Displaying all 16 publications

Abstract:
Sort:
  1. Jawad MM, Husein A, Alam MK, Hassan R, Shaari R
    Lasers Med Sci, 2014 Jan;29(1):367-72.
    PMID: 22986701 DOI: 10.1007/s10103-012-1199-8
    The need for orthodontic treatment is increasing all the time. As the treatment is time consuming ranging from a year to several years, any method of reducing the period of treatment and increasing the quality of the tissue will be beneficial to patients. The use of non-invasive techniques such as low level laser therapy and low intensity pulsed ultasound in accelerating orthodontic tooth movement are promising. Thus, this overview study will help to generate more understanding about the background information and the possible applications of them in daily orthodontics, depending on previous literature searching for reviews and original research articles.
    Matched MeSH terms: Ultrasonic Therapy/methods*; Ultrasonic Therapy/trends
  2. Ahmad M, Roy RA, Kamarudin AG
    Int Endod J, 1994 Jan;27(1):26-31.
    PMID: 7806408
    The present study was undertaken to see if there was any variability in the power output of Piezon-Master 400 ultrasonic files when driven using different generators, tranducers and file holders. The displacement amplitude of the oscillating tip of the file in air was used as a measure of the power output. The results showed that there was considerable variability in the power output of Piezon-Master 400 ultrasonic files of similar size and length when driven using different generators, transducers and file holders. In consideration of this, it is recommended that a calibration device be incorporated in the ultrasonic unit so that the operator will have some knowledge of when the unit is working at its maximum efficiency.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  3. Ahmad M, Roy RA, Kamarudin AG, Safar M
    Int Endod J, 1993 Mar;26(2):120-4.
    PMID: 8330934
    The pattern of oscillation of a Piezon-Master 400 ultrasonic file driven by a piezoelectric transducer was studied in air and on water. In addition, the displacement amplitudes of the files were measured. The findings were compared with those observed with the Cavi-Endo unit reported in another study (Ahmad 1969). It was observed that the file vibrated such that a standing wave was formed on the file and it exhibited points of maximum deflection (antinode) and points of minimum deflection (node) with the largest deflection occurring at the apical end. This pattern of oscillation was similar to that exhibited by the Cavi-Endo file which employed a magnetostrictive transducer. However, the displacement amplitudes were very much higher than those exhibited by the Cavi-Endo. It is considered that the 120 degrees angle of the file holder inherent in the Piezon-Master 400 unit and the more effective power transmission with the piezoelectric transducer may have contributed to the large amplitudes.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  4. Abdul Hayei NA, Yahya NA, Safii SH, Saub R, Vaithilingam RD, Baharuddin NA
    BMC Oral Health, 2021 03 31;21(1):169.
    PMID: 33789646 DOI: 10.1186/s12903-021-01540-0
    BACKGROUND: The influence of scaler tip design on root surface roughness, tooth substance loss and patients' pain perception is investigated.

    METHODS: This article was divided into the following parts: Part 1 Surface roughness and substance loss: an in vitro study, which involves intact extracted teeth sectioned and treated using a piezoelectric ultrasonic device (PM200 EMS Piezon, Switzerland) with a conventional scaler tip (FS-407) and a Perio Slim (PS) scaler tip (Perio Slim DS-016A). All sectioned samples for tooth surface roughness (n = 20) and tooth substance loss (n = 46) analyses were measured and compared using a 3D surface texture analyser and scanning electron microscope (SEM) respectively, at baseline and following scaling. Part 2 Pain Perception: a clinical study, which was a split mouth study design including 30 participants with gingivitis and/or mild chronic periodontitis; treated with supra-gingival scaling from teeth #13 to #23. Subjects were randomised to group A or group B. Group A was treated first with PS scaler tips, whereas group B was treated first with conventional scaler tips. Pain perception was recorded using the visual analogue scale (VAS).

    RESULTS: In vitro study: both scaler tips caused significant reduction in root substance roughness after scaling (p  0.05) was observed. The PS scaler tip caused statistically significantly less root substance loss (p 

    Matched MeSH terms: Ultrasonic Therapy*
  5. Dabbagh A, Abdullah BJ, Ramasindarum C, Abu Kasim NH
    Ultrason Imaging, 2014 Oct;36(4):291-316.
    PMID: 24626566 DOI: 10.1177/0161734614526372
    Tissue-mimicking phantoms that are currently available for routine biomedical applications may not be suitable for high-temperature experiments or calibration of thermal modalities. Therefore, design and fabrication of customized thermal phantoms with tailored properties are necessary for thermal therapy studies. A multitude of thermal phantoms have been developed in liquid, solid, and gel forms to simulate biological tissues in thermal therapy experiments. This article is an attempt to outline the various materials and techniques used to prepare thermal phantoms in the gel state. The relevant thermal, electrical, acoustic, and optical properties of these phantoms are presented in detail and the benefits and shortcomings of each type are discussed. This review could assist the researchers in the selection of appropriate phantom recipes for their in vitro study of thermal modalities and highlight the limitations of current phantom recipes that remain to be addressed in further studies.
    Matched MeSH terms: Ultrasonic Therapy*
  6. Ahmad M, Roy RA, Kamarudin AG
    Endod Dent Traumatol, 1992 Oct;8(5):189-94.
    PMID: 1302678
    The steady acoustic streaming generated around straight and precurved oscillating ultrasonic files driven by the Piezon-Master 400 unit was examined in the free field and in small channels using a stereomicroscope. In addition, the effect of file-wall contact on streaming production was also investigated. The results indicated that the ultrasonic files can generate acoustic streaming both in the free field and in the small channel. Higher velocity streaming was observed when smaller size files were employed and when the file was precurved. Light file-wall contact did not totally inhibit streaming while severe file-wall contact inhibited movement of the file and, as a result, no streaming was observed. The positions and length scales of the streaming vortices appeared to be influenced by the presence of boundaries. In the free field, two rows of vortices were situated along the sides of the file while in the small channel, the vortices were positioned above the surface of the file. These results indicated that it is possible for acoustic streaming to occur in a confined space as in a root canal provided that severe file-wall contact is avoided. It is therefore recommended that light filing or allowing the file to freely vibrate during some stage of treatment should be carried out in order to generate streaming in the root canal.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  7. Ahmad M
    Endod Dent Traumatol, 1990 Feb;6(1):12-5.
    PMID: 2202589
    The resonant characteristics of ultrasonic files driven by the Cavi-Endo unit were examined. The investigation was carried out by evaluating the pattern of oscillation and the power emitted by the ultrasonic files. It was observed that the files oscillated in a sinusoidal fashion, exhibiting a standing wave pattern along the file. The power emitted was found to be directly proportional to the flexibility of the file. Such behaviour is typical of a system that exhibits resonance.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  8. Ahmad M
    Endod Dent Traumatol, 1990 Jun;6(3):104-8.
    PMID: 2079012
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  9. Ahmad M
    Endod Dent Traumatol, 1990 Oct;6(5):230-1.
    PMID: 2133315
    The temperature rise of the irrigant in the root canal during free vibration of the ultrasonic file was studied in vitro in 10 human teeth. The mean temperature rise was found to be 0.6 degrees C. The minimal temperature increase may not significantly contribute to the effectiveness of ultrasonic root canal instrumentation.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  10. Ahmad M, Roy RA
    Endod Dent Traumatol, 1994 Apr;10(2):71-6.
    PMID: 8062810
    The incidence of breakage of Piezon-Master ultrasonic K files were evaluated. Three groups of unused files were subjected to three treatments, namely; free vibration in air without irrigation, free vibration in root canal while minimizing contact with the wall of canal in the presence of irrigation and light filing in root canal with free flow of irrigation. Cavitation produced by files in contact and free of contact with a glass surface was examined in order to observe the relationship between cavitation defects and breakage. In addition, the fractured and unfractured files were examined under a scanning electron microscope for the presence of cavitation pits. The results indicated that more files broke in air. In water, a higher incidence of breakage occurred when files were allowed to freely vibrate while no breakage occurred when the files were used in filing. All files generated cavitation which resulted in pitting of their surfaces. However, it was considered unlikely that the pits contributed to fracture. Fatigue cracks which could be the result of the manufacturing process were observed at some of the corners of the cross sections of the fractured files and could be the main contributory factor to fracture.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation
  11. Ahmad M
    Endod Dent Traumatol, 1991 Apr;7(2):55-8.
    PMID: 1782894
    The efficacy of two ultrasonic units in shaping curved canals in teeth were compared. Twenty teeth were instrumented using the Cavi-Endo unit at a power setting 1 using the technique recommended by the manufacturer. Another group of 20 teeth received similar treatment but were instrumented with the Enac unit. The time taken to instrument each canal was recorded. The pre- and post-instrumented radiographs of the teeth of x 10 magnification were taken using a microfocal technique. The radiographs were subjected to a subtraction technique to result in composite images of the pre- and post-instrumented shapes. The canal shape and the incidence of elbows were evaluated using various measurements taken from the radiographs. The manner the dentine was removed was similar in both groups. All canals exhibited unequal removal along the canal with more dentine being removed at the coronal end. The Enac group exhibited a higher incidence of elbows which occurred further apically than those in the Cavi-Endo group. There was no significant difference between groups in the following: time of instrumentation, amount of apical and coronal canal enlargement, apical deviation and change in width at the elbow. These findings were no different from those of another study using simulated canals.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  12. Ahmad M, Pitt Ford TR, Crum LA, Wilson RF
    Oral Surg. Oral Med. Oral Pathol., 1990 Sep;70(3):328-32.
    PMID: 2216361
    The physical mechanisms of ultrasound, namely cavitation and acoustic streaming, generated by the Enac-Osada ultrasonic unit were investigated for effectiveness in disrupting Streptococcus mitis. In addition, the bactericidal effect of ultrasound in the presence of 2.5% sodium hypochlorite was examined. Bacterial suspensions were irradiated directly with ultrasound in simulated root canals, and the viability of bacteria was examined after growth on a blood agar medium under anaerobic conditions at 37 degrees C for 5 days. The results indicated that ultrasound per se failed to disrupt bacteria but resulted in increases in the viable counts; the former was considered to be because of the lack of cavitation and the latter because of the dispersal effects of acoustic streaming. The 2.5% sodium hypochlorite solution demonstrated powerful bactericidal activity.
    Matched MeSH terms: Ultrasonic Therapy/instrumentation*
  13. Singh VA, Shah SU, Yasin NF, Abdullah BJJ
    J Orthop Surg (Hong Kong), 2017 May-Aug;25(2):2309499017716256.
    PMID: 28659052 DOI: 10.1177/2309499017716256
    AIMS: Magnetic resonance guided focused ultrasound (MRgFUS) is a new modality in the management of primary and secondary bone tumors. We aimed to investigate the safety, efficacy, and feasibility of using MRgFUS for the treatment of (1) benign bone tumors with the intent of complete tumor ablation, (2) primary malignant bone tumors with the intent to assess its effectiveness in causing tumor necrosis, and (3) metastatic bone disease with the intent of pain relief.

    METHOD: Twenty-four patients with benign bone tumors, primary malignant bone tumors, and metastatic bone disease were treated with one session of MRgFUS. Contrast-enhanced (CE) magnetic resonance imaging (MRI) was carried out post-procedure to assess and quantify the area of ablation. Those with malignant primary tumors had the tumors resected 2 weeks after the treatment and the ablated areas were examined histopathologically (HPE). The other patients were followed up for 3 months to assess for the side effects and pain scores.

    RESULTS: Significant volume of ablation was noted on CE MRI after the treatment. Benign bone tumors were ablated with minimal adverse effects. Metastatic bone disease was successfully treated with significant decrease in pain scores. Ablated primary malignant tumors showed significant coagulative necrosis on MRI and the HPE showed 100% necrosis. Pain scores significantly decreased 3 months after the procedure. Only two patients had superficial skin blistering and three patients had increase in pain scores immediately after treatment.

    CONCLUSION: MRgFUS is effective, safe, and noninvasive procedure that can be an adjunct in the management of primary and metastatic bone tumors.
    Matched MeSH terms: Ultrasonic Therapy/methods*
  14. Sim SE, Gunasagaran J, Goh KJ, Ahmad TS
    J Hand Ther, 2018 02 13;32(4):411-416.
    PMID: 29426574 DOI: 10.1016/j.jht.2018.01.004
    STUDY DESIGN: Prospective randomized study.

    INTRODUCTION: Carpal tunnel syndrome (CTS) has been described as the most common compression neuropathy. Many modalities exist for conservative treatment. Efficacy of each modality has been described in the literature. However, the effectiveness of combination of these modalities is not well established. The purpose of this study is to assess the short-term clinical outcome of conservative treatment for CTS comparing orthosis alone with combination of orthosis, nerve/tendon gliding exercises, and ultrasound therapy.

    METHODS: Forty-one patients who presented to Upper Limb Reconstructive and Microsurgery Clinic, University Malaya Medical Centre with CTS and positive electrodiagnostic study were recruited. Fifteen patients had bilateral CTS. Fifty-six wrists were equally randomized to orthosis alone and a combined therapy of orthosis, nerve/tendon gliding exercise, and ultrasound therapy. All patients were required to complete the Boston Carpal Tunnel Questionnaire during the first visit and 2 months after treatment.

    RESULTS: Both the orthosis and combined therapy groups showed a significant improvement in symptoms and function after treatment. The mean difference of symptoms in the orthosis group was 0.53; 95% confidence interval [CI]: 0.23-0.83 (P = .001) and in the combined therapy group was 0.48; 95% CI: 0.24-0.72 (P 

    Matched MeSH terms: Ultrasonic Therapy*
  15. Ramli R, Ngeow WC, Rahman RA, Chai WL
    Singapore Dent J, 2006 Dec;28(1):11-5.
    PMID: 17378336
    Head and neck cancer is becoming a more recognizable pathology to the general population and dentists. The modes of treatment include surgery and/or radiation therapy. Pretreatment dental assessment should be provided for these patients before they undergo radiation therapy. There are occasions, however, whereby head and neck cancer patients are not prepared optimally and, as a result, they succumb to complicated oral adverse effects after radiation therapy. Osteoradionecrosis (ORN) is a severe debilitating condition that impairs healing due to reduction in vascularity and osteocyte population in the affected bone. This article reviews methods of treatment used to treat ORN such as antibiotics, hyperbaric oxygen therapy, therapeutic ultrasound, surgery, and other modalities.
    Matched MeSH terms: Ultrasonic Therapy
  16. Loh LC, Eg KP, Puspanathan P, Tang SP, Yip KS, Vijayasingham P, et al.
    Asian Pac J Allergy Immunol, 2004 Mar;22(1):11-7.
    PMID: 15366653
    Airway inflammation can be demonstrated by the modem method of sputum induction using ultrasonic nebulizer and hypertonic saline. We studied whether compressed-air nebulizer and isotonic saline which are commonly available and cost less, are as effective in inducing sputum in normal adult subjects as the above mentioned tools. Sixteen subjects underwent weekly sputum induction in the following manner: ultrasonic nebulizer (Medix Sonix 2000, Clement Clarke, UK) using hypertonic saline, ultrasonic nebulizer using isotonic saline, compressed-air nebulizer (BestNeb, Taiwan) using hypertonic saline, and compressed-air nebulizer using isotonic saline. Overall, the use of an ultrasonic nebulizer and hypertonic saline yielded significantly higher total sputum cell counts and a higher percentage of cell viability than compressed-air nebulizers and isotonic saline. With the latter, there was a trend towards squamous cell contaminations. The proportion of various sputum cell types was not significantly different between the groups, and the reproducibility in sputum macrophages and neutrophils was high (Intraclass correlation coefficient, r [95%CI]: 0.65 [0.30-0.91] and 0.58 [0.22-0.89], p < 0.001). Overall changes in median FEV, were small and comparable between all groups. Induction using ultrasonic nebulizers together with hypertonic saline was generally less well tolerated than compressed-air nebulizers and isotonic saline. We conclude that in normal subjects, although both nebulizers and saline types can induce sputum with reproducible cellular profile, ultrasonic nebulizers and hypertonic saline are more effective but less well tolerated.
    Matched MeSH terms: Ultrasonic Therapy/methods*