CASE DETAILS: In the present case, the fracture was suspected during the process of removal. The tip of the catheter was notably missing, and an emergency chest radiograph confirmed our diagnosis of a retained fracture of central venous catheter. The retained portion was removed by the interventional radiologist using an endovascular loop snare and delivered through a femoral vein venotomy performed by the surgeon.
CONCLUSION: Endovascular approach to retrieval of retained fractured catheters has helped tremendously to reduce associated morbidity and the need for major surgery. The role of surgery has become limited to instances of failed endovascular retrieval and in remote geographical locations devoid of such specialty.
CASE REPORT: A case of ureterovaginal fistula associated with a neglected vaginal foreign body. The patient was complaining of a foul-smelling vaginal discharge and lower abdominal pain. On vaginal examination, a hard and large foreign body was found. Examination under anesthesia was performed, and an aerosol cap was removed from her vagina. The patient developed urinary incontinence after removal of the foreign body. Subsequent work-up demonstrated the presence of a right ureterovaginal fistula. The patient underwent an abdominal ureteroneocystostomy. At one year follow up, the patient had fully recovered.
CONCLUSION: Ureterovaginal fistula following neglected vaginal foreign body is a serious condition. Early diagnosis, treatment of infection and proper surgical management can improve the outcome and decrease complications.