Displaying publications 61 - 80 of 150 in total

Abstract:
Sort:
  1. Das S, Othman F, Suhaimi FH, Latiff AA
    Rom J Morphol Embryol, 2008;49(3):421-3.
    PMID: 18758652
    An abnormal communication between an artery and a vein is known as arteriovenous malformation (AVM) or arteriovenous fistula (AVF). The AVM or the AVF might be congenital in origin or even acquired. The arteriovenous communications are usually surgically made in patients undergoing repeated hemodialysis, while suffering from any chronic renal disease. The abnormal arteriovenous communications may be asymptomatic in nature. The arteriovenous communications might be an incidental finding during any anatomical dissections or medico-legal autopsies. The present study reports the presence of BBC on both sides of a 54-year-old male cadaver who died of road traffic accident. There was a communication between the brachial artery and the brachial vein, 11.5 cm above the medial epicondyle. The oblique communicating channel measured 1.5 cm in length and connected the brachial artery to the brachial vein. A detailed histological study of the communication showed the presence of thick tunica media. Knowledge of arteriovenous communications may be beneficial for any academic studies and equally important for vascular surgeons and radiologists performing angiographic studies.
    Matched MeSH terms: Cadaver
  2. Lee HL
    Malays J Pathol, 1996 Dec;18(2):125-7.
    PMID: 10879234
    Forensically important entomological specimens recovered from 95 forensic cases of human cadavers from April 1993 to May 1996 in Malaysia were identified and analysed. The results indicated that 73.7% of these specimens were Chrysomya species, occurring either as single or mixed infestations. Of these, the most prominent species were Ch megacephala (F.) and Ch rufifacies (Macquart). Other fly maggots recovered included Sarcophaga spp., Lucilia spp. and Hermetia spp., mostly occurring together with other calliphorine flies. A member of Muscidae fly, Ophyra spp. was also recovered for the first time.
    Matched MeSH terms: Cadaver*
  3. Lee HL
    Malays J Pathol, 1989 Aug;11:33-6.
    PMID: 2632998
    A total of 101 entomological specimens recovered from human cadavers were processed and studied. Analysis of the data indicated that about 95% of these specimens were maggots of flies. Maggots of the blowfly Chrysomya (Family: Calliphoridae) especially Ch. rufifacis and Ch. megacephala were predominantly found in 77 cases (76.2%) while larvae of several other flies of the genera Sarcophaga, Calliphora, Lucilia and hermetia were also recovered. It was notable that Musca domestica or other related flies were not found in all these specimens. The age of these larvae was useful in the determination of the minimum time lapsed after death. However, more biological studies on animal carcases should be conducted for more accurate determinations. Methods of collection, preservation and despatching of specimens were also discussed.
    Matched MeSH terms: Cadaver*
  4. Nazni WA, Jeffery J, Sa'diyah I, Noorjuliana WM, Chen CD, Rohayu SA, et al.
    Trop Biomed, 2008 Aug;25(2):173-5.
    PMID: 18948890
    Piophila casei (Linnaeus) (Diptera: Piophilidae) is reported from human cadavers in two separate forensic cases for the first time in Malaysia. Both bodies were found indoors. The first case, was that of a male of unknown nationality and age and also contained maggots of the muscid Ophyra spinigera (Stein). The second case was a female Chinese whose body also contained other species of maggots but these were not identifiable.
    Matched MeSH terms: Cadaver*
  5. Kwan MK, Chan CY, Saw LB, Rukmanikanthan S, Lenke LG
    Clin Spine Surg, 2017 04;30(3):E297-E304.
    PMID: 28323715 DOI: 10.1097/BSD.0b013e3182aab29d
    STUDY DESIGN: Cadaveric and biomechanical study.

    OBJECTIVE: The aim of this study was to assess the safety and pullout strength of medial, partial nonthreaded thoracic pedicle screws compared with conventional screws.

    SUMMARY OF BACKGROUND DATA: The perforation rate of the pedicle screws has been reported as high as 41%. Nerve injury and irritation can result from the compression of malpositioned screw on neural structures.

    METHODS: Ten fresh cadavers were studied. Screws, 5.0 and 6.0 mm, were inserted from T1 to T6 and T7 to T12, respectively. Pedicle perforations and fractures were recorded upon screw insertion and final positioning (nonthreaded portion facing medially) after a wide laminectomy. Pullout strength of novel and conventional screws were then tested using an Instron machine in an artificial bone substitute.

    RESULTS: A total of 240 thoracic pedicle screws were inserted. Of them, 88.8% (213 screws) were fully contained during screw insertion. There were 5.0% (12 screws) grade 1 medial perforations and 6.2% (15 screws) grade 1 lateral perforations during screw insertion. Upon final positioning, 93.8% (225 screws) were fully contained. All grade 1 medial perforations, which occurred during insertion, were converted to grade 0. No dural or nerve root injuries occurred. Pedicle split fractures were noted in 6.7% (16 screws). The use of medial, partial nonthreaded screws reduced the overall perforation rate from 11.2% to 6.2%. The mean pullout load for the 5 mm fully threaded screw versus medial, partial nonthreaded was 1419.3±106.1 N (1275.8-1538.8 N) and 1336.6±44.2 N (1293.0-1405.1 N) respectively, whereas 6 mm pullout load averaged 2126.0±134.8 N (1986.3-2338.3 N) and 2036.5±210.0 N (1818.4-2355.9 N). The difference was not statistically significant.

    CONCLUSIONS: The use of medial, partial nonthreaded pedicle screws reduced the medial perforation rate from 5.0% to 0%; however, the pullout strength was not significantly reduced. The use of this novel screw can potentially reduce the incidence of nerve injury or irritation after medial pedicle perforations.

    Matched MeSH terms: Cadaver
  6. Vathsala A, Lee WT, Lim CH
    Transplant Proc, 1994 Oct;26(5):2507-8.
    PMID: 7940768
    Matched MeSH terms: Cadaver
  7. Morad Z, Lim TO
    Transplant Proc, 2000 Nov;32(7):1485-6.
    PMID: 11119799
    Matched MeSH terms: Cadaver
  8. Tan SY, Lim CS, Teo SM, Lee SH, Razack A, Loh CS
    Med J Malaysia, 2003 Dec;58(5):769-70.
    PMID: 15190667
    We report here a case of a kidney transplant recipient in whom the ureter was initially implanted into the peritoneum. Excessive ultrafiltration volume and reversal of serum vs dialysate creatinine ratio when the patient was recommenced on continuous ambulatory peritoneal dialysis first suggested the diagnosis which was subsequently confirmed by a plain abdominal x-ray demonstrating placement of ureteric stent in the peritoneum. This rare complication was successfully corrected with surgical re-implantation of ureter into the bladder and 5 years later, the patient remains well with good graft function.
    Matched MeSH terms: Cadaver
  9. Chiu SF, Wong HS, Morad Z, Loo LH
    Transplant Proc, 2004 Sep;36(7):2030-1.
    PMID: 15518734
    To examine the quality of life in cadaver (CAD) and living-related (LRRT) renal transplant recipients.
    Matched MeSH terms: Cadaver
  10. Thwin SS, Soe MM, Myint M, Than M, Lwin S
    Singapore Med J, 2010 Feb;51(2):e40-2.
    PMID: 20358142
    We report a unique variation in the origin and branches of both the left and right external carotid artery (ECA) found during the dissection of a human cadaver. Knowledge of the possible anatomical variations of the ECA is especially important in facio-maxillary and neck surgeries. Surgeons need to be aware of the possibility of encountering such variations, as they may lead to difficulties in differentiating between the external and internal carotid arteries, and in identifying the branches and origins. This knowledge is also important for radiologists in the image interpretation of the face and neck regions.
    Matched MeSH terms: Cadaver
  11. Jusoh AR, Abd Rahman N, Abd Latiff A, Othman F, Das S, Abd Ghafar N, et al.
    Rom J Morphol Embryol, 2010;51(1):163-6.
    PMID: 20191138
    The obturator artery (OA) originates from the internal iliac artery. Variation in the origin of the OA may be asymptomatic in individuals and occasionally be detected during routine cadaveric dissections or autopsies. In the present study, we observed the origin and the branching pattern of the OA on 34 lower limbs (17 right sides and 17 left sides) irrespective of sex. The bifurcation of the common iliac artery into internal and external iliac from the sacral ala varied between 4.3-5.3 cm. The distance of the origin of the anterior division of internal iliac artery from the bifurcation of common iliac artery varied between 1-6 cm. The distance of the origin of the posterior division of the internal iliac artery from the point of bifurcation of the common iliac artery varied between 0-6 cm. Out of 34 lower limbs studied, two specimens (5.8%) showed anomalous origin of the OA originating from the posterior division of the internal iliac artery. Of these two, one limb belonged to the right side while the other was from the left side. The anomalous OA gave off an inferior vesical branch to the prostate in both the specimens. No other associated anomalies regarding the origin or branching pattern of the OA were observed. Prior knowledge of the anatomical variations may be beneficial for vascular surgeons ligating the internal iliac artery or its branches and the radiologists interpreting angiograms of the pelvic region.
    Matched MeSH terms: Cadaver
  12. Nordin NH, Ahmad UK, Abdul Rahim NA, Kamaluddin MR, Ismail D, Muda NW, et al.
    Trop Biomed, 2020 Jun 01;37(2):333-356.
    PMID: 33612803
    In addition to the scarcity of forensic entomology baseline data on oviposition of necrophagous insects and completion of their life cycles in the Borneo region, similar data derived from caves remain unreported. Since entomological baseline data can differ from one biogeoclimatic region to another, the lack of such data would limit the practical values of applying entomological evidence in estimating minimum postmortem interval (mPMI). Therefore, this present research that investigated oviposition and completion of life cycles of necrophagous flies infesting rabbit carcasses decomposing in Mount Kapur Cave and its surrounding forest habitat in Kuching, Sarawak merits forensic consideration. In general, 13 taxa of necrophagous flies were identified viz. Hypopygiopsis violacea, Hypopygiopsis fumipennis, Hemipyrellia ligurriens, Hemipyrellia tagaliana, Chrysomya megacephala, Chrysomya villeneuvi, Chrysomya rufifacies, Chrysomya chani, Chrysomya pinguis, Chrysomya nigripes, Ophyra spinigera and Ophyra chalcogaster, as well as unidentified Sarcophagidae. In addition, Hyp. violacea and Hyp. fumipennis were the two earlier necrophagous flies that oviposited in all rabbit carcasses decomposing in both habitats. While all these necrophagous flies were observed infesting carcasses in Mount Kapur Cave, Hem. ligurriens and Hem. tagaliana were not found infesting carcasses in the surrounding forest habitat. Complete life cycles for six and five different necrophagous fly species were successfully observed in Mount Kapur Cave and its surrounding forest habitat, respectively. Significant delay in oviposition, as well as longer durations for completing the life cycles in several necrophagous fly species were observed in Mount Kapur Cave when compared with those of surrounding forest habitat (p < 0.05). These findings deserve consideration as the first ever forensic empirical baseline data on oviposition and completion of life cycles for necrophagous flies in Sarawak as well as in a cave habitat, in view of its practical values for estimating mPMI for forensic practical caseworks.
    Matched MeSH terms: Cadaver
  13. Khoo LS, Lai PS, Saidin MH, Noor Z, Mahmood MS
    Forensic Sci Int, 2018 Jul;288:242-255.
    PMID: 29783180 DOI: 10.1016/j.forsciint.2018.04.017
    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later.
    Matched MeSH terms: Cadaver
  14. Khoo LS, Mahmood MS
    PMID: 32412001 DOI: 10.1016/j.fsisyn.2020.01.003
    This study explores the practicability and usability of the cling film plastic wrap on the dead body with decomposition changes, whereby the feasibility of wrapping the remains to ensure the containment of the decomposition fluid within the cling film plastic wrap. Unknown and unclaimed dead bodies were used. Wrapping and preservation of human remains using the cling film plastic wrap could be the best operational practices for first responders rather than leaving bodies exposed on the disaster site, when the supplies of the cadaver body bags are inadequate. Thinking out of the box, the conventional way of using cadaver body bags to the cling film plastic wrap forms a new perspective in managing the dead and facilitating the human identification needs. New inventive idea of adopting the cling film plastic wrap as means of protecting the dignity of the dead person, could be the way forward in humanitarian forensic action.
    Matched MeSH terms: Cadaver
  15. Khoo LS, Lai PS, Saidin MH, Noor Z, Mahmood MS
    Forensic Sci Int, 2018 Apr;285:50-57.
    PMID: 29433011 DOI: 10.1016/j.forsciint.2018.01.018
    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later.
    Matched MeSH terms: Cadaver*
  16. Yang Harmony TC, Yusof N, Ramalingam S, Baharin R, Syahrom A, Mansor A
    Clin Orthop Relat Res, 2022 Feb 01;480(2):407-418.
    PMID: 34491235 DOI: 10.1097/CORR.0000000000001968
    BACKGROUND: Gamma irradiation, which minimizes the risk of infectious disease transmission when human bone allograft is used, has been found to negatively affect its biomechanical properties. However, in those studies, the deep-freezing temperature during irradiation was not necessarily maintained during transportation and sterilization, which may have affected the findings. Prior reports have also suggested that controlled deep freezing may mitigate the detrimental effects of irradiation on the mechanical properties of bone allograft.

    QUESTION/PURPOSE: Does a controlled deep-freezing temperature during irradiation help preserve the compressive mechanical properties of human femoral cortical bone allografts?

    METHODS: Cortical bone cube samples, each measuring 64 mm3, were cut from the mid-diaphyseal midshaft of five fresh-frozen cadaver femurs (four male donors, mean [range] age at procurement 42 years [42 to 43]) and were allocated via block randomization into one of three experimental groups (with equal numbers of samples from each donor allocated into each group). Each experimental group consisted of 20 bone cube samples. Samples irradiated in dry ice were subjected to irradiation doses ranging from 26.7 kGy to 27.1 kGy (mean 26.9 kGy) at a deep-freezing temperature below -40°C (the recommended long-term storage temperature for allografts). Samples irradiated in gel ice underwent irradiation doses ranging from 26.2 kGy and 26.4 kGy (mean 26.3 kGy) in a freezing temperature range between -40°C and 0°C. Acting as controls, samples in a third group were not subjected to gamma irradiation. The mechanical properties (0.2% offset yield stress, ultimate compression stress, toughness, and the Young modulus) of samples from each group were subsequently evaluated via axial compression loading to failure along the long axis of the bone. The investigators were blinded to sample group during compression testing.

    RESULTS: The mean ultimate compression stress (84 ± 27 MPa versus 119 ± 31 MPa, mean difference 35 [95% CI 9 to 60]; p = 0.005) and toughness (3622 ± 1720 kJ/m3 versus 5854 ± 2900 kJ/m3, mean difference 2232 [95% CI 70 to 4394]; p = 0.009) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than in those irradiated at deep-freezing temperatures (below -40°C). The mean 0.2% offset yield stress (73 ± 28 MPa versus 109 ± 38 MPa, mean difference 36 [95% CI 11 to 60]; p = 0.002) and ultimate compression stress (84 ± 27 MPa versus 128 ± 40 MPa, mean difference 44 [95% CI 17 to 69]; p < 0.001) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than the nonirradiated control group samples. The mean 0.2% offset yield stress (73 ± 28 MPa versus 101 ± 28 MPa, mean difference 28 [95% CI 3 to 52]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to those irradiated at deep-freezing temperature. The mean toughness (3622 ± 1720 kJ/m3 versus 6231 ± 3410 kJ/m3, mean difference 2609 [95% CI 447 to 4771]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to the non-irradiated control group samples. The mean 0.2% offset yield stress, ultimate compression stress, and toughness of samples irradiated in deep-freezing temperatures (below -40°C) were not different with the numbers available to the non-irradiated control group samples. The Young modulus was not different with the numbers available among the three groups.

    CONCLUSION: In this study, maintenance of a deep-freezing temperature below -40°C, using dry ice as a cooling agent, consistently mitigated the adverse effects of irradiation on the monotonic-compression mechanical properties of human cortical bone tissue. Preserving the mechanical properties of a cortical allograft, when irradiated in a deep-freezing temperature, may have resulted from attenuation of the deleterious, indirect effects of gamma radiation on its collagen architecture in a frozen state. Immobilization of water molecules in this state prevents radiolysis and the subsequent generation of free radicals. This hypothesis was supported by an apparent loss of the protective effect when a range of higher freezing temperatures was used during irradiation.

    CLINICAL RELEVANCE: Deep-freezing temperatures below -40°C during gamma irradiation may be a promising approach to better retain the native mechanical properties of cortical bone allografts. A further study of the effect of deep-freezing during gamma radiation sterilization on sterility and other important biomechanical properties of cortical bone (such as, tensile strength, fracture toughness, and fatigue) is needed to confirm these findings.

    Matched MeSH terms: Cadaver
  17. Mohamed AS, McCulloch TM
    Laryngoscope, 2004 Jun;114(6):1128-9.
    PMID: 15179226
    Matched MeSH terms: Cadaver
  18. Ariffin AF, Yusof N, Mohd S, Rahman SA, Ramalingam S, Mansor A, et al.
    Cell Tissue Bank, 2019 Dec;20(4):527-534.
    PMID: 31456097 DOI: 10.1007/s10561-019-09785-4
    Calcium contents of demineralised human cortical bone determined by titrimetric assay and atomic absorption spectrophotometry technique were verified by comparing to neutron activation analysis which has high recovery of more than 90%. Conversion factors determined from the comparison is necessary to correct the calcium content for each technique. Femurs from cadaveric donors were cut into cortical rings and demineralised in 0.5 M hydrochloric acid for varying immersion times. Initial calcium content in the cortical bone measured by titration was 4.57%, only 21% of the measurement by neutron activation analysis; while measured by atomic absorption spectrophotometer was 13.4%, only 61% of neutron activation analysis. By comparing more readings with the measurements by neutron activation analysis with 93% recovery, a conversion factor of 4.83 was verified and applied for the readings by titration and 1.45 for atomic absorption spectrophotometer in calculating the correct calcium contents. The residual calcium content started to reduce after the cortical bone was demineralised in hydrochloric acid for 8 h and reduced to 13% after 24 h. Using the linear relationship, the residual calcium content could be reduced to less than 8% after immersion in hydrochloric acid for 40 h. Atomic absorption spectrophotometry technique is the method of choice for calcium content determination as it is more reliable compared to titrimetric assay.
    Matched MeSH terms: Cadaver
  19. Nasir Mohd Nizlan, Azfar Rizal Ahmad, Hisham Abdul Rashid, Paisal Hussin, Che Hamzah Fahrudin, Abdullah Arifaizad, et al.
    MyJurnal
    Introduction: Degenerative disorder involving the acromioclavicular
    joint (ACJ) is quite common especially in the elderly.
    One of the surgical modalities of treatment of this disorder is the
    Mumford Procedure. Arthroscopic approach is preferred due to
    its reduced morbidity and faster post-operative recovery. One
    method utilizes the anteromedial and Neviaser portals, which
    allow direct and better visualization of the ACJ from the
    subacromial space. However, the dangers that may arise from
    incision and insertion of instruments through these portals are
    not fully understood. This cadaveric study was carried out to
    investigate the dangers that can arise from utilization of these
    portals and which structures are at risk during this procedure.
    Methods: Arthroscopic Mumford procedures were performed
    on 5 cadaver shoulders by a single surgeon utilizing the
    anteromedial and Neviaser portals. After marking each portals
    with methylene blue, dissection of nearby structures were
    carried out immediately after each procedure was completed.
    Important structures (subclavian artery as well as brachial plexus
    and its branches) were identified and the nearest measurements
    were made from each portal edges to these structures. Results:
    The anteromedial portal was noted to be closest to the
    suprascapular nerve (SSN) at 2.91 cm, while the Neviaser portal
    was noted to be closest also to the SSN at 1.60 cm. The
    suprascapular nerve was the structure most at risk during the
    Mumford procedure. The anteromedial portal was noted to be
    the most risky portal to utilize compared to the Neviaser portal.
    Conclusion: Extra precaution needs to be given to the
    anteromedial portal while performing an arthroscopic distal
    clavicle resection in view of the risk of injuring the
    suprascapular nerve of the affected limb.
    Matched MeSH terms: Cadaver
  20. Myint K
    Med J Malaysia, 1981 Dec;36(4):227-9.
    PMID: 7334958
    Matched MeSH terms: Cadaver
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links