Displaying all 9 publications

Abstract:
Sort:
  1. Chuah KH, Ramasami N, Mahendran HA, Shanmuganathan G, Koleth GG, Voon K, et al.
    J Gastroenterol Hepatol, 2024 Mar;39(3):431-445.
    PMID: 38087846 DOI: 10.1111/jgh.16403
    Disorders of esophagogastric junction (EGJ) outflow, including achalasia and EGJ outflow obstruction, are motility disorders characterized by inadequate relaxation of lower esophageal sphincter with or without impaired esophageal peristalsis. Current guidelines are technical and less practical in the Asia-Pacific region, and there are still massive challenges in timely diagnosis and managing these disorders effectively. Therefore, a Malaysian joint societies' task force has developed a consensus on disorders of EGJ outflow based on the latest evidence, while taking into consideration the practical relevance of local and regional context and resources. Twenty-one statements were established after a series of meetings and extensive review of literatures. The Delphi method was used in the consensus voting process. This consensus focuses on the definition, diagnostic investigations, the aims of treatment outcome, non-surgical or surgical treatment options, management of treatment failure or relapse, and the management of complications. This consensus advocates the use of high-resolution esophageal manometry for diagnosis of disorders of EGJ outflow. Myotomy, via either endoscopy or laparoscopy, is the preferred treatment option, while pneumatic dilatation can serve as a secondary option. Evaluation and management of complications including post-procedural reflux and cancer surveillance are recommended.
    Matched MeSH terms: Manometry/methods
  2. Shanmuganathan G, Ritz MA, Holloway RH, Di Matteo AC, Omari TI
    J Gastroenterol Hepatol, 2000 Dec;15(12):1362-9.
    PMID: 11197044
    BACKGROUND AND AIMS: Perfused miniature manometric assemblies with lumina of 0.4-0.5 mm i.d. have been developed. Reduced luminal size offers the advantages of reduced assembly bulk and increased assembly complexity with greater numbers of lumina and lower manometric infusion volumes because of a slower perfusion rate. This study investigated the recording fidelity of miniature manometric assemblies in the measurement of esophageal peristalsis.

    METHODS: Four miniature manometric assemblies, each containing manometric lumina of either 0.4 or 0.5 mm i.d., were evaluated at 100 and 180 cm lengths. The fidelity of miniature manometric luminal recordings were evaluated in vivo during esophageal peristalsis by using a simultaneous comparison with the standard lumina and an intraluminal strain gauge.

    RESULTS: During esophageal peristalsis, miniature manometric lumina recorded the peak amplitude of pressure waves, with an accuracy at perfusion rates of 0.04 mL/min (0.4 mm, i.d.) and 0.15 mL/min (0.5 mm, i.d.).

    CONCLUSION: Miniature manometric assemblies of lengths that are practical for use in humans are suitable for recording esophageal peristalsis.

    Matched MeSH terms: Manometry/methods*
  3. Tan WS, Md Hasan Z, Sanmugam A, Singaravel S, Abdullah MY, Nah SA
    J Pediatr Surg, 2023 Feb;58(2):241-245.
    PMID: 36384936 DOI: 10.1016/j.jpedsurg.2022.10.031
    INTRODUCTION: Anorectal manometry may be useful to objectively evaluate anorectal function following definitive pullthrough for Hirschsprung Disease (HD) but there is little published data. Our study aims to investigate anorectal manometry findings and their association with bowel function.

    METHODOLOGY: This was a prospective observational study. Convenience sampling method was used to recruit all HD patients who had definitive pullthrough from January 2019 to December2020 in our institution. High-resolution anorectal manometry (HRAM) was used to record anal resting pressure (ARP), length of high-pressure zone (HPZ), and presence/absence of recto-anal inhibitory reflex (RAIR). The Paediatric Incontinence/Constipation Scoring System (PICSS) was scored for all participants. PICSS is a validated questionnaire with scores mapped to an age-specific normogram to denote constipation, incontinence, and their combinations. Non-parametric and chi-square tests at significance p<0.05 were conducted to examine the relationship between PICSS categories and manometry findings. Ethical approval was obtained.

    RESULTS: There were 32 participants (30 boys). Median age at participation was 26.5 months (range: 13.8-156). Twenty-four (75%) had transanal pullthrough, 8(25%) underwent Duhamel procedure. PICSS scored 10(31.3%) as normal, 8(25%) as constipation, 10(31.3%) as incontinent, and 4(12.5%) as mixed. RAIR was present in 12 patients (37.5%). HPZ, maximum ARP, mean ARP were comparable across all PICSS groups without statistically significant differences. Presence of RAIR was not significantly associated with any PICSS groups (p = 0.13).

    CONCLUSION: Bowel function does not appear to be significantly associated with HRAM findings after definitive pullthrough for HD, but our study is limited by small sample size. RAIR was present in 37.5% patients after pullthrough.

    LEVEL OF EVIDENCE: Level II.

    Matched MeSH terms: Manometry/methods
  4. Siboni S, Kristo I, Rogers BD, De Bortoli N, Hobson A, Louie B, et al.
    Clin Gastroenterol Hepatol, 2023 Jul;21(7):1761-1770.e1.
    PMID: 36270615 DOI: 10.1016/j.cgh.2022.10.008
    BACKGROUND & AIMS: The straight leg raise (SLR) maneuver during high-resolution manometry (HRM) can assess esophagogastric junction (EGJ) barrier function by measuring changes in intraesophageal pressure (IEP) when intra-abdominal pressure is increased. We aimed to determine whether increased esophageal pressure during SLR predicts pathologic esophageal acid exposure time (AET).

    METHODS: Adult patients with persistent gastroesophageal reflux disease (GERD) symptoms undergoing HRM and pH-impedance or wireless pH study off proton pump inhibitor were prospectively studied between July 2021 and March 2022. After the HRM Chicago 4.0 protocol, patients were requested to elevate 1 leg at 45º for 5 seconds while supine. The SLR maneuver was considered effective when intra-abdominal pressure increased by 50%. IEPs were recorded 5 cm above the lower esophageal sphincter at baseline and during SLR. GERD was defined as AET greater than 6%.

    RESULTS: The SLR was effective in 295 patients (81%), 115 (39%) of whom had an AET greater than 6%. Hiatal hernia (EGJ type 2 or 3) was seen in 135 (46%) patients. Compared with patients with an AET less than 6%, peak IEP during SLR was significantly higher in the GERD group (29.7 vs 13.9 mm Hg; P < .001). Using receiver operating characteristic analysis, an increase of 11 mm Hg of peak IEP from baseline during SLR was the optimal cut-off value to predict an AET greater than 6% (area under the receiver operating characteristic curve, 0.84; sensitivity, 79%; and specificity, 85%), regardless of the presence of hiatal hernia. On multivariable analysis, an IEP pressure increase during the SLR maneuver, EGJ contractile integral, EGJ subtype 2, and EGJ subtype 3, were found to be significant predictors of AET greater than 6% CONCLUSIONS: The SLR maneuver can predict abnormal an AET, thereby increasing the diagnostic value of HRM when GERD is suspected.

    CLINICALTRIALS: gov ID: NCT04813029.

    Matched MeSH terms: Manometry/methods
  5. Chaharborj SS, Amin N
    PLoS One, 2020;15(2):e0228955.
    PMID: 32106248 DOI: 10.1371/journal.pone.0228955
    This paper discusses the optimal control of pressure using the zero-gradient control (ZGC) approach. It is applied for the first time in the study to control the optimal pressure of hydrogen natural gas mixture in an inclined pipeline. The solution to the flow problem is first validated with existing results using the Taylor series approximation, regression analysis and the Runge-Kutta method combined. The optimal pressure is then determined using ZGC where the optimal set points are calculated without having to solve the non-linear system of equations associated with the standard optimization problem. It is shown that the mass ratio is the more effective parameter compared to the initial pressure in controlling the maximum variation of pressure in a gas pipeline.
    Matched MeSH terms: Manometry/methods
  6. Mohd Said MR, Wong Z, Abdul Rani R, Ngiu CS, Raja Ali RA, Lee YY
    J Gastroenterol Hepatol, 2021 May;36(5):1244-1252.
    PMID: 33002243 DOI: 10.1111/jgh.15284
    BACKGROUND AND AIM: Variations in the Chicago 3.0 normative metrics may exist with different postures and with different provocative swallow materials in a healthy Asian population.

    METHOD: Eligible healthy Malay volunteers were invited to undergo the high-resolution esophageal manometry (inSIGHT Ultima, Diversatek Healthcare, Milwaukee, WI, USA). In recumbent and standing positions, test swallows were performed using liquid, viscous, and solid materials. Metrics including integrated relaxation pressure 4 s (IRP-4 s, mmHg), distal contractile integral (DCI, mmHg s cm), distal latency (DL, s), and peristaltic break (PB, cm) were reported in median and 95th percentile.

    RESULTS: Fifty of 57 screened participants were recruited, and 586 saline, 265 viscous, and 261 solid swallows were analyzed. Per-patient wise, in the recumbent position, 95th percentile for IRP-4 s, DCI, DL, and PB were 16.5 mmHg, 2431 mmHg s cm, 8.5 s, and 7.2 cm, respectively. We observed that with each posture, the use of viscous swallows led to changes in DL, but the use of solid swallows led to more changes in the metrics including DCI and length of PB. Compared with a recumbent posture, anupright posture led to lower IRP-4 s and DCI values. Both per-patient analysis and per-swallow analyses yielded almost similar results when comparing the different postures and types of swallows. No major motility disorders were observed in this cohort of asymptomatic population. However, more motility disorders were reported in the upright position.

    CONCLUSIONS: Variations in metrics can be observed in different postures and with different provocative swallow materials in a healthy population. The normative Chicago 3.0 metrics are also determined for the Malay population.

    Matched MeSH terms: Manometry/methods*
  7. Boo HS, Chik I, Ngiu CS, Lim SY, Jarmin R
    Am J Case Rep, 2018 Aug 23;19:998-1003.
    PMID: 30135416 DOI: 10.12659/AJCR.909717
    BACKGROUND The esophagus can be affected by a variety of disorders that may be primary or secondary to another pathologic process, but the resulting symptoms are usually not pathognomonic for a specific problem, making diagnosis and further management somewhat challenging. High resolution impedance manometry (HRiM) has established itself as a valuable tool in evaluating esophageal motility disorder. HRiM is superior in comparison with conventional water perfused manometric recordings in delineating and tracking the movement of functionally defined contractile elements of the esophagus and its sphincters, and in distinguishing the luminal pressurization of spastic esophageal contraction from a trapped bolus. Making these distinctions can help to identify achalasia, distal esophageal spasm, functional obstruction, and subtypes according to the latest Chicago Classification of Esophageal Motility Disorders version 3.0. CASE REPORT We report a case series of 4 patients that presented with dysphagia; and with the ancillary help of the HRiM, we are able to diagnose esophageal motility disorder and evaluate its pathogenetic mechanism. This approach aids in tailoring each management individually and avoiding disastrous mismanagement. CONCLUSIONS From the series of case reports, we believe that HRiM has an important role to play in deciding appropriate management for patients presenting with esophageal motility disorders, and HRiM should be performed before deciding on management.
    Matched MeSH terms: Manometry/methods*
  8. Rogers BD, Rengarajan A, Abrahao L, Bhatia S, Bor S, Carlson DA, et al.
    Neurogastroenterol Motil, 2021 06;33(6):e14009.
    PMID: 33094875 DOI: 10.1111/nmo.14009
    BACKGROUND: Esophagogastric junction contractile integral (EGJ-CI) and EGJ morphology are high-resolution manometry (HRM) metrics that assess EGJ barrier function. Normative data standardized across world regions and HRM manufacturers are limited.

    METHODS: Our aim was to determine normative EGJ metrics in a large international cohort of healthy volunteers undergoing HRM (Medtronic, Laborie, and Diversatek software) acquired from 16 countries in four world regions. EGJ-CI was calculated by the same two investigators using a distal contractile integral-like measurement across the EGJ for three respiratory cycles and corrected for respiration (mm Hg cm), using manufacturer-specific software tools. EGJ morphology was designated according to Chicago Classification v3.0. Median EGJ-CI values were calculated across age, genders, HRM systems, and regions.

    RESULTS: Of 484 studies (28.0 years, 56.2% F, 60.7% Medtronic studies, 26.0% Laborie, and 13.2% Diversatek), EGJ morphology was type 1 in 97.1%. Median EGJ-CI was similar between Medtronic (37.0 mm Hg cm, IQR 23.6-53.7 mm Hg cm) and Diversatek (34.9 mm Hg cm, IQR 22.1-56.1 mm Hg cm, P = 0.87), but was significantly higher using Laborie equipment (56.5 mm Hg cm, IQR 35.0-75.3 mm Hg cm, P 

    Matched MeSH terms: Manometry/methods*
  9. Wong ML, Sandham A, Ang PK, Wong DC, Tan WC, Huggare J
    Eur J Orthod, 2005 Feb;27(1):91-7.
    PMID: 15743868
    The aim of this study was to measure craniofacial morphology and nasal respiratory resistance (NRR) in Malay, Indian and Chinese subjects with obstructive sleep apnoea (OSA). The sample consisted of 34 male subjects, 27-52 years of age (Malay n = 11, which included five mild and six moderate-severe OSA; Indian n = 11, which included six mild and five moderate-severe OSA; and Chinese n = 12, which included six mild and six moderate-severe OSA) diagnosed using overnight polysomnography. After use of a decongestant, NRR was recorded using anterior and posterior rhinomanometry. Standardized lateral cephalometric radiographs were used to record linear and angular dimensions. Malay subjects with moderate-severe OSA had a shorter maxillary (sp-pm) and mandibular (gn-go) length when compared with a mild OSA reference sample (P < 0.05). The hyoid bone was located more caudally in the Chinese moderate-severe subjects (hy-NL, hy-ML)(P < 0.05), and may be a useful diagnostic indicator for severity in this racial group. No pattern of differences for NRR was seen between the moderate-severe and mild OSA subjects. The consistently lower values for nasopharyngeal resistance in all the moderate-severe subjects when compared with the mild group may indicate that some compensation at this level of the airway had taken place. Strong positive correlations between craniocervical angulation (NL/OPT) and total airway resistance and the turbulent component of flow (k(2)) suggest that head posture is sensitive to fluctuations in airway resistance (P < 0.01).
    Matched MeSH terms: Manometry/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links