Displaying all 15 publications

Abstract:
Sort:
  1. Al Azzam KM, Saad B, Aboul-Enein HY
    Biomed Chromatogr, 2010 Sep;24(9):948-53.
    PMID: 20082285 DOI: 10.1002/bmc.1390
    Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non-UV-absorbing L-valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 degrees C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused-silica capillary (75 microm, i.d. x 52 cm). The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5-250 microg/mL for the studied analytes. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations.
    Matched MeSH terms: Atenolol/analysis*
  2. Reddy AVB, Yusop Z, Jaafar J, Bin Aris A, Abdul Majid Z
    J Sep Sci, 2017 Aug;40(15):3086-3093.
    PMID: 28581679 DOI: 10.1002/jssc.201700252
    An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process-related impurities, viz., 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, 4-hydroxyphenylacetic acid, methyl-4-hydroxyphenylacetate, and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX-5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 μm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid at 0.3 ppm, and methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3-10 ppm for 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid, and 0.35-10 ppm for methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.
    Matched MeSH terms: Atenolol/analysis*
  3. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2012 May;24(5):356-67.
    PMID: 22517322 DOI: 10.1002/chir.22019
    Because chiral liquid chromatography (LC) could become a powerful tool to estimate racemic atenolol quantity, excellent enantiomeric separation should be produced during data acquisition for satisfactory observation of atenolol concentrations throughout the racemic resolution processes. Selection of chiral LC column and analytical protocol that fulfill demands of the ultra fast LC analysis is essential. This article describes the characteristics of atenolol chromatographic separation that resulted from different resolution media and analytical protocols with the use of a Chiralcel® OD column. The chromatograms showed quite different characteristics of the separation process. The single enantiomer and racemic atenolol could be recognized by the Chiralcel® OD column in less than 20 min. Symmetrical peaks were obtained; however, several protocols produced peaks with wide bases and slanted baselines. Observations showed that efficient enantioresolution of racemic atenolol was obtained at slow mobile phase flow rate, decreased concentration of amine-type modifier but increased alcohol content in mobile phase and highest ultraviolet detection wavelength were required. The optimal ultra fast LC protocol enables to reduce and eliminate the peaks of either the atenolol solvent or the buffers and provided the highest peak intensities of both atenolol enantiomers.
    Matched MeSH terms: Atenolol/isolation & purification*; Atenolol/metabolism; Atenolol/chemistry*
  4. Peh KK, Yuen KH, Wong JW, Toh WT
    Drug Dev Ind Pharm, 1999 Mar;25(3):357-60.
    PMID: 10071830
    A study was conducted to compare the bioavailability of a generic product of atenolol (Normaten FC) with the innovator product, Tenormin. Twelve healthy adult volunteers participated in the study conducted according to a randomized, two-way crossover design. The preparations were compared using area under the plasma concentration-time curve AUC0-infinity, peak plasma concentration Cmax, and time to reach peak plasma concentration Tmax. No statistically significant difference was obtained between the Tmax values and the logarithmic transformed AUC0-infinity and Cmax values of the two products. Moreover, the 90% confidence interval for the ratio of the logarithmically transformed AUC0-infinity values of Normaten FC over those of Tenormin was found to lie between 0.82 and 0.98, while that of the logarithmically transformed Cmax values was between 0.82 and 1.09, both being within the bioequivalence limit of 0.80-1.25. The values of elimination half-life t1/2 between the two products were also found comparable and not significantly different statistically. The t1/2 values obtained in our study were slightly longer than those reported in the literature for other population groups.
    Matched MeSH terms: Atenolol/administration & dosage*; Atenolol/blood; Atenolol/pharmacokinetics*
  5. Goh KZ, Ahmad AA, Ahmad MA
    Environ Sci Pollut Res Int, 2024 Jan;31(1):1158-1176.
    PMID: 38038911 DOI: 10.1007/s11356-023-31177-1
    This study aimed to assess the dynamic simulation models provided by Aspen adsorption (ASPAD) and artificial neural network (ANN) in understanding the adsorption behavior of atenolol (ATN) on gasified Glyricidia sepium woodchips activated carbon (GGSWAC) within fixed bed columns for wastewater treatment. The findings demonstrated that increasing the bed height from 1 to 3 cm extended breakthrough and exhaustion times while enhancing adsorption capacity. Conversely, higher initial ATN concentrations resulted in shorter breakthrough and exhaustion times but increased adsorption capacity. Elevated influent flow rates reduced breakthrough and exhaustion times while maintaining constant adsorption capacity. The ASPAD software demonstrated competence in accurately modeling the crucial exhaustion points. However, there is room for enhancement in forecasting breakthrough times, as it exhibited deviations ranging from 6.52 to 239.53% when compared to the actual experimental data. ANN models in both MATLAB and Python demonstrated precise predictive abilities, with the Python model (R2 = 0.985) outperforming the MATLAB model (R2 = 0.9691). The Python ANN also exhibited superior fitting performance with lower MSE and MAE. The most influential factor was the initial ATN concentration (28.96%), followed by bed height (26.39%), influent flow rate (22.43%), and total effluent time (22.22%). The findings of this study offer an extensive comprehension of breakthrough patterns and enable accurate forecasts of column performance.
    Matched MeSH terms: Atenolol
  6. AL Azzam KM, Aboul-Enein HY
    Methods Mol Biol, 2013;919:67-78.
    PMID: 22976091 DOI: 10.1007/978-1-62703-029-8_7
    Capillary electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of the β-blocker drugs (atenolol and amiloride) in pharmaceutical formulations. 150 mM acetic acid was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature, and injection time) was studied. Non-UV absorbing L-valine was used as an internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 °C, 25 kV, and using hydrodynamic injection (25 s). The separation was effected in a bare fused-silica capillary 75 μm × 52 cm. The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision, and selectivity. Calibration curves were linear over the range 5-250 μg mL(-1) for the studied analytes. The relative standard deviations of intra- and inter-day precisions of migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of the β-blocker drugs in different pharmaceutical tablets.
    Matched MeSH terms: Atenolol/analysis*; Atenolol/chemistry
  7. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2017 Jul;29(7):376-385.
    PMID: 28439969 DOI: 10.1002/chir.22702
    As the (R)-enantiomer of racemic atenolol has no β-blocking activity and no lack of side effects, switching from the racemate to the (S)-atenolol is more favorable. Transesterification of racemic atenolol using free enzymes investigated as a resource to resolve the racemate via this method is limited. Screenings of enzyme, medium, and acetyl donor were conducted first to give Pseudomonas fluorescens lipase, tetrahydrofuran, and vinyl acetate. A statistical design of the experiment was then developed using Central Composite Design on some operational factors, which resulted in the conversions of 11.70-61.91% and substrate enantiomeric excess (ee) of 7.31-100%. The quadratic models are acceptable with R2 of 95.13% (conversion) and 89.63% (ee). The predicted values match the observed values reasonably well. Temperature, agitation speed, and substrate molar ratio factor have low effects on conversion and ee, but enzyme loading affects the responses highly. The interaction of temperature-agitation speed and temperature-substrate molar ratio show significant effects on conversion, while temperature-agitation speed, temperature-substrate molar ratio, and agitation speed-substrate molar ratio affect ee highly. Optimum conditions for the use of Pseudomonas fluorescens lipase, tetrahydrofuran, and vinyl acetate were found at 45°C, 175 rpm, 2000 U, and 1:3.6 substrate molar ratio.
    Matched MeSH terms: Atenolol/isolation & purification; Atenolol/chemistry*
  8. Ramanathan M
    Singapore Med J, 1996 Apr;37(2):218-9.
    PMID: 8942269
    This report deals with a 54-year-old man with loss of memory. His impaired memory was found to be due to the atenolol he was on and he made a complete recovery on withdrawing the beta-blocker. This patient's experience stresses the need to consider beta-blockers as a potentially reversible cause of memory impairment.
    Matched MeSH terms: Atenolol/adverse effects*; Atenolol/therapeutic use
  9. Al Azzam KM, Saad B, Aboul-Enein HY
    Biomed Chromatogr, 2010 Sep;24(9):977-81.
    PMID: 20066730 DOI: 10.1002/bmc.1395
    Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations.
    Matched MeSH terms: Atenolol/analysis*
  10. Venkatesh G, Ramanathan S, Mansor SM, Nair NK, Sattar MA, Croft SL, et al.
    J Pharm Biomed Anal, 2007 Mar 12;43(4):1546-51.
    PMID: 17157469
    A simple, sensitive and specific reversed phase high performance liquid chromatographic (RP-HPLC) method with UV detection at 251 nm was developed for simultaneous quantitation of buparvaquone (BPQ), atenolol, propranolol, quinidine and verapamil. The method was applicable in rat in situ intestinal permeability study to assess intestinal permeability of BPQ, a promising lead compound for Leishmania donovani infections. The method was validated on a C-4 column with mobile phase comprising ammonium acetate buffer (0.02 M, pH 3.5) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 ml/min. The retention times for atenolol, quinidine, propranolol, verapamil and BPQ were 4.30, 5.96, 6.55, 7.98 and 8.54 min, respectively. The calibration curves were linear (correlation coefficient > or =0.996) in the selected range of each analyte. The method is specific and sensitive with limit of quantitation of 15 microg/ml for atenolol, 0.8 microg/ml for quinidine, 5 microg/ml for propranolol, 10 microg/ml for verapamil and 200 ng/ml for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and all the analytes were found to be stable. This method is simple, reliable and can be routinely used for accurate permeability characterization.
    Matched MeSH terms: Atenolol/analysis*; Atenolol/pharmacokinetics; Atenolol/chemistry
  11. Venkatesh G, Ramanathan S, Nair NK, Mansor SM, Sattar MA, Khan MA, et al.
    Biomed Chromatogr, 2007 May;21(5):484-90.
    PMID: 17294505
    A simple and sensitive RP-HPLC-UV method was developed and validated for simultaneous determination of atenolol and propranolol and subsequently applied to investigate the effect of dimethyl sulfoxide in rat in situ intestinal permeability studies. Atenolol (400 microm) and propranolol (100 microm) were perfused in the small intestine of anaesthetized (pentobarbitone sodium 60 mg/kg, i.p.) male Sprague-Dawley rats either in the presence (1, 3 and 5%) or in the absence of dimethyl sulfoxide. There was no significant alteration (p > 0.05) in the permeability of atenolol and propranolol, which indicated there was no effect of various concentrations of dimethyl sulfoxide (1-5%) on the membrane integrity of the rat intestinal tissues. The analytical method was validated on a C(4) column with a mobile phase comprising ammonium acetate buffer (pH 3.5, 0.02 m) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 mL/min. The validated method was found to be accurate and precise and stability studies were carried out at different storage conditions and both analytes were found to be stable. These findings are applicable for determining the absorbability of water-insoluble drugs and new chemical entities for the purpose of classifying them in the biopharmaceutical classification system.
    Matched MeSH terms: Atenolol/pharmacokinetics*
  12. Khalit WN, Tay KS
    Environ Sci Pollut Res Int, 2016 Feb;23(3):2521-9.
    PMID: 26423291 DOI: 10.1007/s11356-015-5470-y
    This study investigated the reaction kinetics and the transformation by-products of acebutolol during aqueous chlorination. Acebutolol is one of the commonly used β-blockers for the treatment of cardiovascular diseases. It has been frequently detected in the aquatic environment. In the kinetics study, the second-order rate constant for the reaction between acebutolol and chlorine (k app) was determined at 25 ± 0.1 °C. The degradation of acebutolol by free available chlorine was highly pH dependence. When the pH increased from 6 to 8, it was found that the k app for the reaction between acebutolol and free available chlorine was increased from 1.68 to 11.2 M(-1) min(-1). By comparing with the reported k app values, the reactivity of acebutolol toward free available chlorine was found to be higher than atenolol and metoprolol but lower than nadolol and propranolol. Characterization of the transformation by-products formed during the chlorination of acebutolol was carried out using liquid chromatography-quadrupole time-of-flight high-resolution mass spectrometry. Seven major transformation by-products were identified. These transformation by-products were mainly formed through dealkylation, hydroxylation, chlorination, and oxidation reactions.
    Matched MeSH terms: Atenolol/chemistry
  13. Khor KH, Shiels IA, Campbell FE, Greer RM, Rose A, Mills PC
    Vet J, 2014 Feb;199(2):229-35.
    PMID: 24321367 DOI: 10.1016/j.tvjl.2013.11.006
    Analysis of heart rate (HR) and heart rate variability (HRV) are powerful tools to investigate cardiac diseases, but current methods, including 24-h Holter monitoring, can be cumbersome and may be compromised by movement artefact. A commercially available data capture and analysis system was used in anaesthetised healthy cats to measure HR and HRV during pharmacological manipulation of HR. Seven healthy cats were subjected to a randomised crossover study design with a 7 day washout period between two treatment groups, placebo and atenolol (1mg/kg, IV), with the efficacy of atenolol to inhibit β1 adrenoreceptors challenged by epinephrine. Statistical significance for the epinephrine challenge was set at P<0.0027 (Holm-Bonferroni correction), whereas a level of significance of P<0.05 was set for other variables. Analysis of the continuous electrocardiography (ECG) recordings showed that epinephrine challenge increased HR in the placebo group (P=0.0003) but not in the atenolol group. The change in HR was greater in the placebo group than in the atenolol group (P=0.0004). Therefore, compared to cats pre-treated with placebo, pre-treatment with atenolol significantly antagonised the tachycardia while not significantly affecting HRV. The increased HR in the placebo group following epinephrine challenge was consistent with a shift of the sympathovagal balance towards a predominantly sympathetic tone. However, the small (but not significant at the critical value) decrease in the normalised high-frequency component (HFnorm) in both groups of cats suggested that epinephrine induced a parasympathetic withdrawal in addition to sympathetic enhancement (increased normalised low frequency component or LFnorm). In conclusion, this model is a highly sensitive and repeatable model to investigate HRV in anaesthetised cats that would be useful in the laboratory setting for short-term investigation of cardiovascular disease and subtle responses to pharmacological agents in this species.
    Matched MeSH terms: Atenolol/pharmacology
  14. Yusuf S, Joseph P, Dans A, Gao P, Teo K, Xavier D, et al.
    N Engl J Med, 2021 01 21;384(3):216-228.
    PMID: 33186492 DOI: 10.1056/NEJMoa2028220
    BACKGROUND: A polypill comprising statins, multiple blood-pressure-lowering drugs, and aspirin has been proposed to reduce the risk of cardiovascular disease.

    METHODS: Using a 2-by-2-by-2 factorial design, we randomly assigned participants without cardiovascular disease who had an elevated INTERHEART Risk Score to receive a polypill (containing 40 mg of simvastatin, 100 mg of atenolol, 25 mg of hydrochlorothiazide, and 10 mg of ramipril) or placebo daily, aspirin (75 mg) or placebo daily, and vitamin D or placebo monthly. We report here the outcomes for the polypill alone as compared with matching placebo, for aspirin alone as compared with matching placebo, and for the polypill plus aspirin as compared with double placebo. For the polypill-alone and polypill-plus-aspirin comparisons, the primary outcome was death from cardiovascular causes, myocardial infarction, stroke, resuscitated cardiac arrest, heart failure, or revascularization. For the aspirin comparison, the primary outcome was death from cardiovascular causes, myocardial infarction, or stroke. Safety was also assessed.

    RESULTS: A total of 5713 participants underwent randomization, and the mean follow-up was 4.6 years. The low-density lipoprotein cholesterol level was lower by approximately 19 mg per deciliter and systolic blood pressure was lower by approximately 5.8 mm Hg with the polypill and with combination therapy than with placebo. The primary outcome for the polypill comparison occurred in 126 participants (4.4%) in the polypill group and in 157 (5.5%) in the placebo group (hazard ratio, 0.79; 95% confidence interval [CI], 0.63 to 1.00). The primary outcome for the aspirin comparison occurred in 116 participants (4.1%) in the aspirin group and in 134 (4.7%) in the placebo group (hazard ratio, 0.86; 95% CI, 0.67 to 1.10). The primary outcome for the polypill-plus-aspirin comparison occurred in 59 participants (4.1%) in the combined-treatment group and in 83 (5.8%) in the double-placebo group (hazard ratio, 0.69; 95% CI, 0.50 to 0.97). The incidence of hypotension or dizziness was higher in groups that received the polypill than in their respective placebo groups.

    CONCLUSIONS: Combined treatment with a polypill plus aspirin led to a lower incidence of cardiovascular events than did placebo among participants without cardiovascular disease who were at intermediate cardiovascular risk. (Funded by the Wellcome Trust and others; TIPS-3 ClinicalTrials.gov number, NCT01646437.).

    Matched MeSH terms: Atenolol/administration & dosage
  15. Joseph P, Pais P, Dans AL, Bosch J, Xavier D, Lopez-Jaramillo P, et al.
    Am Heart J, 2018 Dec;206:72-79.
    PMID: 30342297 DOI: 10.1016/j.ahj.2018.07.012
    BACKGROUND: It is hypothesized that in individuals without clinical cardiovascular disease (CVD), but at increased CVD risk, a 50% to 60% reduction in CVD risk could be achieved using fixed dose combination (FDC) therapy (usually comprised of multiple blood-pressure agents and a statin [with or without aspirin]) in a single "polypill". However, the impact of a polypill in preventing clinical CV events has not been evaluated in a large randomized controlled trial.

    METHODS: TIPS-3 is a 2x2x2 factorial randomized controlled trial that will examine the effect of a FDC polypill on major CV outcomes in a primary prevention population. This study aims to determine whether the Polycap (comprised of atenolol, ramipril, hydrochlorothiazide, and a statin) reduces CV events in persons without a history of CVD, but who are at least at intermediate CVD risk. Additional interventions in the factorial design of the study will compare the effect of (1) aspirin versus placebo on CV events (and cancer), (2) vitamin D versus placebo on the risk of fractures, and (3) the combined effect of aspirin and the Polycap on CV events.

    RESULTS: The study has randomized 5713 participants across 9 countries. Mean age of the study population is 63.9 years, and 53% are female. Mean INTERHEART risk score is 16.8, which is consistent with a study population at intermediate CVD risk.

    CONCLUSION: Results of the TIP-3 study will be key to determining the appropriateness of FDC therapy as a strategy in the global prevention of CVD.

    Matched MeSH terms: Atenolol/administration & dosage*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links