Displaying all 4 publications

Abstract:
Sort:
  1. Ismail S, Yusof NA, Abdullah J, Abd Rahman SF
    Materials (Basel), 2020 Jul 16;13(14).
    PMID: 32708531 DOI: 10.3390/ma13143168
    Arsenic poisoning in the environment can cause severe effects on human health, hence detection is crucial. An electrochemical-based portable assessment of arsenic contamination is the ability to identify arsenite (As(III)). To achieve this, a low-cost electroanalytical assay for the detection of As(III) utilizing a silica nanoparticles (SiNPs)-modified screen-printed carbon electrode (SPCE) was developed. The morphological and elemental analysis of functionalized SiNPs and a SiNPs/SPCE-modified sensor was studied using field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), and Fourier transform infrared spectroscopy (FTIR). The electrochemical responses towards arsenic detection were measured using the cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) techniques. Under optimized conditions, the anodic peak current was proportional to the As(III) concentration over a wide linear range of 5 to 30 µg/L, with a detection limit of 6.2 µg/L. The suggested approach was effectively valid for the testing of As(III) found within the real water samples with good reproducibility and stability.
  2. Abd Rahman SF, Md Arshad MK, Gopinath SCB, Fathil MFM, Sarry F, Ibau C
    Chem Commun (Camb), 2021 Sep 23;57(76):9640-9655.
    PMID: 34473143 DOI: 10.1039/d1cc03080a
    Prostate cancer is currently diagnosed using the conventional gold standard methods using prostate-specific antigen (PSA) as the selective biomarker. However, lack of precision in PSA screening has resulted in needless biopsies and delays the treatment of potentially fatal prostate cancer. Thus, identification of glycans as novel biomarkers for the early detection of prostate cancer has attracted considerable attention due to their reliable diagnostic platform compared with the current PSA systems. Therefore, biosensing technologies that provide point-of-care diagnostics have demonstrated the ability to detect various analytes, including glycosylated micro- and macro-molecules, thereby enabling versatile detection methodologies. This highlight article discusses recent advances in the biosensor-based detection of prostate cancer glycan biomarkers and the innovative strategies for the conjugation of nanomaterials adapted to biosensing platforms. Finally, the article is concluded with prospects and challenges of prostate cancer biosensors and recommendations to overcome the issues associated with prostate cancer diagnosis.
  3. Taib AK, Johari Z, Abd Rahman SF, Mohd Yusoff MF, Hamzah A
    PLoS One, 2023;18(3):e0282370.
    PMID: 36897883 DOI: 10.1371/journal.pone.0282370
    In this study, computational simulations were used to investigate the performance of a carbon-doped boron nitride nanoribbon (BC2NNR) for hydrogen (H2) gas sensing at elevated temperatures. The adsorption energy and charge transfer were calculated when H2 was simultaneously attached to carbon, boron, and both boron and nitrogen atoms. The sensing ability was further analyzed considering the variations in current-voltage (I-V) characteristics. The simulation results indicated that the energy bandgap of H2 on carbon, boron, and both boron and nitrogen exhibited a marginal effect during temperature variations. However, significant differences were observed in terms of adsorption energy at a temperature of 500 K, wherein the adsorption energy was increased by 99.62% of that observed at 298 K. Additionally, the evaluation of charge transfer indicated that the strongest binding site was achieved at high adsorption energies with high charge transfers. Analysis of the I-V characteristics verified that the currents were considerably affected, particularly when a certain concentration of H2 molecules was added at the highest sensitivity of 15.02% with a bias voltage of 3 V. The sensitivity at 298 K was lower than those observed at 500 and 1000 K. The study findings can form the basis for further experimental investigations on BC2NNR as a hydrogen sensor.
  4. Mohd Azmi UZ, Yusof NA, Kusnin N, Abdullah J, Suraiya S, Ong PS, et al.
    Sensors (Basel), 2018 Nov 14;18(11).
    PMID: 30441776 DOI: 10.3390/s18113926
    A rapid and sensitive sandwich electrochemical immunosensor was developed based on the fabrication of the graphene/polyaniline (GP/PANI) nanocomposite onto screen-printed gold electrode (SPGE) for detection of tuberculosis biomarker 10-kDa culture filtrate protein (CFP10). The prepared GP/PANI nanocomposite was characterized using Fourier transform infrared spectroscopy (FTIR) and field emission scanning electron microscopy (FESEM). The chemical bonding and morphology of GP/PANI-modified SPGE were studied by Raman spectroscopy and FESEM coupled with energy dispersive X-ray spectroscopy, respectively. From both studies, it clearly showed that GP/PANI was successfully coated onto SPGE through drop cast technique. Cyclic voltammetry was used to study the electrochemical properties of the modified electrode. The effective surface area for GP/PANI-modified SPGE was enhanced about five times compared with bare SPGE. Differential pulse voltammetry was used to detect the CFP10 antigen. The GP/PANI-modified SPGE that was fortified with sandwich type immunosensor exhibited a wide linear range (20⁻100 ng/mL) with a low detection limit of 15 ng/mL. This proposed electrochemical immunosensor is sensitive, low sample volume, rapid and disposable, which is suitable for tuberculosis detection in real samples.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links