Displaying all 11 publications

Abstract:
Sort:
  1. Al-Faqheri W, Ibrahim F, Thio TH, Moebius J, Joseph K, Arof H, et al.
    PLoS One, 2013;8(3):e58523.
    PMID: 23505528 DOI: 10.1371/journal.pone.0058523
    This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control.
  2. Thio TH, Soroori S, Ibrahim F, Al-Faqheri W, Soin N, Kulinsky L, et al.
    Med Biol Eng Comput, 2013 May;51(5):525-35.
    PMID: 23292292 DOI: 10.1007/s11517-012-1020-7
    This paper presents a theoretical development and critical analysis of the burst frequency equations for capillary valves on a microfluidic compact disc (CD) platform. This analysis includes background on passive capillary valves and the governing models/equations that have been developed to date. The implicit assumptions and limitations of these models are discussed. The fluid meniscus dynamics before bursting is broken up into a multi-stage model and a more accurate version of the burst frequency equation for the capillary valves is proposed. The modified equations are used to evaluate the effects of various CD design parameters such as the hydraulic diameter, the height to width aspect ratio, and the opening wedge angle of the channel on the burst pressure.
  3. Joseph K, Ibrahim F, Cho J, Thio TH, Al-Faqheri W, Madou M
    PLoS One, 2015;10(9):e0136519.
    PMID: 26422249 DOI: 10.1371/journal.pone.0136519
    The development of micro-power generators for centrifugal microfluidic discs enhances the platform as a green point-of-care diagnostic system and eliminates the need for attaching external peripherals to the disc. In this work, we present micro-power generators that harvest energy from the disc's rotational movement to power biomedical applications on the disc. To implement these ideas, we developed two types of micro-power generators using piezoelectric films and an electromagnetic induction system. The piezoelectric-based generator takes advantage of the film's vibration during the disc's rotational motion, whereas the electromagnetic induction-based generator operates on the principle of current generation in stacks of coil exposed to varying magnetic flux. We have successfully demonstrated that at the spinning speed of 800 revolutions per minute (RPM) the piezoelectric film-based generator is able to produce up to 24 microwatts using 6 sets of films and the magnetic induction-based generator is capable of producing up to 125 milliwatts using 6 stacks of coil. As a proof of concept, a custom made localized heating system was constructed to test the capability of the magnetic induction-based generator. The heating system was able to achieve a temperature of 58.62 °C at 2200 RPM. This development of lab-on-a-disc micro power generators preserves the portability standards and enhances the future biomedical applications of centrifugal microfluidic platforms.
  4. Aeinehvand MM, Ibrahim F, Harun SW, Kazemzadeh A, Rothan HA, Yusof R, et al.
    Lab Chip, 2015 Aug 21;15(16):3358-69.
    PMID: 26158597 DOI: 10.1039/c5lc00634a
    Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the microfluidic networks are validated on a microfluidic disk designed for performing liquid circulation. Finally, an array of RTPVs is integrated into a microfluidic cartridge to enable sequential aliquoting for the conversion of dengue virus RNA to cDNA and the preparation of PCR reaction mixtures.
  5. Thio TH, Ibrahim F, Al-Faqheri W, Soin N, Kahar Bador M, Madou M
    PLoS One, 2015;10(4):e0121836.
    PMID: 25853411 DOI: 10.1371/journal.pone.0121836
    A centrifugal compact disc (CD) microfluidic platform with reservoirs, micro-channels, and valves can be employed for implementing a complete immunoassay. Detection or biosensor chambers are either coated for immuno-interaction or a biosensor chip is inserted in them. On microfluidic CDs featuring such multi-step chemical/biological processes, the biosensor chamber must be repeatedly filled with fluids such as enzymes solutions, buffers, and washing solutions. After each filling step, the biosensor chamber needs to be evacuated by a passive siphoning process to prepare it for the next step in the assay. However, rotational speed dependency and limited space on a CD are two big obstacles to performing such repetitive filling and siphoning steps. In this work, a unique thermo-pneumatic (TP) Push-Pull pumping method is employed to provide a superior alternative biosensor chamber filling and evacuation technique. The proposed technique is demonstrated on two CD designs. The first design features a simple two-step microfluidic process to demonstrate the evacuation technique, while the second design shows the filling and evacuation technique with an example sequence for an actual immunoassay. In addition, the performance of the filling and evacuation technique as a washing step is also evaluated quantitatively and compared to the conventional manual bench top washing method. The two designs and the performance evaluation demonstrate that the technique is simple to implement, reliable, easy to control, and allows for repeated push-pulls and thus filling and emptying of the biosensor chamber. Furthermore, by addressing the issue of rotational speed dependency and limited space concerns in implementing repetitive filling and evacuation steps, this newly introduced technique increases the flexibility of the microfluidic CD platform to perform multi-step biological and chemical processes.
  6. Sayad A, Ibrahim F, Mukim Uddin S, Cho J, Madou M, Thong KL
    Biosens Bioelectron, 2018 Feb 15;100:96-104.
    PMID: 28869845 DOI: 10.1016/j.bios.2017.08.060
    Outbreaks of foodborne diseases have become a global health concern; hence, many improvements and developments have been made to reduce the risk of food contamination. We developed a centrifugal microfluidic automatic wireless endpoint detection system integrated with loop mediated isothermal amplification (LAMP) for monoplex pathogen detection. Six identical sets were designed on the microfluidic compact disc (CD) to perform 30 genetic analyses of three different species of foodborne pathogens. The consecutive loading, mixing, and aliquoting of the LAMP primers/reagents and DNA sample solutions were accomplished using an optimized square-wave microchannel, metering chambers and revulsion per minute (RPM) control. We tested 24 strains of pathogenic bacteria (Escherichia coli, Salmonella spp and Vibrio cholerae), with 8 strains of each bacterium, and performed DNA amplification on the microfluidic CD for 60min. Then, the amplicons of the LAMP reaction were detected using the calcein colorimetric method and further analysed via the developed electronic system interfaced with Bluetooth wireless technology to transmit the results to a smartphone. The system showed a limit of detection (LOD) of 3 × 10-5ngμL-1 DNA by analysing the colour change when tested with chicken meat spiked with the three pathogenic bacteria. Since the entire process was performed in a fully automated way and was easy to use, our microdevice is suitable for point-of-care (POC) testing with high simplicity, providing affordability and accessibility even to poor, resource-limited settings.
  7. Thiha A, Ibrahim F, Muniandy S, Dinshaw IJ, Teh SJ, Thong KL, et al.
    Biosens Bioelectron, 2018 Jun 01;107:145-152.
    PMID: 29455024 DOI: 10.1016/j.bios.2018.02.024
    Nanowire sensors offer great potential as highly sensitive electrochemical and electronic biosensors because of their small size, high aspect ratios, and electronic properties. Nevertheless, the available methods to fabricate carbon nanowires in a controlled manner remain limited to expensive techniques. This paper presents a simple fabrication technique for sub-100 nm suspended carbon nanowire sensors by integrating electrospinning and photolithography techniques. Carbon Microelectromechanical Systems (C-MEMS) fabrication techniques allow fabrication of high aspect ratio carbon structures by patterning photoresist polymers into desired shapes and subsequent carbonization of resultant structures by pyrolysis. In our sensor platform, suspended nanowires were deposited by electrospinning while photolithography was used to fabricate support structures. We have achieved suspended carbon nanowires with sub-100 nm diameters in this study. The sensor platform was then integrated with a microfluidic chip to form a lab-on-chip device for label-free chemiresistive biosensing. We have investigated this nanoelectronics label-free biosensor's performance towards bacterial sensing by functionalization with Salmonella-specific aptamer probes. The device was tested with varying concentrations of Salmonella Typhimurium to evaluate sensitivity and various other bacteria to investigate specificity. The results showed that the sensor is highly specific and sensitive in detection of Salmonella with a detection limit of 10 CFU mL-1. Moreover, this proposed chemiresistive assay has a reduced turnaround time of 5 min and sample volume requirement of 5 µL which are much less than reported in the literature.
  8. Aeinehvand MM, Ibrahim F, Harun SW, Al-Faqheri W, Thio TH, Kazemzadeh A, et al.
    Lab Chip, 2014 Mar 07;14(5):988-97.
    PMID: 24441792 DOI: 10.1039/c3lc51116b
    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.
  9. Thio TH, Ibrahim F, Al-Faqheri W, Moebius J, Khalid NS, Soin N, et al.
    Lab Chip, 2013 Aug 21;13(16):3199-209.
    PMID: 23774994 DOI: 10.1039/c3lc00004d
    A technique known as thermo-pneumatic (TP) pumping is used to pump fluids on a microfluidic compact disc (CD) back towards the CD center against the centrifugal force that pushes liquids from the center to the perimeter of the disc. Trapped air expands in a TP air chamber during heating, and this creates positive pressure on liquids located in chambers connected to that chamber. While the TP air chamber and connecting channels are easy to fabricate in a one-level CD manufacturing technique, this approach provides only one way pumping between two chambers, is real-estate hungry and leads to unnecessary heating of liquids in close proximity to the TP chamber. In this paper, we present a novel TP push and pull pumping method which allows for pumping of liquid in any direction between two connected liquid chambers. To ensure that implementation of TP push and pull pumping also addresses the issue of space and heating challenges, a multi-level 3D CD design is developed, and localized forced convection heating, rather than infra-red (IR) is applied. On a multi-level 3D CD, the TP features are placed on a top level separate from the rest of the microfluidic processes that are implemented on a lower separate level. This approach allows for heat shielding of the microfluidic process level, and efficient usage of space on the CD for centrifugal handling of liquids. The use of localized forced convection heating, rather than infra-red (IR) or laser heating in earlier implementations allows not only for TP pumping of liquids while the CD is spinning but also makes heat insulation for TP pumping and other fluidic functions easier. To aid in future implementations of TP push and pull pumping on a multi-level 3D CD, study on CD surface heating is also presented. In this contribution, we also demonstrate an advanced application of pull pumping through the implementation of valve-less switch pumping.
  10. Al-Faqheri W, Ibrahim F, Thio TH, Bahari N, Arof H, Rothan HA, et al.
    Sensors (Basel), 2015 Feb 25;15(3):4658-76.
    PMID: 25723143 DOI: 10.3390/s150304658
    In this paper, we propose an easy-to-implement passive liquid valve (PLV) for the microfluidic compact-disc (CD). This valve can be implemented by introducing venting chambers to control the air flow of the source and destination chambers. The PLV mechanism is based on equalizing the main forces acting on the microfluidic CD (i.e., the centrifugal and capillary forces) to control the burst frequency of the source chamber liquid. For a better understanding of the physics behind the proposed PLV, an analytical model is described. Moreover, three parameters that control the effectiveness of the proposed valve, i.e., the liquid height, liquid density, and venting chamber position with respect to the CD center, are tested experimentally. To demonstrate the ability of the proposed PLV valve, microfluidic liquid switching and liquid metering are performed. In addition, a Bradford assay is performed to measure the protein concentration and evaluated in comparison to the benchtop procedure. The result shows that the proposed valve can be implemented in any microfluidic process that requires simplicity and accuracy. Moreover, the developed valve increases the flexibility of the centrifugal CD platform for passive control of the liquid flow without the need for an external force or trigger.
  11. Aeinehvand MM, Weber L, Jiménez M, Palermo A, Bauer M, Loeffler FF, et al.
    Lab Chip, 2019 Feb 20.
    PMID: 30785443 DOI: 10.1039/c8lc00849c
    Reversible valves on centrifugal microfluidic platforms facilitate the automation of bioanalytical assays, especially of those requiring a series of steps (such as incubation) in a single reaction chamber. In this study, we present fixed elastic reversible (FER) valves and tunable elastic reversible (TER) valves that are easy to fabricate, implement and control. In the FER valve the compression of an elastic barrier/patch against a microchamber's outlet prevents the release of liquid. The valve sealing pressure was determined by adjusting the engraving depth of the valve-seat at which the elastic patch was located, this allows to set the sealing pressure during disc fabrication. In the TER valve, the patch compression value and sealing pressure is controlled by the penetration depth of a plastic screw into the valve-seat. The ER valves prevent liquid flow until the centrifugal force overcomes their sealing pressure. Moreover, at a constant spin speed, turning the screw of a TER valve reduces its sealing pressure and opens the valve. Therefore, the TER valve allows for controlling of the liquid transfer volume at various spin speeds. The FER and TER valves' behavior is mathematically described and equations for the prediction of their operation under centrifugal forces are provided. As a point-of-care (POC) application of ER valves, we have developed a microfluidic disc with a series of TER valves and peptide microarrays for automated multiplexed detection of five different proteins from a single serum sample.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links