Displaying publications 1 - 20 of 55 in total

Abstract:
Sort:
  1. Chan KY
    Med J Malaya, 1969 Dec;24(2):138-44.
    PMID: 4244139
    Matched MeSH terms: Respiratory Function Tests*
  2. Noor Hassim I
    Family Physician, 1991;3:11-13.
    Matched MeSH terms: Respiratory Function Tests
  3. Johari HM, Zainudin HA, Knight VF, Lumley SA, Subramanium AS, Caszo BA, et al.
    J Sports Med Phys Fitness, 2017 Apr;57(4):396-401.
    PMID: 27045742 DOI: 10.23736/S0022-4707.16.06292-7
    BACKGROUND: Anthropometric and lung function characteristics of triathletes are important for the implementation of individual specific training and recovery recommendations. However, limited data are available for these parameters in triathletes. Hence, the aim of this study was to characterize and examine the gender differences of lung function and anthropometry parameters in competitive triathletes from Malaysia.

    METHODS: Body composition assessment and lung function tests were performed on sixteen competitive triathletes (nine male and seven female). The subject's body composition profile including muscle mass (kg), fat free mass (kg), and percent body fat was measured using a bio-impedance segmental body composition analyzer. Forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were measured by Quark PFT2 spirometer.

    RESULTS: The anthropometric measurements revealed that male triathletes were significantly taller than female triathletes and had significantly more protein and skeletal muscle mass. The female triathletes, however, had significantly higher percent body fat. Male triathletes had statistically significant higher FVC and FEV1 than female triathletes. Both the male and female triathletes showed a positive correlation between height, fat free mass and the lung function markers FVC and FEV1. This association was not seen with Body Mass Index (BMI) in female triathletes.

    CONCLUSIONS: The data from our study shows that anthropometric parameters are directly linked to lung function of a triathlete. We also found the relationship between BMI and lung function to be gender specific in triathletes and is dependent on the body protein and fat content. Hence, body composition characterization is essential and provides valuable information for developing individual specific training modules.
    Matched MeSH terms: Respiratory Function Tests*
  4. Mohan V, Aziz KB, Kamaruddin K, Leonard JH, Das S, Jagannathan MG
    EXCLI J, 2012;11:284-90.
    PMID: 27418905
    The use of manual stretching procedures has become more prevalent in cardiorespiratory physiotherapy to improve pulmonary functions. However, limited evidence exists regarding evaluation of their effectiveness. The study aimed to determine the impact of Intercostal (IC) stretch in improving the dynamic pulmonary function parameters (Forced Expiratory Volume in the first second (FEV1), Forced Vital Capacity (FVC) and FEV1/FVC % and respiratory rate among healthy adults. Thirty healthy male subjects were recruited based on inclusion and exclusion criteria. Subjects were assigned to the experimental group and the control group through random sampling method. In the experimental group, subjects underwent IC stretch for ten breaths on the inspiratory phase of the respiratory cycle with breathing control exercises in semi recumbent position, while in the control group, breathing control exercises alone were performed in the semi recumbent position. The results of the study showed, FEV1/FVC % in the experimental group significantly improved with P=0.017 (p<0.05) than the control group, which means IC stretch increased lung volume and lead to improved lung function. This study suggested the IC stretching with breathing control may be more effective in improving dynamic lung parameters especially FEV1/FVC % than breathing control alone.
    Matched MeSH terms: Respiratory Function Tests
  5. Zhu Z, Pan X, Zhong F, Tian J, Ong MLY
    Nurs Open, 2023 May;10(5):2819-2830.
    PMID: 36575646 DOI: 10.1002/nop2.1572
    AIM: To understand Baduanjin rehabilitation therapy in mild COVID-19 patients.

    DESIGN: A narrative review.

    METHODS: A literature search for COVID-19 and Baduanjin treatments was conducted on Chinese and English electronic databases: China National Knowledge Infrastructure, Wanfang Data, Embase, PubMed, Scopus, Science Direct, Ebscohost, SPORTDiscus and ProQuest.

    RESULTS: Twelve studies on the Baduanjin rehabilitation for COVID-19 patients have been included. We acknowledged the considerable published research and current clinical practice using Baduanjin for COVID-19 treatment in the following areas: anxiety, depression, insomnia, lung function rehabilitation, immunity and activity endurance.

    CONCLUSION: The use of Baduanjin as adjuvant therapy for COVID-19 patients' rehabilitation is still limited, therefore, more clinical studies are needed to confirm its efficacy.

    Matched MeSH terms: Respiratory Function Tests
  6. Mo S, Gupta SS, Stroud A, Strazdins E, Hamizan AW, Rimmer J, et al.
    Laryngoscope, 2021 02;131(2):260-267.
    PMID: 32386248 DOI: 10.1002/lary.28682
    OBJECTIVES: Nasal peak inspiratory flow (NPIF) is a practical and affordable tool that measures maximum inspiratory flow rate through both nostrils. Although NPIF values for healthy controls and patients appear to differ considerably, a generally expected value for populations with and without nasal obstruction has yet to be established. The aim of this systematic review and meta-analysis was to determine the mean NPIF value in populations with and without nasal obstruction.

    METHODS: Medline (1946-) and Embase (1947-) were searched until July 1, 2017. A search strategy was used to identify studies that reported NPIF values for defined healthy or disease states. All studies providing original data were included. The study population was defined as having either normal nasal breathing or nasal obstruction. A meta-analysis of the mean data was presented in forest plots, and data were presented as mean (95% confidence interval [CI]).

    RESULTS: The search yielded 1,526 studies, of which 29 were included. The included studies involved 1,634 subjects with normal nasal breathing and 817 subjects with nasal obstruction. The mean NPIF value for populations with normal nasal breathing was 138.4 (95% CI: 127.9-148.8) L/min. The mean value for populations with nasal obstruction was 97.5 (95% CI: 86.1-108.8) L/min.

    CONCLUSIONS: Current evidence confirms a difference between mean NPIF values of populations with and without nasal obstruction. The mean value of subjects with no nasal obstruction is 138.4 L/min, and the mean value of nasally obstructed populations is 97.5 L/min. Prospective studies adopting a standardized procedure are required to further assess normative NPIF values. Laryngoscope, 131:260-267, 2021.

    Matched MeSH terms: Respiratory Function Tests/methods; Respiratory Function Tests/statistics & numerical data*
  7. Lim KH, Liam CK, Wong CMM
    Med J Malaysia, 2000 Jun;55(2):265-7.
    PMID: 19839158
    An asymptomatic subject with radiographic changes due to welders' siderosis is described. This condition has not been well recognized and described in our community. Siderosis of the lung is generally considered to be a benign condition not associated with respiratory symptoms. However, recent reports have associated welding with various disorders of pulmonary function as well as lung cancer. There is a need for future epidemiological studies to better define the risk of long term welding.
    Matched MeSH terms: Respiratory Function Tests
  8. Gan KB, Yahyavi ES, Ismail MS
    Technol Health Care, 2016 Sep 14;24(5):761-8.
    PMID: 27163300 DOI: 10.3233/THC-161161
    BACKGROUND: At the emergency triage center, assessment of the present of the danger signs and measurement of vital signs are measured according to the guidelines. The respiration rate is still posing a challenge to the doctor as it is impractical to use conventional devices. Attaching measurement devices to the patient will induce artificial measurements (self-awareness stress effects) besides being time-consuming. Currently, the medical officers visually count the number of times the chest movement in a minute, sometimes poses cultural challenges especially for female patients.

    OBJECTIVE: The main objective of this paper is to develop a robust algorithm to extract respiration rate using the contactless displacement sensor.

    METHODS: In this study, chest movements were used as an indicative of inspiration and expiration to measure respiratory rate using the contactless displacement sensor. The contactless optical signals were recorded from 32 healthy subjects in four different controlled breathing conditions: rest, coughing, talking and hand movement to obtain the motion artifacts that the patients may have in the emergency department. The Empirical mode decomposition (EMD) algorithm was used to derive continuous RR signal from the contactless optical signal.

    RESULTS: The analysis showed that there is a good correlation (0.9702) with RMSE of 0.33 breaths per minutes between the contact respiration rate and contactless respiration rate using empirical mode decomposition method.

    CONCLUSION: It can be concluded that the empirical mode decomposition method can extract the respiration rate of the contactless optical signal from chest movement.

    Matched MeSH terms: Respiratory Function Tests/instrumentation*
  9. Gnanou J, Caszo B, Mohamad WH, Nawawi H, Yusoff K, Ismail T
    PMID: 22299480
    Several equations have been used to predict lung function standard results for different populations. It is important lung function evaluations use appropriate standards for the study population. The objective of this study was to develop a prediction equation for lung function test results for the Malaysian population. Spirometry was performed among 5,708 subjects and 1,483 healthy, lifetime never smoked subjects (386 males and 1,097 females). Prediction equations were derived for both men and women for FVC and FEV1 results. The equations were validated on new subjects (n = 532, 222 males and 310 females) who met the same inclusion and exclusion criteria as the main cohort. There was a positive correlation between the measured values and the values derived from the new prediction equations (0.62 for FEV1 and between 0.66 and 0.67 for FVC; both p < 0.05) for both men and women with a smaller bias and limit of agreement compared to the published reference equations of ECCS, Knudson, Crapo and NHANES III. The reference equations derived from local spirometry data were more appropriate than generally used equations based on data from previous studies in different population.
    Matched MeSH terms: Respiratory Function Tests*
  10. Deng CT, Azizi BH
    J Asthma, 1996;33(2):125-30.
    PMID: 8609100 DOI: 10.3109/02770909609054541
    Three peak flow meters (PFM), Wright's, Miniwright's II (MPFM), and Pocket, were evaluated in 50 children in a pediatric outpatient clinic. It was found that there was close agreement between the Pocket and the MPFM as shown by an intraclass correlation (rho) of 0.95. Less agreement was noted between the MPFM and the Pocket, respectively, with the Wright's. It was also noted that the coefficient of correlation (r) was not a suitable test for agreement in this study. Both the Pocket and the MPFM also read higher than the Wright's. We conclude that children should be monitored using the same type of peak flow meter.
    Study site: Pediatric clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Respiratory Function Tests/instrumentation*
  11. Chia SE, Wang YT, Chan OY, Poh SC
    Ann Acad Med Singap, 1993 Nov;22(6):878-84.
    PMID: 8129348
    Forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow rate (PEFR), single-breath diffusion capacity measurements (effective alveolar volume (VA), carbon monoxide transfer factor (DLCO) and transfer coefficient (KCO)) were determined in 452 healthy Singaporean adults (277 males and 175 females) aged 20-70 years. The ratio of Chinese, Malay and Indian subjects was 5:2:3 in both sexes. Age, height and weight in the males were all significantly correlated with FEV1, FVC, DLCO, VA and PEFR. However, for females, only age and height were significantly correlated with the studied lung function parameters. Significant ethnic differences were observed for most of the pulmonary functions (except KCO and PEFR) among the Chinese, Malays and Indians for both males and females. The predicted FEV1 and FVC values (specific age and height) for both sexes were highest among the Chinese followed by the Malays than Indians, in that order. Regression equations, with age and height as independent variables, were derived for males and females in each ethnic group to predict normal pulmonary function for the Singapore Chinese, Malay and Indian populations. The predicted values of various pulmonary function measurements obtained from these regression equations for subjects of specified age (30 years) and height (165 cm for men, 155 cm for women) were compared with those reported in other studies. Differences were observed among the different races.
    Matched MeSH terms: Respiratory Function Tests*
  12. Ismail Y, Azmi NN, Zurkurnain Y
    Med J Malaysia, 1993 Jun;48(2):171-4.
    PMID: 8350792
    We conducted a study to measure the peak expiratory flow rate (PEFR), forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) in a group of normal Malay primary school children aged 7 to 12 years. PEFR was measured in 920 children (482 boys and 438 girls) while FVC and FEV1 were measured in 292 of them (168 boys and 124 girls). In agreement with previous studies, we found that PEFR was correlated with age and height of the subjects but FVC and FEV1 were correlated with height only. Prediction equations for all 3 lung function indices for Malay boys and girls were formulated. In comparison with the lung function values from Western and Chinese subjects, the lung function values in our subjects are lower.
    Matched MeSH terms: Respiratory Function Tests*
  13. Redmond DP, Chiew YS, Major V, Chase JG
    Comput Methods Programs Biomed, 2019 Apr;171:67-79.
    PMID: 27697371 DOI: 10.1016/j.cmpb.2016.09.011
    Monitoring of respiratory mechanics is required for guiding patient-specific mechanical ventilation settings in critical care. Many models of respiratory mechanics perform poorly in the presence of variable patient effort. Typical modelling approaches either attempt to mitigate the effect of the patient effort on the airway pressure waveforms, or attempt to capture the size and shape of the patient effort. This work analyses a range of methods to identify respiratory mechanics in volume controlled ventilation modes when there is patient effort. The models are compared using 4 Datasets, each with a sample of 30 breaths before, and 2-3 minutes after sedation has been administered. The sedation will reduce patient efforts, but the underlying pulmonary mechanical properties are unlikely to change during this short time. Model identified parameters from breathing cycles with patient effort are compared to breathing cycles that do not have patient effort. All models have advantages and disadvantages, so model selection may be specific to the respiratory mechanics application. However, in general, the combined method of iterative interpolative pressure reconstruction, and stacking multiple consecutive breaths together has the best performance over the Dataset. The variability of identified elastance when there is patient effort is the lowest with this method, and there is little systematic offset in identified mechanics when sedation is administered.
    Matched MeSH terms: Respiratory Function Tests/standards*
  14. Putri Anis Syahira MJ, Karmegam K, Nur Athirah Diyana MY, Irniza R, Shamsul Bahri MT, Vivien H, et al.
    Work, 2020;66(1):25-29.
    PMID: 32417810 DOI: 10.3233/WOR-203147
    BACKGROUND: Malaysian traffic policemen are constantly exposed to unhealthy air in the outdoor environment, which results in various health problems. This study investigates the relationship of the personal exposure level to PM2.5 and lung functions in traffic policemen in Kuala Lumpur and Johor Bahru.

    METHODS: A pulmonary function test using a spirometer was carried out to measure the lung function of the traffic policemen. The personal exposure level to PM2.5 was measured using a pump with a PVC filter and 5.0μm pore size. A questionnaire requesting the background data, such as age, height, and weight, was also used for testing lung function abnormalities.

    RESULTS: The PM2.5 personal exposure level was found to be significantly related to lung function (predicted FEV1 and predicted FVC) at p-value function deterioration among traffic policemen. These baseline data can serve as a reference for the top management of traffic police to aid in the development of occupational safety and health guidelines for police officers, as the traffic police are not covered by the Occupational Safety and Health Act (OSHA, Act 514 1994).

    Matched MeSH terms: Respiratory Function Tests*
  15. Harun SN, Wainwright C, Klein K, Hennig S
    Paediatr Respir Rev, 2016 Sep;20:55-66.
    PMID: 27259460 DOI: 10.1016/j.prrv.2016.03.002
    A systematic review was performed (i) to describe the reported overall rate of progression of CF lung disease quantified as FEV1%predicted decline with age, (ii) to summarise identified influencing risk factors and (iii) to review methods used to analyse CF lung disease progression data. A search of publications providing FEV1%predicted values over age was conducted in PUBMED and EMBASE. Baseline and rate of FEV1%predicted decline were summarised overall and by identified risk factors. Thirty-nine studies were included and reported variable linear rates of lung function decline in patients with CF. The overall weighted mean FEV1%predicted over age was graphically summarised and showed a nonlinear, time-variant decline of lung function. Compared to their peers, Pseudomonas aeruginosa infection and pancreatic insufficiency were most commonly associated with lower baseline and more rapid FEV1%predicted declines respectively. Considering nonlinear models and drop-out in lung disease progression, analysis is lacking and more studies are warranted.
    Matched MeSH terms: Respiratory Function Tests
  16. Noor H, Yap CL, Zolkepli O, Faridah M
    Med J Malaysia, 2000 Mar;55(1):51-7.
    PMID: 11072491 MyJurnal
    Exposure to Portland cement dust has long been associated with the prevalence of respiratory symptoms and varying degrees of airway obstruction in man. Apart from respiratory diseases, it was also found to be the cause of lung and laryngeal cancer, gastrointestinal tumours and also dermatitis. This study was done to investigate the effect of dust exposure on ventilatory lung function of Portland cement factory workers in Rawang, Selangor. Spirometry tests of 62 male workers (exposed to total dust concentration of 10,180 micrograms/m3 and PM10 of 8049 micrograms/m3) and 70 subjects from UPM (exposed to mean total dust of 192 micrograms/m3 and PM10 of 177 micrograms/m3--controls) revealed significant differences in spirometry values between the groups. The workers showed i) significantly lower FEV1% and FEF25-75%, and higher FMFT, ii) reduced FEV1% with increasing level of dust exposure and iii) higher prevalence of respiratory symptoms. Therefore, we suggest that exposure to dust in the cement factory leads to higher incidence of respiratory symptoms and impaired lung function.
    Matched MeSH terms: Respiratory Function Tests
  17. Zainudin BM, Roslina AM, Fadilah SA, Samad SA, Sufarlan AW, Isa MR
    Med J Malaysia, 1996 Mar;51(1):136-40.
    PMID: 10967994
    Three cases of diffuse panbronchiolitis (DPB) occurring in two Malaysian Chinese patients and one Malay patient are reported. They had similar clinical, radiological and physiological features which are characteristic of DPB. The diagnosis in one of the cases was confirmed histologically by transbronchial lung biopsy. These could be the first three cases identified in Malaysia.
    Matched MeSH terms: Respiratory Function Tests
  18. Zafar Ahmed, Sharifa Ezat Wan Puteh, Aisha Abdussalam, Mahmud Hanesh, Suriati Sukeri, Joseph, Leonard
    Int J Public Health Res, 2012;2(1):65-74.
    MyJurnal
    OBJECTIVE. Chronic obstructive pulmonary disease (COPD) is a one of the major cause of death and disability worldwide. This study aimed to compare the quality of life (QOL), Activity of Daily Living (ADL), Pulmonary Function Test (PFT) and general health symptoms pre and after hospital-based respiratory physiotherapy program among COPD patients. METHODS. Pre and post intervention study was conducted between January and July 2010. A total of 54 subjects aged between 30 to 40 years old were recruited for this study using universal sampling method from Alzawia Teaching Hospital, Libya. Data collected were socio-demographic data, QOL (before and after the intervention) using the Short Form-36 (SF-36) questionnaire, ADL using the Barthel Index and the General Health Symptoms.
    RESULTS.. The mean SF-36 score for QOL is 30.13 (SD = 8.06) and 63.46 (SD = 13.53) before and after the physiotherapy respectively (with the p <0.0001). Patients’ Activity of Daily Living mean scores are 70.18, (SD = 16.50) and mean = 88.89 (SD = 13.28) before and after program (p< 0.0001). The general medical condition mean score after respiratory physiotherapy is 3.72 as compared to 4.96 before the respiratory physiotherapy (p< 0.0001). Pulmonary Function Test shows improvement in actual/predicted FEV1 ratio in all 54 cases with mean improvement from 55.85 before to 81.67 after the pulmonary physiotherapy (with the p <0.0001).
    CONCLUSION. Hospital based respiratory physiotherapy program had significantly improved QOL, pulmonary function and activities of daily living among the subjects.
    Matched MeSH terms: Respiratory Function Tests
  19. Ahmad Syazrin Muhammad, Juliana Jalaludin, NurAqilah M. Yusof
    MyJurnal
    Exposure to traffic air pollutant have shown a significant health effect on respiratory systems and decreased in lung function among traffic policemen. The main objective of this study was to determine the relationships between personal exposure levels to PM2.5 and respiratory health among traffic policemen working at Traffic Police Station in Kuala Lumpur and general duty policemen attached to Police Headquarters, Bukit Aman. A cross sectional comparative study was conducted among 50 traffic policemen from Traffic Police Station Kuala Lumpur and 50 general duty policemen from Police Headquarters Bukit Aman as comparative group. A purposive sampling method was used to select the respondents based on inclusive criteria such as age between 25 to 60 years, no history of respiratory disease and working not less than 3 years as traffic policemen. Questionnaire based on ATS (1978) was used to collect information on socio-demographic and respiratory symptoms. Spirometer (Spirolab II Model) was used to perform lung function tests. Personal Air Sampling Pump (Aircheck 52) was used to measure personal exposure level to PM2.5. The mean exposure level of PM2.5 among the traffic policemen was 22.33 ± 8.54μg/m³ compared to only 5.60 ± 4.29μg/m³ for comparative group. There was a significant difference in all lung function parameters between the exposed group and comparative group.From the finding, it shows that there was significant relationship between working duration (years) and lung function parameters among both exposed and comparative group. The result from this research shows that traffic policemen were determined as having lower lung function parameters due to their nature of work and the environment. Also, there was a significant association between exposure to fine particle (PM2.5) and lung function among the exposed group. Finding from this study indicated that exposure to elevated concentration level to traffic related air pollutant was the risk factors in the development of respiratory diseases as shown by the higher prevalence of respiratory symptoms and the reduction in lung function among traffic policemen.
    Matched MeSH terms: Respiratory Function Tests
  20. Menon MA, Vaterlaws AL, Cheok T
    Med J Malaysia, 1979 Jun;33(4):299-303.
    PMID: 522740
    Matched MeSH terms: Respiratory Function Tests
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links