Displaying all 7 publications

Abstract:
Sort:
  1. Yap JF, Wai YZ, Ng QX, Lim LT
    J Med Case Rep, 2019 May 06;13(1):131.
    PMID: 31056080 DOI: 10.1186/s13256-019-2064-1
    BACKGROUND: This is a case report of an iatrogenic intralenticular broken steroid (Ozurdex™) implant in a patient with uveitis. There are only a few case reports on broken Ozurdex™ implants in the vitreous cavity, with none of them involving the crystalline lens. A few authors have described the accidental injection of an Ozurdex™ implant into the crystalline lens, but all of the implants remained in one piece in the lens and none of them were broken. We report an unusual case of an Ozurdex™ implant which was injected inadvertently into the crystalline lens, resulting in a broken Ozurdex™ implant with an entry and exit wound through the posterior capsule of the lens.

    CASE PRESENTATION: An ophthalmic trainee performed an Ozurdex™ intravitreal injection into a 48-year-old Asian man's right eye under aseptic conditions. This patient was then followed up for further management. On day 7 post-procedure, a slit lamp examination revealed that the Ozurdex™ implant was injected into the intralenticular structure of his right eye and had fractured into two pieces. The posterior capsule of the right lens was breached, with one half of the Ozurdex™ implant stuck at the entry and the other stuck at the exit wound of the posterior capsule. This patient underwent right eye cataract extraction and repositioning of the fractured implant; he made an uneventful recovery.

    CONCLUSIONS: Ophthalmologists should be aware of the potential risk of injecting an Ozurdex™ implant into an anatomical structure other than the vitreous cavity. Adequate training and careful administration of the Ozurdex™ implant are necessary to avoid such a complication, which fortunately is rare.

    Matched MeSH terms: Drug Implants/adverse effects*
  2. Wong TW, Nurulaini H
    Drug Dev Ind Pharm, 2012 Dec;38(12):1417-27.
    PMID: 22309449 DOI: 10.3109/03639045.2011.653364
    Alginate-chitosan pellets prepared by extrusion-spheronization technique exhibited fast drug dissolution.
    Matched MeSH terms: Drug Implants/chemistry
  3. Khor HG, Lott PW, Wan Ab Kadir AJ, Singh S, Iqbal T
    J Ocul Pharmacol Ther, 2024;40(6):342-360.
    PMID: 37676992 DOI: 10.1089/jop.2023.0012
    Purpose: Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. Methods: Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. Results: A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. Conclusions: A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the "Trendelenburg position, external pressure with head positioning" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).
    Matched MeSH terms: Drug Implants*
  4. Sheshala R, Hong GC, Yee WP, Meka VS, Thakur RRS
    Drug Deliv Transl Res, 2019 04;9(2):534-542.
    PMID: 29484530 DOI: 10.1007/s13346-018-0491-y
    The objectives of this study were to develop biodegradable poly-lactic-co-glycolic acid (PLGA) based injectable phase inversion in situ forming system for sustained delivery of triamcinolone acetonide (TA) and to conduct physicochemical characterisation including in vitro drug release of the prepared formulations. TA (at 0.5%, 1% and 2.5% w/w loading) was dissolved in N-methyl-2-pyrrolidone (NMP) solvent and then incorporated 30% w/w PLGA (50/50 and 75/25) polymer to prepare homogenous injectable solution. The formulations were evaluated for rheological behaviour using rheometer, syringeability by texture analyser, water uptake and rate of implant formation by optical coherence tomography (OCT) microscope. Phase inversion in situ forming formulations were injected into PBS pH 7.3 to form an implant and release samples were collected and analysed for drug content using a HPLC method. All formulations exhibited good syringeability and rheological properties (viscosity: 0.19-3.06 Pa.s) by showing shear thinning behaviour which enable them to remain as free-flowing solution for ease administration. The results from OCT microscope demonstrated that thickness of the implants were increased with the increase in time and the rate of implant formation indicated the fast phase inversion. The drug release from implants was sustained over a period of 42 days. The research findings demonstrated that PLGA/NMP-based phase inversion in situ forming implants can improve compliance in patient's suffering from ocular diseases by sustaining the drug release for a prolonged period of time and thereby reducing the frequency of ocular injections.
    Matched MeSH terms: Drug Implants
  5. Yellepeddi VK, Sheshala R, McMillan H, Gujral C, Jones D, Raghu Raj Singh T
    Drug Discov Today, 2015 Jul;20(7):884-9.
    PMID: 25668579 DOI: 10.1016/j.drudis.2015.01.013
    Punctal plugs (PPs) are miniature medical implants that were initially developed for the treatment of dry eyes. Since their introduction in 1975, many PPs made from different materials and designs have been developed. PPs, albeit generally successful, suffer from drawbacks such as epiphora and suppurative canaliculitis. To overcome these issues intelligent designs of PPs were proposed (e.g. SmartPLUG™ and Form Fit™). PPs are also gaining interest among pharmaceutical scientists for sustaining drug delivery to the eye. This review aims to provide an overview of PPs for dry eye treatment and drug delivery to treat a range of ocular diseases. It also discusses current challenges in using PPs for ocular diseases.
    Matched MeSH terms: Drug Implants
  6. Molloy GJ, Sweeney LA, Byrne M, Hughes CM, Ingham R, Morgan K, et al.
    BMJ Open, 2015 Aug 12;5(8):e007794.
    PMID: 26270944 DOI: 10.1136/bmjopen-2015-007794
    OBJECTIVE: Many forms of contraception are available on prescription only for example, the oral contraceptive pill (OCP) and long-acting reversible contraceptives (LARCs). In this analysis we aim to identify key determinants of prescription contraceptive use.
    DESIGN: Cross-sectional population survey. Data on sociodemographic indices, concerns about the OCP and perceived barriers to access were collected.
    SETTING: Data set constructed from a representative population-based telephone survey of community dwelling adults in the Republic of Ireland (RoI)
    PARTICIPANTS: 1515 women aged between 18 and 45 years
    MAIN OUTCOME MEASURE: Self-reported user of the OCP or LARCs (intrauterine contraception, contraceptive injections or subdermal contraceptive implants) in the previous 12 months.
    RESULTS: For at least some of the previous year, 35% had used the OCP and 14% had used LARCs, while 3% had used two or more of these methods. OCP users were significantly younger, more likely to be unmarried and had higher income than non-users. Overall, 68% agreed with the statement 'that taking a break from long-term use of the contraceptive pill is a good idea' and 37% agreed with the statement that 'the OCP has dangerous side effects' and this was the strongest predictor variable of non-use of the OCP. Intrauterine contraception users were significantly older, more likely to be married and had lower income than non-users. Injections or subdermal contraceptive implant users were significantly younger, less likely to be married, had lower income and were less likely to agree that taking a break from long-term use of the pill is a good idea than non-users.
    CONCLUSIONS: Prescription contraceptive use is sociodemographically patterned, with LARCs in particular being associated with lower incomes in the RoI. Concerns about the safety of the OCP remain prevalent and are important and modifiable determinants of contraceptive-related behaviour.
    Matched MeSH terms: Drug Implants
  7. Periayah MH, Halim AS, Mat Saad AZ, Yaacob NS, Hussein AR, Abdul Karim F, et al.
    Thromb Res, 2015 Sep;136(3):625-33.
    PMID: 26254703 DOI: 10.1016/j.thromres.2015.07.027
    Von Willebrand disease (vWD) is the second least common hemostatic disorder in Malaysia, and it has a low prevalence. This study examined the underlying platelet thrombogenicity cascades in the presence of different formulations of chitosan-derivatives in vWD patients. This paper aimed to determine the significant influence of chitosan biomaterial in stimulating the platelet thrombogenicity cascades that involve the von Willebrand factor, Factor 8, Thromboxane A2, P2Y12 and Glycoprotein IIb/IIIa in vWD.
    Matched MeSH terms: Drug Implants
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links