STUDY DESIGN: Experimental.
SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.
METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.
RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded = .003; Ploaded
METHODS: High-frequency ultrasound (HFU) images of 30 wounds were acquired in a controlled environment on post-debridement days 7, 14, 21, and 28. Meaningful features portraying changes in structure and intensity of echoes during healing were extracted from the images, their relevance and discriminatory power being verified by analysis of variance. Relative analysis of tissue healing was conducted by developing a features-based healing function, optimised using the pattern-search method. Its performance was investigated through leave-one-out cross-validation technique and reconfirmed using principal component analysis.
RESULTS: The constructed healing function could depict tissue changes during healing with 87.8% accuracy. The first principal component derived from the extracted features demonstrated similar pattern to the constructed healing function, accounting for 86.3% of the data variance.
CONCLUSION: The developed wound analysis technique could be a viable tool in quantitative assessment of diabetic foot ulcers during healing.
MATERIALS AND METHODS: Sciatic nerve gap of 15 mm was created in six adult female Sprague-Dawley rats and implanted with PLGA seeded with OECs. The nerve regeneration was assessed electrophysiologically at 2, 4 and 6 weeks following implantation. Histopathological examination, scanning electron microscopic (SEM) examination and immunohistochemical analysis were performed at the end of the study.
RESULTS: Nerve conduction studies revealed a significant improvement of nerve conduction velocities whereby the mean nerve conduction velocity increases from 4.2 0.4 m/s at week 2 to 27.3 5.7 m/s at week 6 post-implantation (P < 0.0001). Histological analysis revealed presence of spindle-shaped cells. Immunohistochemical analysis further demonstrated the expression of S100 protein in both cell nucleus and the cytoplasm in these cells, hence confirming their Schwann-cell-like property. Under SEM, these cells were found to be actively secreting extracellular matrix.
CONCLUSION: Tissue-engineered PLGA conduit seeded with OECs provided a permissive environment to facilitate nerve regeneration in a small animal model.