  1. Yahaya ML, Zakaria ND, Noordin R, Abdul Razak K
    Biotechnol Appl Biochem, 2021 Oct;68(5):1095-1106.
    PMID: 32935878 DOI: 10.1002/bab.2029
    Salmonella and Shigella genera are common pathogens that contaminate foods and beverages. Lateral flow assays (LFA) are commonly used to detect these pathogens. However, most of the developed LFAs are for single detection. Simultaneous detection of pathogens is required to reduce cost and time. In this work, 40 nm gold nanoparticles (AuNPs) were synthesized using the seeding growth method as labeling agent. The AuNPs were characterized and conjugated with mouse anti-Gram negative endotoxin antibody. The nitrocellulose membrane HF135 was immobilized with anti-mouse IgG antibody as a control line and two separate test lines with either anti-Shigella or anti-Salmonella antibody, respectively. Color intensity of test lines was observed for positive samples. A milk sample was used as proof of concept to mimic actual contamination. The limit of detection of the LFA was 3.0 × 106 CFU/mL for multiplex detection of Shigella flexneri and Salmonella Typhi and for both single detections. The result was comparable with the enzyme-linked immunosorbent assay (ELISA) analysis. The produced LFA could differentiate between Shigella flexneri, Shigella boydii, Salmonella Enteritidis, and Salmonella Typhi. The developed LFA was able to identify Shigella flexneri and Salmonella Typhi with good sensitivity in milk samples, thus, beneficial to ensure the safety of food before entering the market.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation
  2. Thiha A, Ibrahim F
    Sensors (Basel), 2015;15(5):11431-41.
    PMID: 25993517 DOI: 10.3390/s150511431
    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation*
  3. Ponniah J, Muhammad K, Abdullah S, Ganapathy KK, bt Sheikh Abdul Hamid N
    PMID: 15691160
    Three ELISA test kits, the Randox ELISA beta-agonist test kit, Euro-Diagnostica test kit, and Ridascreen beta-agonist test kit, were evaluated for screening of meat and liver for beta-agonist residues in fortified and field-incurred samples. It was found that the Randox beta-agonist test kit was more suitable as a screening tool due to its accuracy, ease of use, and lower cost. The tests were able to detect beta-agonist residues at the minimum level of detection, as claimed by the suppliers. The performance of the method as assessed through recovery rates of beta-agonists in fortified samples was satisfactory with a low coefficient of variation (1-3%). Repeatability, as measured through the coefficient of correlation was also satisfactory. For field-incurred positive samples, the test kit showed a sensitivity of 100% and a low rate of false positives for goat and cow tissues. However, a high rate of apparent false positives was obtained for tissues of swine.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation*
  4. Hosseini S, Azari P, Farahmand E, Gan SN, Rothan HA, Yusof R, et al.
    Biosens Bioelectron, 2015 Jul 15;69:257-64.
    PMID: 25765434 DOI: 10.1016/j.bios.2015.02.034
    Electrospun polyhydroxybutyrate (PHB) fibers were dip-coated by polymethyl methacrylate-co-methacrylic acid, poly(MMA-co-MAA), which was synthesized in different molar ratios of the monomers via free-radical polymerization. Fabricated platfrom was employed for immobilization of the dengue antibody and subsequent detection of dengue enveloped virus in enzyme-linked immunosorbent assay (ELISA). There is a major advantage for combination of electrospun fibers and copolymers. Fiber structre of electrospun PHB provides large specific surface area available for biomolecular interaction. In addition, polymer coated parts of the platform inherited the premanent presence of surface carboxyl (-COOH) groups from MAA segments of the copolymer which can be effectively used for covalent and physical protein immobilization. By tuning the concentration of MAA monomers in polymerization reaction the concentration of surface -COOH groups can be carefully controlled. Therefore two different techniques have been used for immobilization of the dengue antibody aimed for dengue detection: physical attachment of dengue antibodies to the surface and covalent immobilization of antibodies through carbodiimide chemistry. In that perspective, several different characterization techniques were employed to investigate the new polymeric fiber platform such as scanning electron microscopy (SEM), atomic force microscopy (AFM), water contact angle (WCA) measurement and UV-vis titration. Regardless of the immobilization techniques, substantially higher signal intensity was recorded from developed platform in comparison to the conventional ELISA assay.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation