  1. Lim YC, Cheong SK, Joyce JA, Ainoon O, Jeyasekeran V, Menaka N
    Malays J Pathol, 1990 Jun;12(1):43-9.
    PMID: 2090889
    The Contraves Autolyzer 801 is a 20 parameter cell counter that operates on the principle of impedance. This evaluation study found that the within-batch precision for 5 of its parameters--WBC, RBC, Hb, Hct and Plt--had coefficients of variation below 5%, while the counts for red cell parameters were reproducible for up to 3 days. The analyser exhibited good linearity for all the parameters. When compared with 2 other counters--the Coulter S-Plus and the Coulter M350, some degree of proportional and constant bias due to unsuitable calibration were detected in the WBC, Hct and Plt parameters. Otherwise it showed generally good correlation in all the parameters and also with the manual PCV method. Carry over was negligible in the red cell parameters. The Contraves Autolyzer 801 is easy to operate and readily accepted by operators.
    Matched MeSH terms: Blood Cell Count/instrumentation*
  2. Ag Z, Cheong SK
    Malays J Pathol, 1995 Dec;17(2):77-81.
    PMID: 8935130
    A system for computerising full blood picture reporting developed in-house using dBASE IV on IBM-compatible microcomputers in a local area network environment is described. The software package has a user-friendly interface which consists of a horizontal main menu bar with associated pull-down submenus. The package captures data directly from an automatic blood cell counter and provides options to modify or delete records, search for records, print interim, final or cumulative reports, record differential counts with an emulator, facilitate house-keeping activities which include backing-up databases and repairing corrupted indices. The implementation of this system has helped to improve the efficiency of reporting full blood picture in the haematology laboratory.
    Matched MeSH terms: Blood Cell Count/instrumentation*
  3. Kumar D, Kapoor S, Gowda A, Gupta D, Mittal H, Sood S
    PLoS One, 2026;21(11):e0353640.
    PMID: 42976121 DOI: 10.1371/journal.pone.0353640
    BACKGROUND: Non-invasive hemoglobin measurement offers a painless and rapid alternative to conventional blood-based testing. The Vivaray Hb pro is a handheld photoplethysmography-based device designed for point-of-care hemoglobin assessment without blood sampling. We evaluated the clinical performance of the Vivaray Hb pro by comparing device-generated hemoglobin values with those obtained from a calibrated laboratory blood cell counter.

    METHODS: In this cross-sectional, non-randomized clinical performance study, participants aged ≥8 years were prospectively recruited. Hemoglobin was measured non-invasively using the Vivaray Hb pro and compared with venous blood samples analyzed on a calibrated Coulter counter. Agreement between methods was assessed using Bland-Altman analysis, including regression-based evaluation for proportional bias. Mean difference, mean absolute error (MAE) and proportions of measurements within tolerance limits were also calculated. Complete paired measurements were available for 763 individuals.

    RESULTS: Bland-Altman analysis returned a mean difference of -0.40 g/dL. The bias was hemoglobin-dependent, being higher than the true value at low hemoglobin levels and underestimation at higher levels. Regression-based analysis showed proportional bias (β1 = -0.178), indicating decreasing difference with increasing hemoglobin concentration. The MAE was 1.5 g/dL but was lower (1.2) in the clinically predominant ranges of 8.1-13 g/dL.

    CONCLUSION: The Vivaray Hb pro can function as a useful non-invsive screening and point-of-care assessment device for measuring hemoglobin, particularly in settings where rapid, painless and repeatable measurements are desirable.

    Matched MeSH terms: Blood Cell Count/instrumentation