Methods: Manual sample size calculation using Microsoft Excel software and sample size tables were tabulated based on a single coefficient alpha and the comparison of two coefficients alpha.
Results: For a single coefficient alpha test, the approach by assuming the Cronbach's alpha coefficient equals to zero in the null hypothesis will yield a smaller sample size of less than 30 to achieve a minimum desired effect size of 0.7. However, setting the coefficient of Cronbach's alpha larger than zero in the null hypothesis could be necessary and this will yield larger sample size. For comparison of two coefficients of Cronbach's alpha, a larger sample size is needed when testing for smaller effect sizes.
Conclusions: In the assessment of the internal consistency of an instrument, the present study proposed the Cronbach's alpha's coefficient to be set at 0.5 in the null hypothesis and hence larger sample size is needed. For comparison of two coefficients' of Cronbach's alpha, justification is needed whether testing for extremely low and extremely large effect sizes are scientifically necessary.
METHODS: A cross-sectional study was conducted to evaluate the corneal cell morphology of 47 keratoconus patients and 32 healthy eyes without any ocular disease. New keratoconus patients with different disease severities and without any other ocular co-morbidity were recruited from the ophthalmology department of a public hospital in Malaysia from June 2013 to May 2014. Corneal cell morphology was evaluated using an in vivo slit-scanning confocal microscope. Qualitative and quantitative data were analysed using a grading scale and the Nidek Advanced Visual Information System software, respectively.
RESULTS: The corneal cell morphology of patients with keratoconus was significantly different from that of healthy eyes except in endothelial cell density (P = 0.072). In the keratoconus group, increased level of stromal haze, alterations such as the elongation of keratocyte nuclei and clustering of cells at the anterior stroma, and dark bands in the posterior stroma were observed with increased severity of the disease. The mean anterior and posterior stromal keratocyte densities and cell areas among the different stages of keratoconus were significantly different (P < 0.001 and P = 0.044, respectively). However, the changes observed in the endothelium were not significantly different (P > 0.05) among the three stages of keratoconus.
CONCLUSION: Confocal microscopy observation showed significant changes in corneal cell morphology in keratoconic cornea from normal healthy cornea. Analysis also showed significant changes in different severities of keratoconus. Understanding the corneal cell morphology changes in keratoconus may help in the long-term monitoring and management of keratoconus.
Methods: A two-way repeated measures study was conducted on 14 healthy older adults and 14 older adults with balance impairment, who were recruited from the community in Chiang Rai, Thailand. Their walking performance was assessed using a four-metre walking test at their preferred gait speed and while walking under two further gait conditions, in randomised order: dual task walking and dual task walking with a simulated traffic light. Each participant was tested individually, with the testing taking between 15 and 20 minutes to perform, including two-minute rest periods between walking conditions. Two Kinect cameras recorded the spatio-temporal parameters using MFU gait analysis software. Each participant was tested for each condition twice. The mean parameters for each condition were analysed using a two-way repeated measures analysis of variance (ANOVA) with participant group and gait condition as factors.
Result: There was no significant between-group effect for walking speed, stride length and cadence. There were also no significant effects between gait condition and stride length or cadence. However, the effect between gait condition and walking speed was found to be significant [F(1.557, 40.485) = 4.568,P= 0.024, [Formula: see text]].
Conclusion: An audio-visual cue (simulated traffic light) was found to influence walking speed in both healthy older adults and in older adults with balance impairment. The results suggest that audio-visual cues could be incorporated into healthy lifestyle promotion in older adults with balance impairment.
PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.
MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.
RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P
PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.
MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).
RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.
CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.
METHODS: Sixteen computed tomography scan of SC patients (8 months-6 years old) were imported to Materialise Interactive Medical Image Control System (MIMICS) and Materialise 3-matics software. Three-dimensional (3D) OC models were fabricated, and linear measurements were obtained. Mathematical formulas were used for calculation of OC volume and surface area from the 3D model. The same measurements were obtained from the software and used as ground truth. Data normality was investigated before statistical analyses were performed. Wilcoxon test was used to validate differences of OC volume and surface area between 3D model and software.
RESULTS: The mean values for OC surface area for 3D model and MIMICS software were 103.19 mm2 and 31.27 mm2, respectively, whereas the mean for OC volume for 3D model and MIMICS software were 184.37 mm2 and 147.07 mm2, respectively. Significant difference was found between OC volume (P = 0.0681) and surface area (P = 0.0002) between 3D model and software.
CONCLUSION: Optic canal in SC is not a perfect conical frustum thus making 3D model measurement and mathematical formula for surface area and volume estimation not ideal. Computer software remains the best modality to gauge dimensional parameter and is useful to elucidates the relationship of OC and eye function as well as aiding intervention in SC patients.
METHODS: A computer-based SG (CBSG) tool was developed using Microsoft® PowerPoint 2007 to value asthma-specific health states in Malaysia. Eight hypothetical health states were considered, including two anchor states (healthy and dead), three chronic (C) states and three temporary (T) states (each numbered 1 through 3, with increasing severity) in addition to the subject's current health state. Twenty adult asthma patients completed the CBSG tool in addition to paper-based Asthma Control Test, three health status measures (EQ-5D, EQ-VAS, and Mini Asthma Quality of Life Questionnaire (MiniAQLQ)), and VAS utility assessment tool. Patients and interviewers rated the difficulty of the VAS and CBSG tools. Correlations between current health state values derived from the various measures were determined.
RESULTS: The SG and the VAS received similar difficulty ratings. 17 patients completed the CBSG tool within 30 minutes. The mean utilities determined by the CBSG tool for the T1-T3 asthma health states met the expected logical order of 1>2>3, but those for the C1-C3 states did not. Correlation between current health state values derived from the CBSG tool and other measurement tools was poor.
CONCLUSION: The CBSG tool developed for measuring utilities of asthma health states showed acceptable feasibility and overall validity.
METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.
RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).
CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.
METHODS: Articles in this review referenced EA, were peer-reviewed or gray literature reports published in 2010 to 2016 in English, and were identified using PubMed, Scopus, Web of Science, and Google Scholar.
RESULTS: Fourteen articles described EA use in LMICs. India, Sierra Leone, South Africa, Mozambique, and Rwanda reported building the system to meet country needs and implement a cohesive HIS framework. Jordan and Taiwan focused on specific HIS aspects, ie, disease surveillance and electronic medical records. Five studies informed the context. The Millennium Villages Project employed a "uniform but contextualized" approach to guide systems in 10 countries; Malaysia, Indonesia, and Tanzania used interviews and mapping of existing components to improve HIS, and Namibia used of Activity Theory to identify technology-associated activities to better understand EA frameworks. South Africa, Burundi, Kenya, and Democratic Republic of Congo used EA to move from paper-based to electronic systems.
CONCLUSIONS: Four themes emerged: the importance of multiple sectors and data sources, the need for interoperability, the ability to incorporate system flexibility, and the desirability of open group models, data standards, and software. Themes mapped to EA frameworks and operational components and to health system building blocks and goals. Most articles focused on processes rather than outcomes, as countries are engaged in implementation.