birth to six years of age.
    Matched MeSH terms: Reference Values
  2. Chen ST
    J Singapore Paediatr Soc, 1990;32(3-4):81-6.
    PMID: 2133761
    126 Malaysian children, 65 boys and 61 girls from higher income families were followed-up regularly from birth to six years of age in the University Hospital, Kuala Lumpur. The study confirms the observations of previous studies that growth velocity of head circumference is most rapid during the first few months of infancy and then decreases so that by the fifth year of life the increment is minimal. It also confirms the fact that boys have bigger head circumferences than girls. The paper also presents the head circumference distance and velocity percentile charts which can be used to monitor the head circumference of Malaysian children.
    Matched MeSH terms: Reference Values
  3. Partap U, Young EH, Allotey P, Sandhu MS, Reidpath DD
    J Pediatr, 2017 Nov;190:63-68.e1.
    PMID: 29144273 DOI: 10.1016/j.jpeds.2017.07.049
    OBJECTIVE: To assess the prevalence of child underweight, overweight, and obesity in a Malaysian population according to 3 international references because classification of anthropometric status may differ according to the reference used to express body mass index (BMI).

    STUDY DESIGN: We assessed data from 6414 children aged 6-18 years, collected by the South East Asia Community Observatory. Child underweight, overweight, and obesity were expressed according to 3 internationally used BMI references: World Health Organization 2007, International Obesity Task Force 2012, and Centers for Disease Control and Prevention 2000. We assessed agreement in classification of anthropometric status among the references using Cohen's kappa statistic and estimated underweight, overweight, and obesity prevalence according to each reference using mixed effects Poisson regression.

    RESULTS: There was poor to moderate agreement between references when classifying underweight, but generally good agreement when classifying overweight and obesity. Underweight, overweight, and obesity prevalence estimates generated using the 3 references were notably inconsistent. Overweight and obesity prevalence estimates were higher using the World Health Organization reference vs the other 2, and underweight prevalence was up to 8.5% higher and obesity prevalence was about 4% lower when using the International Obesity Task Force reference.

    CONCLUSIONS: The choice of reference to express BMI may influence conclusions about child anthropometric status and malnutrition prevalence. This has implications regarding strategies for clinical management and public health interventions.

    Matched MeSH terms: Reference Values*
  4. West R, Hong J, Derraik JGB, Webster D, Heather NL, Hofman PL
    J Clin Endocrinol Metab, 2020 09 01;105(9).
    PMID: 32598474 DOI: 10.1210/clinem/dgaa415
    BACKGROUND: It is unclear whether newborns with mild thyrotropin elevation (mTSHe) are at risk of neurocognitive impairment. We assessed whether mTSHe at birth persists during childhood and compared neurocognitive functioning to siblings.

    METHODS: This study encompassed children born in the Auckland region (New Zealand) with a newborn screen TSH level of 8 to 14 mIU/L blood, age 6.9 to 12.6 years at assessment, and their siblings. Thyroid function tests (serum TSH and free thyroxine) and neurocognitive assessments were performed, including IQ via the Wechsler Intelligence Scale for Children, fourth edition.

    RESULTS: Ninety-six mTSHe individuals were studied, including 67 children recruited with 75 sibling controls. Mean mTSHe newborn TSH level was 10.1 mIU/L blood and 2.4 mIU/L at assessment (range, 0.8-7.0 mIU/L, serum). Although higher newborn TSH levels in the mTSHe group correlated with lower full-scale IQ scores (r = 0.25; P = .040), they were not associated with the magnitude of the IQ difference within sibling pairs (P = .56). Cognitive scores were similar for mTSHe and controls (full-scale IQ 107 vs 109; P = .36), with a minor isolated difference in motor coordination scores.

    CONCLUSIONS: Our data do not suggest long-term negative effects of neonatal mild TSH elevation. TSH elevation below the screen threshold appears largely transient, and midchildhood neurocognitive performance of these children was similar to their siblings. We propose that associations between neonatal mild TSH elevation and IQ are due to familial confounders. We caution against the practice of reducing screening CH cutoffs to levels at which the diagnosis may not offer long-term benefit for those detected.

    Matched MeSH terms: Reference Values
  5. Ho JPY, Merican AM, Hashim MS, Abbas AA, Chan CK, Mohamad JA
    J Arthroplasty, 2017 10;32(10):3176-3183.
    PMID: 28579444 DOI: 10.1016/j.arth.2017.04.060
    BACKGROUND: The posterior tibial slope (PTS) is an important consideration in knee arthroplasty. However, there is still no consensus for the optimal slope. The objectives of this study were (1) to reliably determine the native PTS in this population using 3-dimensional computed tomography scans and (2) to determine the normal reference range for PTS in this population.

    METHODS: One hundred computed tomography scans of disease-free knees were analyzed. A 3-dimensional reconstructed image of the tibia was generated and aligned to its anatomic axis in the coronal and sagittal planes. The tibia was then rotationally aligned to the tibial plateau (tibial centroid axis) and PTS was measured from best-fit planes on the surface of the proximal tibia and individually for the medial and lateral plateaus. This was then repeated with the tibia rotationally aligned to the ankle (transmalleolar axis).

    RESULTS: When rotationally aligned to the tibial plateau, the mean PTS, medial PTS, and lateral PTS were 11.2° ± 3.0 (range, 4.7°-17.7°), 11.3° ± 3.2 (range, 2.7°-19.7°), and 10.9° ± 3.7 (range, 3.5°-19.4°), respectively. When rotationally aligned to the ankle, the mean PTS, medial PTS, and lateral PTS were 11.4° ± 3.0 (range, 5.3°-19.3°), 13.9° ± 3.7 (range, 3.1°-24.4°), and 9.7° ± 3.6 (range, 0.8°-17.7°), respectively.

    CONCLUSION: The PTS in the normal Asian knee is on average 11° (mean) with a reference range of 5°-17° (mean ± 2 standard deviation). This has implications to surgery and implant design.

    Matched MeSH terms: Reference Values
  6. Singh R, Singh HJ, Sirisinghe RG
    Jpn. J. Physiol., 1992;42(3):407-14.
    PMID: 1434102
    Spirometry was performed on 614 female subjects ranging in age from 13 to 69 years and comprising all the main races in Malaysia. They were divided into six age categories. Mean forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1) were 2.51 +/- 0.02 and 2.31 +/- 0.02l, respectively. Both FVC and FEV1 correlated negatively with age. Regression analysis revealed an age-related decline in FVC of 220 ml per decade of life. Multiple stepwise regression of the data for the prediction of an individual's FVC above the age of 20 years gave an equation: FVC(l) = 0.0312 (height)-0.022 (age)-1.64. Predicted FVC values derived from equations based on other populations were considerably higher than the observed mean in this study. Our study, therefore, reemphasizes the need to be cautious when applying formulae derived from one population to another. Grossly erroneous conclusions may be reached unless predicted equations for lung-function tests for a given population group are derived from studies based on the same population group.
    Matched MeSH terms: Reference Values
  7. Johan A, Chan CC, Chia HP, Chan OY, Wang YT
    Eur Respir J, 1997 Dec;10(12):2825-8.
    PMID: 9493668
    Maximal static inspiratory and expiratory mouth pressures (PI,max and PE,max, respectively) enable the noninvasive measurement of global respiratory muscle strength. The aim of this study was primarily to obtain normal values of PI,max and PE,max for adult Chinese, Malays and Indians and, secondarily, to study their effect on lung volumes in these subjects. Four hundred and fifty two healthy subjects (221 Chinese, 111 Malays, 120 Indians) were recruited. Measurements of PI,max from residual volume (RV), PE,max from total lung capacity (TLC) and forced vital capacity (FVC) were obtained in the seated position. There were significant ethnic differences in PI,max and PE,max measurements obtained in males, and FVC measurements in both males and females. Chinese males had higher PI,max values (mean (+/-SD) 88.7+/-32.5 cmH2O) and higher PE,max values (113.4+/-41.5) than Malay males (PI,max 74.0+/-22.7 cmH2O, PE,max 94.7+/-23.4 cmH2O). Chinese males had higher PE,max than Indian males (PI,max = 83.7+/-30.0 cmH2O, PE,max 98.4+/-29.2 cmH2O). There were no significant differences among Chinese females (PI,max 53.6+/-2.3 cmH2O, PE,max 68.3+/-24.0 cmH2O), Malay females (PI,max 50.7+/-18.3 cmH2O, PE,max 63.6+/-21.6 cmH2O) and Indian females (PI,max 50.0+/-15.2 cmH2O, PE,max 60.7+/-20.4 cmH2O). In both sexes, the Chinese had a higher FVC compared with Malays and Indians. After adjusting for age, height and weight, race was still a determinant for PE,max in males, and FVC in both sexes. The FVC only correlated weakly with PI,max and PE,max in both sexes. Ethnic differences in respiratory muscle strength, and lung volumes, occur among Asians. However, respiratory muscle strength does not explain the differences in lung volumes in healthy Asian subjects.
    Matched MeSH terms: Reference Values
  8. Ng KH, Rassiah P, Wang HB, Hambali AS, Muthuvellu P, Lee HP
    Br J Radiol, 1998 Jun;71(846):654-60.
    PMID: 9849390
    A collaborative national survey initiated by the University of Malaya and the Ministry of Health was conducted from 1993 to 1995 to establish baseline patient dose data for seven common types (12 projections) of X-ray examinations in Malaysia. A total of 12 randomly selected public hospitals and 867 patients were included in this survey. The entrance surface doses (ESD) received by the patients were measured using thermoluminescent dosemeters (TLDs) attached to the patient's skin. Histograms are presented showing wide, positively skewed distributions of measured entrance surface doses for each examination. Mean, median, first and third quartile values of ESD and median effective dose are reported. Survey results are generally comparable with those reported in the UK, USA and by the International Atomic Energy Agency (IAEA). The results also provide information on dose level for a lower weight population (mean weight 60 kg) compared with the international reference dose values based on a 70 kg standard. The findings support the importance of the on-going national quality assurance programme to ensure doses are kept to a level consistent with optimum image quality. The data will also be useful for the formulation of national guidance levels as recommended by the IAEA. Furthermore, this study provides patient dosimetry information on healthcare level II countries.
    Matched MeSH terms: Reference Values
  9. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Ng KH
    Br J Radiol, 2018 Sep;91(1089):20180235.
    PMID: 29869920 DOI: 10.1259/bjr.20180235
    OBJECTIVE: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR).

    METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.

    RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).

    CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.

    Matched MeSH terms: Reference Values
  10. Liu A, Byrne NM, Kagawa M, Ma G, Poh BK, Ismail MN, et al.
    Br J Nutr, 2011 Nov;106(9):1390-7.
    PMID: 21736824 DOI: 10.1017/S0007114511001681
    Overweight and obesity in Asian children are increasing at an alarming rate; therefore a better understanding of the relationship between BMI and percentage body fat (%BF) in this population is important. A total of 1039 children aged 8-10 years, encompassing a wide BMI range, were recruited from China, Lebanon, Malaysia, The Philippines and Thailand. Body composition was determined using the 2H dilution technique to quantify total body water and subsequently fat mass, fat-free mass and %BF. Ethnic differences in the BMI-%BF relationship were found; for example, %BF in Filipino boys was approximately 2 % lower than in their Thai and Malay counterparts. In contrast, Thai girls had approximately 2.0 % higher %BF values than in their Chinese, Lebanese, Filipino and Malay counterparts at a given BMI. However, the ethnic difference in the BMI-%BF relationship varied by BMI. Compared with Caucasian children of the same age, Asian children had 3-6 units lower BMI at a given %BF. Approximately one-third of the obese Asian children (%BF above 25 % for boys and above 30 % for girls) in the study were not identified using the WHO classification and more than half using the International Obesity Task Force classification. Use of the Chinese classification increased the sensitivity. Results confirmed the necessity to consider ethnic differences in body composition when developing BMI cut-points and other obesity criteria in Asian children.
    Matched MeSH terms: Reference Values
  11. Othman SS, Abdul Kadir K, Hassan J, Hong GK, Singh BB, Raman N
    Aust N Z J Psychiatry, 1994 Dec;28(4):620-4.
    PMID: 7794205
    The thyroid status of 249 patients with chronic schizophrenia (males = 136, females = 113) with a median age of 36 years (range: 16 to 58 years) and a median duration of hospitalisation of 10 years (range: 1 to 30 years) was assessed. Thyroid antibodies (TAb) were found in 51 patients (20%). In female patients, 32 (28%) were TAb positive compared to 13% (n = 152, p = 0.01) in healthy female blood donors. In male patients, the prevalence of TAb was 14% compared to 7% (n = 449, p = 0.01) in healthy male blood donors. Of the 183 patients who had thyroid hormone measurements, 60% had normal test, 5% had elevated TSH and 17% had low TSH. The T4, FT41 and FT31 were significantly lower in those with low or high TSH (p < 0.001) compared to those with normal TSH. Of the 143 patients with normal TSH, 33 (23%) had low T3. In conclusion, there is a spectrum of thyroid function test abnormalities in chronic schizophrenia; this may be related to an abnormality in the central regulation of the hypothalamo-pituitary thyroid axis as well as at the peripheral level. However the association between chronic schizophrenia and the presence of thyroid antibodies, and the clinical relevance of these biochemical abnormalities, are still not clear.
    Matched MeSH terms: Reference Values
  12. Yusoff NM, Abdullah WZ, Ghazali S, Othman MS, Baba AA, Abdullah N, et al.
    Aust N Z J Obstet Gynaecol, 2002 May;42(2):164-6.
    PMID: 12069143 DOI: 10.1111/j.0004-8666.2002.00164.x
    OBJECTIVES: The objectives of this study were to investigate the prevalence of factor V Leiden mutation in Malay women with recurrent spontaneous abortion and to clarify the contribution of the factor V Leiden mutation to recurrent miscarriages in these women.

    DESIGN: A prospective case control study between June 1999 and April 2000.

    SETTING: Hospital University Science of Malaysia, Kubang Kerian, Kelantan, and Maternal and Child Health Clinic, Pasir Mas, Kelantan, Malaysia.

    SAMPLES: A total of 46 Malay women with a history of three or more first or second trimester miscarriages were studied. The control group consisted of 46 parous women without obstetric complications.

    METHODS: Diagnosis of factor V Leiden mutation was made by examination of factor V Leiden allele product following Mnl I digestion of factor V Leiden alleles amplified by polymerase chain reaction.

    RESULTS: None of the 46 women with recurrent spontaneous abortion carried the mutation. Also, we found no subject carrying the factor V Leiden alleles in the control group.

    CONCLUSION: These results suggest that that there is no association between the factor V Leiden mutation and recurrent spontaneous abortion in the Malay population.
    Matched MeSH terms: Reference Values
  13. Tan PC, Ling LP, Omar SZ
    Aust N Z J Obstet Gynaecol, 2007 Jun;47(3):191-7.
    PMID: 17550485 DOI: 10.1111/j.1479-828X.2007.00717.x
    Background: The best method of screening for gestational diabetes (GDM) remains unsettled. The 50-g glucose challenge test (GCT) is used in a two-stage screening process but its best threshold value can vary according to population.

    Aims: To evaluate the role of risk factors in conjunction with GCT and to determine an appropriate threshold for the one-hour venous plasma glucose with the GCT.

    Method: In a prospective study, 1600 women at antenatal booking without a history of diabetes mellitus or GDM filled a form on risk factors before GCT. Women who had GCT >or= 7.2 mmol/L underwent the 75-g oral glucose tolerance test (OGTT). GDM was diagnosed according to WHO (1999) criteria.

    Result: Thirty-five per cent had GCT >or= 7.2 mmol/L, 32.6% underwent OGTT and 34.5% of OGTT confirmed GDM. The GDM rate in our population was at least 11.4%. Examination of the receiver operator characteristic curve suggested that the best threshold value for the GCT in our population was >or= 7.6 mmol/L. Multivariable logistic regression demonstrated that only GCT >or= 7.6 mmol/L was an independent predictor for GDM (adjusted odds ratio 3.7: P < 0.001). After GCT, maternal age and anthropometry, OGTT during the third trimester, family history, obstetric history and glycosuria were not independent predictors of GDM.

    Conclusions: Risk factors were not independent predictors of GDM in women with GCT >or= 7.2 mmol/L. GCT threshold value >or= 7.6 mmol is appropriate for the Malaysian population at high risk of GDM.
    Matched MeSH terms: Reference Values
  14. Jothee S, Shafie MS, Vijayaretnam SV, Nor FM
    Am J Forensic Med Pathol, 2020 Jun;41(2):110-114.
    PMID: 32205487 DOI: 10.1097/PAF.0000000000000539
    Organ weights are routinely measured during autopsies as a crude screening tool to detect possible organ pathology. In several centers, inclusion of major organ weights indicates whether an autopsy report has achieved its standard of practice, which in turn should be subjected to an audit. Previous studies show statistical variation in organ weights across different populations. Malaysian pathologists have relied on Western data and crude subjective determination in the interpretation of normal organ weights. Hence, the need for a reference range as a guide for pathologists is acute. Organ weights from traumatic deaths between 2004 and 2017 were analyzed in the UKM Medical Centre. Statistical analysis was performed to form reference ranges for normal weights of the brain, heart, lung, liver, spleen, and kidneys. In addition, the data were compared between sexes, races, and body mass index values to determine whether organ weights were affected by these parameters. In this study, reference ranges for organ weights are presented for Malaysian adult men and women.
    Matched MeSH terms: Reference Values
  15. Chong SY, Chong LA, Ariffin H
    Am J Emerg Med, 2010 Jun;28(5):603-6.
    PMID: 20579557 DOI: 10.1016/j.ajem.2009.02.006
    The aim of this study is to formulate an accurate estimate of the spinal needle depth for a successful lumbar puncture in pediatric patients.
    Matched MeSH terms: Reference Values
  16. Ahmad Fuzi SF, Koller D, Bruggraber S, Pereira DI, Dainty JR, Mushtaq S
    Am J Clin Nutr, 2017 Dec;106(6):1413-1421.
    PMID: 29046302 DOI: 10.3945/ajcn.117.161364
    Background: Tea has been shown to be a potent inhibitor of nonheme iron absorption, but it remains unclear whether the timing of tea consumption relative to a meal influences iron bioavailability.Objective: The aim of the study was to investigate the effect of a 1-h time interval of tea consumption on nonheme iron absorption in an iron-containing meal in a cohort of iron-replete, nonanemic female subjects with the use of a stable isotope (57Fe).Design: Twelve women (mean ± SD age: 24.8 ± 6.9 y) were administered a standardized porridge meal extrinsically labeled with 4 mg 57Fe as FeSO4 on 3 separate occasions, with a 14-d time interval between each test meal (TM). The TM was administered with water (TM-1), with tea administered simultaneously (TM-2), and with tea administered 1 h postmeal (TM-3). Fasted venous blood samples were collected for iron isotopic analysis and measurement of iron status biomarkers. Fractional iron absorption was estimated by the erythrocyte iron incorporation method.Results: Iron absorption was 5.7% ± 8.5% (TM-1), 3.6% ± 4.2% (TM-2), and 5.7% ± 5.4% (TM-3). Mean fractional iron absorption was found to be significantly higher (2.2%) when tea was administered 1 h postmeal (TM-3) than when tea was administered simultaneously with the meal (TM-2) (P = 0.046). An ∼50% reduction in the inhibitory effect of tea (relative to water) was observed, from 37.2% (TM-2) to 18.1% (TM-3).Conclusions: This study shows that tea consumed simultaneously with an iron-containing porridge meal leads to decreased nonheme iron absorption and that a 1-h time interval between a meal and tea consumption attenuates the inhibitory effect, resulting in increased nonheme iron absorption. These findings are not only important in relation to the management of iron deficiency but should also inform dietary advice, especially that given to those at risk of deficiency. This trial was registered at clinicaltrials.gov as NCT02365103.
    Matched MeSH terms: Reference Values
  17. Fairus S, Nor RM, Cheng HM, Sundram K
    Am J Clin Nutr, 2006 Oct;84(4):835-42.
    PMID: 17023711
    BACKGROUND: The detection of tocotrienols in human plasma has proven elusive, and it is hypothesized that they are rapidly assimilated and redistributed in various mammalian tissues.

    OBJECTIVE: The primary study objective was to evaluate the postprandial fate of tocotrienols and alpha-tocopherol in human plasma and lipoproteins.

    DESIGN: Seven healthy volunteers (4 males, 3 females) were administered a single dose of vitamin E [1011 mg palm tocotrienol-rich fraction (TRF) or 1074 mg alpha-tocopherol] after a 7-d conditioning period with a tocotrienol-free diet. Blood was sampled at baseline (fasted) and 2, 4, 5, 6, 8, and 24 h after supplementation. Concentrations of tocopherol and tocotrienol isomers in plasma, triacylglycerol-rich particles (TRPs), LDLs, and HDLs were measured at each interval.

    RESULTS: After intervention with TRF, plasma tocotrienols peaked at 4 h (4.79 +/- 1.2 microg/mL), whereas alpha-tocopherol peaked at 6 h (13.46 +/- 1.68 microg/mL). Although tocotrienols were similarly detected in TRPs, LDLs, and HDLs, tocotrienol concentrations were significantly lower than alpha-tocopherol concentrations. In comparison, plasma alpha-tocopherol peaked at 8 h (24.3 +/- 5.22 microg/mL) during the alpha-tocopherol treatment and emerged as the major vitamin E isomer detected in plasma and lipoproteins during both the TRF and the alpha-tocopherol treatments.

    CONCLUSIONS: Tocotrienols are detected in postprandial plasma, albeit in significantly lower concentrations than is alpha-tocopherol. This finding confirms previous observations that, in the fasted state, tocotrienols are not detected in plasma. Tocotrienol transport in lipoproteins appears to follow complex biochemically mediated pathways within the lipoprotein cascade.

    Matched MeSH terms: Reference Values
  18. Yusof MI, Shamsi SS
    Surg Radiol Anat, 2012 Apr;34(3):203-7.
    PMID: 21947622 DOI: 10.1007/s00276-011-0869-8
    Cervical translaminar screw fixation has been shown to be safe, efficient and provides alternative for cervical fixation. However, its use in the Asian population should be considered cautiously because the cervical lamina diameter may not be adequate to accommodate the standard lamina screw size. We studied the average transverse lamina diameter of the cervical spine in the Malaysian population to evaluate the feasibility and safety of lamina screw fixation in this population.
    Matched MeSH terms: Reference Values
  19. Kwan MK, Jeffry A, Chan CY, Saw LB
    Surg Radiol Anat, 2012 Apr;34(3):217-27.
    PMID: 22194086 DOI: 10.1007/s00276-011-0919-2
    Studies of sacral pedicle anatomy have been reported in the European population. However, the feasibility for the use of S1, S2 and S2-ilium screws has not been fully investigated in the Asian population.
    Matched MeSH terms: Reference Values
  20. Abdullah B, Rajet KA, Abd Hamid SS, Mohammad WM
    Sleep Breath, 2011 Dec;15(4):747-54.
    PMID: 20957444 DOI: 10.1007/s11325-010-0431-7
    OBJECTIVES: We aimed to evaluate the severity of upper airway obstruction at the retropalatal and retroglossal regions in obstructive sleep apnea (OSA) patients.

    METHODOLOGY: This is a descriptive cross-sectional study at the Sleep Clinic, Department of Otorhinolaryngology-Head and Neck Surgery. Flexible nasopharyngolaryngoscopy was performed in seated erect and supine position. Retropalatal and retroglossal regions were continuously recorded during quiet breathing and Mueller's maneuver in both positions. Captured images were measured using Scion Image software and narrowing rate was calculated. Level of each site was classified based on Fujita classification and severity of obstruction using Sher scoring system for Mueller's maneuver.

    RESULTS: A total of 59 patients participated in this study. Twenty-nine (49.2%) participants had type 1 (retropalatal) obstruction, 23 (38.9%) had type 2 (retropalatal and retroglossal), and seven (11.9%) in type 3 (retroglossal) obstruction. Fifty (84.7%) of the patients have severe obstruction at the retropalatal region in supine position (SRP) followed by 35 (59.3%) at retropalatal region in erect position (ERP), 27 (45.8%) at retroglossal region in supine position (SRG) and eight (13.5%) at retroglossal region in erect position (ERG). The average oxygen saturation showed significant association in ERP (P = 0.012) and SRP (P < 0.001), but not significant in ERG and SRG.

    CONCLUSIONS: Videoendoscopy utilizing flexible nasopharyngolaryngoscopy and Scion Image software is reliable, minimally invasive, and useful as an office procedure in evaluating the multilevel obstruction of upper airway in OSA patients. The retropalatal region has more severe obstruction compared with retroglossal region either in erect or supine position.

    Matched MeSH terms: Reference Values
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links