Displaying publications 1 - 20 of 49 in total

Abstract:
Sort:
  1. Lim YC, Cheong SK, Joyce JA, Ainoon O, Jeyasekeran V, Menaka N
    Malays J Pathol, 1990 Jun;12(1):43-9.
    PMID: 2090889
    The Contraves Autolyzer 801 is a 20 parameter cell counter that operates on the principle of impedance. This evaluation study found that the within-batch precision for 5 of its parameters--WBC, RBC, Hb, Hct and Plt--had coefficients of variation below 5%, while the counts for red cell parameters were reproducible for up to 3 days. The analyser exhibited good linearity for all the parameters. When compared with 2 other counters--the Coulter S-Plus and the Coulter M350, some degree of proportional and constant bias due to unsuitable calibration were detected in the WBC, Hct and Plt parameters. Otherwise it showed generally good correlation in all the parameters and also with the manual PCV method. Carry over was negligible in the red cell parameters. The Contraves Autolyzer 801 is easy to operate and readily accepted by operators.
    Matched MeSH terms: Blood Cell Count/instrumentation*
  2. Ag Z, Cheong SK
    Malays J Pathol, 1995 Dec;17(2):77-81.
    PMID: 8935130
    A system for computerising full blood picture reporting developed in-house using dBASE IV on IBM-compatible microcomputers in a local area network environment is described. The software package has a user-friendly interface which consists of a horizontal main menu bar with associated pull-down submenus. The package captures data directly from an automatic blood cell counter and provides options to modify or delete records, search for records, print interim, final or cumulative reports, record differential counts with an emulator, facilitate house-keeping activities which include backing-up databases and repairing corrupted indices. The implementation of this system has helped to improve the efficiency of reporting full blood picture in the haematology laboratory.
    Matched MeSH terms: Blood Cell Count/instrumentation*; Blood Cell Count/methods*
  3. Sakthiswary R, Syahrul Sazliyana S, Mohd Shahrir MS, Shahril NS, Hussein H
    EXCLI J, 2012;11:142-9.
    PMID: 27385955
    Tumor necrosis factor alpha (TNFα) is a multifunctional cytokine which plays a pivotal role in the pathogenesis of rheumatoid arthritis (RA). Apart from its well recognized proinflammatory properties, it is known to interfere with lipid metabolism and erythropoiesis. We evaluated the effects of adalimumab on hematologic, lipid and inflammatory parameters using data from patients on adalimumab 40 mg fortnightly from 2 centers in Malaysia. Mean changes in laboratory values from baseline to Weeks 4, 12 and 24 were compared using paired T test and Wilcoxon signed-rank test. We studied 18 patients with RA who were on adalimumab 40 mg fortnightly. The inflammatory markers i.e. erythrocyte sedimentation rate and C reactive protein showed significant changes as early as at week 4 compared to baseline with p values of 0.003 and 0.005, respectively. From a baseline of high disease activity with a mean Disease Activity Score using 28 joint counts (DAS 28) of 5.3, there was a steady improvement in the disease activity and remission was achieved at week 24 with a DAS 28 of 2.4. The hemoglobin level improved at week 12 (p=0.013) and this was sustained till week 24. As opposed to previous studies, the LDL level significantly decreased at week 12 (p=0.015) and this change persisted till week 24 (p=0.001). The total cholesterol showed a similar pattern as the LDL. The pharmacodynamics of adalimumab therapy in rheumatoid arthritis extend beyond the joints with favorable effects on haemoglobin and lipid profile.

    Study site: Putrajaya Hospital and Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Blood Cell Count
  4. Omar-Ahmad UD, Lopez CG, Ramanathan K, Keat TC
    Dent J Malaysia Singapore, 1968 Feb;8(1):43-53.
    PMID: 5248557
    Matched MeSH terms: Blood Cell Count
  5. Rusmawati, I., Asma Hanim, H., Naznin, M., Salman, M.S., Norlelawati, A.T.
    MyJurnal
    Introduction: Dengue is one of the commonest infections in Malaysia and it is a notifi able disease. Even
    though the diagnosis of classical dengue fever and dengue haemorrhagic fever can be recognized clinically, the diagnosis remains a challenge in areas where it could not be differentiated with other febrile illnesses. The aim of this study was to focus on the specifi c and consistent morphological features observed in blood fi lms of dengue infection. Materials and Methods: In all 400 cases of dengue infection serologically diagnosed in the Tengku Ampuan Afzan Hospital (HTAA) during May to October 2007, only a total of 27 cases had blood fi lms examined, and thus were included in this study. These blood fi lms were re-examined by two pathologists from HTAA. The full blood count parameters were also retrieved and studied. Results: We consistently found typical reactive lymphocytes [n= 23 (85%)] and thrombocytopenia [n=21, (77.8%)] in the cases. However, leucopenia was present only in 9 cases (33%). Conclusion: The presence of typical reactive lymphocyte is a consistent fi nding in dengue fever and thus could have a signifi cant role in supporting the diagnosis of dengue infection.
    Matched MeSH terms: Blood Cell Count
  6. Hughes W
    Malayan Medical Journal, 1935;10:111-2.
    Matched MeSH terms: Blood Cell Count
  7. Piyarathna IE, Thabet AM, Ucgul M, Lemckert C, Lim YY, Tang ZS
    Sensors (Basel), 2023 Jun 01;23(11).
    PMID: 37299984 DOI: 10.3390/s23115257
    Piezoelectric energy harvesting systems have been drawing the attention of the research community over recent years due to their potential for recharging/replacing batteries embedded in low-power-consuming smart electronic devices and wireless sensor networks. However, conventional linear piezoelectric energy harvesters (PEH) are often not a viable solution in such advanced practices, as they suffer from a narrow operating bandwidth, having a single resonance peak present in the frequency spectrum and very low voltage generation, which limits their ability to function as a standalone energy harvester. Generally, the most common PEH is the conventional cantilever beam harvester (CBH) attached with a piezoelectric patch and a proof mass. This study investigated a novel multimode harvester design named the arc-shaped branch beam harvester (ASBBH), which combined the concepts of the curved beam and branch beam to improve the energy-harvesting capability of PEH in ultra-low-frequency applications, in particular, human motion. The key objectives of the study were to broaden the operating bandwidth and enhance the harvester's effectiveness in terms of voltage and power generation. The ASBBH was first studied using the finite element method (FEM) to understand the operating bandwidth of the harvester. Then, the ASBBH was experimentally assessed using a mechanical shaker and real-life human motion as excitation sources. It was found that ASBBH achieved six natural frequencies within the ultra-low frequency range (<10 Hz), in comparison with only one natural frequency achieved by CBH within the same frequency range. The proposed design significantly broadened the operating bandwidth, favouring ultra-low-frequency-based human motion applications. In addition, the proposed harvester achieved an average output power of 427 μW at its first resonance frequency under 0.5 g acceleration. The overall results of the study demonstrated that the ASBBH design can achieve a broader operating bandwidth and significantly higher effectiveness, in comparison with CBH.
    Matched MeSH terms: Blood Cell Count
  8. Sabariah, M.N., Leong, C.F., Cheong, S.K.
    MyJurnal
    Peripheral blood (PB) CD34+ cells enumeration is currently the most reliable method to guide the timing of stem cell harvest. However, its usage is restricted by being technically challenging, costly, and time-consuming. Immature reticulocyte fraction (IRF) determination, which is simpler and cheaper and has a faster turn-around time, has been proposed for a similar purpose. The purpose of this study is to evaluate the value of IRF in guiding stem cell harvest and examine the correlation between IRF and PB CD34+ cells count. Daily pre-harvest tests, i.e. PB CD34+ cells and IRF from 21 patients scheduled for autologous PBSC transplant were assessed. Stem cells harvests were commenced when the PB CD34+ cell count were more than 10 cell/ul. A total of 205 pre-harvest tests were analysed. Following stem cell mobilisations, both the IRF and PB CD 34+ cell counts rose with a variable pattern. In this study, we observed that the IRF peaks preceded the PB CD34+ count by 2 days. On the day of stem cell harvest, all the peak IRF values were >0.3. The PB CD34+ cell counts correlated with the harvested stem cell yield, whereby r2 = 0.77, p < 0.021. In autologous stem cell mobilisation, we believe that IRF is a useful screening tool to predict the rise of the PB CD34+ cell counts as it is a simple, fast and less costly. An IRF of > 0.3 may be used as a cut-off value for the initiation of PB CD34+ quantification prior to stem cell harvest.
    Matched MeSH terms: Blood Cell Count
  9. Manohar, A., Azhar, M.Z.
    MyJurnal
    We report a case of factitious dermatitis in a 17 year female student who presented with recurrent pain .swelling and subcutaneous crepitations of the forearm. A thorough investigation was done. Full blood count, erythrocyte sedimentation rate was normal. Plain radiographs revealed the presence of subcutaneous emphysema. MRI showed similar findings and revealed normal muscles. Colonoscopy and OGDS were normal. except for a small polyp at the gastro-esophageal junction. Based on the clinical findings and lack of correlation with the investigations a diagnosis of factitious subcutaneous emphysema was made.
    Matched MeSH terms: Blood Cell Count
  10. Mu’izuddin M. Senin, Imad M. Al-Ani, Mohamed Imad A.M. Mahmud, Naznin Muhammad, Hanif M. Kasmuri
    MyJurnal
    Introduction: Virgin coconut oil (VCO) is known for its health and therapeutic benefits. However, the immunomodulatory effects of VCO have not been extensively investigated. Objective: The present study was devoted to examining the effects of VCO on cyclophosphamide (CY)-induced toxicity of lymphoid tissues. Methods: Thirty healthy male Wistar rats were sorted into 5 groups of 6 animals. The first control (NC) group was given distilled water via gavage at 5 ml/kg once daily. The second (CY) group received CY orally at 10 mg/kg/day for 4 weeks. Rats in the other three groups (CV5, CV10, and CV15) were given 10 mg/kg/day CY for 4 weeks, 5 m/kg/day, 10 ml/kg/day and 15 ml/kg/day VCO for 6 weeks, respectively. Rats were sacrificed at the end of 6th week; blood sample from the animals was collected for full blood count and biochemical analysis. The thymus and spleen of each animal was processed for histological examination. Results: The thymus and spleen showed marked reduction in lymphoid cellularity following daily administration of CY. The thymus also showed a marked reduction in the size of the medulla, and the white pulp areas of spleen had reduction in the follicle number and size. Supplementation with 10 ml/kg and 15 ml/kg VCO showed evidence of restoration of both the thymus and splenic lymphoid architecture. The total white cell counts, absolute lymphocyte counts and plasma globulin levels of the VCO groups were significantly increased compared to CY group. Conclusion: VCO displayed potential protective effects on CYinduced histological changes in lymphoid tissues.
    Matched MeSH terms: Blood Cell Count
  11. Alomari YM, Sheikh Abdullah SN, Zaharatul Azma R, Omar K
    Comput Math Methods Med, 2014;2014:979302.
    PMID: 24803955 DOI: 10.1155/2014/979302
    Segmentation and counting of blood cells are considered as an important step that helps to extract features to diagnose some specific diseases like malaria or leukemia. The manual counting of white blood cells (WBCs) and red blood cells (RBCs) in microscopic images is an extremely tedious, time consuming, and inaccurate process. Automatic analysis will allow hematologist experts to perform faster and more accurately. The proposed method uses an iterative structured circle detection algorithm for the segmentation and counting of WBCs and RBCs. The separation of WBCs from RBCs was achieved by thresholding, and specific preprocessing steps were developed for each cell type. Counting was performed for each image using the proposed method based on modified circle detection, which automatically counted the cells. Several modifications were made to the basic (RCD) algorithm to solve the initialization problem, detecting irregular circles (cells), selecting the optimal circle from the candidate circles, determining the number of iterations in a fully dynamic way to enhance algorithm detection, and running time. The validation method used to determine segmentation accuracy was a quantitative analysis that included Precision, Recall, and F-measurement tests. The average accuracy of the proposed method was 95.3% for RBCs and 98.4% for WBCs.
    Matched MeSH terms: Blood Cell Count*
  12. Chin SF, Cheong SK, Lim YC, Ton SH
    Malays J Pathol, 1993 Jun;15(1):49-52.
    PMID: 8277790
    The distribution of immunoregulatory cells in the peripheral blood of an individual has now been established as an important tool in helping the management of several diseases. It is necessary to set the normal ranges of these cells for the laboratory. We have undertaken in this study to establish the reference ranges for normal Malaysian adults. We found that the mean percentages of T cells, B cells, T Helper cells (CD4), T suppressor cells (CD8), NK cells and the ratio of CD4/CD8 were 70.91%, 11.38%, 38.15%, 37.76%, 17.45%, and 1.00 respectively. There was no significant difference between the sexes. In certain parameters, there was significant differences between Malay, Chinese and Indians. The Chinese and Indians were significantly different in the distribution of B cells and in the CD4/CD8 ratio. In the case of CD4 and NK cells, the Indians were different from the other two groups.
    Matched MeSH terms: Blood Cell Count*
  13. Ismail AH, Jaafar MS
    Appl Radiat Isot, 2011 Mar;69(3):559-66.
    PMID: 21208807 DOI: 10.1016/j.apradiso.2010.11.004
    Complete blood counts were analyzed for 30 samples of human blood with radiation dose rate ranging between 10 and 41 μSv/h using a Radium-226 source with different time of exposure. A new technique involving a nuclear track detector type CR-39(CR-39 NTDs) was used to estimate the alpha particle density incident on the blood samples. The results show that the ranges of alpha particle in blood samples and on the surface of CR-39NTDs vary exponentially with energy of alpha particles. This depends on the restricted energy loss and target density. Changes in the blood components due to irradiation occurred for different durations of irradiation, and the duration of irradiation that influenced the blood samples in this study was 6 min. The change in red blood cell (RBC) was negligible, so it is less affected than other blood components. In addition, most changes in the blood contents began at a low radiation dose (10.38-13.41 μSv/h). For the doses 13.41-21.77 μSv/h, platelet (PLT) counts increased rapidly and adversely with the RBC and white blood cell (WBC) due to chromosomal aberration. Besides, rapid PLT count reduction rapidly at high dose (42.1 μSvh) causes thrombocytopenia; in contrast, WBC increased, which is an indication of cancer caused due to increase in alpha particle dose. Generally, our results are in agreement with the essentials of blood content and the principles of biological radiation interaction.
    Matched MeSH terms: Blood Cell Count
  14. Roshan TM, Rosline H, Ahmed SA, Rapiaah M, Wan Zaidah A, Khattak MN
    Int J Lab Hematol, 2009 Oct;31(5):505-12.
    PMID: 18498389 DOI: 10.1111/j.1751-553X.2008.01068.x
    Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
    Matched MeSH terms: Blood Cell Count
  15. Musawi MS, Jafar MS, Al-Gailani BT, Ahmed NM, Suhaimi FM, Suardi N
    Photomed Laser Surg, 2016 May;34(5):211-4.
    PMID: 26966989 DOI: 10.1089/pho.2015.4043
    OBJECTIVE: This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) (λ = 405 nm) laser were observed.

    BACKGROUND DATA: The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm(2). Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer.

    RESULTS: Significant decrease in RBC volume (p cell shrinkage.

    Matched MeSH terms: Blood Cell Count
  16. Chong YH, Ho GS
    Med J Malaysia, 1973 Dec;28(2):113-4.
    PMID: 4276226
    Matched MeSH terms: Blood Cell Count
  17. Lim, L. N., Yu, K. S., Chua, S. M., George, E., Lai, M. I., Wong, L., et al.
    MyJurnal
    Introduction: Filipino β°-deletion is predominant among the β-thalassaemia patients in the indigenous population of Sabah, Malaysia particularly among the Kadazandusun. Individuals who co-inherit with α- and β-thalassaemia will demonstrate milder clinical symptoms with modified complete blood count (CBC) and Hb subtype parameters. HBS1L-MYB variants act as one of the key regulator of haematopoiesis and erythropoiesis and display strong association
    with variation of HbF levels. Therefore, this study aims to evaluate the association between genetic variants in HBS1L-MYB with Hb subtypes level among Filipino β°-deletion carriers co-inherited with -α3.7 deletion. Methods: Filipino β°-deletion and -α3.7 deletion were identified using gap-polymerase chain reaction (PCR). A total of 34 subjects found with coinheritance of Filipino β°-deletion and -α3.7 deletion were subjected for HBS1L-MYB intergenic polymorphisms (HMIP) analysis. Hb subtypes level were quantified using BioRad Variant II Hb analyser. Genotyping of HBS1L-MYB variants rs9399137 and rs11759553 was done using own designed tetra primer ARMS-PCR. Results: The minor allele frequencies (MAF) of the two HMIP is found more than 0.05 (rs11759553, MAF=0.18 and rs9399137, MAF=0.15), indicating the significance of these variants among the study subjects. Significant difference was found between HbF level and HBS1L-MYB variant rs11759553 with p-value less than 0.05 (p=0.001). Subjects with homozygous genotype for rs11759553 (T/T) was found with higher HbF, followed by heterozygous (A/T) and wild type (A/A). rs11759553 and rs9399137 was found did not influence the level of HbA and HbA2. HMIP of rs11759553 and rs9399137 are found significant among Filipino β°-deletion carriers co-inherited with -α3.7deletion with its high minor allelic frequency and high HbF level. Strong association with HbF level was demonstrated when
    coinheritance of rs11759553. Conclusion: This study demonstrates that there are significant associations between certain genetic variants in HBS1L-MYB with Hb subtypes level among Filipino β°-deletion carriers co-inherited with -α3.7 deletion.
    Matched MeSH terms: Blood Cell Count
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links