Displaying all 4 publications

Abstract:
Sort:
  1. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH
    Sensors (Basel), 2019 May 14;19(10).
    PMID: 31091779 DOI: 10.3390/s19102226
    Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes - including light-emitting diodes (LEDs), phototransistors-including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.
  2. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH
    Phys Med Biol, 2021 Apr 12;66(8).
    PMID: 33725685 DOI: 10.1088/1361-6560/abef44
    Light-emitting diodes (LEDs) could be a potential dosimetry candidate because they are radiation hard, spectrally selective, direct band gap, and low-cost devices. Thus, an LED-based detector prototype was designed and characterized for dosimetry. A 20 × 20 cm2array of surface mount device LED chips was sandwiched in photovoltaic mode between two intensifying screens to form a dosimetric system. The system was enclosed in a light-tight air cavity using black vinyl tape. The screens converted diagnostic x-ray beams into fluorescent blue light. LEDs, applied in detector mode, converted the fluorescent light into radiation-induced currents. A digital multimeter converted the analog currents into digital voltage signals. Prototype characterization was executed using (a) IEC 61267's RQR 7 (90 kVp) and RQR 8 (100 kVp) beam qualities, and (b) low (25 mAs) and high (80 mAs) beam quantities. A standard dosimeter probe was simultaneously exposed with the prototype to measure the prototype's absorbed dose. In all exposures, the x-ray beams were perpendicularly incident on both the dosimeter and prototype, at a fixed source to detector distance-60 cm. The LED array prototype's minimum detectable dose was 0.139 mGy, and the maximum dose implemented herein was ∼13 mGy. The prototype was 99.18% and 98.64% linearly sensitive to absorbed dose and tube current-time product (mAs), respectively. The system was ±4.69% energy, ±6.8% dose, and ±7.7% dose rate dependent. Two prototype data sets were 89.93% repeatable. We fabricated an ultrathin (5 mm), lightweight (130 g), and a relatively low-cost LED-based dosimetric prototype. The prototype executed a simple, efficient, and accurate real-time dosimetric mechanism. It could thus be an alternative to the current passive dosimetric systems.
  3. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH, Ahmed NM
    Appl Radiat Isot, 2021 Apr;170:109622.
    PMID: 33592486 DOI: 10.1016/j.apradiso.2021.109622
    This study compares the real-time dosimetric performance of a bpw34 photodiode (PD) and cold white light-emitting diodes (LEDs) based on diagnostic X-ray-induced signals. Signals were extracted when both the transducers were under identical exposure settings, including source-to-detector distance (SDD), tube voltage (kVp), and current-time product (mAs). The transducers were in a photovoltaic configuration, and black vinyl tape was applied on transducer active areas as a form of optical shielding. X-ray beam spectra and energies were simulated using Matlab-based Spektr functions. Transducer performance analysis was based on signal linearity to mAs and air kerma, and sensitivity dependence on absorbed dose, energy, and dose rate. Bpw34 PD and cold white LED output signals were 84.8% and 85.5% precise, respectively. PD signals were 94.7% linear to mAs, whereas LED signals were 91.9%. PD and LED signal linearity to dose coefficients were 0.9397 and 0.9128, respectively. Both transducers exhibited similar dose and energy dependence. However, cold white LEDs were 0.73% less dose rate dependent than the bpw34 PD. Cold white LEDs demonstrated potential in detecting diagnostic X-rays because their performance was similar to that of the bpw34 PD. Moreover, the cold white LED array's dosimetric response was independent of the heel effect. Although cold white LED signals were lower than bpw34 PD signals, they were quantifiable and electronically amplifiable.
  4. Tagiling N, Ibrahim IL, Lee YY, Udin MY, Mohamad Kamarulzaman MD, Phoa PKA, et al.
    PMID: 38705971 DOI: 10.1111/jgh.16585
    BACKGROUND AND AIM: Measurements of gastric emptying and accommodation for alternative test-meal protocol during gastric emptying scintigraphy (GES), such as high-calorie nutrient drinks, are not fully established. We aimed to compare the effects of standardized egg-white meal (EWM) versus high-calorie nutrient drink (Vital®; Abbott Laboratories) on global GES parameters and intragastric meal distribution at immediate scan (IMD0h).

    METHODS: Of 84 screened participants, 60 asymptomatic healthy Asian population (38 females; 24.0 ± 1.5 years; 23.8 ± 2.6 kg/m2) were recruited in this 2 × 2 (AB/BA) crossover trial. Participants were randomized to a 4-h GES with 99mTc-radiolabeled EWM (~255.8 kcal), followed by a 200 mL Vital® (300 kcal), or vice versa, separated by a 2-week washout period. Global meal retention (GMR), power-exponential model emptying parameters (half-emptying [T1/2], lag phases [Tlag2%, Tlag5%, Tlag10%]), and IMD0h were determined and compared.

    RESULTS: GMRs for both test meals were within the international standard references for solid GES. Compared to EWM, Vital® exhibited significantly lower GMRs (faster emptying) from 0.5 to 3 h (all P 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links