Displaying all 5 publications

Abstract:
Sort:
  1. Mohamed Saat A, Johan MR
    ScientificWorldJournal, 2014;2014:439839.
    PMID: 25506069 DOI: 10.1155/2014/439839
    Partially phosphorylated polyvinyl alcohol (PPVA) with aluminum phosphate (ALPO4) composites was synthesized by solution casting technique to produce (PPVA)(100-y) - (ALPO4)(y) (y = 0, 1, and 2). The surface structure and thermal properties of the films were characterized using Fourier transform infrared (FTIR) spectroscopy and thermogravimetric analysis (TGA). The results showed that the films have higher thermal stability with strong bonding between PPVA and ALPO4.
  2. Hassan R, Abd Aziz A, Md Ralib AR, Saat A
    Malays J Med Sci, 2011 Jan;18(1):60-7.
    PMID: 22135575 MyJurnal
    The spleen is one of the organs most frequently injured in blunt abdominal trauma. Computed tomography (CT) scanning can accurately detect splenic injury and is currently the imaging modality of choice in assessing clinically stable patients with blunt abdominal trauma. The CT features of spleen injury include lacerations, subcapsular or parenchymal haematomas, active haemorrhage, and vascular injuries. We present a pictorial review of the spectrum of CT findings for blunt splenic injuries. This article will be a useful reference for radiologists and surgeons as CT scan is widely used for the assessment of splenic injuries and contributes to the current trend towards nonsurgical management of this injury.
  3. Radhiana H, Azian AA, Mubarak MY, Saat A, Mohd Amran AR, Jamalludin AR
    Med J Malaysia, 2012 Jun;67(3):316-22.
    PMID: 23082425 MyJurnal
    Multislice computed tomography (MSCT) is the imaging modality of choice in assessing clinically stable patients with blunt abdominal trauma. This study assessed the role of MSCT in the detection of intra abdominal injury caused by blunt trauma in our centre within a two-year-period (2008-2009). A total of 151 patients had MSCT abdomen for blunt abdominal trauma within this study period. Positive scan were seen in 126 patients (83.4%). Out of these positive scans, liver, spleen and renal injuries were seen in 42.1% (n = 53), 34.9% (n = 44) and 30.0% (n = 34) of cases respectively. Laparotomies were performed in 45 patients. Out of these 45 laparotomies, 10 patients had surgically significant injuries that were missed on CT scan findings. The injuries were bowel perforation (n = 4), serosal tear of bowel (n = 1), mesenteric injuries with active haemorrhage (n=3), spleen injury (n = 1) and liver injury (n = 1).
  4. Mokhtar AS, Muslimin M, Mat-Saat AY, Ghazali AM, Ismail AK, Abdul-Aziz NM
    Trop Biomed, 2021 Dec 01;38(4):568-577.
    PMID: 35001923 DOI: 10.47665/tb.38.4.100
    We report two confirmed human bite cases by Lactrodectus geometricus , also known as the brown widow spider. These are the first reported bite envenomation incidents by L. geometricus in Malaysia. The incidents occurred in Tawau, Sabah and Paka, Terengganu. Both men were bitten on their ear while putting on motorcycle helmets. The spiders appeared to have nested in the helmets. The dead specimens were collected and sent to the Invertebrate and Vertebrate Neurobiology Laboratory, Department of Parasitology, Universiti Malaya for identification. The species identity was confirmed by DNA barcoding.
  5. Ismail A, Othman NH, Mustapha M, Mohamed Saheed MS, Abdullah Z, Muhammed M, et al.
    Materials (Basel), 2022 Sep 13;15(18).
    PMID: 36143643 DOI: 10.3390/ma15186331
    This article investigated the mechanical performance and corrosion behaviour of a diffusion-bonded A5083 aluminium/A36 mild steel dissimilar joint with a Gallium (Ga) interlayer. The bonding parameters were the bonding temperature (525 and 550 °C), holding time (60 and 120 min) and surface roughness (800 and 1200 grit). Property characterisation was achieved using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray (EDX) analysis, Vickers microhardness tester, Izod impact tester and potentiodynamic polarisation testing. The results revealed that the significance of the bonding parameters was in the order bonding temperature > surface roughness > holding time. Increasing the bonding temperature resulted in an increase in the impact strength and a corresponding reduction in the corrosion rate and microhardness. However, increasing the grit size decreased the microhardness and a corresponding increase in the impact strength and corrosion rate. The impact strength and corrosion rate decreased with the increasing holding time while the microhardness followed a reverse trend. It was also discovered that incorporating the Ga interlayer resulted in a 67.9% improvement in the degradation rate.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links