Displaying publications 121 - 140 of 592 in total

Abstract:
Sort:
  1. Hajissa K, Zakaria R, Suppian R, Mohamed Z
    Parasit Vectors, 2015;8:315.
    PMID: 26062975 DOI: 10.1186/s13071-015-0932-0
    Serological investigation remains the primary approach to achieve satisfactory results in Toxoplasma gondii identification. However, the accuracy of the native antigen used in the current diagnostic kits has proven to be insufficient as well as difficult to standardize, so significant efforts have been made to find alternative reagents as capture antigens. Consequently, multi-epitope peptides are promising diagnostic markers, with the potential for improving the accuracy of diagnostic kits. In this study, we described a simple, inexpensive and improved strategy to acquire such diagnostic markers. The study was aimed at producing novel synthetic protein consisting of multiple immunodominant epitopes of several T. gondii antigens.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  2. Chenthamarakshan V, Vadivelu J, Puthucheary SD
    Diagn Microbiol Infect Dis, 2001 Jan;39(1):1-7.
    PMID: 11173184
    IgM and IgG based ELISA systems were developed using the culture filtrate antigen (CFA) of Burkholderia pseudomallei. The assays were evaluated using 95 sera from 66 septicemic cases and 47 sera from 20 cases with localized melioidosis. In addition 65 sera from culture negative cases that were also serologically negative for other endemic infections clinically suspected of melioidosis were included. These were compared with sera from 260 non-melioidosis cases, 169 sera from individuals with high risk of acquiring the infection and 48 sera from healthy controls. The IgG-ELISA was 96% sensitive and 94% specific. All sera from cases with septicemic and localized infections and 61 of 63 sera from clinically suspected melioidosis cases were positive for IgG antibody. The geometric mean titre index (GMTI) values of IgG antibody in melioidosis cases were significantly higher (p < 0.0005) compared to that of healthy subjects, high risk group and subjects with non-melioidosis infections. The sensitivity and specificity of IgM ELISA was 74 and 99% respectively. The GMTI value of IgM antibody in the sera of melioidosis cases was significantly higher as compared to that of non-melioidosis disease controls (p < or = 0.001). These results demonstrate that the detection of IgG is a better indicator of the disease in the diagnosis of melioidosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  3. Cheah TS, Sani RA, Chandrawathani P, Bahri S, Dahlan I
    Trop Anim Health Prod, 1999 Feb;31(1):25-31.
    PMID: 10399814
    An investigation into the epidemiology of Trypansoma evansi infection in crossbred dairy cattle was conducted for a period of 12 months on a dairy cattle farm in Penninsular Malaysia. The prevalence of parasitaemia was highest in lactating animals (13.4%), followed by those in the dry herd (8.8%), late pregnant animals (8.1%), early pregnant animals (4.7%), calves (0.3%) and heifers (0.2%). The prevalence of antigenaemia was highest in the lactating animals (54.7%), followed by that in dry animals (53.7%), heifers (51.1%), late pregnant animals (47.7%), early pregnant animals (46.5%) and calves (24.2%).
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/veterinary
  4. Ambu S, Rain AN, Mak JW, Maslah D, Maidah S
    PMID: 9656366
    Three MAbs 1C4.2D8, 1C4.2C4 and 1C4.1F5 were produced using sonicated adult worm antigens of Angiostrongylus malaysiensis and they were found to be secreters of IgG1. The MAbs 1C4.2C4 and 1C4.2D8 were found to react with antigens of A. malaysiensis and cross-react with the closely related A. cantonensis but not with other helminths. A total of 108 human sera collected from Orang Asli (aborigenes) from Grik, in the State of Perak were tested for A. malaysiensis infection using the MAb-ELISA. MAb 1C4.1F5 and 25 (23%) were positive. Twenty of these positive samples were tested with the MAb 1C4.2D8 and none was found to be positive.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  5. Rahmah N, Anuar AK, Karim R, Mehdi R, Sinniah B, Omar AW
    Biochem Biophys Res Commun, 1994 Nov 30;205(1):202-7.
    PMID: 7999024
    Sera from fifty subjects with different presentations of Brugian filariasis and from common soil-transmitted helminth infections were tested for specific anti-filarial IgG and its subclasses. Anti-filarial IgG, IgG1 and IgG3 showed cross-reactivities with soil-transmitted helminthic infections and no significant differences in optical densities among the various groups of filarial patients. In comparison with other groups of subjects, IgG4-ELISA of sera from microfilaraemic patients and some previously microfilaraemic patients showed a significant increase in optical density readings, while IgG2-ELISA showed elevated optical density readings in sera of patients with chronic elephantiasis. Therefore IgG2-ELISA is potentially useful in the diagnosis of brugian chronic elephantiasis while IgG4-ELISA may be beneficial for follow-up diagnosis of treated microfilaraemic patients.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  7. Shah-Majid M
    Trop Anim Health Prod, 1996 May;28(2):181-2.
    PMID: 8809982
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  8. Razak CN, Salam F, Ampon K, Basri M, Salleh AB
    Ann N Y Acad Sci, 1998 Dec 13;864:479-84.
    PMID: 9928128
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  9. Chandrasekaran S, Kennett L, Yeap PC, Muniandy N, Rani B, Mukkur TK
    Vet Microbiol, 1994 Aug 15;41(4):303-9.
    PMID: 7801530
    The relationship between the standard passive mouse protection test or serum antibody titres measured by indirect haemagglutination or enzyme-linked immunosorbent assays and active protection in buffaloes immunized with different types of haemorrhagic septicaemia bacterins was investigated. Groups of 2-3 buffaloes were immunized with the bacterins currently in use in Asia, viz., broth bacterin (BB), alum precipitated vaccine (APV) and oil adjuvant vaccine (OAV) either subcutaneously (BB, APV) or intramuscularly (OAV) and challenged subcutaneously with virulent organisms at different periods post-immunization. Although the passive mouse protection and indirect haemagglutination tests carried out with the pre-challenge sera from vaccinated buffaloes revealed no relationship with active protection in buffaloes, a relationship was observed between the ELISA antibody titres and protection. In contrast, a dose-response relationship was observed between the homologous active and passive mouse protection test.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/veterinary
  10. Mahnke C, Kashaiya P, Rössler J, Bannert H, Levin A, Blattner WA, et al.
    Arch Virol, 1992;123(3-4):243-53.
    PMID: 1314048
    Serum samples collected from patients with a wide variety of diseases from African and other countries were tested for antibodies to the human spumaretrovirus (HSRV). A spumaviral env-specific ELISA was employed as screening test. Out of 3020 human sera screened, 106 were found to be positive (3.2%). While the majority of patients' sera from Europe (1581) were negative, 26 were positive (1.6%). Sera from healthy adult blood donors (609), from patients with multiple sclerosis (48), Graves' disease (45), and chronic fatigue syndrome (41) were negative or showed a very low prevalence for spumaviral env antibodies. A higher percentage of seropositives (6.3%) were found among 1338 African patients from Tanzania, Kenya, and Gabon. Out of 1180 patients from Tanzania, 708 suffered from tumors, 75 from AIDS, and 128 had gynecological problems; 51 of the Tanzanian patients were HSRV seropositive (4.3%). A particularly high percentage of 16.6% seropositives were identified among nasopharyngeal carcinoma patients (NPC) from Kenya and Tanzania consistent with results reported 10 years ago. However, 20 nasopharyngeal carcinoma patients from Malaysia were HSRV-seronegative. In selected cases, sera from seropositive individuals were reacted with proteins from HSRV-infected cells in vitro. HSRV env- and gag-specific antibodies were specifically detected by these sera in Western blots. The results indicate spumavirus infections in human patients with various diseases at a relatively low prevalence worldwide; in African patients, however, the prevalence of spumavirus infections is markedly higher.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  11. Cardosa MJ, Choo BH, Zuraini I
    PMID: 1667957
    This study describes the status of viral encephalitis in Perak, Malaysia during the year 1990. In addition, 14 cases selected from Penang and Perak during the years 1989 and 1990 are presented, with data showing titers of neutralizing antibodies against Japanese encephalitis virus (JEV) and dengue 2 virus, titers of antibodies against JEV and dengue virus antigens as determined by DEIA, and a comparison of these with the presence of IgM to JEV and dengue virus. These data show that there probably is far more viral encephalitis due to JEV in Malaysia than the national figures reflect.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/standards
  12. Rahumatullah A, Lim TS, Yunus MH, Noordin R
    Am J Trop Med Hyg, 2019 08;101(2):436-440.
    PMID: 31162018 DOI: 10.4269/ajtmh.19-0034
    Lymphatic filariasis is a mosquito-borne parasitic disease responsible for morbidity and disability that affects 1.2 billion people worldwide, mainly the poor communities. Currently, filarial antigen testing is the method of choice for the detection of bancroftian filariasis, and to date, there are two commonly used tests. In the present study, a recently reported recombinant monoclonal antibody (5B) specific to BmSXP filarial antigen was used in developing an ELISA for the detection of circulating filarial antigen in sera of patients with bancroftian filariasis. The performance of the ELISA was evaluated using 124 serum samples. The ELISA was positive with all sera from microfilaremic bancroftian filariasis patients (n = 34). It also showed 100% diagnostic specificity when tested with sera from 50 healthy individuals and 40 patients with other parasitic diseases. The developed assay using the novel 5B recombinant monoclonal antibody could potentially be a promising alternative antigen detection test for bancroftian filariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  13. Kuo IC, Cheong N, Trakultivakorn M, Lee BW, Chua KY
    J Allergy Clin Immunol, 2003 Mar;111(3):603-9.
    PMID: 12642844
    BACKGROUND: Dual sensitization by Blomia tropicalis and Dermatophagoides pteronyssinus mites is common in tropical and subtropical countries. The human IgE cross-reactivity between clinical important group 5 allergens, Blo t 5 and Der p 5, remains controversial.

    OBJECTIVE: This study was undertaken to assess the levels of the IgE cross-reactivity between Blo t 5 and Der p 5 by using sera from a large cohort of asthmatic children in subtropical and tropical countries.

    METHODS: Purified recombinant Blo t 5 and Der p 5 were produced in Pichia pastoris and tested against sera from 195 asthmatic children. The IgE cross-reactivity was examined by direct, inhibitory and competitive human IgE enzyme-linked immunosorbent assay as well as skin prick tests.

    RESULTS: The Blo t 5 IgE responses were 91.8% (134 of 146) and 73.5% (36 of 49) for Taiwanese and Malaysian sera, respectively. The Blo t 5 specific IgE titers were significantly higher than those of Der p 5 (P

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  14. Hasmoni SS, Yusoff K, Tan WS
    J Gen Appl Microbiol, 2005 Apr;51(2):125-31.
    PMID: 15942873
    The nucleocapsids of hepatitis B virus (HBV) are made of 180 or 240 subunits of core proteins or known as core antigens (HBcAg). A fusion bacteriophage bearing the WSFFSNI sequence that interacts tightly to HBcAg was employed as a diagnostic reagent for the detection of the antigen using the phage-enzyme-linked immunosorbent (phage-ELISA), dot blot and immunoprecipitation assays. The results from phage-ELISA and dot blot assay showed that as low as 10 ng of HBcAg can be detected optimally by 1.0x10(12) pfu/ml fusion M13 bacteriophage. The sensitivity of the dot blot assay corresponds with that of the phage-ELISA. HBcAg in HBV positive serum samples can also be detected using the fusion phage via the phage-ELISA and phage-dot blot assay. The phage cross-linked to cyanogen bromide (CNBr) activated agarose can also be used to precipitate HBcAg in bacterial lysate. The optimum amount of phage needed for cross-linking to 1 g of agarose is about 7.0x10(6) pfu/ml which could also precipitate purified and unpurified HBcAg in bacterial lysate. This study demonstrates the potential of fusion bacteriophage bearing the sequence WSFFSNI as a diagnostic reagent and a ligand for the detection and purification of HBcAg respectively.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  15. Rahmah N, Lim BH, Azian H, Ramelah TS, Rohana AR
    Trop Med Int Health, 2003 Feb;8(2):158-63.
    PMID: 12581442
    Brugian filariasis infects 13 million people in Asia. The routine prevalence survey method using night thick blood smear is not sensitive enough to reflect the actual infection prevalence. In 1997-2001, only three microfilaraemic cases (of 5601 individuals screened; 0.05%) were reported in Pasir Mas, a district in Kelantan (Malaysia), which shares a border with Thailand. We therefore investigated the infection prevalence in this district by employing a sensitive and specific serological assay (Brugia-Elisa). This test is based on detection of specific IgG4 antibody against a Brugia malayi recombinant antigen. A total of 5138 children, aged 7-12 years, from 16 primary schools, were tested. Eighteen pupils in eight schools, located in five subdistricts, tested positive, giving an overall prevalence rate of 0.35%. Infection in these children is significant as they represent more recent cases. These subdistricts should be included in the national filariasis elimination programme.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  16. Kit Lam S, Lan Ew C, Mitchell JL, Cuzzubbo AJ, Devine PL
    Clin Diagn Lab Immunol, 2000 Sep;7(5):850-2.
    PMID: 10973469
    A commercially available enzyme-linked immunosorbent assay (ELISA) (PanBio Dengue Screening ELISA) that utilized both immunoglobulin M (IgM) and IgG capture in the same microtiter well for the diagnosis of dengue infection was evaluated. Sensitivity in primary and secondary dengue was 95%, while specificity was 94%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  17. Hawgood BJ
    Toxicon, 1998 Mar;36(3):431-46.
    PMID: 9637363
    Alistair Reid was an outstanding clinician, epidemiologist and scientist. At the Penang General Hospital, Malaya, his careful observation of sea snake poisoning revealed that sea snake venoms were myotoxic in man leading to generalized rhabdomyolysis, and were not neurotoxic as observed in animals. In 1961, Reid founded and became the first Honorary Director of the Penang Institute of Snake and Venom Research. Effective treatment of sea snake poisoning required specific antivenom which was produced at the Commonwealth Serum Laboratories in Melbourne from Enhydrina schistosa venom supplied by the Institute. From the low frequency of envenoming following bites, Reid concluded that snakes on the defensive when biting man seldom injected much venom. He provided clinical guidelines to assess the degree of envenoming, and the correct dose of specific antivenom to be used in the treatment of snake bite in Malaya. Reid demonstrated that the non-clotting blood of patients bitten by the pit viper, Calloselasma rhodostoma [Ancistrodon rhodostoma] was due to venom-induced defibrination. From his clinical experience of these patients, Reid suggested that a defibrinating derivative of C. rhodostoma venom might have a useful role in the treatment of deep vein thrombosis. This led to Arvin (ancrod) being used clinically from 1968. After leaving Malaya in 1964, Alistair Reid joined the staff of the Liverpool School of Tropical Medicine, as Senior Lecturer. Enzyme-linked immunosorbent assay (ELISA) for detecting and quantifying snake venom and venom-antibody was developed at the Liverpool Venom Research Unit: this proved useful in the diagnosis of snake bite, in epidemiological studies of envenoming patterns, and in screening of antivenom potency. In 1977, Dr H. Alistair Reid became Head of the WHO Collaborative Centre for the Control of Antivenoms based at Liverpool.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/history
  18. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  19. Fang TY, Praveena SM, deBurbure C, Aris AZ, Ismail SN, Rasdi I
    Chemosphere, 2016 Dec;165:358-368.
    PMID: 27665296 DOI: 10.1016/j.chemosphere.2016.09.051
    In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  20. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links