Case presentation: We present a case of 15-year-old boy from rural area, presented with chronic diarrhea and per rectal bleeding for 3 months. The diagnosis was determined by colonoscope which revealed a fungating mass identified at 10cm from anal verge. Histological examination confirmed diagnosis of signet ring cell adenocarcinoma. CT scan of the abdomen showed thickening involving the recto-sigmoid colon and rectal mass, without evidence of distant metastatic disease. The patient's carcinoembryonic antigen level was within the normal range. He underwent a colostomy and was subjected to neoadjuvant CCRT and surgery.
Discussion: This CASE highlights the importance and challenges in achieving early diagnosis and surgical intervention of signet-ring cell carcinoma in adolescents, as most cases are detected at an advanced stage coupled with the scarcity of information on these rarer subtypes which leads to a poor prognosis.
Conclusion: In managing Signet cell carcinoma of the colorectal, physician have to know that it has a poor prognosis in patients of any age. However, in young teenagers delayed diagnosis and treatment option are narrowed to palliative management. Genetic profiling of family members and similar environment population may be a key to early detection.
METHODS: Computed tomography scans from 74 patients were retrospectively evaluated between January 2008 and December 2012. Pedicle perforations were classified by two types of grading systems. For medial, lateral, superior and inferior perforations: grade 0 - no violation; grade 1 - <2 mm; grade 2 - 2-4 mm and grade 3 - >4 mm. For anterior perforations: grade 0 - no violation; grade 1 - <4 mm; grade 2 - 4-6 mm and grade 3 - >6 mm.
RESULTS: There were 35 (47.3%) male and 39 (52.7%) female patients with a total 260 thoracic pedicle screws (T1-T6) analysed. There were 32 screw perforations which account to a perforation rate of 12.3% (11.2% grade 1, 0.7% grade 2 and 0.4% grade 3). None led to pedicle screw-related complications. The perforation rate was highest at T1 (33.3%, all grade 1 perforations), followed by T6 (14.5%) and T4 (14.0%).
CONCLUSION: Fluoroscopic guided percutaneous pedicle screws of the upper thoracic spine (T1-T6) are technically more demanding and carry potential risks of serious complications. Extra precautions need to be taken when fluoroscopic guided percutaneous pedicle screws are placed at T1 and T2 levels, due to high medial pedicular angulation and obstruction of lateral fluoroscopic images by the shoulder girdle and at T4-T6 levels, due to smaller pedicular width.
PURPOSE: To evaluate the feasibility of percutaneous posterolateral fusion in the spine utilizing rhBMP-2.
STUDY DESIGN: Animal study.
METHODS: This is an animal research model involving 32 New Zealand white rabbits stratified into 4 study groups: control, autogenous iliac crest bone graft (ICBG), demineralized bone matrix (DBM), and rhBMP-2 groups, with 8 study subjects per group. The rhBMP-2 group was subdivided into the open technique (right side) and the percutaneous technique groups (left side). Fusion was graded at 6 weeks and 3 months after plain radiography, computed tomography, and clinical assessment with the following grading system: grade A, no bone formation; grade B, non-bridging bone formation; grade C, fusion; and grade D, fusion with ectopic bone formation.
RESULTS: No fusion was noted in the placebo and the DBM groups. However, in the DBM group, bone formation occurred in 37.5% of the subjects. The rhBMP-2 group had a higher fusion rate compared with the ICBG group at 6 weeks and 3 months. The fusion rate for the ICBG, the rhBMP-2 (open), and the rhBMP-2 (percutaneous) groups were 37.5%, 87.5%, and 50.0% at 6 weeks and 50.0%, 100.0%, and 62.5% at 3 months, respectively. Ectopic bone formation occurred in 12.5% of the cases in the rhBMP-2 (percutaneous) group and in 25.0% of the cases in the rhBMP-2 (open) group.
CONCLUSIONS: Usage of rhBMP-2 is feasible for percutaneous posterolateral fusion of the lumbar spine in this animal model. However, a more precise delivery system might improve the fusion rate when the percutaneous technique is used. A significant rate of ectopic bone formation occurred when rhBMP-2 was used.
METHODS AND STUDY DESIGN: A randomized controlled study was conducted on obese women with high breast adiposity (<0.1 Sm-1), aged 40-60 years in Klang Valley, Malaysia. Subjects were assigned to intervention (n=16) and control group (n=15). Intervention group received a home based health education package with close monitoring weekly, personal diet consultation and physical training in group. Assessment was ascertained at three time points; baseline, weeks 8 and 16. Outcome measures were the energy intake, physical activity, body composition, blood tests, blood biomarkers and electrical impedance tomography (EIT) quantitative values. Analyses were done using 2-way repeated measures ANOVA.
RESULTS AND CONCLUSIONS: All subjects completed the program without any drop-out. The HSI group had 100% compliance towards the intervention program; their energy intake was reduced for approximately 35% and their activity score was increased for approximately 11%. A significant interaction effect was found in body weight, body mass index (BMI), total cholesterol/HDL, vitamin C intake and matrix metallopeptidase 9 (MMP-9) (p<0.05). Interestingly, their EIT extremum values were also significantly increased indicating a reduction of breast adiposity. The intervention program was successful in improving body composition, physical activities, MMP9 and breast adipose tissue composition.
CASE PRESENTATION: A 25 years old female had neglected an extremely large midline sacral mass for 2 years. On presentation to hospital, she had been bed bound for the past 2 years. The sacral mass was so large that it prevented her from lying down supine and sitting on the wheelchair comfortably. Clinical examination showed a 40 cm × 30 cm × 20 cm hard mass over the sacrum that involved both buttocks and the gluteal fold. Neurological exam of bilateral lower limb was normal. Computed Tomography Scan of the Pelvis showed a large destructive sacrococcygeal mass measuring 43 cm × 38 cm × 27 cm with extension into the presacral space resulting in anterior displacement of the rectum, urinary bladder and uterus; and posterior extension into the dorsal soft tissue with involvement of the gluteus, piriformis, and left erector spinae muscles. Biopsy taken confirmed Chordoma. This patient was managed by a multidisciplinary team in an Oncology referral centre. The patient had undergone Wide En Bloc Resection and Sacrectomy, a complex surgery that was associated with complications namely bleeding, surgical site infection and neurogenic bowel and bladder. Six months post operatively the patient was able to lie supine and sit on wheelchair comfortably. She required extensive rehabilitation to help her ambulate in future.
CONCLUSION: This is a rare case of neglected sacral chordoma in a young female treated with Wide En Bloc Resection and Sacrectomy associated with complications of this complex surgery. Nevertheless, surgery is still worthwhile to improve the quality of life and to prevent complications secondary to prolonged immobilization. A multidisciplinary approach is ideal and team members need to be prepared to address the complications once they arise.
STUDY DESIGN: Experimental.
SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.
METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.
RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded = .003; Ploaded
METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.
RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).
CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.
METHODS: All surgeries were performed by minimally invasive technique with either percutaneous monoaxial or percutaneous polyaxial screws inserted at adjacent fracture levels perpendicular to both superior end plates. Fracture reduction is achieved with adequate rod contouring and distraction maneuver. Radiological parameters were measured during preoperation, postoperation, and follow-up.
RESULTS: A total of 21 patients were included. Eleven patients were performed with monoaxial pedicle screws and 10 patients performed with polyaxial pedicle screws. Based on AO thoracolumbar classification system, 10 patients in the monoaxial group had A3 fracture type and 1 had A4. In the polyaxial group, six patients had A3 and four patients had A4. Total correction of anterior vertebral height (AVH) ratio was 0.30 ± 0.10 and 0.08 ± 0.07 in monoaxial and polyaxial groups, respectively (p < 0.001). Total correction of posterior vertebral height (PVH) ratio was 0.11 ± 0.05 and 0.02 ± 0.02 in monoaxial and polyaxial groups, respectively (p < 0.001). Monoaxial group achieved more correction of 13° (62.6%) in local kyphotic angle compared to 8.2° (48.0%) in polyaxial group. Similarly, in regional kyphotic angle, 16.5° (103.1%) in the monoaxial group and 8.1° (76.4%) in the polyaxial group were achieved.
CONCLUSIONS: Monoaxial percutaneous pedicle screws inserted at adjacent fracture levels provided significantly better fracture reduction compared to polyaxial screws in thoracolumbar fractures.