Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Looi LM
    Med J Malaysia, 2005 Jul;60 Suppl B:144-5.
    PMID: 16108199
    The liver biopsy has a unique place in the investigation of liver disease because the concepts and classification of liver disease are rooted in morphology. Today, the use of the liver biopsy has extended beyond that of diagnosis, to the assessment of disease progression, response to therapy and transplant rejection. To get the best out of the liver biopsy, it is necessary to appreciate the usefulness and limitations of the biopsy specimen. Aspects to consider include: (1) minimizing sampling errors, and appreciating that the changes in the biopsy may not be representative of the primary pathology, (2) good laboratory quality practices to avoid processing artifacts, which may render a biopsy undiagnosable, (3) the appropriate use of special stains and other laboratory techniques, (4) adoption of a systematic and algorithmic approach in the microscopic examination of the biopsy, and (5) good clinicopathological correlation.
    Matched MeSH terms: Biopsy/methods*
  2. Aliaga Ramos J, Pedrosa MS, Yoshida N, Abdul Rani R, Arantes VN
    J Clin Gastroenterol, 2023 Jan 01;57(1):74-81.
    PMID: 33883515 DOI: 10.1097/MCG.0000000000001541
    BACKGROUND: The standard of practice when a superficial lesion was identified during upper GI endoscopy is to take an endoscopic forceps biopsy (EFB) of the lesion. The histopathologic findings then will determine the management plan. Endoscopic submucosal dissection (ESD) enables en-bloc resection for early neoplasms of the gastrointestinal tract and provides an adequate specimen that permits a more reliable histopathologic assessment. The objective of this study was to determine the rate of histopathologic discrepancy between EFB and specimens resected by ESD, and to identify the predisposing risk factors for this discordance.

    MATERIALS AND METHODS: This is a retrospective study, enrolling patients with superficial gastric neoplasms that underwent EFB followed by ESD. We divided cases to concordant or discordant group according to the histopathologic diagnosis of EFB and ESD specimens. We also analyzed the features that may have influenced the occurrence of histopathologic discordance and the association between discordant samples of adenocarcinoma and neoplastic invasion to deeper layers.

    RESULTS: A total of 115 gastric ESD procedures were performed with 84 patients meeting the inclusion criteria. Histopathologic discordance between EFB and ESD specimens were observed in 35.8% of cases (30/84 lesions). The univariant-bivariant analysis and multivariate logistic regression analysis showed that histologic discordance was closely related to the size of the lesions ( P =0.028).

    CONCLUSION: Histopathologic discrepancy between EFB and ESD specimens may occur in approximately one-third of cases, particularly for lesions over 20 mm, which may lead to crucial delays in gastric cancer precise diagnosis and treatment.

    Matched MeSH terms: Biopsy/methods
  3. Zulfiqar MA, Nair S, Lily M, Norizan MA
    Med J Malaysia, 1999 Dec;54(4):471-7.
    PMID: 11072464
    This is a review of the positive biopsy rate of nonpalpable breast lesions detected on mammography. The histology of 130 hookwire excision biopsy from 1990 to 1995 and the cytology of 39 stereotactic fine needle aspiration cytology in 1995 were reviewed. The yearly positive biopsy rate of each procedure was determined. In 1990, the positive biopsy rate for hookwire excision biopsy was 15%, in 1991 20%, in 1992 11%, in 1993 17%, in 1994 33% and in 1995 39%. In 1995, the positive biopsy rate for stereotactic fine needle aspiration cytology was 21%. The positive biopsy rate for hookwire excision biopsy had improved from 15% in 1990 to 39% in 1995.
    Matched MeSH terms: Biopsy/methods
  4. Canivet CM, Zheng MH, Qadri S, Vonghia L, Chuah KH, Costentin C, et al.
    Clin Gastroenterol Hepatol, 2023 Nov;21(12):3097-3106.e10.
    PMID: 37031715 DOI: 10.1016/j.cgh.2023.03.032
    BACKGROUND & AIMS: Drug development in nonalcoholic steatohepatitis (NASH) is hampered by a high screening failure rate that reaches 60% to 80% in therapeutic trials, mainly because of the absence of fibrotic NASH on baseline liver histology. MACK-3, a blood test including 3 biomarkers (aspartate aminotransferase, homeostasis model assessment, and cytokeratin 18), recently was developed for the noninvasive diagnosis of fibrotic NASH. We aimed to validate the diagnostic accuracy of this noninvasive test in an international multicenter study.

    METHODS: A total of 1924 patients with biopsy-proven nonalcoholic fatty liver disease from 10 centers in Asia, Australia, and Europe were included. The blood test MACK-3 was calculated for all patients. FibroScan-aspartate aminotransferase score (FAST), an elastography-based test for fibrotic NASH, also was available in a subset of 655 patients. Fibrotic NASH was defined as the presence of NASH on liver biopsy with a Nonalcoholic Fatty Liver Disease Activity Score of 4 or higher and fibrosis stage of F2 or higher according to the NASH Clinical Research Network scoring system.

    RESULTS: The area under the receiver operating characteristic of MACK-3 for fibrotic NASH was 0.791 (95% CI 0.768-0.814). Sensitivity at the previously published MACK-3 threshold of less than 0.135 was 91% and specificity at a greater than 0.549 threshold was 85%. The MACK-3 area under the receiver operating characteristic was not affected by age, sex, diabetes, or body mass index. MACK-3 and FAST results were well correlated (Spearman correlation coefficient, 0.781; P < .001). Except for an 8% higher rate of patients included in the grey zone, MACK-3 provided similar accuracy to that of FAST. Both tests included 27% of patients in their rule-in zone, with 85% specificity and 35% false positives (screen failure rate).

    CONCLUSIONS: The blood test MACK-3 is an accurate tool to improve patient selection in NASH therapeutic trials.

    Matched MeSH terms: Biopsy/methods
  5. Hashim E, Hong J, Woo YL, Hamdan M, Tan PC
    Obstet Gynecol, 2024 Jul 01;144(1):53-59.
    PMID: 38703361 DOI: 10.1097/AOG.0000000000005597
    OBJECTIVE: To compare insertion failure rates for Pipelle endometrial sampling with a full bladder compared with the standard process (not taking into account bladder status) without cervical manipulation.

    METHODS: A single-masked randomized trial was conducted in a single tertiary care center from July 2021 to January 2022. Two hundred fourteen participants aged 18 years or older who were scheduled for outpatient Pipelle endometrial sampling were randomized: 107 each to having a full bladder (by oral water intake) or standard process (without delayed sampling and bladder status not taken into account). Women with known cervical stenosis, gynecologic malignancy, uterine anomalies, leiomyoma distorting the uterine cavity, acute cervicitis, urge bladder dysfunction, intense anxiety, need for anesthesia or analgesic before the procedure, positive pregnancy test, or previous failed office endometrial sampling were excluded. The primary outcome was the insertion failure rate of endometrial sampling at first attempt. Secondary outcomes were pain during procedure, satisfaction score, analgesia use, procedure duration, and need for cervical manipulation. Factoring in a baseline insertion failure rate of 30.0%, relative risk of 0.45, α of 0.05, 80.0% power, and a dropout rate of 10.0%, we needed 107 participants in each arm.

    RESULTS: The insertion failure rate was significantly lower in the full bladder group compared with standard process: 25 of 107 (23.4%) compared with 45 of 107 (42.1%) (relative risk 0.56, 95% CI, 0.37-0.84; number needed to treat to benefit 6.0, 95% CI, 3.20-15.70). Pain score (median) during the procedure (interquartile range) was 4 (3-6) compared with 5 (3-8) ( P =.004); patient satisfaction score was 8 (7-9) compared with 7 (4-8) ( P

    Matched MeSH terms: Biopsy/methods
  6. Chan K, Ghani DAM, Teoh J, Brodie A, Gan C, Foley C, et al.
    Urol Oncol, 2024 Dec;42(12):421-428.
    PMID: 39299895 DOI: 10.1016/j.urolonc.2024.08.019
    Conventionally, transrectal ultrasound guided prostate biopsy (TRUS-Bx) was the main technique used for the diagnosis of prostate cancer since it was first described in 1989 [1]. However, the PROMIS trial showed that this random, nontargeted approach could miss up to 18% of clinically significant cancer (csPCa) [2]. Furthermore, risk of sepsis post TRUS-Bx can be as high as 2.4% [3]. Understanding the demerits of TR-biopsy have led to the introduction of transperineal prostate biopsy (TP-Bx). The incorporation of mpMRI revolutionized prostate cancer diagnostics, allowing visualization of areas likely to harbor csPCa whilst permitting some men to avoid an immediate biopsy. Furthermore, the advent of prostate specific membrane antigen-positron emission tomography (PSMA-PET) is highly promising, because of its role in primary diagnosis of prostate cancer and its higher diagnostic accuracy over conventional imaging in detecting nodal and metastatic lesions. Our narrative review provides an overview on prostate biopsy techniques and an update on prostate imaging, with particular focus on PSMA-PET.
    Matched MeSH terms: Image-Guided Biopsy/methods
  7. Waran V, Chandran H, Devaraj P, Ravindran K, Rathinam AK, Balakrishnan YK, et al.
    J Neurol Surg A Cent Eur Neurosurg, 2014 Nov;75(6):422-6.
    PMID: 23955263 DOI: 10.1055/s-0033-1345091
    The universal probe is a tool devised to allow navigation-directed biopsies and drainage procedures to be performed in a simple manner using a single hardware and software.
    Matched MeSH terms: Biopsy/methods
  8. Cheong SK, Lim YC
    Malays J Pathol, 1990 Jun;12(1):51-6.
    PMID: 1708844
    The routine study of bone marrow trephine biopsies involves fixation, decalcification, paraffin-embedment, sectioning and staining. However, this process creates artifacts, produces shrinkage of tissue, consumes time and can result in sections of unsatisfactory cytological quality. It also renders the tissue unsuitable for enzyme-histochemical and immunohistochemical analyses. Frozen section of bone marrow without decalcification was evaluated as an alternative method for the study of bone marrow. This method was found to give sections with comparable cytological quality to that of paraffin-embedment, yielded sections for interpretation within 24 hours, and allowed enzyme-histochemical and immunohistochemical analyses to be applied successfully.
    Matched MeSH terms: Biopsy/methods*
  9. Jain SK
    Med J Malaysia, 1982 Mar;37(1):88-9.
    PMID: 7121356
    The role of multiple pleural biopsies in malignant pleural effusion to achieve better diagnostic yield was evaluated. The specific diagnosis was established in 43.8 percent (14/32) of cases on first biopsy, and improved to 93.8 percent (30/32) of cases by three biopsies. The contribution of multiple biopsies was stressed.
    Matched MeSH terms: Biopsy/methods*
  10. Tham JH, Looi LM, Ghazali R
    Malays J Pathol, 2022 Dec;44(3):469-475.
    PMID: 36591714
    INTRODUCTION: Patients who are suspected of having prostate cancer from screening tests require a tissue biopsy to confirm the presence of cancer. This study aims to compare the cost and cancer detection rate of two different biopsy protocols: 6-core transrectal (TR) approach, and transperineal (TP) saturation biopsy.

    METHODS: In this descriptive, retrospective study, we selected all prostate biopsies received by the diagnostic pathology department of a tertiary hospital in Malaysia in the year 2020, from adult patients for analysis. Data on demographics, specimen preparation processes, and final histopathological diagnosis was extracted from the Laboratory Information System (LIS). The cost incurred for each biopsy diagnosed as cancer was calculated with the cost prices referenced from laboratory documentation. Statistical analysis was performed using SPSS, version 28.

    RESULTS: The total cost for detection of cancer using TR biopsy ranged from RM11.22 - RM271.02 with mean of RM47.53. The standard deviation, s is RM43.45. For TP biopsies, the total cost ranged from RM112.20 - RM349.56 with mean of RM160.85, standard deviation of RM80.37. TR biopsies had a detection rate of 43.2%, while TP biopsies had a 24.2% cancer detection rate. There is a 3.38-fold increase in costs between TR and TP biopsy.

    CONCLUSION: The results show a 3.38-fold increase in costs and a reduction in cancer detection rate when comparing TR and TP biopsy. The reason for the reduced detection rate is unascertained in this study.

    Matched MeSH terms: Biopsy/methods
  11. Chong SE, Chang F, Chuah KH, Sthaneshwar P, Nik Mustapha NR, Mahadeva S, et al.
    Ann Hepatol, 2023;28(2):100888.
    PMID: 36586588 DOI: 10.1016/j.aohep.2022.100888
    INTRODUCTION AND OBJECTIVES: The Hepamet fibrosis score was introduced for the diagnosis of advanced liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). To date, external validation is limited, and its utility in combination with liver stiffness measurement (LSM) has not been explored.

    MATERIAL AND METHODS: This is a cross-sectional study on NAFLD patients who had a liver biopsy and LSM on the same day. The diagnostic performance of the Hepamet fibrosis score was evaluated using the area under the receiver operating characteristic curve (AUROC).

    RESULTS: The data for 196 patients were analyzed (mean age 50 ± 11 years old, 50% men, 56.6% Malay, 27.6% Chinese, 15.8% Indian, 67.9% NASH, 15.8% advanced liver fibrosis). The AUROC of Hepamet fibrosis score for the diagnosis of advanced liver fibrosis was 0.85 (95% CI, 0.80 - 0.91). Using the <0.12 and ≥0.47 cut-offs from the original study, the sensitivity, specificity, positive predictive value, negative predictive value, the proportion of indeterminate results and misclassification rate were 81.8%, 91.8%, 47.4%, 98.2%, 32.1% and 6.1%, respectively. Using LSM <10 kPa and ≥15 kPa for the diagnosis of absence and presence of advanced liver fibrosis, respectively, in patients with Hepamet fibrosis score ≥0.47 (i.e., the two-step approach) reduced indeterminate results and misclassification to 16.1% and 3.6%, respectively.

    CONCLUSIONS: We found the Hepamet fibrosis score to have good diagnostic accuracy in a population that was largely unrepresented in earlier work and demonstrated its utility in a two-step approach with LSM for the diagnosis of advanced liver fibrosis.

    Matched MeSH terms: Biopsy/methods
  12. Angsuwatcharakon P, Kulpatcharapong S, Moon JH, Ramchandani M, Lau J, Isayama H, et al.
    HPB (Oxford), 2022 Jan;24(1):17-29.
    PMID: 34172378 DOI: 10.1016/j.hpb.2021.05.005
    BACKGROUND: Indeterminate strictures pose a therapeutic dilemma. In recent years, cholangioscopy has evolved and the availability of cholangioscopy has increased. However, the position of cholangioscopy in the diagnostic algorithm to diagnose malignancy have not been well established. We aim to develop a consensus statement regarding the clinical role of cholangioscopy in the diagnosis of indeterminate biliary strictures.

    METHODS: The international experts reviewed the evidence and modified the statements using a three-step modified Delphi method. Each statement achieves consensus when it has at least 80% agreement.

    RESULTS: Nine final statements were formulated. An indeterminate biliary stricture is defined as that of uncertain etiology under imaging or tissue diagnosis. When available, cholangioscopic assessment and guided biopsy during the first round of ERCP may reduce the need to perform multiple procedures. Cholangioscopy are helpful in diagnosing malignant biliary strictures by both direct visualization and targeted biopsy. The absence of disease progression for at least 6 months is supportive of non-malignant etiology. Direct per-oral cholangioscopy provides the largest accessory channel, better image definition, with image enhancement but is technically demanding. Image enhancement during cholangioscopy may increase the diagnostic sensitivity of visual impression of malignant biliary strictures. Cholangioscopic imaging characteristics including tumor vessels, papillary projection, nodular or polypoid mass, and infiltrative lesions are highly suggestive for neoplastic/malignant biliary disease. The risk of cholangioscopy related cholangitis is higher than in standard ERCP, necessitating prophylactic antibiotics and ensuring adequate biliary drainage. Per-oral cholangioscopy may not be the modality of choice in the evaluation of distal biliary strictures due to inherent technical difficulties.

    CONCLUSION: Evidence supports that cholangioscopy has an adjunct role to abdominal imaging and ERCP tissue acquisition in order to evaluate and diagnose indeterminate biliary strictures.

    Matched MeSH terms: Biopsy/methods
  13. Bal PK, Nah SA, Wan Mohamad Noor WMR, Md Nor MT, Singaravel S, Tan WS, et al.
    Malays J Pathol, 2023 Dec;45(3):457-462.
    PMID: 38155386
    Hirschsprung's Disease (HD) is a congenital disorder causing severe constipation in infants and children. Suction rectal biopsy (SRB) is the preferred technique for obtaining tissue samples for histopathological evaluation. In low-resource settings like Malaysia, cost-effective diagnostic approaches are necessary, making single sample SRB valuable. This study evaluates the diagnostic accuracy and sufficiency of a single macroscopically adequate sample in suction rectal biopsies for the histopathological confirmation of HD. We conducted a retrospective study of children who underwent suction rectal biopsies for the diagnosis of HD at Hospital Raja Perempuan Zainab II (HRPZII), Kota Bharu, Kelantan. A total of 68 patients were included in the study. The inadequacy rate for bedside SRB was 14%, comparable to current literature. Our study found no statistically significant association between sample inadequacy and gestational age, gender, birth weight, or weight at biopsy. Complication rates were 0%, consistent with literature reports. Calretinin staining, an additional technique, was performed in 23 biopsy episodes, with a 4.3% inadequacy rate, compared to 20% in specimens not subjected to calretinin staining. The cost of SRB almost doubled with each additional sample taken, significant in low-resource environments. In conclusion, single sample SRBs can be adequately diagnostic and cost-effective in low-resource settings, providing valuable insights for healthcare facilities in Malaysia and other developing countries. The use of adjunctive techniques such as calretinin staining may improve diagnostic accuracy while maintaining cost-effectiveness. Further prospective studies with larger sample sizes are needed to validate these findings.
    Matched MeSH terms: Biopsy/methods
  14. Bognár A, Borkhanuddin MH, Nagase S, Sellyei B
    PeerJ, 2024;12:e18288.
    PMID: 39553726 DOI: 10.7717/peerj.18288
    Ectoparasites cause serious problems during the aquaculture production of food fishes. In this study, we set out to develop and test protocols for maintenance and sampling European catfish (Silurus glanis L., 1758) stocks infected with a gill monogenean, Thaparocleidus vistulensis (Siwak 1932) Lim 1996. When we compared the feasibility of two cohabitation-based parasite culture systems (i.e., static vs. flow-through), we found that the life cycle of T. vistulensis was completed in both habitats. In our experience, static tank systems with regular water exchange allowed better daily quality control of the parasite culture than continuous flow-through systems. We investigated the microhabitat preference of T. vistulensis on the gills of infected European catfish. A balanced distribution on the two lateral gill sets and a decreasing trend in parasite numbers from anterior gill holobranches towards the posterior ones was observed. Using these results, we developed a minimally invasive sampling protocol to estimate the parasite load of individuals. The biopsy aimed at four sectors (#6, #7, #10, and #11) situated within the distal and middle zones of the first holobranch on the left side, encompassing both rows of filaments. Biopsy-based estimates of parasite loads were validated by comparing them to full parasite counts of the same individuals and showed statistically significant correlations. Our biopsy-based method is designed to identify experimental animals with similar parasite loads and create groups of hosts with comparable burdens. This setup is expected to generate reduced between-group differences for expensive experiments (e.g., high throughput transcriptomic or epigenetic studies). We propose that the biopsy-based pre-sorting procedure should be considered in similar experiments with other cultured fish species and their gill monogeneans following a thorough fine-tuning of the experimental conditions.
    Matched MeSH terms: Biopsy/methods
  15. Tham TM, Iyengar KR, Taib NA, Yip CH
    Asian Pac J Cancer Prev, 2009 Jan-Mar;10(1):155-8.
    PMID: 19469645
    BACKGROUND: The ideal method for diagnosis of breast cancer is debatable.
    METHODS: The methods of diagnosis of 436 new cases of breast adenocarcinoma presenting from Jan 2005 till Dec 2006 at the University Malaya Medical Centre (UMMC) were examined in this study.
    RESULTS: A total of 388 cases presented to the breast unit in UMMC primarily and 48 cases were diagnosed in non-breast units in other hospitals and referred for management. Fine needle aspiration cytology (FNAC) was the commonest mode of initial diagnosis in 278 cases followed by core needle biopsy and surgical excision. In UMMC, FNAC was the commonest initial method (68.3%) compared to cases diagnosed outside UMMC, where 37.5% of cases were diagnosed by excision. Tumours less than 2cm were more likely to be diagnosed by excision biopsy.
    CONCLUSION: The biopsy method used to confirm the diagnosis is influenced by where the patient first presents, and by the size of the tumour.
    Matched MeSH terms: Biopsy/methods*
  16. Chan SH, Ng C, Looi LM
    ANZ J Surg, 2008 Sep;78(9):775-9.
    PMID: 18844907 DOI: 10.1111/j.1445-2197.2008.04648.x
    Isosulfan blue is not available for clinical use in Malaysia. This study describes the use of methylene blue as an alternative to isosulfan blue in colorectal sentinel node mapping.
    Matched MeSH terms: Sentinel Lymph Node Biopsy/methods*
  17. Hisham AN, Harjit K, Fatimah O, Yun SI
    Med J Malaysia, 2004 Aug;59(3):402-5.
    PMID: 15727388
    Prebiopsy localization of impalpable breast lesions (IBL) assures removal of suspicious mammographically detected lesions. Specimen radiograph of the excised specimen is mandatory to confirm complete excision. The aim of this study was to audit our series of percutaneous hookwire localization and to determine the positive biopsy rate of the mammographically detected impalpable breast lesion in our center. Thirty-eight patients with suspicious IBL underwent excision biopsy under mammographic localization in our unit from late February 1998 to May 2003. The excised specimen is immobilized and compressed within the Transpec device. This device incorporates a reference grid visible in the specimen radiograph. Hence, the target lesion marked in the reference grid of the specimen radiograph will allow precise examination and exact localization of the suspicious lesion by the pathologist. The positive biopsy rate for malignant lesion was 26.3%, the majority fall in the range of 40-59 age group. Thirty-two (84.2%) of the patients had clustered micro-calcifications, 4 (10.5%) had impalpable mass lesions and in 2 (5.3%) spiculated lesions were seen on the preoperative mammogram. Mammographic feature of clustered micro-calcification accounts for all the malignant lesions in our series. Utilization of Transpec device has shown to be practical, reliable and cost effective in the management of IBL. Nonetheless, it should be emphasized that optimal specimen radiography and pathological correlation requires close cooperation between radiologist, surgeon and pathologist.
    Matched MeSH terms: Biopsy/methods*
  18. Yii RSL, Lim J, Sothilingam S, Yeoh WS, Fadzli AN, Ong TA, et al.
    Asian J Surg, 2020 Jan;43(1):87-94.
    PMID: 30962017 DOI: 10.1016/j.asjsur.2019.02.014
    OBJECTIVES: To identify the associated factors determining prostate cancer detection using transrectal ultrasound (TRUS)-guided prostate biopsy, within a multi-ethnic Malaysian population with prostate specific antigen (PSA) between 4.0 and 10.0 ng/ml.

    METHODS: Study subjects included men with initial PSA between 4.0 and 10.0 ng/ml that have undergone 12-core TRUS-guided prostate biopsy between 2009 and 2016. The prostate cancer detection rate was calculated, while potential factors associated with detection were investigated via univariable and multivariable analysis.

    RESULTS: A total of 617 men from a multi-ethnic background encompassing Chinese (63.5%), Malay (23.1%) and Indian (13.3%) were studied. The overall cancer detection rate was 14.3% (88/617), which included cancers detected at biopsy 1 (first biopsy), biopsy 2 (second biopsy with previous negative biopsy) and biopsy ≥ 3 (third or more biopsies with prior negative biopsies). Indian men displayed higher detection rate (23.2%) and increased risk of prostate cancer development (OR 1.85, 95% CI 1.03-3.32, p 

    Matched MeSH terms: Image-Guided Biopsy/methods
  19. Othman H, Abu Yamin AH, Md Isa N, Bahadzor B, Syed Zakaria SZ
    Malays J Pathol, 2020 Aug;42(2):209-214.
    PMID: 32860373
    INTRODUCTION: Prostate health index (PHI) has been shown to have better diagnostic accuracy in predicting prostate cancer (PCa) in men with total prostate-specific antigen (PSA) levels between 4-10ng/ml. However, little is known of its value in men with elevated PSA beyond this range. This study aimed to evaluate the diagnostic performance of PHI in Malaysian men with elevated PSA values ≤ 20ng/ml.

    MATERIALS AND METHODS: From March 2015 to August 2016, all men consecutively undergoing transrectal ultrasound (TRUS)-guided prostate biopsy with total PSA values ≤ 20ng/ ml were recruited. Blood samples were taken immediately before undergoing prostate biopsy. The performance of total PSA, %fPSA, %p2PSA and PHI in determining the presence of PCa on prostate biopsy were compared.

    RESULTS: PCa was diagnosed in 25 of 84 patients (29.7%). %p2PSA and PHI values were significantly higher (p<0.05) in patients with PCa than those without PCa. The areas under the receiver operating characteristic curves for total PSA, %fPSA, %p2PSA and PHI were 0.558, 0.560, 0.734 and 0.746, respectively. At 90% sensitivity, the specificity of PHI (42.4%) was five times better than total PSA (8.5%) and two times better than %fPSA (20.3%). By utilising PHI cut-off >22.52, 27 of 84 (32.1%) patients could have avoided undergoing biopsy.

    CONCLUSION: Findings of our study support the potential clinical effectiveness of PHI in predicting PCa in a wider concentration range of total PSA up to 20ng/ml.

    Matched MeSH terms: Biopsy/methods
  20. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Chow TK, et al.
    Nephrology (Carlton), 2021 Jan;26(1):38-45.
    PMID: 33058334 DOI: 10.1111/nep.13805
    AIM: Renal biopsy is the gold standard for the histological characterization of chronic kidney disease (CKD), of which renal fibrosis is a dominant component, affecting its stiffness. The aim of this study was to investigate the correlation between kidney stiffness obtained by shear wave elastography (SWE) and renal histological fibrosis.

    METHODS: Shear wave elastography assessments were performed in 75 CKD patients who underwent renal biopsy. The SWE-derived estimates of the tissue Young's modulus (YM), given as kilopascals (kPa), were measured. YM was correlated to patients' renal histological scores, broadly categorized into glomerular, tubulointerstitial and vascular scores.

    RESULTS: Young's modulus correlates significantly with tubulointerstitial score (ρ = 0.442, P 

    Matched MeSH terms: Biopsy/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links