Displaying publications 61 - 80 of 592 in total

Abstract:
Sort:
  1. Raja Nhari RMH, Muhammad Zailani AN, Khairil Mokhtar NF, Hanish I
    PMID: 32027553 DOI: 10.1080/19440049.2020.1717645
    The usage of porcine pepsin or other porcine derivatives in food products is a common practice in European, American and certain Asian countries although it creates issues in religious and personnel health concerns. In this study, porcine pepsin was detected using indirect ELISA that involved the anti-pep80510 polyclonal antibody raised against a specific peptide of porcine pepsin, pep80510. The sensitivity of the assay for standard porcine pepsin was 0.008 µg/g. The immunoassay did not cross-react to other animal rennet and milk proteins except for microbial coagulant from Mucor miehie. The recovery of porcine pepsin in spiked cheese curd within the range of CV < 20% while for porcine pepsin in spiked cheese whey the recovery is also within the range of CV% < 20%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay*
  2. Tay SP, Cheong SK
    Malays J Pathol, 2002 Jun;24(1):45-51.
    PMID: 16329555
    Tissue Factor (TF) is a low molecular weight transmembrane glycoprotein that initiates the clotting protease cascade. It is considered to be the principal regulator of the extrinsic coagulation pathway, hemostasis and thrombosis, as well as inflammation and cellular immune response. An in-house two-step direct sandwich ELISA (enzyme-linked immunosorbent assay) for immunological quantification of plasma TF was successfully developed. The assay employed a monoclonal antibody against human TF (1:400 dilution; 1250 ng/ml) and peroxidase-conjugated anti-TF IgG (1:1000 dilution; 2000 ng/ml) as capture and detecting antibodies respectively, whilst tetramethylbenzidine/H2O2 were utilized as substrates. Titration curves of recombinant TF were linear within 10 to 4000 pg/ml, with a detection limit of 36.31 pg/ml. It demonstrated low intra- (2.50 - 9.23 CV%) and inter-assays (5.65 - 13.57 CV%) variability, as well as satisfactory analytical recovery (91.55 - 103.95%) and good parallelism. The assay developed was intended to be applied for measurement of plasma TF levels in patients with thrombotic disorders.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  3. Yahaya ML, Zakaria ND, Noordin R, Abdul Razak K
    Biotechnol Appl Biochem, 2021 Oct;68(5):1095-1106.
    PMID: 32935878 DOI: 10.1002/bab.2029
    Salmonella and Shigella genera are common pathogens that contaminate foods and beverages. Lateral flow assays (LFA) are commonly used to detect these pathogens. However, most of the developed LFAs are for single detection. Simultaneous detection of pathogens is required to reduce cost and time. In this work, 40 nm gold nanoparticles (AuNPs) were synthesized using the seeding growth method as labeling agent. The AuNPs were characterized and conjugated with mouse anti-Gram negative endotoxin antibody. The nitrocellulose membrane HF135 was immobilized with anti-mouse IgG antibody as a control line and two separate test lines with either anti-Shigella or anti-Salmonella antibody, respectively. Color intensity of test lines was observed for positive samples. A milk sample was used as proof of concept to mimic actual contamination. The limit of detection of the LFA was 3.0 × 106 CFU/mL for multiplex detection of Shigella flexneri and Salmonella Typhi and for both single detections. The result was comparable with the enzyme-linked immunosorbent assay (ELISA) analysis. The produced LFA could differentiate between Shigella flexneri, Shigella boydii, Salmonella Enteritidis, and Salmonella Typhi. The developed LFA was able to identify Shigella flexneri and Salmonella Typhi with good sensitivity in milk samples, thus, beneficial to ensure the safety of food before entering the market.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation
  4. Ch'ng ACW, Hamidon NHB, Konthur Z, Lim TS
    Methods Mol Biol, 2018;1701:301-319.
    PMID: 29116512 DOI: 10.1007/978-1-4939-7447-4_16
    The application of recombinant human antibodies is growing rapidly mainly in the field of diagnostics and therapeutics. To identify antibodies against a specific antigen, panning selection is carried out using different display technologies. Phage display technology remains the preferred platform due to its robustness and efficiency in biopanning experiments. There are both manual and semi-automated panning selections using polystyrene plastic, magnetic beads, and nitrocellulose as the immobilizing solid surface. Magnetic nanoparticles allow for improved antigen binding due to their large surface area. The Kingfisher Flex magnetic particle processing system was originally designed to aid in RNA, DNA, and protein extraction using magnetic beads. However, the system can be programmed for antibody phage display panning. The automation allows for a reduction in human error and improves reproducibility in between selections with the preprogrammed movements. The system requires minimum human intervention to operate; however, human intervention is needed for post-panning steps like phage rescue. In addition, polyclonal and monoclonal ELISA can be performed using the semi-automated platform to evaluate the selected antibody clones. This chapter will summarize the suggested protocol from the panning stage till the monoclonal ELISA evaluation. Other than this, important notes on the possible optimization and troubleshooting are also included at the end of this chapter.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  5. Onilude OM, Mohd Yusoff S, Emikpe BO, Tanko P, Shahrom SM, Effendy M
    J Immunoassay Immunochem, 2017;38(1):82-99.
    PMID: 27494045 DOI: 10.1080/15321819.2016.1220395
    Early and accurate diagnosis of Brucella melitensis is essential for the treatment and control of brucellosis both in animals and humans. The thrust for the development of a rapid diagnostic technique to overcome the limitations of conventional microbiological and serological tests brought about this investigation on the development and application of dot-ELISA for antigen and antibody detection in infected goats. Fifteen apparently healthy Boer aged 2-3 years which tested negative for brucellosis using PCR and ELISA, were grouped into A (10 goats infected intraocularly with 10(7) CFU of B. melitensis) and B (5 goats) as control. Discharges (ocular, nasal, and vaginal) and blood were collected at days 3, 7, 10, 14, weekly until 42 post-infection (pi) for dot-ELISA, PCR, and RBPT. Dot-ELISA detected B. melitensis antigen and antibody in group A at day 3 and 7 pi, respectively with adequate sensitivity and specificity relative to PCR and RBPT. The bacteria shedding detected from discharges at day 3 pi in the nasal and ocular route with dot-ELISA. Group B were consistently negative. Values such as speed, simplicity, field adaptability, high sensitivity, and specificity make dot-ELISA a rapid and adequate technique for diagnosis of brucellosis in B. melitensis infected goats within few hours.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Kumarasamy V, Chua SK, Hassan Z, Wahab AH, Chem YK, Mohamad M, et al.
    Singapore Med J, 2007 Jul;48(7):669-73.
    PMID: 17609831
    INTRODUCTION: The aim of this report is to establish an accurate diagnosis of acute dengue virus infection early, in order to provide timely information for the management of patients and early public health control of dengue outbreak.
    METHODS: 224 serum samples from patients with a clinical diagnosis of acute dengue infection, which were subsequently confirmed by laboratory tests, were used to evaluate the performance of a commercially-available dengue NS1 antigen-capture ELISA kit.
    RESULTS: The dengue NS1 antigen-capture ELISA gave an overall sensitivity rate of 93.3 percent (209/224). The sensitivity rate was significantly higher in acute primary dengue (97.4 percent) than in acute secondary dengue (68.8 percent). In comparison, the virus isolation gave an overall positive isolation rate of 64.7 percent, with a positive rate of 70.8 percent and 28.1 percent, for acute primary dengue and acute secondary dengue, respectively. Molecular detection of dengue RNA by RT-PCR gave an overall positive detection rate of 63.4 percent, with a positive rate of 62.5 percent and 68.8 percent, for acute primary dengue and acute secondary dengue, respectively. Of the 224 acute serum samples from patients with laboratory-confirmed acute dengue infection, dengue IgM was detected in 88 specimens, comprising 68 acute primary dengue specimens and 20 acute secondary dengue specimens. NS1 antigen-capture ELISA kit gave an overall sensitivity rate of 88.6 percent in the presence of anti-dengue IgM and 96.3 percent in the absence of anti-dengue IgM.
    CONCLUSION: Of the 224 acute serum samples, the sample ages of 166 acute serum samples are known. The positive detection rate of dengue NS1 antigen-capture ELISA, on the whole, was higher than the other three established diagnostic test methods for laboratory diagnosis of acute dengue infection.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  7. Lau WH, Leong WS, Ismail Z, Gam LH
    Int J Biol Sci, 2008 Aug 04;4(4):215-22.
    PMID: 18695745
    Kidney stone disease affects 1 - 20% of the general population. At present, the diagnosis of a stone is done using radiography method when noticeable symptoms appeared. We developed a non-invasive quantitative assay for urinary THP, namely ELISA; whereby our previous study and other reports had shown the usefulness of THP as biomarker for kidney stone disease. Since urine is biological fluid that is easily obtainable, this method could be used as a screening assay for kidney stone prior to confirmation with radiography. The ELISA gave assay linearity r(2) > 0.999 within the range of 109 ng/mL to 945 ng/mL THP. Assay precisions were < 4% (C.V.) for repeatability and < 5% (C.V.) for reproducibility. Assay accuracy range from 97.7% to 101.2% at the various THP concentrations tested. Assay specificity and sensitivity were 80% and 86%, respectively. The cut-off points at P < 0.05 were 37.0 and 41.2 mug/mL for male and female, respectively. The assay is cost effective and rapid whereby the cost for assaying each urine sample in duplicate is approximately USD0.35 and within 5 hours, 37 samples can be assayed alongside full range of standards and 3 QC samples in each plate. Furthermore, sample preparation is relatively easy where urine sample was diluted 10 times in TEA buffer. The usability of the ELISA method for diagnosis of kidney stone disease is evaluated with 117 healthy subjects and 58 stone formers.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  8. Cheng HM, Phuah EB
    Immunol Lett, 1989 Oct;22(4):263-6.
    PMID: 2628284
    Normal human sera (NHS), heat-inactivated at 56 degrees C for 30 min, demonstrated positive ELISA reactions for anti-cardiolipin (aCL) antibodies. The heat-induced reactivity in ELISA was inhibitable by the cardiolipin antigen and was abolished by prior IgG depletion of the heated NHS with a protein A preparation. The heat-potentiated aCL also cross-reacted selectively with phosphatidic acid and phosphatidylserine, but not with phosphatidylcholine or phosphatidylethanolamine.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay*
  9. Wongphutorn P, Noordin R, Anuar NS, Worasith C, Kopolrat KY, Homwong C, et al.
    Am J Trop Med Hyg, 2024 Feb 07;110(2):254-262.
    PMID: 38190756 DOI: 10.4269/ajtmh.23-0518
    Strongyloidiasis, caused by Strongyloides stercoralis, is a neglected tropical disease with a global distribution. The infection can be fatal in immunocompromised individuals, and accurate diagnosis leading to timely treatment can save lives. Serodiagnosis is a sensitive method for diagnosis and is recommended for screening high-risk individuals. A point-of-care rapid test will facilitate the screening activities, especially in low-resource settings. This study aims to apply a new IgG4 immunochromatographic test using S. stercoralis recombinant antigen (SsRapid® cassette test) and to compare it with in-house IgG and IgG4 enzyme-linked immunosorbent assays (IgG- and IgG4-ELISAs) using native Strongyloides ratti antigen to investigate the epidemiology of strongyloidiasis in northeast Thailand. A total of 300 people participated, with 136 males and 164 females of a similar mean age. The reference tests were fecal examinations using the formalin-ethyl acetate concentration technique and an agar plate culture technique. The prevalence of S. stercoralis determined by SsRapid (81.7%) was significantly higher than that by fecal examinations (43.3%) or by antibody detection by IgG-ELISA (53.0%) or IgG4-ELISA (44.0%). The diagnostic sensitivities of SsRapid, IgG-ELISA, and IgG4-ELISA were found to be 93.9%, 77.7%, and 63.1%, respectively. The rate of positive tests by the SsRapid was significantly correlated to the levels of Strongyloides-specific IgG4 and IgG antibodies. By all diagnostic methods, male participants had a significantly higher prevalence of strongyloidiasis than females. Age was significantly associated with the concentration of specific serum IgG but not with the SsRapid grading score. In conclusion, SsRapid was shown to be a sensitive and valuable diagnostic test for the epidemiology study of strongyloidiasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  10. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  11. Ahmed IM, Khairani-Bejo S, Hassan L, Bahaman AR, Omar AR
    BMC Vet Res, 2015;11:275.
    PMID: 26530141 DOI: 10.1186/s12917-015-0587-2
    Brucella melitensis is the most important pathogenic species of Brucella spp. which affects goats and sheep and causes caprine and ovine brucellosis, respectively. Serological tests for diagnosis of brucellosis such as Rose Bengal plate test (RBPT) and enzyme-linked immunosorbent assay (ELISA) usually utilize smooth lipopolysaccharides (S-LPS) as a diagnostic antigen which could give false positive serological reactions. Outer membrane proteins (OMP) of B. melitensis have been used as alternative diagnostic antigens rather than S-LPS for differential serological diagnosis of brucellosis, mainly in ELISA with single recombinant OMP (rOMP) as a diagnostic antigen. Nevertheless, the use of single format mainly showed lack of sensitivity against the desired rOMP. Therefore, this study aimed to determine whether a newly developed rOMPs indirect ELISA (rOMPs I-ELISA), based on combination of rOMP25, rOMP28 and rOMP31of B. melitensis, has a potential benefit for use in the serodiagnosis of brucellosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/veterinary*
  12. Che-Amat A, Risalde MÁ, González-Barrio D, Ortíz JA, Gortázar C
    BMC Vet Res, 2016 Sep 05;12(1):184.
    PMID: 27596591 DOI: 10.1186/s12917-016-0825-2
    Diagnosing tuberculosis (TB) in farmed red deer (Cervus elaphus) is challenging and might require combining cellular and humoral diagnostic tests. Repeated skin-testing with mycobacterial purified protein derivatives (PPDs) might sensitize or desensitize the subjects to both kinds of diagnostic tools. We evaluated the effect of repeated (every 6 months) comparative tuberculin skin testing on skin test and ELISA responsiveness in farmed red deer hinds from a TB-free herd. Eighteen 8-month old hinds were inoculated with bovine and avian PPDs and the mitogen phytohaemagglutinin (PHA), as positive control and concurrently tested by ELISA for antibodies against avian (avian PPD, aPPD and protoplasmatic antigen 3, PPA3) and bovine antigens (bPPD and MPB70). Blood serum was also sampled three weeks after each skin testing round and tested for antibodies against aPPD and bPPD, in order to detect eventual antibody level boosts. Testing took place every six months from winter 2012 until winter 2015.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/veterinary
  13. Mirzadeh A, Saadatnia G, Golkar M, Babaie J, Noordin R
    Protein Expr Purif, 2017 05;133:66-74.
    PMID: 28263855 DOI: 10.1016/j.pep.2017.03.001
    SAG1-related sequence 3 (SRS3) is one of the major Toxoplasma gondii tachyzoite surface antigens and has been shown to be potentially useful for the detection of toxoplasmosis. This protein is highly conformational due to the presence of six disulfide bonds. To achieve solubility and antigenicity, SRS3 depends on proper disulfide bond formation. The aim of this study was to over-express the SRS3 protein with correct folding for use in serodiagnosis of the disease. To achieve this, a truncated SRS3 fusion protein (rtSRS3) was produced, containing six histidyl residues at both terminals and purified by immobilized metal affinity chromatography. The refolding process was performed through three methods, namely dialysis in the presence of chemical additives along with reduced/oxidized glutathione and drop-wise dilution methods with reduced/oxidized glutathione or reduced DTT/oxidized glutathione. Ellman's assay and ELISA showed that the protein folding obtained by the dialysis method was the most favorable, probably due to the correct folding. Subsequently, serum samples from individuals with chronic infection (n = 76), probable acute infection (n = 14), and healthy controls (n = 81) were used to determine the usefulness of the refolded rtSRS3 for Toxoplasma serodiagnosis. The results of the developed IgG-ELISA showed a diagnostic specificity of 91% and a sensitivity of 82.89% and 100% for chronic and acute serum samples, respectively. In conclusion, correctly folded rtSRS3 has the potential to be used as a soluble antigen for the detection of human toxoplasmosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  14. Lim PY, Cardosa MJ
    J Virol Methods, 2019 08;270:113-119.
    PMID: 31100287 DOI: 10.1016/j.jviromet.2019.05.005
    The goal of this paper was to develop a sandwich ELISA that can detect intact human enterovirus A71 (EV-A71) virus-like particles (VLPs) in vaccines. This assay specifically detected EV-A71 viruses from different sub-genogroups as well as EV-A71 VLPs, and treatment of VLPs with high heat and low pH reduced or completely abolished detection of the VLPs suggesting that the ELISA detected assembled particles. Using a purified VLP as a reference standard, a quantitative sandwich ELISA (Q-ELISA) was established which was used to monitor the yield and purity of the VLPs during manufacturing. Coupled with immunogenicity studies, the Q-ELISA was used to evaluate the performance of the VLPs and formalin-inactivated EV-A71 vaccine. This assay has the potential to play an important role in the development of an efficient process to produce and purify the VLPs and in examining the quality of EV-A71 vaccines.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  15. Tamin A, Rota PA
    Dev Biol (Basel), 2013;135:139-45.
    PMID: 23689891 DOI: 10.1159/000189236
    Hendra virus (HeV) and Nipah virus (NiV) are the causative agents of emerging transboundary animal disease in pigs and horses. They also cause fatal disease in humans. NiV has a case fatality rate of 40 - 100%. In the initial NiV outbreak in Malaysia in 1999, about 1.1 million pigs had to be culled. The economic impact was estimated to be approximately US$450 million. Worldwide, HeV has caused more than 60 deaths in horses with 7 human cases and 4 deaths. Since the initial outbreak, HeV spillovers from Pteropus bats to horses and humans continue. This article presents a brief review on the currently available diagnostic methods for henipavirus infections, including advances achieved since the initial outbreak, and a gap analysis of areas needing improvement.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods; Enzyme-Linked Immunosorbent Assay/veterinary
  16. Suriya R, Hassan L, Omar AR, Aini I, Tan CG, Lim YS, et al.
    Zoonoses Public Health, 2008 Sep;55(7):342-51.
    PMID: 18667027 DOI: 10.1111/j.1863-2378.2008.01138.x
    Following a series of H5N1 cases in chickens and birds in a few states in Malaysia, there was much interest in the influenza A viruses subtypes that circulate among the local pig populations. Pigs may act as a mixing vessel for avian and mammal influenza viruses, resulting in new reassorted viruses. This study investigated the presence of antibodies against influenza H1N1 and H3N2 viruses in pigs from Peninsular Malaysia using Herdcheck Swine Influenza H1N1 and H3N2 Antibody Test Kits. At the same time, the presence of influenza virus was examined from the nasal swabs of seropositive pigs by virus isolation and real time RT-PCR. The list of pig farms was obtained from the headquarters of the Department of Veterinary Services, Malaysia, and pig herds were selected randomly from six of 11 states in Peninsular Malaysia. A total of 727 serum and nasal swab samples were collected from 4- to 6-month-old pigs between May and August 2005. By ELISA, the seroprevalences of swine influenza H1N1 and H3N2 among pigs were 12.2% and 12.1% respectively. Seropositivity for either of the virus subtypes was detected in less than half of the 41 sampled farms (41.4%). Combination of both subtypes was detected in 4% of all pigs and in 22% of sampled farms. However, no virus or viral nucleic acid was detected from nasal samples. This study identified that the seropositivity of pigs to H1N1 and H3N2 based on ELISA was significantly associated with factors such as size of farm, importation or purchase of pigs, proximity of farm to other pig farms and the presence of mammalian pets within the farm.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods; Enzyme-Linked Immunosorbent Assay/veterinary
  17. Lokanathan Y, Mohd-Adnan A, Kua BC, Nathan S
    J Fish Dis, 2016 Sep;39(9):1069-83.
    PMID: 27086498 DOI: 10.1111/jfd.12474
    Cryptocaryonosis is a major problem for mariculture, and the absence of suitable sero-surveillance tools for the detection of cryptocaryonosis makes it difficult to screen Cryptocaryon irritans-infected fish, particularly asymptomatic fish. In this study, we proposed a serum-based assay using selected C. irritans proteins to screen infected and asymptomatic fish. Eight highly expressed genes were chosen from an earlier study on C. irritans expressed sequence tags and ciliate glutamine codons were converted to universal glutamine codons. The chemically synthesized C. irritans genes were then expressed in an Escherichia coli expression host under optimized conditions. Five C. irritans proteins were successfully expressed in E. coli and purified by affinity chromatography. These proteins were used as antigens in an enzyme-linked immunosorbent assay (ELISA) to screen sera from experimentally immunized fish and naturally infected fish. Sera from both categories of fish reacted equally well with the expressed C. irritans recombinant proteins as well as with sonicated theronts. This study demonstrated the utility of producing ciliate recombinant proteins in a heterologous expression host. An ELISA was successfully developed to diagnose infected and asymptomatic fish using the recombinant proteins as antigens.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods; Enzyme-Linked Immunosorbent Assay/veterinary*
  18. Kashiwazaki Y, Na YN, Tanimura N, Imada T
    J Virol Methods, 2004 Nov;121(2):259-61.
    PMID: 15381364
    A monoclonal antibody (MAb) based solid-phase blocking ELISA was developed for detection of antibodies to Nipah virus. The ELISA was designed to detect remaining antigens on the plate with anti-Nipah MAb conjugate after the reaction with sample serum, and enabled simple procedure, detection of neutralizing antibody to Nipah virus, and application of samples from different animal species. Forty of 200 swine reference sera examined were positive by the ELISA, of which thirty seven were found positive by serum neutralization test. Sera from a total of 131 fruit bats captured in Malaysia were also tested and all found negative by the both tests. It is considered that the solid-phase blocking ELISA can be used as a screening test for Nipah virus infection followed by the serum neutralization test as confirmatory test.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*; Enzyme-Linked Immunosorbent Assay/standards
  19. Parkash O, Yean CY, Shueb RH
    Diagnostics (Basel), 2014;4(4):165-80.
    PMID: 26852684 DOI: 10.3390/diagnostics4040165
    An electrochemical immunosensor modified with the streptavidin/biotin system on screen printed carbon electrodes (SPCEs) for the detection of the dengue NS1 antigen was developed in this study. Monoclonal anti-NS1 capture antibody was immobilized on streptavidin-modified SPCEs to increase the sensitivity of the assay. Subsequently, a direct sandwich enzyme linked immunosorbent assay (ELISA) format was developed and optimized. An anti-NS1 detection antibody conjugated with horseradish peroxidase enzyme (HRP) and 3,3,5,5'-tetramethybezidine dihydrochloride (TMB/H₂O₂) was used as an enzyme mediator. Electrochemical detection was conducted using the chronoamperometric technique, and electrochemical responses were generated at -200 mV reduction potential. The calibration curve of the immunosensor showed a linear response between 0.5 µg/mL and 2 µg/mL and a detection limit of 0.03 µg/mL. Incorporation of a streptavidin/biotin system resulted in a well-oriented antibody immobilization of the capture antibody and consequently enhanced the sensitivity of the assay. In conclusion, this immunosensor is a promising technology for the rapid and convenient detection of acute dengue infection in real serum samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  20. Emelia O, Zeehaida M, Sulaiman O, Rohela M, Saadatnia G, Yeng C, et al.
    J Immunoassay Immunochem, 2010;31(1):79-91.
    PMID: 20391020 DOI: 10.1080/15321810903405134
    We have developed an ELISA that employs monoclonal anti-Toxoplasma SAG1 (p30) as the capture antibody to detect T. gondii circulating antigens in patients' serum samples. Using serum spiked with Toxoplasma soluble and with SAG1 recombinant proteins, the detection limits were 31.25 ng/mL and 62.50 ng/mL, respectively. We obtained positive results in 28% (21/75) and 11% (23/206) of probable active and chronic toxoplasmosis serum samples, respectively. Western blot analysis on pooled antigen-positive serum samples showed antigenic bands of molecular weights 25 and 75 kDa from sera of probable active infection and five antigenic bands ranging in size from 26 to 33 kDa from chronic infection sera. This assay would be useful as an initial serum selection step in developing a Toxoplasma antigen detection test and for characterization studies.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links