  1. Redmond DP, Chiew YS, Major V, Chase JG
    Comput Methods Programs Biomed, 2019 Apr;171:67-79.
    PMID: 27697371 DOI: 10.1016/j.cmpb.2016.09.011
    Monitoring of respiratory mechanics is required for guiding patient-specific mechanical ventilation settings in critical care. Many models of respiratory mechanics perform poorly in the presence of variable patient effort. Typical modelling approaches either attempt to mitigate the effect of the patient effort on the airway pressure waveforms, or attempt to capture the size and shape of the patient effort. This work analyses a range of methods to identify respiratory mechanics in volume controlled ventilation modes when there is patient effort. The models are compared using 4 Datasets, each with a sample of 30 breaths before, and 2-3 minutes after sedation has been administered. The sedation will reduce patient efforts, but the underlying pulmonary mechanical properties are unlikely to change during this short time. Model identified parameters from breathing cycles with patient effort are compared to breathing cycles that do not have patient effort. All models have advantages and disadvantages, so model selection may be specific to the respiratory mechanics application. However, in general, the combined method of iterative interpolative pressure reconstruction, and stacking multiple consecutive breaths together has the best performance over the Dataset. The variability of identified elastance when there is patient effort is the lowest with this method, and there is little systematic offset in identified mechanics when sedation is administered.
  2. Goh MJS, Chiew YS, Foo JJ
    Sci Rep, 2021 03 29;11(1):7063.
    PMID: 33782475 DOI: 10.1038/s41598-021-86418-5
    A net immersed in fractal-induced turbulence exhibit a transient time-varying deformation. The anisotropic, inhomogeneous square fractal grid (SFG) generated flow interacts with the flexible net to manifest as visible cross-sectional undulations. We hypothesize that the net's response may provide a surrogate in expressing local turbulent strength. This is analysed as root-mean-squared velocity fluctuations in the net, displaying intensity patterns dependent on the grid conformation and grid-net separation. The net's fluctuation strength is found to increase closer to the turbulator with higher thickness ratio while presenting stronger fluctuations compared to regular-square-grid (RSG) of equivalent blockage-ratio, σ. Our findings demonstrate a novel application where 3D-reconstruction of submerged nets is used to experimentally contrast the turbulence generated by RSG and multilength scale SFGs across the channel cross-section. The net's response shows the unique turbulence developed from SFGs can induce 9 × higher average excitation to a net when compared against RSG of similar σ.
  3. Langdon R, Docherty PD, Chiew YS, Chase JG
    Math Biosci, 2017 02;284:32-39.
    PMID: 27513728 DOI: 10.1016/j.mbs.2016.08.001
    For patients with acute respiratory distress syndrome (ARDS), mechanical ventilation (MV) is an essential therapy in the intensive care unit (ICU). Suboptimal PEEP levels in MV can cause ventilator induced lung injury, which is associated with increased mortality, extended ICU stay, and high cost. The ability to predict the outcome of respiratory mechanics in response to changes in PEEP would thus provide a critical advantage in personalising and improving care. Testing the potentially dangerous high pressures would not be required to assess their impact. A nonlinear autoregressive (NARX) model was used to predict airway pressure in 19 data sets from 10 mechanically ventilated ARDS patients. Patient-specific NARX models were identified from pressure and flow data over one, two, three, or four adjacent PEEP levels in a recruitment manoeuvre. Extrapolation of NARX model elastance functions allowed prediction of patient responses to PEEP changes to higher or lower pressures. NARX model predictions were more successful than those using a well validated first order model (FOM). The most clinically important results were for extrapolation up one PEEP step of 2cmH2O from the highest PEEP in the training data. When the NARX model was trained on one PEEP level, the mean RMS residual for the extrapolation PEEP level was 0.52 (90% CI: 0.47-0.57) cmH2O, compared to 1.50 (90% CI: 1.38-1.62) cmH2O for the FOM. When trained on four PEEP levels, the NARX result was 0.50 (90% CI: 0.42-0.58) cmH2O, and was 1.95 (90% CI: 1.71-2.19) cmH2O for the FOM. The results suggest that a full recruitment manoeuvre may not be required for the NARX model to obtain a useful estimate of the pressure waveform at higher PEEP levels. The methodology could thus allow clinicians to make informed decisions about ventilator PEEP settings while reducing the risk associated with high PEEP, and subsequent high peak airway pressures.
  4. Major VJ, Chiew YS, Shaw GM, Chase JG
    Biomed Eng Online, 2018 Nov 12;17(1):169.
    PMID: 30419903 DOI: 10.1186/s12938-018-0599-9
    BACKGROUND: Mechanical ventilation is an essential therapy to support critically ill respiratory failure patients. Current standards of care consist of generalised approaches, such as the use of positive end expiratory pressure to inspired oxygen fraction (PEEP-FiO2) tables, which fail to account for the inter- and intra-patient variability between and within patients. The benefits of higher or lower tidal volume, PEEP, and other settings are highly debated and no consensus has been reached. Moreover, clinicians implicitly account for patient-specific factors such as disease condition and progression as they manually titrate ventilator settings. Hence, care is highly variable and potentially often non-optimal. These conditions create a situation that could benefit greatly from an engineered approach. The overall goal is a review of ventilation that is accessible to both clinicians and engineers, to bridge the divide between the two fields and enable collaboration to improve patient care and outcomes. This review does not take the form of a typical systematic review. Instead, it defines the standard terminology and introduces key clinical and biomedical measurements before introducing the key clinical studies and their influence in clinical practice which in turn flows into the needs and requirements around how biomedical engineering research can play a role in improving care. Given the significant clinical research to date and its impact on this complex area of care, this review thus provides a tutorial introduction around the review of the state of the art relevant to a biomedical engineering perspective.

    DISCUSSION: This review presents the significant clinical aspects and variables of ventilation management, the potential risks associated with suboptimal ventilation management, and a review of the major recent attempts to improve ventilation in the context of these variables. The unique aspect of this review is a focus on these key elements relevant to engineering new approaches. In particular, the need for ventilation strategies which consider, and directly account for, the significant differences in patient condition, disease etiology, and progression within patients is demonstrated with the subsequent requirement for optimal ventilation strategies to titrate for patient- and time-specific conditions.

    CONCLUSION: Engineered, protective lung strategies that can directly account for and manage inter- and intra-patient variability thus offer great potential to improve both individual care, as well as cohort clinical outcomes.

  5. Ang CYS, Chiew YS, Vu LH, Cove ME
    Comput Methods Programs Biomed, 2022 Mar;215:106601.
    PMID: 34973606 DOI: 10.1016/j.cmpb.2021.106601
    BACKGROUND: Spontaneous breathing (SB) effort during mechanical ventilation (MV) is an important metric of respiratory drive. However, SB effort varies due to a variety of factors, including evolving pathology and sedation levels. Therefore, assessment of SB efforts needs to be continuous and non-invasive. This is important to prevent both over- and under-assistance with MV. In this study, a machine learning model, Convolutional Autoencoder (CAE) is developed to quantify the magnitude of SB effort using only bedside MV airway pressure and flow waveform.

    METHOD: The CAE model was trained using 12,170,655 simulated SB flow and normal flow data (NB). The paired SB and NB flow data were simulated using a Gaussian Effort Model (GEM) with 5 basis functions. When the CAE model is given a SB flow input, it is capable of predicting a corresponding NB flow for the SB flow input. The magnitude of SB effort (SBEMag) is then quantified as the difference between the SB and NB flows. The CAE model was used to evaluate the SBEMag of 9 pressure control/ support datasets. Results were validated using a mean squared error (MSE) fitting between clinical and training SB flows.

    RESULTS: The CAE model was able to produce NB flows from the clinical SB flows with the median SBEMag of the 9 datasets being 25.39% [IQR: 21.87-25.57%]. The absolute error in SBEMag using MSE validation yields a median of 4.77% [IQR: 3.77-8.56%] amongst the cohort. This shows the ability of the GEM to capture the intrinsic details present in SB flow waveforms. Analysis also shows both intra-patient and inter-patient variability in SBEMag.

    CONCLUSION: A Convolutional Autoencoder model was developed with simulated SB and NB flow data and is capable of quantifying the magnitude of patient spontaneous breathing effort. This provides potential application for real-time monitoring of patient respiratory drive for better management of patient-ventilator interaction.

  6. Wong JW, Chiew YS, Desaive T, Chase JG
    IFAC Pap OnLine, 2021;54(15):121-126.
    PMID: 38620762 DOI: 10.1016/j.ifacol.2021.10.242
    Surges of COVID-19 infections could lead to insufficient supply of mechanical ventilators, and rationing of needed care. Multiplexing mechanical ventilators (co-MV) to serve multiple patients is a potential temporary solution. However, if patients are ventilated in parallel ventilation, there is currently no means to match ventilation requirements or patients, with no guidelines to date for co-MV. This research uses patient-specific clinically validated respiratory mechanics models to propose a method for patient matching and mechanical ventilator settings for two-patient co-MV under pressure control mode. The proposed method can simulate and estimate the resultant tidal volume of different combinations of co-ventilated patients. With both patients fulfilling the specified constraint under similar ventilation settings, the actual mechanical ventilator settings for co-MV are determined. This method allows clinicians to analyze in silico co-MV before clinical implementation.
  7. Wong JW, Chiew YS, Desaive T, Chase JG
    Biomed Eng Online, 2022 Feb 09;21(1):11.
    PMID: 35139858 DOI: 10.1186/s12938-022-00983-y
    BACKGROUND: Surges of COVID-19 infections have led to insufficient supply of mechanical ventilators (MV), resulting in rationing of MV care. In-parallel, co-mechanical ventilation (Co-MV) of multiple patients is a potential solution. However, due to lack of testing, there is currently no means to match ventilation requirements or patients, with no guidelines to date. In this research, we have developed a model-based method for patient matching for pressure control mode MV.

    METHODS: The model-based method uses a single-compartment lung model (SCM) to simulate the resultant tidal volume of patient pairs at a set ventilation setting. If both patients meet specified safe ventilation criteria under similar ventilation settings, the actual mechanical ventilator settings for Co-MV are determined via simulation using a double-compartment lung model (DCM). This method allows clinicians to analyse Co-MV in silico, before clinical implementation.

    RESULTS: The proposed method demonstrates successful patient matching and MV setting in a model-based simulation as well as good discrimination to avoid mismatched patient pairs. The pairing process is based on model-based, patient-specific respiratory mechanics identified from measured data to provide useful information for guiding care. Specifically, the matching is performed via estimation of MV delivered tidal volume (mL/kg) based on patient-specific respiratory mechanics. This information can provide insights for the clinicians to evaluate the subsequent effects of Co-MV. In addition, it was also found that Co-MV patients with highly restrictive respiratory mechanics and obese patients must be performed with extra care.

    CONCLUSION: This approach allows clinicians to analyse patient matching in a virtual environment without patient risk. The approach is tested in simulation, but the results justify the necessary clinical validation in human trials.

  8. Morton SE, Chiew YS, Pretty C, Moltchanova E, Scarrott C, Redmond D, et al.
    Math Biosci, 2017 02;284:21-31.
    PMID: 27301378 DOI: 10.1016/j.mbs.2016.06.001
    Randomised control trials have sought to seek to improve mechanical ventilation treatment. However, few trials to date have shown clinical significance. It is hypothesised that aside from effective treatment, the outcome metrics and sample sizes of the trial also affect the significance, and thus impact trial design. In this study, a Monte-Carlo simulation method was developed and used to investigate several outcome metrics of ventilation treatment, including 1) length of mechanical ventilation (LoMV); 2) Ventilator Free Days (VFD); and 3) LoMV-28, a combination of the other metrics. As these metrics have highly skewed distributions, it also investigated the impact of imposing clinically relevant exclusion criteria on study power to enable better design for significance. Data from invasively ventilated patients from a single intensive care unit were used in this analysis to demonstrate the method. Use of LoMV as an outcome metric required 160 patients/arm to reach 80% power with a clinically expected intervention difference of 25% LoMV if clinically relevant exclusion criteria were applied to the cohort, but 400 patients/arm if they were not. However, only 130 patients/arm would be required for the same statistical significance at the same intervention difference if VFD was used. A Monte-Carlo simulation approach using local cohort data combined with objective patient selection criteria can yield better design of ventilation studies to desired power and significance, with fewer patients per arm than traditional trial design methods, which in turn reduces patient risk. Outcome metrics, such as VFD, should be used when a difference in mortality is also expected between the two cohorts. Finally, the non-parametric approach taken is readily generalisable to a range of trial types where outcome data is similarly skewed.
  9. Chase JG, Chiew YS, Lambermont B, Morimont P, Shaw GM, Desaive T
    Crit Care, 2020 05 14;24(1):222.
    PMID: 32410701 DOI: 10.1186/s13054-020-02945-z
  10. Lee CC, Tran MV, Choo CW, Tan CP, Chiew YS
    Environ Pollut, 2020 Oct;265(Pt A):115058.
    PMID: 32806396 DOI: 10.1016/j.envpol.2020.115058
    Due to the increase of the human population and the rapid industrial growth in the past few decades, air quality monitoring is essential to assess the pollutant levels of an area. However, monitoring air quality in a high-density area like Sunway City, Selangor, Malaysia is challenging due to the limitation of the local monitoring network. To establish a comprehensive data for air pollution in Sunway City, a mobile monitoring campaign was employed around the city area with a duration of approximately 6 months, from September 2018 to March 2019. Measurements of air pollutants such as carbon dioxide (CO2) and nitrogen dioxide (NO2) were performed by using mobile air pollution sensors facilitated with a GPS device. In order to acquire a more in-depth understanding on traffic-related air pollution, the measurement period was divided into two different time blocks, which were morning hours (8 a.m.-12 p.m.) and afternoon hours (3 p.m.-7 p.m.). The data set was analysed by splitting Sunway City into different zones and routes to differentiate the conditions of each region. Meteorological variables such as ambient temperature, relative humidity, and wind speed were studied in line with the pollutant concentrations. The air quality in Sunway City was then compared with various air quality standards such as Malaysian Air Quality Standards and World Health Organisation (WHO) guidelines to understand the risk of exposure to air pollution by the residence in Sunway City.
  11. Chase JG, Chiew YS, Lambermont B, Morimont P, Shaw GM, Desaive T
    Crit Care, 2020 07 10;24(1):415.
    PMID: 32650807 DOI: 10.1186/s13054-020-03152-6
  12. Chiew YS, Pretty CG, Shaw GM, Chiew YW, Lambermont B, Desaive T, et al.
    PMID: 28435689 DOI: 10.1186/s40814-015-0006-2
    BACKGROUND: Selecting positive end-expiratory pressure (PEEP) during mechanical ventilation is important, as it can influence disease progression and outcome of acute respiratory distress syndrome (ARDS) patients. However, there are no well-established methods for optimizing PEEP selection due to the heterogeneity of ARDS. This research investigates the viability of titrating PEEP to minimum elastance for mechanically ventilated ARDS patients.

    METHODS: Ten mechanically ventilated ARDS patients from the Christchurch Hospital Intensive Care Unit were included in this study. Each patient underwent a stepwise PEEP recruitment manoeuvre. Airway pressure and flow data were recorded using a pneumotachometer. Patient-specific respiratory elastance (Ers ) and dynamic functional residual capacity (dFRC) at each PEEP level were calculated and compared. Optimal PEEP for each patient was identified by finding the minima of the PEEP-Ers profile.

    RESULTS: Median Ers and dFRC over all patients and PEEP values were 32.2 cmH2O/l [interquartile range (IQR) 25.0-45.9] and 0.42 l [IQR 0.11-0.87]. These wide ranges reflect patient heterogeneity and variable response to PEEP. The level of PEEP associated with minimum Ers corresponds to a high change of functional residual capacity, representing the balance between recruitment and minimizing the risk of overdistension.

    CONCLUSIONS: Monitoring patient-specific Ers can provide clinical insight to patient-specific condition and response to PEEP settings. The level of PEEP associated with minimum-Ers can be identified for each patient using a stepwise PEEP recruitment manoeuvre. This 'minimum elastance PEEP' may represent a patient-specific optimal setting during mechanical ventilation.

    TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry: ACTRN12611001179921.

  13. Guo P, Chiew YS, Shaw GM, Shao L, Green R, Clark A, et al.
    Intensive Crit Care Nurs, 2016 Dec;37:52-61.
    PMID: 27401048 DOI: 10.1016/j.iccn.2016.05.003
    Monitoring clinical activity at the bedside in the intensive care unit (ICU) can provide useful information to evaluate nursing care and patient recovery. However, it is labour intensive to quantify these activities and there is a need for an automated method to record and quantify these activities. This paper presents an automated system, Clinical Activity Tracking System (CATS), to monitor and evaluate clinical activity at the patient's bedside. The CATS uses four Microsoft Kinect infrared sensors to track bedside nursing interventions. The system was tested in a simulated environment where test candidates performed different motion paths in the detection area. Two metrics, 'Distance' and 'Dwell time', were developed to evaluate interventions or workload in the detection area. Results showed that the system can accurately track the intervention performed by individual or multiple subjects. The results of a 30-day, 24-hour preliminary study in an ICU bed space matched clinical expectations. It was found that the average 24-hour intervention is 22.0minutes/hour. The average intervention during the day time (7am-11pm) is 23.6minutes/hour, 1.4 times higher than 11pm-7am, 16.8minutes/hour. This system provides a unique approach to automatically collect and evaluate nursing interventions that can be used to evaluate patient acuity and workload demand.
  14. Arunachalam GR, Chiew YS, Tan CP, Ralib AM, Nor MBM
    Comput Methods Programs Biomed, 2020 Jan;183:105103.
    PMID: 31606559 DOI: 10.1016/j.cmpb.2019.105103
    BACKGROUND AND OBJECTIVE: Mechanical ventilation therapy of respiratory failure patients can be guided by monitoring patient-specific respiratory mechanics. However, the patient's spontaneous breathing effort during controlled ventilation changes airway pressure waveform and thus affects the model-based identification of patient-specific respiratory mechanics parameters. This study develops a model to estimate respiratory mechanics in the presence of patient effort.

    METHODS: Gaussian effort model (GEM) is a derivative of the single-compartment model with basis function. GEM model uses a linear combination of basis functions to model the nonlinear pressure waveform of spontaneous breathing patients. The GEM model estimates respiratory mechanics such as Elastance and Resistance along with the magnitudes of basis functions, which accounts for patient inspiratory effort.

    RESULTS AND DISCUSSION: The GEM model was tested using both simulated data and a retrospective observational clinical trial patient data. GEM model fitting to the original airway pressure waveform is better than any existing models when reverse triggering asynchrony is present. The fitting error of GEM model was less than 10% for both simulated data and clinical trial patient data.

    CONCLUSION: GEM can capture the respiratory mechanics in the presence of patient effect in volume control ventilation mode and also can be used to assess patient-ventilator interaction. This model determines basis functions magnitudes, which can be used to simulate any waveform of patient effort pressure for future studies. The estimation of parameter identification GEM model can further be improved by constraining the parameters within a physiologically plausible range during least-square nonlinear regression.

  15. Muhamad Sauki NS, Damanhuri NS, Othman NA, Chiew Meng BC, Chiew YS, Mat Nor MB
    Bioengineering (Basel), 2021 Dec 18;8(12).
    PMID: 34940375 DOI: 10.3390/bioengineering8120222
    Respiratory system modelling can assist clinicians in making clinical decisions during mechanical ventilation (MV) management in intensive care. However, there are some cases where the MV patients produce asynchronous breathing (asynchrony events) due to the spontaneous breathing (SB) effort even though they are fully sedated. Currently, most of the developed models are only suitable for fully sedated patients, which means they cannot be implemented for patients who produce asynchrony in their breathing. This leads to an incorrect measurement of the actual underlying mechanics in these patients. As a result, there is a need to develop a model that can detect asynchrony in real-time and at the bedside throughout the ventilated days. This paper demonstrates the asynchronous event detection of MV patients in the ICU of a hospital by applying a developed extended time-varying elastance model. Data from 10 mechanically ventilated respiratory failure patients admitted at the International Islamic University Malaysia (IIUM) Hospital were collected. The results showed that the model-based technique precisely detected asynchrony events (AEs) throughout the ventilation days. The patients showed an increase in AEs during the ventilation period within the same ventilation mode. SIMV mode produced much higher asynchrony compared to SPONT mode (p < 0.05). The link between AEs and the lung elastance (AUC Edrs) was also investigated. It was found that when the AEs increased, the AUC Edrs decreased and vice versa based on the results obtained in this research. The information of AEs and AUC Edrs provides the true underlying lung mechanics of the MV patients. Hence, this model-based method is capable of detecting the AEs in fully sedated MV patients and providing information that can potentially guide clinicians in selecting the optimal ventilation mode of MV, allowing for precise monitoring of respiratory mechanics in MV patients.
  16. Chiew YS, Tan CP, Chase JG, Chiew YW, Desaive T, Ralib AM, et al.
    Comput Methods Programs Biomed, 2018 Apr;157:217-224.
    PMID: 29477430 DOI: 10.1016/j.cmpb.2018.02.007
    BACKGROUND AND OBJECTIVE: Respiratory mechanics estimation can be used to guide mechanical ventilation (MV) but is severely compromised when asynchronous breathing occurs. In addition, asynchrony during MV is often not monitored and little is known about the impact or magnitude of asynchronous breathing towards recovery. Thus, it is important to monitor and quantify asynchronous breathing over every breath in an automated fashion, enabling the ability to overcome the limitations of model-based respiratory mechanics estimation during asynchronous breathing ventilation.

    METHODS: An iterative airway pressure reconstruction (IPR) method is used to reconstruct asynchronous airway pressure waveforms to better match passive breathing airway waveforms using a single compartment model. The reconstructed pressure enables estimation of respiratory mechanics of airway pressure waveform essentially free from asynchrony. Reconstruction enables real-time breath-to-breath monitoring and quantification of the magnitude of the asynchrony (MAsyn).

    RESULTS AND DISCUSSION: Over 100,000 breathing cycles from MV patients with known asynchronous breathing were analyzed. The IPR was able to reconstruct different types of asynchronous breathing. The resulting respiratory mechanics estimated using pressure reconstruction were more consistent with smaller interquartile range (IQR) compared to respiratory mechanics estimated using asynchronous pressure. Comparing reconstructed pressure with asynchronous pressure waveforms quantifies the magnitude of asynchronous breathing, which has a median value MAsyn for the entire dataset of 3.8%.

    CONCLUSION: The iterative pressure reconstruction method is capable of identifying asynchronous breaths and improving respiratory mechanics estimation consistency compared to conventional model-based methods. It provides an opportunity to automate real-time quantification of asynchronous breathing frequency and magnitude that was previously limited to invasively method only.

  17. Ang CYS, Chiew YS, Wang X, Mat Nor MB, Cove ME, Chase JG
    Comput Biol Med, 2022 Dec;151(Pt A):106275.
    PMID: 36375413 DOI: 10.1016/j.compbiomed.2022.106275
    BACKGROUND AND OBJECTIVE: Respiratory mechanics of mechanically ventilated patients evolve significantly with time, disease state and mechanical ventilation (MV) treatment. Existing deterministic data prediction methods fail to comprehensively describe the multiple sources of heterogeneity of biological systems. This research presents two respiratory mechanics stochastic models with increased prediction accuracy and range, offering improved clinical utility in MV treatment.

    METHODS: Two stochastic models (SM2 and SM3) were developed using retrospective patient respiratory elastance (Ers) from two clinical cohorts which were averaged over time intervals of 10 and 30 min respectively. A stochastic model from a previous study (SM1) was used to benchmark performance. The stochastic models were clinically validated on an independent retrospective clinical cohort of 14 patients. Differences in predictive ability were evaluated using the difference in percentile lines and cumulative distribution density (CDD) curves.

    RESULTS: Clinical validation shows all three models captured more than 98% (median) of future Ers data within the 5th - 95th percentile range. Comparisons of stochastic model percentile lines reported a maximum mean absolute percentage difference of 5.2%. The absolute differences of CDD curves were less than 0.25 in the ranges of 5 

  18. Tan ZQ, Ooi EH, Chiew YS, Foo JJ, Ng EYK, Ooi ET
    Ultrasonics, 2023 May;131:106961.
    PMID: 36812819 DOI: 10.1016/j.ultras.2023.106961
    Sonothrombolysis is a technique that utilises ultrasound waves to excite microbubbles surrounding a clot. Clot lysis is achieved through mechanical damage induced by acoustic cavitation and through local clot displacement induced by acoustic radiation force (ARF). Despite the potential of microbubble-mediated sonothrombolysis, the selection of the optimal ultrasound and microbubble parameters remains a challenge. Existing experimental studies are not able to provide a complete picture of how ultrasound and microbubble characteristics influence the outcome of sonothrombolysis. Likewise, computational studies have not been applied in detail in the context of sonothrombolysis. Hence, the effect of interaction between the bubble dynamics and acoustic propagation on the acoustic streaming and clot deformation remains unclear. In the present study, we report for the first time the computational framework that couples the bubble dynamic phenomena with the acoustic propagation in a bubbly medium to simulate microbubble-mediated sonothrombolysis using a forward-viewing transducer. The computational framework was used to investigate the effects of ultrasound properties (pressure and frequency) and microbubble characteristics (radius and concentration) on the outcome of sonothrombolysis. Four major findings were obtained from the simulation results: (i) ultrasound pressure plays the most dominant role over all the other parameters in affecting the bubble dynamics, acoustic attenuation, ARF, acoustic streaming, and clot displacement, (ii) smaller microbubbles could contribute to a more violent oscillation and improve the ARF simultaneously when they are stimulated at higher ultrasound pressure, (iii) higher microbubbles concentration increases the ARF, and (iv) the effect of ultrasound frequency on acoustic attenuation is dependent on the ultrasound pressure. These results may provide fundamental insight that is crucial in bringing sonothrombolysis closer to clinical implementation.
  19. Lee JWW, Chiew YS, Wang X, Mat Nor MB, Chase JG, Desaive T
    Biomed Eng Online, 2022 Feb 11;21(1):13.
    PMID: 35148759 DOI: 10.1186/s12938-022-00981-0
    BACKGROUND AND OBJECTIVE: Mechanical ventilation (MV) is the primary form of care for respiratory failure patients. MV settings are based on general clinical guidelines, intuition, and experience. This approach is not patient-specific and patients may thus experience suboptimal, potentially harmful MV care. This study presents the Stochastic integrated VENT (SiVENT) protocol which combines model-based approaches of the VENT protocol from previous works, with stochastic modelling to take the variation of patient respiratory elastance over time into consideration.

    METHODS: A stochastic model of Ers is integrated into the VENT protocol from previous works to develop the SiVENT protocol, to account for both intra- and inter-patient variability. A cohort of 20 virtual MV patients based on retrospective patient data are used to validate the performance of this method for volume-controlled (VC) ventilation. A performance evaluation was conducted where the SiVENT and VENT protocols were implemented in 1080 instances each to compare the two protocols and evaluate the difference in reduction of possible MV settings achieved by each.

    RESULTS: From an initial number of 189,000 possible MV setting combinations, the VENT protocol reduced this number to a median of 10,612, achieving a reduction of 94.4% across the cohort. With the integration of the stochastic model component, the SiVENT protocol reduced this number from 189,000 to a median of 9329, achieving a reduction of 95.1% across the cohort. The SiVENT protocol reduces the number of possible combinations provided to the user by more than 1000 combinations as compared to the VENT protocol.

    CONCLUSIONS: Adding a stochastic model component into a model-based approach to selecting MV settings improves the ability of a decision support system to recommend patient-specific MV settings. It specifically considers inter- and intra-patient variability in respiratory elastance and eliminates potentially harmful settings based on clinically recommended pressure thresholds. Clinical input and local protocols can further reduce the number of safe setting combinations. The results for the SiVENT protocol justify further investigation of its prediction accuracy and clinical validation trials.